메뉴 건너뛰기




Volumn 22, Issue 1, 2011, Pages 130-137

An external matrix-assisted laser desorption ionization source for flexible ft-icr mass spectrometry imaging with internal calibration on adjacent samples

Author keywords

Fourier transform; FTMS; Imaging mass spectrometry; INCAS; Ion cyclotron resonance

Indexed keywords

CALIBRANTS; FT-ICR MASS SPECTROMETRY; FT-ICR MS; FTMS; IMAGING EXPERIMENTS; IMAGING MASS SPECTROMETRY; INCAS; INTERNAL CALIBRATION; ION CYCLOTRON RESONANCE; ION EJECTION; ION TRAPS; LC-MALDI; MASS SELECTION; MASS SPECTRA; MATRIX-ASSISTED LASER DESORPTION IONIZATION; NEW SOURCES; POSITIONING STAGE; POTENTIAL GRADIENTS; QUADRUPOLES; RANGE OF MOTIONS; RAT BRAIN;

EID: 79952517006     PISSN: 10440305     EISSN: 18791123     Source Type: Journal    
DOI: 10.1007/s13361-010-0003-x     Document Type: Article
Times cited : (24)

References (89)
  • 1
    • 33846888780 scopus 로고    scopus 로고
    • MALDI-MS-based imaging of small molecules and proteins in tissues
    • Reyzer, M.L., Caprioli, R.M.: MALDI-MS-based imaging of small molecules and proteins in tissues. Curr. Opin. Chem. Biol. 11(1), 29-35 (2007)
    • (2007) Curr. Opin. Chem. Biol. , vol.11 , Issue.1 , pp. 29-35
    • Reyzer, M.L.1    Caprioli, R.M.2
  • 4
    • 0034142048 scopus 로고    scopus 로고
    • Subcellular imaging by dynamic SIMS ion microscopy
    • Chandra, S., Smith, D.R., Morrison, G.H.: Subcellular imaging by dynamic SIMS ion microscopy. Anal. Chem. 72(3), 104a-114a (2000)
    • (2000) Anal. Chem. , vol.72 , Issue.3
    • Chandra, S.1    Smith, D.R.2    Morrison, G.H.3
  • 5
    • 0037438034 scopus 로고    scopus 로고
    • SIMS ion microscopy as a novel. Practical tool for subcellular chemical imaging in cancer research
    • Chandra, S.: SIMS ion microscopy as a novel. Practical tool for subcellular chemical imaging in cancer research. Appl. Surf. Sci. 203, 679-683 (2003)
    • (2003) Appl. Surf. Sci. , vol.203 , pp. 679-683
    • Chandra, S.1
  • 7
    • 13244277655 scopus 로고    scopus 로고
    • Direct molecular imaging of lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry
    • Altelaar, A.F.M., van Minnen, J., Jimenez, C.R., Heeren, R.M.A., Piersma, S.R.: Direct molecular imaging of lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry. Anal. Chem. 77(3), 735-741 (2005)
    • (2005) Anal. Chem. , vol.77 , Issue.3 , pp. 735-741
    • Altelaar, A.F.M.1    Van Minnen, J.2    Jimenez, C.R.3    Heeren, R.M.A.4    Piersma, S.R.5
  • 9
  • 11
    • 34247477267 scopus 로고    scopus 로고
    • Instrument design and characterization for high resolution MALDI-MS imaging of tissue sections
    • Chaurand, P., Schriver, K.E., Caprioli, R.M.: Instrument design and characterization for high resolution MALDI-MS imaging of tissue sections. J. Mass Spectrom. 42(4), 476-489 (2007)
    • (2007) J. Mass Spectrom. , vol.42 , Issue.4 , pp. 476-489
    • Chaurand, P.1    Schriver, K.E.2    Caprioli, R.M.3
  • 13
    • 56749095307 scopus 로고    scopus 로고
    • Imaging subcellular features of a sectioned rat brain using time-of-flight secondary ion mass spectrometry and scanning probe microscopy
    • Nie, H.Y., Francis, J.T., Taylor, A.R., Walzak, M.J., Chang, W.H., MacFabe, D.F., Lau, W.M.: Imaging subcellular features of a sectioned rat brain using time-of-flight secondary ion mass spectrometry and scanning probe microscopy. Appl. Surf. Sci. 255(4), 1079-1083 (2008)
    • (2008) Appl. Surf. Sci. , vol.255 , Issue.4 , pp. 1079-1083
    • Nie, H.Y.1    Francis, J.T.2    Taylor, A.R.3    Walzak, M.J.4    Chang, W.H.5    MacFabe, D.F.6    Lau, W.M.7
  • 14
    • 0031623267 scopus 로고    scopus 로고
    • Fourier transform ion cyclotron resonance mass spectrometry: A primer
    • Marshall, A.G., Hendrickson, C.L., Jackson, G.S.: Fourier transform ion cyclotron resonance mass spectrometry: a primer. Mass Spectrom. Rev. 17(1), 1-35 (1998)
    • (1998) Mass Spectrom. Rev. , vol.17 , Issue.1 , pp. 1-35
    • Marshall, A.G.1    Hendrickson, C.L.2    Jackson, G.S.3
  • 15
    • 0041408938 scopus 로고    scopus 로고
    • Electrostatic axially harmonic orbital trapping: A high-performance technique of mass analysis
    • Makarov, A.: Electrostatic axially harmonic orbital trapping: a high-performance technique of mass analysis. Anal. Chem. 72(6), 1156-1162 (2000)
    • (2000) Anal. Chem. , vol.72 , Issue.6 , pp. 1156-1162
    • Makarov, A.1
  • 17
    • 49049113308 scopus 로고    scopus 로고
    • MALDI-FTICR imaging mass spectrometry of drugs and metabolites in tissue
    • Cornett, D.S., Frappier, S.L., Caprioli, R.M.: MALDI-FTICR imaging mass spectrometry of drugs and metabolites in tissue. Anal. Chem. 80(14), 5648-5653 (2008)
