메뉴 건너뛰기




Volumn 4, Issue 6, 2010, Pages 1479-1494

Estimates of total analytical error in consumer and hospital glucose meters contributed by hematocrit, maltose, and ascorbate

Author keywords

Ascorbate; Bias; Glucose meters; Hematocrit; Imprecision; Interference; Maltose; Total error

Indexed keywords

ASCORBIC ACID; BIOLOGICAL MARKER; MALTOSE;

EID: 79952996013     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681000400624     Document Type: Article
Times cited : (21)

References (24)
  • 1
    • 34249902075 scopus 로고    scopus 로고
    • Assessing the quality of glucose monitor studies: A critical evaluation of published reports
    • Mahoney J, Ellison J. Assessing the quality of glucose monitor studies: a critical evaluation of published reports. Clin Chem. 2007;53(6):1122-8.
    • (2007) Clin Chem , vol.53 , Issue.6 , pp. 1122-1128
    • Mahoney, J.1    Ellison, J.2
  • 2
    • 77951733801 scopus 로고    scopus 로고
    • A review of standards and statistics used to describe blood glucose monitor performance
    • Krouwer JS, Cembrowski GS. A review of standards and statistics used to describe blood glucose monitor performance. J Diabetes Sci Technol. 2010;4(1):75-83.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.1 , pp. 75-83
    • Krouwer, J.S.1    Cembrowski, G.S.2
  • 3
    • 36348960172 scopus 로고    scopus 로고
    • Assessing glucose monitor performance - A standardized approach
    • Mahoney JJ, Ellison JM. Assessing glucose monitor performance - a standardized approach. Diabetes Technol Ther. 2007;9(6):545-52.
    • (2007) Diabetes Technol Ther , vol.9 , Issue.6 , pp. 545-552
    • Mahoney, J.J.1    Ellison, J.M.2
  • 4
    • 77953703130 scopus 로고    scopus 로고
    • A mathematical model to assess the influence of hematocrit on point of care glucose meter performance
    • Lyon ME, Gray D, Baskin LB, Dubois JA, Lyon AW. A mathematical model to assess the influence of hematocrit on point of care glucose meter performance. Clin Biochem. 2010;43(10-11):905-9.
    • (2010) Clin Biochem , vol.43 , Issue.10-11 , pp. 905-909
    • Lyon, M.E.1    Gray, D.2    Baskin, L.B.3    Dubois, J.A.4    Lyon, A.W.5
  • 5
    • 78349287412 scopus 로고    scopus 로고
    • The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors
    • Klonoff DC. The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors. J Diabetes Sci Technol. 2010;4(3):499-504.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.3 , pp. 499-504
    • Klonoff, D.C.1
  • 6
    • 74549198676 scopus 로고    scopus 로고
    • Managing quality vs. Measuring uncertainty in the medical laboratory
    • Westgard JO. Managing quality vs. measuring uncertainty in the medical laboratory. Clin Chem Lab Med. 2010;48(1):31-40.
    • (2010) Clin Chem Lab Med , vol.48 , Issue.1 , pp. 31-40
    • Westgard, J.O.1
  • 11
    • 0025367052 scopus 로고
    • Direct reading glucose electrodes detect the molality of glucose in plasma and whole blood
    • Fogh-Andersen N, Wimberley PD, Thode J, Siggaard-Andersen O. Direct reading glucose electrodes detect the molality of glucose in plasma and whole blood. Clin Chim Acta 1990;189(1):33-8.
    • (1990) Clin Chim Acta , vol.189 , Issue.1 , pp. 33-38
    • Fogh-Andersen, N.1    Wimberley, P.D.2    Thode, J.3    Siggaard-Andersen, O.4
  • 13
    • 0031937316 scopus 로고    scopus 로고
    • Proposal for standardizing direct-reading biosensors for blood glucose
    • Fogh-Andersen N, D'Orazio P. Proposal for standardizing direct-reading biosensors for blood glucose. Clin Chem. 1998;44(3):655-9.
    • (1998) Clin Chem , vol.44 , Issue.3 , pp. 655-659
    • Fogh-Andersen, N.1    D'Orazio, P.2
  • 14
    • 70349495829 scopus 로고    scopus 로고
    • Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: An overview
    • Floré KM, Delanghe JR. Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview. Perit Dial Int. 2009;29(4):377-83.
