메뉴 건너뛰기




Volumn 26, Issue 2, 2011, Pages 159-165

Oxygenated hypothermic pulsatile perfusion versus cold static storage for kidneys from non heart-beating donors tested by in-line ATP resynthesis to establish a strategy of preservation

Author keywords

ATP production.; kidney viability assessment; non heart beating donors; nuclear magnetic resonance spectroscopy of 31P; oxygenated hypothermic pulsatile perfusion

Indexed keywords

ADENOSINE TRIPHOSPHATE;

EID: 79953116422     PISSN: 02676591     EISSN: None     Source Type: Journal    
DOI: 10.1177/0267659110387184     Document Type: Article
Times cited : (35)

References (28)
  • 4
    • 0027717672 scopus 로고
    • Pulsatile kidney perfusion for preservation and evaluation: Use of high- risk kidney donors to expand the donor pool
    • Tesi RJ, Elkhammas EA, Davies EA, Henry ML, Ferguson RM Pulsatile kidney perfusion for preservation and evaluation: use of high-risk kidney donors to expand the donor pool. Transplant Proc 1993. 25 (6). 3099-100. (Pubitemid 24007239)
    • (1993) Transplantation Proceedings , vol.25 , Issue.6 , pp. 3099-3100
    • Tesi, R.J.1    Elkhammas, E.A.2    Davies, E.A.3    Henry, M.L.4    Ferguson, R.M.5
  • 5
  • 6
    • 75149155208 scopus 로고    scopus 로고
    • Perfusion preservation of the donor heart: Basic science to pre-clinical
    • Rivard AL, Gallegos R., Ogden IM, Bianco RW Perfusion preservation of the donor heart: basic science to pre-clinical. J Extra Corpor Technol 2009 41 (3). 140-148.
    • (2009) J Extra Corpor Technol , vol.41 , Issue.3 , pp. 140-148
    • Rivard, A.L.1    Gallegos, R.2    Ogden, I.M.3    Bianco, R.W.4
  • 7
    • 80053304605 scopus 로고    scopus 로고
    • Pilot study assessing the feasibility of a short period of normothermic preservation in an experimental model of non heart beating donor kidneys
    • Hosgood SA, Barlow AD, Yates PJ, Snoeijs MG, van Heurn EL, Nicholson ML A pilot study assessing the feasibility of a short period of normothermic preservation in an experimental model of non heart beating donor kidneys. J Surg Res 2010 Feb 11. Epub ahead of print.
    • (2010) J Surg Res
    • Hosgood, S.A.1    Barlow, A.D.2    Yates, P.J.3    Snoeijs, M.G.4    Van Heurn, E.L.5    Nicholson, M.L.6
  • 8
    • 77952894549 scopus 로고    scopus 로고
    • Extracorporeal support: Improves donor renal graft function after cardiac death
    • Rojas-Pena A., Krause E., Boothman EL, et al. Extracorporeal support: improves donor renal graft function after cardiac death. Am J Transplant ; 10 (6). 1365-1374.
    • Am J Transplant , vol.10 , Issue.6 , pp. 1365-1374
    • Rojas-Pena, A.1    Krause, E.2    Boothman, E.L.3
  • 9
    • 34548396778 scopus 로고    scopus 로고
    • A new disposable perfusion machine, nuclear magnetic resonance compatible, to test the marginal organs and the kidneys from non-heart-beating donors before transplantation
    • DOI 10.1510/icvts.2006.146043
    • Buchs JB, Buhler L., Morel P. A new disposable perfusion machine, nuclear magnetic resonance compatible, to test the marginal organs and the kidneys from non-heart-beating donors before transplantation. Interact Cardiovasc Thorac Surg 2007 ; 6 (4). 421-424. (Pubitemid 47403920)
    • (2007) Interactive Cardiovascular and Thoracic Surgery , vol.6 , Issue.4 , pp. 421-424
    • Buchs, J.-B.1    Buhler, L.2    Morel, P.3
  • 11
    • 0025970756 scopus 로고
    • Application of P-31 nuclear magnetic resonance spectroscopy to a new experimental kidney perfusion model using cadaveric porcine kidneys from slaughterhouse
    • Lietzenmayer R., Henze E., Knorpp R., et al. Application of P-31 nuclear magnetic resonance spectroscopy to a new experimental kidney perfusion model using cadaveric porcine kidneys from slaughterhouse. Nephron 1991 ; 57 (3). 340-348.
    • (1991) Nephron , vol.57 , Issue.3 , pp. 340-348
    • Lietzenmayer, R.1    Henze, E.2    Knorpp, R.3
  • 12
    • 77952841443 scopus 로고    scopus 로고
    • A simplified approach to human islet quality assessment
    • Hanson MS, Park EE, Sears ML, et al. A simplified approach to human islet quality assessment. Transplantation 2010 ; 89 (10). 1178-1188.
    • (2010) Transplantation , vol.89 , Issue.10 , pp. 1178-1188
    • Hanson, M.S.1    Park, E.E.2    Sears, M.L.3
  • 13
    • 79953125076 scopus 로고    scopus 로고
    • Monitoring kidney viability before transplantation by means of 31P CSI and oxygenated hypothermic perfusion