    • (2008) Anal. Chem. , vol.80 , Issue.14 , pp. 5648-5653
    • Cornett, D.S.1    Frappier, S.L.2    Caprioli, R.M.3
  • 18
    • 70449794095 scopus 로고    scopus 로고
    • Imaging of lipids in spinal cord using intermediate pressure matrix-assisted laser desorption-linear ion trap/Orbitrap MS
    • Landgraf, R.R., Prieto Conaway, M.C., Garrett, T.J., Stacpoole, P.W., Yost, R.A.: Imaging of lipids in spinal cord using intermediate pressure matrix-assisted laser desorption-linear ion trap/Orbitrap MS. Anal. Chem. 81(20), 8488-8495 (2009)
    • (2009) Anal. Chem. , vol.81 , Issue.20 , pp. 8488-8495
    • Landgraf, R.R.1    Prieto Conaway, M.C.2    Garrett, T.J.3    Stacpoole, P.W.4    Yost, R.A.5
  • 19
    • 70450059685 scopus 로고    scopus 로고
    • Automated ambient desorption-ionization platform for surface imaging integrated with a commercial Fourier transform ion cyclotron resonance mass spectrometer
    • Pól, J., Vidová, V., Kruppa, G., Kobliha, V., Novák, P., Lemr, K., Kotiaho, T., Kostiainen, R., Havlíček, V., Volný, M.: Automated ambient desorption-ionization platform for surface imaging integrated with a commercial Fourier transform ion cyclotron resonance mass spectrometer. Anal. Chem. 81(20), 8479-8487 (2009)
    • (2009) Anal. Chem. , vol.81 , Issue.20 , pp. 8479-8487
    • Pól, J.1    Vidová, V.2    Kruppa, G.3    Kobliha, V.4    Novák, P.5    Lemr, K.6    Kotiaho, T.7    Kostiainen, R.8    Havlíček, V.9    Volný, M.10
  • 20
    • 84984020126 scopus 로고
    • Laser microprobe Fourier transform mass spectrometry. Preliminary results for feasibility and evaluation
    • Pelletier, M., Kreier, G., Muller, J.F., Weil, D., Johnston, M., MarshalI, A. G.: Laser microprobe Fourier transform mass spectrometry. preliminary results for feasibility and evaluation. Rapid Commun. Mass Spectrom. 2(7), 146-150 (1988)
    • (1988) Rapid Commun. Mass Spectrom. , vol.2 , Issue.7 , pp. 146-150
    • Pelletier, M.1    Kreier, G.2    Muller, J.F.3    Weil, D.4    Johnston, M.5    MarshalI, A.G.6
  • 21
    • 0001405029 scopus 로고
    • Nd-YAG laser microprobe system for Fourier-transform ion-cyclotron resonance mass-spectrometry
    • Brenna, J.T., Creasy, W.R., McBain, W., Soria, C.: Nd-YAG laser microprobe system for Fourier-transform ion-cyclotron resonance mass-spectrometry. Rev. Sci. Instrum. 59(6), 873-879 (1988)
    • (1988) Rev. Sci. Instrum. , vol.59 , Issue.6 , pp. 873-879
    • Brenna, J.T.1    Creasy, W.R.2    McBain, W.3    Soria, C.4
  • 22
    • 0000580298 scopus 로고    scopus 로고
    • Microscopic laser desorption postionization Fourier transform mass spectrometry
    • Behm, J.M., Hemminger, J.C., Lykke, K.R.: Microscopic laser desorption postionization Fourier transform mass spectrometry. Anal. Chem. 68(5), 713-719 (1996)
    • (1996) Anal. Chem. , vol.68 , Issue.5 , pp. 713-719
    • Behm, J.M.1    Hemminger, J.C.2    Lykke, K.R.3
  • 23
    • 0036494694 scopus 로고    scopus 로고
    • Highly reproducible laser beam scanning device for an internal source laser desorption microprobe Fourier transform mass spectrometer
    • Scott, J.R., Tremblay, P.L.: Highly reproducible laser beam scanning device for an internal source laser desorption microprobe Fourier transform mass spectrometer. Rev. Sci. Instrum. 73(3), 1108-1116 (2002)
    • (2002) Rev. Sci. Instrum. , vol.73 , Issue.3 , pp. 1108-1116
    • Scott, J.R.1    Tremblay, P.L.2
  • 24
    • 54049157850 scopus 로고    scopus 로고
    • Exploring biosignatures associated with thenardite by geomatrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (GALDI-FTICR-MS)
    • Richardson, C.D., Hinman, N.W., McJunkin, T.R., Kotler, J.M., Scott, J.R.: Exploring biosignatures associated with thenardite by geomatrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (GALDI-FTICR-MS). Geomicrobiol. J. 25(7-8), 432-440 (2008)
    • (2008) Geomicrobiol. J. , vol.25 , Issue.7-8 , pp. 432-440
    • Richardson, C.D.1    Hinman, N.W.2    McJunkin, T.R.3    Kotler, J.M.4    Scott, J.R.5
  • 25
    • 84990727056 scopus 로고
    • Development of a laser microprobe Fourier-transform mass-spectrometer with external ion-source
    • Vanvaeck, L., Vanroy, W., Struyf, H., Adams, F., Caravatti, P.: Development of a laser microprobe Fourier-transform mass-spectrometer with external ion-source. Rapid Commun. Mass Spectrom. 7(5), 323-331 (1993)
    • (1993) Rapid Commun. Mass Spectrom. , vol.7 , Issue.5 , pp. 323-331
    • Vanvaeck, L.1    Vanroy, W.2    Struyf, H.3    Adams, F.4    Caravatti, P.5
  • 26