    • (2009) Perit Dial Int , vol.29 , Issue.4 , pp. 377-383
    • Floré, K.M.1    Delanghe, J.R.2
  • 15
    • 77957671112 scopus 로고    scopus 로고
    • False elevation of blood glucose levels measured by GDH-PQQ-based glucometers occurs during all daily dwells in peritoneal dialysis patients using icodextrin
    • Tsai CY, Lee SC, Hung CC, Lee JJ, Kuo MC, Hwang SJ, Chen HC. False elevation of blood glucose levels measured by GDH-PQQ-based glucometers occurs during all daily dwells in peritoneal dialysis patients using icodextrin. Perit Dial Int. 2010;30(3):329-35.
    • (2010) Perit Dial Int , vol.30 , Issue.3 , pp. 329-335
    • Tsai, C.Y.1    Lee, S.C.2    Hung, C.C.3    Lee, J.J.4    Kuo, M.C.5    Hwang, S.J.6    Chen, H.C.7
  • 16
    • 60849131272 scopus 로고    scopus 로고
    • Differences in glucose values obtained from point-of-care glucose meters and laboratory analysis in critically ill patients
    • Cook A, Laughlin D, Moore M, North D, Wilkins K, Wong G, Wallace-Scroggs A, Halvorsen L. Differences in glucose values obtained from point-of-care glucose meters and laboratory analysis in critically ill patients. Am J Crit Care. 2009;18(1):65-71.
    • (2009) Am J Crit Care , vol.18 , Issue.1 , pp. 65-71
    • Cook, A.1    Laughlin, D.2    Moore, M.3    North, D.4    Wilkins, K.5    Wong, G.6    Wallace-Scroggs, A.7    Halvorsen, L.8
  • 18
    • 85039640667 scopus 로고    scopus 로고
    • Pediatric hematocrit distribution in an acute-care hospital versus community setting
    • Baskin L, Gray D, Lyon ME. Pediatric hematocrit distribution in an acute-care hospital versus community setting. Clin Chem. 2008;54/6(Supplement): A195, E133.
    • (2008) Clin Chem , vol.54 , Issue.6 SUPPL.
    • Baskin, L.1    Gray, D.2    Lyon, M.E.3
  • 19
    • 25144512065 scopus 로고    scopus 로고
    • Serum ascorbic acid concentration in patients with acute Falciparum malaria infection: Possible significance
    • Hassan GI, Gregory U, Maryam H. Serum ascorbic acid concentration in patients with acute Falciparum malaria infection: possible significance. Braz J Infect Dis. 2004;8(5):378-81.
    • (2004) Braz J Infect Dis , vol.8 , Issue.5 , pp. 378-381
    • Hassan, G.I.1    Gregory, U.2    Maryam, H.3
  • 20
    • 84887343342 scopus 로고    scopus 로고
    • Serum L-ascorbic acid concentration and its potential for scavenging of reactive oxygen species in acute, uncomplicated, falciparum malaria infection
    • about Available from: Accessed June 1, 2010
    • Garba IH, Abraham IG, Shuaibu U. Serum L-ascorbic acid concentration and its potential for scavenging of reactive oxygen species in acute, uncomplicated, falciparum malaria infection. Internet J Infect Dis. 2006;5(2):[about 7 p.]. Available from: http://www.ispub.com/ostia/index.php?xmlFilePath=journals/ijid/ vol5n2/malaria.xml. Accessed June 1, 2010.
    • (2006) Internet J Infect Dis , vol.5 , Issue.2 , pp. 7
    • Garba, I.H.1    Abraham, I.G.2    Shuaibu, U.3
  • 23
    • 0035130886 scopus 로고    scopus 로고
    • Quality specifications for glucose meters: Assessment by simulation modeling of errors in insulin dose
    • Boyd JC, Bruns DE. Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose. Clin Chem. 2001;47(2):209-14.
    • (2001) Clin Chem , vol.47 , Issue.2 , pp. 209-214
    • Boyd, J.C.1    Bruns, D.E.2
  • 24
    • 78149382135 scopus 로고    scopus 로고
    • Impact of blood glucose self-monitoring error on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: An in silico study
    • Breton MD, Kovatchev BP. Impact of blood glucose self-monitoring error on glucose variability, risk for hypoglycemia, and average glucose control in type 1 diabetes: an in silico study. J Diabetes Sci Technol. 2010;4(3):562-70.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.3 , pp. 562-570
    • Breton, M.D.1    Kovatchev, B.P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.