    • Lazeyras F., et al., Monitoring kidney viability before transplantation by means of 31P CSI and oxygenated hypothermic perfusion. International Society of Magnetic Resonance in Medicine 2009. (Abstract)
    • (2009) International Society of Magnetic Resonance in Medicine
    • Lazeyras, F.1
  • 14
    • 79953071115 scopus 로고    scopus 로고
    • ATP resynthesis of pig kidneys during oxygenated hypothermic perfusion assessed by 31P CSI
    • (Abstract)
    • Lazeyras F, B.L., Hergt M., Vallee J., Nastasi A., Rutimann R., Morel P., Buchs JB ATP resynthesis of pig kidneys during oxygenated hypothermic perfusion assessed by 31P CSI. ESMRMB 2008: p. 458. (Abstract)
    • (2008) ESMRMB , pp. 458
    • Lazeyras, F.B.L.1    Hergt, M.2    Vallee, J.3    Nastasi, A.4    Rutimann, R.5    Morel, P.6    Buchs, J.B.7
  • 18
    • 0028178482 scopus 로고
    • 31P nuclear magnetic resonance spectroscopic evaluation of liver preservation solutions
    • Bowers JL, Neymark E., Cook CU, Clouse ME 31P nuclear magnetic resonance spectroscopic evaluation of liver preservation solutions. Transplantation 1994 ; 57 (11). 1576-1580.
    • (1994) Transplantation , vol.57 , Issue.11 , pp. 1576-1580
    • Bowers, J.L.1    Neymark, E.2    Cook, C.U.3    Clouse, M.E.4
  • 19
    • 0022980988 scopus 로고
    • Nuclear magnetic resonance assessment of renal perfusion and preservation for transplantation
    • Chin JL, CR Stiller, Karlik SJ Nuclear magnetic resonance assessment of renal perfusion and preservation for transplantation. J Urol 1986 ; 136 (6). 1351-1355. (Pubitemid 17189229)
    • (1986) Journal of Urology , vol.136 , Issue.6 , pp. 1351-1355
    • Chin, J.L.1    Stiller, C.R.2    Karlik, S.J.3
  • 20
    • 0028037435 scopus 로고
    • Pre-transplantation assessment of renal viability with 31P magnetic resonance spectroscopy
    • Hene RJ, van der Grond J., Boer WH, Mali WP, Koomans HA Pre-transplantation assessment of renal viability with 31P magnetic resonance spectroscopy. Kidney Int 1994 ; 46 (6). 1694-1699.
    • (1994) Kidney Int , vol.46 , Issue.6 , pp. 1694-1699
    • Hene, R.J.1    Van Der Grond, J.2    Boer, W.H.3    Mali, W.P.4    Koomans, H.A.5
  • 21
    • 0024840558 scopus 로고
    • Phosphorus-31 MRS of the kidney
    • Hricak H. Phosphorus-31 MRS of the kidney. Invest Radiol 1989 ; 24 (12). 993-996.
    • (1989) Invest Radiol , vol.24 , Issue.12 , pp. 993-996
    • Hricak, H.1
  • 22
    • 0029421373 scopus 로고
    • Potential of 31P magnetic resonance spectroscopy in monitoring the viability of human renal grafts stored in Euro-Collins perfusion solution
    • Kurkova D., Herynek V., Gintelová J., Táborský P., Hájek M. Potential of 31P magnetic resonance spectroscopy in monitoring the viability of human renal grafts stored in Euro-Collins perfusion solution. Physiol Res 1995 ; 44 (5). 327-332.
    • (1995) Physiol Res , vol.44 , Issue.5 , pp. 327-332
    • Kurkova, D.1    Herynek, V.2    Gintelová, J.3    Táborský, P.4    Hájek, M.5
  • 23
    • 0023546133 scopus 로고
    • Inability to maintain adenine nucleotide levels by cold storage in ischemically damaged and control kidneys
    • Maessen JG, Van der Vusse GJ, Vork M., Kootstra G. Inability to maintain adenine nucleotide levels by cold storage in ischemically damaged and control kidneys. Transplant Proc 1987 ; 19 (5). 4112-4115. (Pubitemid 18023901)
    • (1987) Transplantation Proceedings , vol.19 , Issue.5 , pp. 4112-4115
    • Maessen, J.G.1    Van Der Vusse, G.J.2    Vork, M.3    Kootstra, G.4
  • 26
    • 4143101420 scopus 로고    scopus 로고
    • A comparison of renal preservation by cold storage and machine perfusion using a porcine autotransplant model
    • DOI 10.1097/01.TP.0000128634.03233.15
    • Nicholson ML, Hosgood SA, Metcalfe MS, Waller JR, Brook NR A comparison of renal preservation by cold storage and machine perfusion using a porcine autotransplant model. Transplantation 2004 ; 78 (3). 333-337. (Pubitemid 39095397)
    • (2004) Transplantation , vol.78 , Issue.3 , pp. 333-337
    • Nicholson, M.L.1    Hosgood, S.A.2    Metcalfe, M.S.3    Waller, J.R.4    Brook, N.R.5
  • 27
    • 58249089430 scopus 로고    scopus 로고
    • Machine perfusion or cold storage in deceased-donor kidney transplantation
    • Moers C., Smits JM, Maathuis MH, et al. Machine perfusion or cold storage in deceased-donor kidney transplantation. N Engl J Med 2009 ; 360 (1). 7-19.
    • (2009) N Engl J Med , vol.360 , Issue.1 , pp. 7-19
    • Moers, C.1    Smits, J.M.2    Maathuis, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.