    • 0027432413 scopus 로고
    • Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis
    • Struyf, H., Van Roy, W., Van Vaeck, L., Van Griecken, R., Gijbels, R., Caravatti, P.: Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis. Anal. Chim. Acta 283(1), 139-151 (1993)
    • (1993) Anal. Chim. Acta , vol.283 , Issue.1 , pp. 139-151
    • Struyf, H.1    Van Roy, W.2    Van Vaeck, L.3    Van Griecken, R.4    Gijbels, R.5    Caravatti, P.6
  • 28
    • 0013431655 scopus 로고
    • UV laser matrix desorption ionization mass-spectrometry of proteins in the 100 000 dalton range
    • Karas, M., Bahr, U., Hillenkamp, F.: UV laser matrix desorption ionization mass-spectrometry of proteins in the 100 000 dalton range. Int. J. Mass Spectrom. Ion Process. 92, 231-242 (1989)
    • (1989) Int. J. Mass Spectrom. Ion Process. , vol.92 , pp. 231-242
    • Karas, M.1    Bahr, U.2    Hillenkamp, F.3
  • 29
    • 84875463071 scopus 로고
    • Matrix-assisted laser desorption ionization mass-spectrometry of biopolymers
    • Hillenkamp, F., Karas, M., Beavis, R.C., Chait, B.T.: Matrix-assisted laser desorption ionization mass-spectrometry of biopolymers. Anal. Chem. 63(24), A1193-A1202 (1991)
    • (1991) Anal. Chem. , vol.63 , Issue.24
    • Hillenkamp, F.1    Karas, M.2    Beavis, R.C.3    Chait, B.T.4
  • 30
    • 0032503987 scopus 로고    scopus 로고
    • Infrared MALDI mass spectrometry of large nucleic acids
    • Berkenkamp, S., Kirpekar, F., Hillenkamp, F.: Infrared MALDI mass spectrometry of large nucleic acids. Science 281(5374), 260-262 (1998)
    • (1998) Science , vol.281 , Issue.5374 , pp. 260-262
    • Berkenkamp, S.1    Kirpekar, F.2    Hillenkamp, F.3
  • 31
    • 0001925156 scopus 로고
    • Analysis of copolymers by laser desorption Fourier-transformmass- spectrometry
    • Nuwaysir, L.M., Wilkins, C.L., Simonsick, W.J.: Analysis of copolymers by laser desorption Fourier-transformmass-spectrometry. J. Am. Soc. Mass Spectrom. 1(1), 66-71 (1990)
    • (1990) J. Am. Soc. Mass Spectrom. , vol.1 , Issue.1 , pp. 66-71
    • Nuwaysir, L.M.1    Wilkins, C.L.2    Simonsick, W.J.3
  • 32
    • 84989103799 scopus 로고
    • Matrix-assisted laser desorption at visible wavelengths using a 2-component matrix
    • Cornett, D.S., Duncan, M.A., Amster, I.J.: Matrix-assisted laser desorption at visible wavelengths using a 2-component matrix. Org. Mass Spectrom. 27(7), 831-832 (1992)
    • (1992) Org. Mass Spectrom. , vol.27 , Issue.7 , pp. 831-832
    • Cornett, D.S.1    Duncan, M.A.2    Amster, I.J.3
  • 33
    • 0027676314 scopus 로고
    • Ultrahigh-resolution matrix-assisted laser-desorption ionization of small proteins by Fourier-transform mass-spectrometry
    • Castoro, J.A., Wilkins, C.L.: Ultrahigh-resolution matrix-assisted laser-desorption ionization of small proteins by Fourier-transform mass-spectrometry. Anal. Chem. 65(19), 2621-2627 (1993)
    • (1993) Anal. Chem. , vol.65 , Issue.19 , pp. 2621-2627
    • Castoro, J.A.1    Wilkins, C.L.2
  • 34
    • 0027289080 scopus 로고
    • Protein molecular-weight determinations by MALD mass-spectrometry: A superior alternative to gel-filtration
    • Smith, E.T., Cornett, D.S., Amster, I.J., Adams, M.W.W.: Protein molecular-weight determinations by MALD mass-spectrometry: a superior alternative to gel-filtration. Anal. Biochem. 209(2), 379-380 (1993)
    • (1993) Anal. Biochem. , vol.209 , Issue.2 , pp. 379-380
    • Smith, E.T.1    Cornett, D.S.2    Amster, I.J.3    Adams, M.W.W.4
  • 36
    • 0028500130 scopus 로고
    • Detection limits formatrix-assisted laser-desorption of polypeptides with an external ion-source Fourier-transform mass-spectrometer
    • Li, Y.Z., McIver, R.T.: Detection limits formatrix-assisted laser-desorption of polypeptides with an external ion-source Fourier-transform mass-spectrometer. Rapid Commun. Mass Spectrom. 8(9), 743-749 (1994)
    • (1994) Rapid Commun. Mass Spectrom. , vol.8 , Issue.9 , pp. 743-749
    • Li, Y.Z.1    McIver, R.T.2
  • 37
    • 0028363368 scopus 로고
    • High-resolution laser-desorption mass-spectrometry of peptides and small proteins
    • McIver, R.T., Li, Y.Z., Hunter, R.L.: High-resolution laser-desorption mass-spectrometry of peptides and small proteins. Proc. Natl Acad. Sci. U.S.A. 91(11), 4801-4805 (1994)
    • (1994) Proc. Natl Acad. Sci. U.S.A. , vol.91 , Issue.11 , pp. 4801-4805
    • McIver, R.T.1    Li, Y.Z.2    Hunter, R.L.3
  • 38
    • 0029188043 scopus 로고
    • Endgroup analysis of polyethylene glycol polymers by matrix-assisted laser desorption/ionization Fourier-transform ion cyclotron resonance mass spectrometry
