Volumn 46, Issue 4, 2011, Pages 417-424

Multi-ion quantitative mass spectrometry by orthogonal projection method with periodic signal of electrostatic ion beam trap

Author keywords

electrostatic ion beam trap (EIBT); fast Fourier transform (FFT); OPM mass spectrometry; orthogonal projection method (OPM); quantitative mass spectrometry

Indexed keywords

DELTA M; ION BEAM TRAPS; LOWER LIMITS; NUMERICAL MODELING; OPM MASS SPECTROMETRY; ORTHOGONAL PROJECTION METHOD; OSCILLATORY MOTION; PERIODIC CURRENT; PERIODIC SIGNAL; QUANTITATIVE ANALYSIS; QUANTITATIVE MASS SPECTROMETRY; QUANTITATIVE RESULT; RESOLVING POWER; SAMPLING TIME; TESTED SIGNALS; UPPER LIMITS;

EID: 79953170938     PISSN: 10765174     EISSN: 10969888     Source Type: Journal    
DOI: 10.1002/jms.1910     Document Type: Article
Times cited : (3)

References (21)
  • 4
    • 33646760633 scopus 로고    scopus 로고
    • Electrostatic linear ion trap for low-energy ion beam storage
    • T. Suzuki, Y. Yamauchi,. Electrostatic linear ion trap for low-energy ion beam storage. Nucl. Instrum. Meth. A 2006, 562, 53.
    • (2006) Nucl. Instrum. Meth. A , vol.562 , pp. 53
    • Suzuki, T.1    Yamauchi, Y.2
  • 15
    • 34548393210 scopus 로고    scopus 로고
    • Electrostatic ion trap and Fourier transform measurements for high-resolution mass spectrometry
    • K. G. Bhushan, S. C. Gadkari, J. V. Yakhmi, V. C. Sahni,. Electrostatic ion trap and Fourier transform measurements for high-resolution mass spectrometry. Rev. Sci. Instrum. 2007, 78, 083302.
    • (2007) Rev. Sci. Instrum. , vol.78 , pp. 083302
    • Bhushan, K.G.1    Gadkari, S.C.2    Yakhmi, J.V.3    Sahni, V.C.4
  • 16
    • 71749119777 scopus 로고    scopus 로고
    • Modeling and analysis of the induced signal detected in electrostatic ion beam trap for mass spectrometry
    • Q. Sun, C. X. Gu, L. Ding,. Modeling and analysis of the induced signal detected in electrostatic ion beam trap for mass spectrometry. Nucl. Instr. Meth. Phys. Res. A 2009, 609, 177.
    • (2009) Nucl. Instr. Meth. Phys. Res. A , vol.609 , pp. 177
    • Sun, Q.1    Gu, C.X.2    Ding, L.3
  • 17
    • 62849107161 scopus 로고    scopus 로고
    • Modeling and optimization of dual-cylinder image current detector in electrostatic ion beam trap for mass spectrometry
    • Q. Sun, C. X. Gu, L. Ding,. Modeling and optimization of dual-cylinder image current detector in electrostatic ion beam trap for mass spectrometry. Int. J. Mass Spectrom. 2009, 282, 38.
    • (2009) Int. J. Mass Spectrom. , vol.282 , pp. 38
    • Sun, Q.1    Gu, C.X.2    Ding, L.3
  • 18
    • 24944485400 scopus 로고    scopus 로고
    • A mapping approach to synchronization in the 'Zajfman trap': II. The observed bunch
    • T. Geyer, D. J. Tannor,. A mapping approach to synchronization in the 'Zajfman trap': II. The observed bunch. J. Phys. B: At. Mol. Opt. Phys. 2005, 38, 3423.
    • (2005) J. Phys. B: At. Mol. Opt. Phys. , vol.38 , pp. 3423
    • Geyer, T.1    Tannor, D.J.2
  • 19
    • 0037436582 scopus 로고    scopus 로고
    • Self-bunching induced by negative effective mass instability in an electrostatic ion beam trap
    • D. Strasser, O. Heber, S. Goldberg, D. Zajfman,. Self-bunching induced by negative effective mass instability in an electrostatic ion beam trap. J. Phys. B: At. Mol. Opt. Phys. 2003, 36, 953.
    • (2003) J. Phys. B: At. Mol. Opt. Phys. , vol.36 , pp. 953
    • Strasser, D.1    Heber, O.2    Goldberg, S.3    Zajfman, D.4
  • 21
    • 0004271915 scopus 로고    scopus 로고
    • Prentice Hall, Upper Saddle River, NJ
    • K. Hoffman, R. Kunze,. Linear Algebra, Prentice Hall, Upper Saddle River, NJ, 2008.
    • (2008) Linear Algebra
    • Hoffman, K.1    Kunze, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.