    • de Koster, C.G., Duursma, M.C., van Rooij, G.J., Heeren, R.M.A., Boon, J.J.: Endgroup analysis of polyethylene glycol polymers by matrix-assisted laser desorption/ionization Fourier-transform ion cyclotron resonance mass spectrometry. Rapid Commun. Mass Spectrom. 9(10), 957-962 (1995)
    • (1995) Rapid Commun. Mass Spectrom. , vol.9 , Issue.10 , pp. 957-962
    • De Koster, C.G.1    Duursma, M.C.2    Van Rooij, G.J.3    Heeren, R.M.A.4    Boon, J.J.5
  • 39
    • 0000695549 scopus 로고    scopus 로고
    • Rapid microscale analyses with an external ion source Fourier transform ion cyclotron resonance mass spectrometer
    • Heeren, R.M.A., Boon, J.J.: Rapid microscale analyses with an external ion source Fourier transform ion cyclotron resonance mass spectrometer. Int. J. Mass Spectrom. 157, 391-403 (1996)
    • (1996) Int. J. Mass Spectrom. , vol.157 , pp. 391-403
    • Heeren, R.M.A.1    Boon, J.J.2
  • 40
    • 0001417489 scopus 로고    scopus 로고
    • Correction of time-of-flight shifted polymeric molecular weight distributions in matrix assisted laser desorption/ionization Fourier transform mass spectrometry
    • O'Connor, P.B., Duursma, M.C.: vanRooij, G. J., Heeren, R. M. A. Boon, J. J.: Correction of time-of-flight shifted polymeric molecular weight distributions in matrix assisted laser desorption/ionization Fourier transform mass spectrometry. Anal. Chem. 69(14), 2751-2755 (1997)
    • (1997) Anal. Chem. , vol.69 , Issue.14 , pp. 2751-2755
    • O'Connor, P.B.1    Duursma, M.C.2    VanRooij, G.J.3    Heeren, R.M.A.4    Boon, J.J.5
  • 41
    • 0001211895 scopus 로고    scopus 로고
    • Application of matrix-assisted laser desorption/ionization Fourier transform mass spectrometry to the analysis of planar porphyrins and highly substituted nonplanar porphyrins
    • Green, M.K., Medforth, C.J., Muzzi, C.M., Nurco, D.J., Shea, K.M., Smith, K.M., Lebrilla, C.B., Shelnutt, J.A.: Application of matrix-assisted laser desorption/ionization Fourier transform mass spectrometry to the analysis of planar porphyrins and highly substituted nonplanar porphyrins. Eur. Mass Spectrom. 3(6), 439-451 (1997)
    • (1997) Eur. Mass Spectrom. , vol.3 , Issue.6 , pp. 439-451
    • Green, M.K.1    Medforth, C.J.2    Muzzi, C.M.3    Nurco, D.J.4    Shea, K.M.5    Smith, K.M.6    Lebrilla, C.B.7    Shelnutt, J.A.8
  • 42
    • 0033932281 scopus 로고    scopus 로고
    • Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry with pulsed in-source collision gas and in-source ion accumulation
    • Baykut, G., Jertz, R., Witt, M.: Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry with pulsed in-source collision gas and in-source ion accumulation. Rapid Commun. Mass Spectrom. 14(14), 1238-1247 (2000)
    • (2000) Rapid Commun. Mass Spectrom. , vol.14 , Issue.14 , pp. 1238-1247
    • Baykut, G.1    Jertz, R.2    Witt, M.3
  • 43
    • 0034815122 scopus 로고    scopus 로고
    • A high pressure matrix-assisted laser desorption/ionization Fourier transform mass spectrometry ion source for thermal stabilization of labile biomolecules
    • O'Connor, P.B., Costello, C.E.: A high pressure matrix-assisted laser desorption/ionization Fourier transform mass spectrometry ion source for thermal stabilization of labile biomolecules. Rapid Commun. Mass Spectrom. 15(19), 1862-1868 (2001)
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , Issue.19 , pp. 1862-1868
    • O'Connor, P.B.1    Costello, C.E.2
  • 44
    • 0036023983 scopus 로고    scopus 로고
    • A combined ion source for fast switching between electrospray and matrix-assisted laser desorption ionization in Fourier transform ion cyclotron resonance mass spectrometry
    • Baykut, G., Fuchser, J., Witt, M., Weiss, G., Gosteli, C.: A combined ion source for fast switching between electrospray and matrix-assisted laser desorption ionization in Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun. Mass Spectrom. 16(17), 1631-1641 (2002)
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , Issue.17 , pp. 1631-1641
    • Baykut, G.1    Fuchser, J.2    Witt, M.3    Weiss, G.4    Gosteli, C.5
  • 45
    • 0345862096 scopus 로고    scopus 로고
    • A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces
    • O'Connor, P.B., Budnik, B.A., Ivleva, V.B., Kaur, P., Moyer, S.C., Pittman, J.L., Costello, C.E.: A high pressure matrix-assisted laser desorption ion source for Fourier transform mass spectrometry designed to accommodate large targets with diverse surfaces. J. Am. Soc. Mass Spectrom. 15(1), 128-132 (2004)
    • (2004) J. Am. Soc. Mass Spectrom. , vol.15 , Issue.1 , pp. 128-132
    • O'Connor, P.B.1    Budnik, B.A.2    Ivleva, V.B.3    Kaur, P.4    Moyer, S.C.5    Pittman, J.L.6    Costello, C.E.7
  • 46
    • 4744365192 scopus 로고    scopus 로고
    • In situ tissue analysis of neuropeptides by MALDI FTMS in-cell accumulation
    • Kutz, K.K., Schmidt, J.J., Li, L.J.: In situ tissue analysis of neuropeptides by MALDI FTMS in-cell accumulation. Anal. Chem. 76(19), 5630-5640 (2004)
    • (2004) Anal. Chem. , vol.76 , Issue.19 , pp. 5630-5640
    • Kutz, K.K.1    Schmidt, J.J.2    Li, L.J.3
  • 47
    • 34247527329 scopus 로고    scopus 로고
    • Mass spectrometric identification of pEGFYSQRYamide: A crustacean peptide hormone possessing a vertebrate neuropeptide Y (NPY)-like carboxy-terminus
    • Stemmler, E.A., Bruns, E.A., Gardner, N.P., Dickinson, P.S., Christie, A.E.: Mass spectrometric identification of pEGFYSQRYamide: a crustacean peptide hormone possessing a vertebrate neuropeptide Y (NPY)-like carboxy-terminus. Gen. Comp. Endocrinol. 152(1), 1-7 (2007)
    • (2007) Gen. Comp. Endocrinol. , vol.152 , Issue.1 , pp. 1-7
    • Stemmler, E.A.1    Bruns, E.A.2    Gardner, N.P.3    Dickinson, P.S.4    Christie, A.E.5
  • 48
    • 35348941126 scopus 로고    scopus 로고
    • High-mass-resolution direct-tissue MALDI-FTMS reveals broad conservation of three neuropeptides (APSGFLGMRamide, GYRKPPFNGSIFamide and pQDLDHVFLRFamide) across members of seven decapod crustaean infraorders
    • Stemmler, E.A., Cashman, C.R., Messinger, D.I., Gardner, N.P., Dickinson, P.S., Christie, A.E.: High-mass-resolution direct-tissue MALDI-FTMS reveals broad conservation of three neuropeptides (APSGFLGMRamide, GYRKPPFNGSIFamide and pQDLDHVFLRFamide) across members of seven decapod crustaean infraorders. Peptides 28(11), 2104-2115 (2007)
    • (2007) Peptides , vol.28 , Issue.11 , pp. 2104-2115
    • Stemmler, E.A.1    Cashman, C.R.2    Messinger, D.I.3    Gardner, N.P.4    Dickinson, P.S.5    Christie, A.E.6
  • 49
    • 63849303089 scopus 로고    scopus 로고
    • Identification of SYWKQCAFNAVSCFamide: A broadly conserved crustacean C-type allatostatin-like peptide with both neuromodulatory and cardioactive properties
    • Dickinson, P.S., Wiwatpanit, T., Gabranski, E.R., Ackerman, R.J., Stevens, J.S., Cashman, C.R., Stemmler, E.A., Christie, A.E.: Identification of SYWKQCAFNAVSCFamide: a broadly conserved crustacean C-type allatostatin-like peptide with both neuromodulatory and cardioactive properties. J. Exp. Biol. 212(8), 1140-1152 (2009)
    • (2009) J. Exp. Biol. , vol.212 , Issue.8 , pp. 1140-1152
    • Dickinson, P.S.1    Wiwatpanit, T.2    Gabranski, E.R.3    Ackerman, R.J.4    Stevens, J.S.5    Cashman, C.R.6    Stemmler, E.A.7    Christie, A.E.8
  • 51
    • 3242661762 scopus 로고    scopus 로고
    • A modular data and control system to improve sensitivity, selectivity, speed of analysis, ease of use, and transient duration in an external source FTICR-MS
    • Mize, T.H., Taban, I., Duursma, M., Seynen, M., Konijnenburg, M., Vijftigschild, A., Doornik, C.V., Rooij, G.V., Heeren, R.M.A.: A modular data and control system to improve sensitivity, selectivity, speed of analysis, ease of use, and transient duration in an external source FTICR-MS. Int. J. Mass Spectrom. 235(3), 243-253 (2004)
    • (2004) Int. J. Mass Spectrom. , vol.235 , Issue.3 , pp. 243-253
    • Mize, T.H.1    Taban, I.2    Duursma, M.3    Seynen, M.4    Konijnenburg, M.5    Vijftigschild, A.6    Doornik, C.V.7    Rooij, G.V.8    Heeren, R.M.A.9
  • 53
    • 0347513521 scopus 로고    scopus 로고
    • Design and performance of a new FT-ICR cell operating at a temperature range of 77-438 K
    • Guo, X.H., Duursma, M., Al-Khalili, A., McDonnell, L.A., Heeren, R. M.A.: Design and performance of a new FT-ICR cell operating at a temperature range of 77-438 K. Int. J. Mass Spectrom. 231(1), 37-45 (2004)
    • (2004) Int. J. Mass Spectrom. , vol.231 , Issue.1 , pp. 37-45
    • Guo, X.H.1    Duursma, M.2    Al-Khalili, A.3    McDonnell, L.A.4    Heeren, R.M.A.5
  • 54
    • 33745152348 scopus 로고    scopus 로고
    • Combined infrared multiphoton dissociation and electron-capture dissociation using co-linear and overlapping beams in Fourier transform ion cyclotron resonance mass spectrometry
    • Mihalca, R., van der Burgt, Y.E.M., McDonnell, L.A., Duursma, M., Cerjak, I., Heck, A.J.R., Heeren, R.M.A.: Combined infrared multiphoton dissociation and electron-capture dissociation using co-linear and overlapping beams in Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun. Mass Spectrom. 20(12), 1838-1844 (2006)
    • (2006) Rapid Commun. Mass Spectrom. , vol.20 , Issue.12 , pp. 1838-1844
    • Mihalca, R.1    Van Der Burgt, Y.E.M.2    McDonnell, L.A.3    Duursma, M.4    Cerjak, I.5    Heck, A.J.R.6    Heeren, R.M.A.7
  • 55
    • 29144515669 scopus 로고    scopus 로고
    • Examples of Fourier transform ion cyclotron resonance mass spectrometry developments: From ion physics to remote access biochemical mass spectrometry
    • Rompp, A., Taban, I.M., Mihalca, R., Duursma, M.C., Mize, T.H., McDonnell, L.A., Heeren, R.M.A.: Examples of Fourier transform ion cyclotron resonance mass spectrometry developments: from ion physics to remote access biochemical mass spectrometry. Eur. J. Mass Spectrom. 11(5), 443-456 (2005)
    • (2005) Eur. J. Mass Spectrom. , vol.11 , Issue.5 , pp. 443-456
    • Rompp, A.1    Taban, I.M.2    Mihalca, R.3    Duursma, M.C.4    Mize, T.H.5    McDonnell, L.A.6    Heeren, R.M.A.7
  • 57
    • 0030670216 scopus 로고    scopus 로고
    • A novel ion funnel for focusing ions at elevated pressure using electrospray ionization mass spectrometry
    • Shaffer, S.A., Tang, K.Q., Anderson, G.A., Prior, D.C., Udseth, H.R., Smith, R.D.: A novel ion funnel for focusing ions at elevated pressure using electrospray ionization mass spectrometry. Rapid Commun. Mass Spectrom. 11(16), 1813-1817 (1997)
    • (1997) Rapid Commun. Mass Spectrom. , vol.11 , Issue.16 , pp. 1813-1817
    • Shaffer, S.A.1    Tang, K.Q.2    Anderson, G.A.3    Prior, D.C.4    Udseth, H.R.5    Smith, R.D.6
  • 58
    • 0032801521 scopus 로고    scopus 로고
    • Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry
    • Shaffer, S.A., Tolmachev, A., Prior, D.C., Anderson, G.A., Udseth, H. R., Smith, R.D.: Characterization of an improved electrodynamic ion funnel interface for electrospray ionization mass spectrometry. Anal. Chem. 71(15), 2957-2964 (1999)
    • (1999) Anal. Chem. , vol.71 , Issue.15 , pp. 2957-2964
    • Shaffer, S.A.1    Tolmachev, A.2    Prior, D.C.3    Anderson, G.A.4    Udseth, H.R.5    Smith, R.D.6
  • 59
    • 33747887548 scopus 로고    scopus 로고
    • Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface
    • Ibrahim, Y., Tang, K.Q., Tolmachev, A.V., Shvartsburg, A.A., Smith, R.D.: Improving mass spectrometer sensitivity using a high-pressure electrodynamic ion funnel interface. J. Am. Soc. Mass Spectrom. 17(9), 1299-1305 (2006)
    • (2006) J. Am. Soc. Mass Spectrom. , vol.17 , Issue.9 , pp. 1299-1305
    • Ibrahim, Y.1    Tang, K.Q.2    Tolmachev, A.V.3    Shvartsburg, A.A.4    Smith, R.D.5
  • 61
    • 0034671977 scopus 로고    scopus 로고
    • Broad-band ion accumulation with an internal source MALDI-FTICR-MS
    • Mize, T.H., Amster, I.J.: Broad-band ion accumulation with an internal source MALDI-FTICR-MS. Anal. Chem. 72(24), 5886-5891 (2000)
    • (2000) Anal. Chem. , vol.72 , Issue.24 , pp. 5886-5891
    • Mize, T.H.1    Amster, I.J.2
  • 62
    • 0034671965 scopus 로고    scopus 로고
    • Internal calibration on adjacent samples (INCAS) with Fourier transform mass spectrometry
    • O'Connor, P.B., Costello, C.E.: Internal calibration on adjacent samples (INCAS) with Fourier transform mass spectrometry. Anal. Chem. 72(24), 5881-5885 (2000)
    • (2000) Anal. Chem. , vol.72 , Issue.24 , pp. 5881-5885
    • O'Connor, P.B.1    Costello, C.E.2
  • 63
    • 22844449536 scopus 로고    scopus 로고
    • Simion analysis of a high performance linear accumulation octopole with enhanced ejection capabilities
    • Taban, I.M., McDonnell, L.A., Rompp, A., Cerjak, I., Heeren, R.M.A.: Simion analysis of a high performance linear accumulation octopole with enhanced ejection capabilities. Int. J. Mass Spectrom. 244(2-3), 135-143 (2005)
    • (2005) Int. J. Mass Spectrom. , vol.244 , Issue.2-3 , pp. 135-143
    • Taban, I.M.1    McDonnell, L.A.2    Rompp, A.3    Cerjak, I.4    Heeren, R.M.A.5
  • 64
    • 0038824578 scopus 로고    scopus 로고
    • Improved ion extraction from a linear octopole ion trap: Simion analysis and experimental demonstration
    • Wilcox, B.E., Hendrickson, C.L., Marshall, A.G.: Improved ion extraction from a linear octopole ion trap: simion analysis and experimental demonstration. J. Am. Soc. Mass Spectrom. 13(11), 1304-1312 (2002)
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , Issue.11 , pp. 1304-1312
    • Wilcox, B.E.1    Hendrickson, C.L.2    Marshall, A.G.3
  • 65
    • 84989132905 scopus 로고
    • The infinity cell - A new trapped-ion cell with radiofrequency covered trapping electrodes for Fourier-transform ion-cyclotron resonance mass-spectrometry
    • Caravatti, P., Allemann, M.: The infinity cell - a new trapped-ion cell with radiofrequency covered trapping electrodes for Fourier-transform ion-cyclotron resonance mass-spectrometry. Org. Mass Spectrom. 26(5), 514-518 (1991)
    • (1991) Org. Mass Spectrom. , vol.26 , Issue.5 , pp. 514-518
    • Caravatti, P.1    Allemann, M.2
  • 67
    • 49549153202 scopus 로고
    • Frequency-sweep Fourier transform ion cyclotron resonance spectroscopy
    • Comisarow, M.B., Marshall, A.G.: Frequency-sweep Fourier transform ion cyclotron resonance spectroscopy. Chem. Phys. Lett. 26(4), 489-490 (1974)
    • (1974) Chem. Phys. Lett. , vol.26 , Issue.4 , pp. 489-490
    • Comisarow, M.B.1    Marshall, A.G.2
  • 68
    • 48849086589 scopus 로고    scopus 로고
    • MITICS (MALSI Imaging Team Imaging Computing System): A new open source mass spectrometry imaging software
    • Jardin-Mathe, O., Bonnel, D., Franck, J., Wisztorski, M., Macagno, E., Fournier, I., Salzet, M.: MITICS (MALSI Imaging Team Imaging Computing System): a new open source mass spectrometry imaging software. J. Proteomics 71(3), 332-345 (2008)
    • (2008) J. Proteomics , vol.71 , Issue.3 , pp. 332-345
    • Jardin-Mathe, O.1    Bonnel, D.2    Franck, J.3    Wisztorski, M.4    Macagno, E.5    Fournier, I.6    Salzet, M.7
  • 69
    • 4243270417 scopus 로고    scopus 로고
    • Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: Theory and applications
    • Guan, S.H., Marshall, A.G.: Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: theory and applications. Int. J. Mass Spectrom. 157, 5-37 (1996)
    • (1996) Int. J. Mass Spectrom. , vol.157 , pp. 5-37
    • Guan, S.H.1    Marshall, A.G.2
  • 70
    • 0025780005 scopus 로고
    • Sustained off-resonance irradiation for collisionactivated dissociation involving Fourier-transform mass-spectrometry - Collision-activated disoociation technique that emultes infrared multiphoton dissociation
    • Gauthier, J.W., Trautman, T.R., Jacobson, D.B.: Sustained off-resonance irradiation for collisionactivated dissociation involving Fourier-transform mass-spectrometry - collision-activated disoociation technique that emultes infrared multiphoton dissociation. Anal. Chim. Acta 246(1), 211-225 (1991)
    • (1991) Anal. Chim. Acta , vol.246 , Issue.1 , pp. 211-225
    • Gauthier, J.W.1    Trautman, T.R.2    Jacobson, D.B.3
  • 71
    • 84990712066 scopus 로고
    • Mass-specific selection of ions in Fourier-transform ion-cyclotron resonance mass-spectrometry - Unintentional off-resonance cyclotron excitation of selected ions
    • Heck, A.J.R., Dekoning, L.J., Pinkse, F.A., Nibbering, N.M.M.: Mass-specific selection of ions in Fourier-transform ion-cyclotron resonance mass-spectrometry - unintentional off-resonance cyclotron excitation of selected ions. Rapid Commun. Mass Spectrom. 5(9), 406-414 (1991)
    • (1991) Rapid Commun. Mass Spectrom. , vol.5 , Issue.9 , pp. 406-414
    • Heck, A.J.R.1    Dekoning, L.J.2    Pinkse, F.A.3    Nibbering, N.M.M.4
  • 74
    • 0021705942 scopus 로고
    • Space charge effects in Fourier transform mass spectrometry mass calibration
    • Ledford Jr., E.B., Rempel, D.L., Gross, M.L.: Space charge effects in Fourier transform mass spectrometry mass calibration. Anal. Chem. 56, 2744-2748 (1984)
    • (1984) Anal. Chem. , vol.56 , pp. 2744-2748
    • Ledford Jr., E.B.1    Rempel, D.L.2    Gross, M.L.3
  • 75
    • 0033083537 scopus 로고    scopus 로고
    • Routine part-per-million mass accuracy for high- mass ions: Space-charge effects in MALDI FTICR
    • Easterling, M.L., Mize, T.H., Amster, I.J.: Routine part-per-million mass accuracy for high- mass ions: space-charge effects in MALDI FTICR. Anal. Chem. 71(3), 624-632 (1998)
    • (1998) Anal. Chem. , vol.71 , Issue.3 , pp. 624-632
    • Easterling, M.L.1    Mize, T.H.2    Amster, I.J.3
  • 76
    • 0033406099 scopus 로고    scopus 로고
    • Exact mass measurements using a 7 Tesla Fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environment
    • Burton, R.D., Matuszak, K.P., Watson, C.H., Eyler, J.R.: Exact mass measurements using a 7 Tesla Fourier transform ion cyclotron resonance mass spectrometer in a good laboratory practices-regulated environment. J. Am. Soc. Mass Spectrom. 10(12), 1291-1297 (1999)
    • (1999) J. Am. Soc. Mass Spectrom. , vol.10 , Issue.12 , pp. 1291-1297
    • Burton, R.D.1    Matuszak, K.P.2    Watson, C.H.3    Eyler, J.R.4
  • 78
    • 0041975811 scopus 로고    scopus 로고
    • Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-Fourier transform ion cyclotron resonance
    • Belov, M.E., Zhang, R., Strittmatter, E.F., Prior, D.C., Tang, K., Smith, R.D.: Automated gain control and internal calibration with external ion accumulation capillary liquid chromatography-electrospray ionization-Fourier transform ion cyclotron resonance. Anal. Chem. 75(16), 4195-4205 (2003)
    • (2003) Anal. Chem. , vol.75 , Issue.16 , pp. 4195-4205
    • Belov, M.E.1    Zhang, R.2    Strittmatter, E.F.3    Prior, D.C.4    Tang, K.5    Smith, R.D.6
  • 79
    • 0037236997 scopus 로고    scopus 로고
    • Initial implementation, of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control
    • Belov, M.E., Rakov, V.S., Nikolaev, E.N., Goshe, M.B., Anderson, G. A., Smith, R.D.: Initial implementation, of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control. Rapid Commun. Mass Spectrom. 17(7), 627-636 (2003)
    • (2003) Rapid Commun. Mass Spectrom. , vol.17 , Issue.7 , pp. 627-636
    • Belov, M.E.1    Rakov, V.S.2    Nikolaev, E.N.3    Goshe, M.B.4    Anderson, G.A.5    Smith, R.D.6
  • 81
  • 82
    • 27544499300 scopus 로고    scopus 로고
    • Direct profiling of lipid distribution in brain tissue using MALDI-TOFMS
    • Jackson, S.N., Wang, H.Y.J., Woods, A.S.: Direct profiling of lipid distribution in brain tissue using MALDI-TOFMS. Anal. Chem. 77(14), 4523-4527 (2005)
    • (2005) Anal. Chem. , vol.77 , Issue.14 , pp. 4523-4527
    • Jackson, S.N.1    Wang, H.Y.J.2    Woods, A.S.3
  • 83
    • 13444278814 scopus 로고    scopus 로고
    • Direct tissue analysis of phospholipids in rat brain using MALDI-TOFMS and MALDI-ion mobility-TOFMS
    • Jackson, S.N., Wang, H.-Y.J., Woods, A.S., Ugarov, M., Egan, T., Schultz, J.A.: Direct tissue analysis of phospholipids in rat brain using MALDI-TOFMS and MALDI-ion mobility-TOFMS. J. Am. Soc. Mass Spectrom. 16(2), 133-138 (2005)
    • (2005) J. Am. Soc. Mass Spectrom. , vol.16 , Issue.2 , pp. 133-138
    • Jackson, S.N.1    Wang, H.-Y.J.2    Woods, A.S.3    Ugarov, M.4    Egan, T.5    Schultz, J.A.6
  • 84
    • 27844595844 scopus 로고    scopus 로고
    • In situ structural characterization of phosphatidylcholines in brain tissue using MALDI-MS/MS
    • Jackson, S.N., Wang, H.-Y.J., Woods, A.S.: In situ structural characterization of phosphatidylcholines in brain tissue using MALDI-MS/MS. J. Am. Soc. Mass Spectrom. 16(12), 2052-2056 (2005)
    • (2005) J. Am. Soc. Mass Spectrom. , vol.16 , Issue.12 , pp. 2052-2056
    • Jackson, S.N.1    Wang, H.-Y.J.2    Woods, A.S.3
  • 85
    • 35748946316 scopus 로고    scopus 로고
    • Evaluation of sphingolipids changes in brain tissues of rats with pentylenetetrazol-induced kindled seizures using MALDI-TOF-MS
    • Ma, X., Liu, G., Wang, S., Chen, Z., Lai, M., Liu, Z., Yang, J.: Evaluation of sphingolipids changes in brain tissues of rats with pentylenetetrazol-induced kindled seizures using MALDI-TOF-MS. J. Chromatogr. B 859(2), 170-177 (2007)
    • (2007) J. Chromatogr. B , vol.859 , Issue.2 , pp. 170-177
    • Ma, X.1    Liu, G.2    Wang, S.3    Chen, Z.4    Lai, M.5    Liu, Z.6    Yang, J.7
  • 86
    • 57449121806 scopus 로고    scopus 로고
    • Profiling and imaging of lipids on brain and liver tissue by matrix-assisted laser desorption/ionization mass spectrometry using 2-mercaptobenzothiazole as a matrix
    • Astigarraga, E., Barreda-Gomez, G., Lombardero, L., Fresnedo, O., Castano, F., Giralt, M.T., Ochoa, B., Rodriguez-Puertas, R., Fernandez, J.A.: Profiling and imaging of lipids on brain and liver tissue by matrix-assisted laser desorption/ionization mass spectrometry using 2-mercaptobenzothiazole as a matrix. Anal. Chem. 80(23), 9105-9114 (2008)
    • (2008) Anal. Chem. , vol.80 , Issue.23 , pp. 9105-9114
    • Astigarraga, E.1    Barreda-Gomez, G.2    Lombardero, L.3    Fresnedo, O.4    Castano, F.5    Giralt, M.T.6    Ochoa, B.7    Rodriguez-Puertas, R.8    Fernandez, J.A.9
  • 88
    • 0030468505 scopus 로고    scopus 로고
    • Advantages of high magnetic field for Fourier transform ion cyclotron resonance mass spectrometry
    • Marshall, A.G., Guan, S.H.: Advantages of high magnetic field for Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun. Mass Spectrom. 10(14), 1819-1823 (1996)
    • (1996) Rapid Commun. Mass Spectrom. , vol.10 , Issue.14 , pp. 1819-1823
    • Marshall, A.G.1    Guan, S.H.2
  • 89
    • 67650711335 scopus 로고    scopus 로고
    • Performance evaluation of a high-field orbitrapmass analyzer
    • Makarov, A., Denisov, E., Lange, O.: Performance evaluation of a high-field orbitrapmass analyzer. J. Am. Soc. Mass Spectrom. 20(8), 1391-1396 (2009)
    • (2009) J. Am. Soc. Mass Spectrom. , vol.20 , Issue.8 , pp. 1391-1396
    • Makarov, A.1    Denisov, E.2    Lange, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.