메뉴 건너뛰기




Volumn 3, Issue 1, 2011, Pages 93-105

Steady-state MRI: Methods for neuroimaging

Author keywords

angiography; brain; diffusion; flow; fMRI; MRI; neuroimaging; SSFP; steady state; susceptibility

Indexed keywords

ANGIOGRAPHY; DIFFUSION WEIGHTED IMAGING; FUNCTIONAL MAGNETIC RESONANCE IMAGING; MAGNETISM; NEUROIMAGING; PRIORITY JOURNAL; RADIOFREQUENCY; REVIEW; RHEOENCEPHALOGRAPHY; SIGNAL NOISE RATIO; SIGNAL PROCESSING; STEADY STATE; THREE DIMENSIONAL IMAGING;

EID: 79952169316     PISSN: 17555191     EISSN: 17555205     Source Type: Journal    
DOI: 10.2217/iim.10.66     Document Type: Review
Times cited : (15)

References (110)
  • 3
    • 0000629553 scopus 로고
    • Phase and intensity anomalies in fourier transform NMR
    • Freeman R, Hill HDW: Phase and intensity anomalies in fourier transform NMR. J. Magn. Reson. 4, 366-383 (1971).
    • (1971) J. Magn. Reson. , vol.4 , pp. 366-383
    • Freeman, R.1    Hill, H.D.W.2
  • 4
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer LJ: Spoiling of transverse magnetization in steady-state sequences. Magn. Reson. Med. 21, 251-263 (1991).
    • (1991) Magn. Reson. Med. , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 6
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
    • Zur Y, Stokar S, Bendel P: An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn. Reson. Med. 6(2), 175-193 (1988).
    • (1988) Magn. Reson. Med. , vol.6 , Issue.2 , pp. 175-193
    • Zur, Y.1    Stokar, S.2    Bendel, P.3
  • 7
    • 0000369227 scopus 로고
    • Steady-state free precession in nuclear magnetic resonance
    • First occurance of balanced steady-state free precession (SSFP) in the NMR literature, more than 50 years ago. Carr presents an impressively comprehensive description of the primary effects studied subsequently in MRI
    • Carr HY: Steady-state free precession in nuclear magnetic resonance. Phys. Rev. Lett. 112, 1693-1701 (1958). First occurance of balanced steady-state free precession (SSFP) in the NMR literature, more than 50 years ago. Carr presents an impressively comprehensive description of the primary effects studied subsequently in MRI.
    • (1958) Phys. Rev. Lett. , vol.112 , pp. 1693-1701
    • Carr, H.Y.1
  • 9
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S: Principles and applications of balanced SSFP techniques. Euro. Radiol. 13(11), 2409-2418 (2003).
    • (2003) Euro. Radiol. , vol.13 , Issue.11 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 10
    • 0023705696 scopus 로고
    • The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences
    • Gyngell M: The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequences. Magn. Reson. Imaging 6, 415-419 (1988).
    • (1988) Magn. Reson. Imaging , vol.6 , pp. 415-419
    • Gyngell, M.1
  • 11
    • 84985848260 scopus 로고
    • Echoes: How to generate, recognize, use or avoid them in MR-imaging sequences
    • Describes the mechanisms of echo formation over multiple repetition time (TR) periods. Provides an excellent primer on the topic of coherence pathways, which are crucial to understanding this signal formation
    • Hennig J: Echoes: How to generate, recognize, use or avoid them in MR-imaging sequences. Concepts Magn. Reson. 3, 125-143 (1991). Describes the mechanisms of echo formation over multiple repetition time (TR) periods. Provides an excellent primer on the topic of coherence pathways, which are crucial to understanding this signal formation.
    • (1991) Concepts Magn. Reson. , vol.3 , pp. 125-143
    • Hennig, J.1
  • 14
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG: Characterization and reduction of the transient response in steady-state MR imaging. Magn. Reson. Med. 46(1), 149-158 (2001).
    • (2001) Magn. Reson. Med. , vol.46 , Issue.1 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 15
    • 26844509096 scopus 로고    scopus 로고
    • Flow compensation in balanced SSFP sequences
    • Highlights the subtleties in achieving true flow insensitivity with balanced SSFP in order to avoid image artifacts
    • Bieri O, Scheffler K: Flow compensation in balanced SSFP sequences. Magn. Reson. Med. 54(4), 901-907 (2005). Highlights the subtleties in achieving true flow insensitivity with balanced SSFP in order to avoid image artifacts.
    • (2005) Magn. Reson. Med. , vol.54 , Issue.4 , pp. 901-907
    • Bieri, O.1    Scheffler, K.2
  • 16
    • 0347003637 scopus 로고    scopus 로고
    • Flow artifacts in steady-state free precession cine imaging
    • Storey P, Li W, Chen Q, Edelman RR: Flow artifacts in steady-state free precession cine imaging. Magn. Reson. Med. 51, 115-122 (2004).
    • (2004) Magn. Reson. Med. , vol.51 , pp. 115-122
    • Storey, P.1    Li, W.2    Chen, Q.3    Edelman, R.R.4
  • 17
    • 0002521965 scopus 로고
    • Application of Fourier transform spectroscopy to magnetic resonance
    • Ernst R, Anderson W: Application of Fourier transform spectroscopy to magnetic resonance. Rev. Sci. Instruments 37, 93-102 (1966).
    • (1966) Rev. Sci. Instruments , vol.37 , pp. 93-102
    • Ernst, R.1    Anderson, W.2
  • 20
    • 0029760554 scopus 로고    scopus 로고
    • Magnetization transfer magnetic resonance imaging: A clinical review
    • Mehta RC, Pike GB, Enzmann DR: Magnetization transfer magnetic resonance imaging: a clinical review. Topics Magn. Res. Imaging 8, 214-230 (1996).
    • (1996) Topics Magn. Res. Imaging , vol.8 , pp. 214-230
    • Mehta, R.C.1    Pike, G.B.2    Enzmann, D.R.3
  • 21
    • 33847803187 scopus 로고
    • Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species
    • Christensen K, Grant D, Schulman E, Walling C: Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species. J. Phys. Chem. 78, 1971-1977 (1974).
    • (1974) J. Phys. Chem. , vol.78 , pp. 1971-1977
    • Christensen, K.1    Grant, D.2    Schulman, E.3    Walling, C.4
  • 24
    • 0013367398 scopus 로고
    • 1 relaxation. A re-evaluation of a rapid "new" method for determining NMR spin-lattice relaxation times
    • 1 relaxation. A re-evaluation of a rapid "new" method for determining NMR spin-lattice relaxation times. J. Magn. Reson. 63, 287-297 (1985).
    • (1985) J. Magn. Reson. , vol.63 , pp. 287-297
    • Homer, J.1    Beevers, M.2
  • 25
    • 33749056186 scopus 로고    scopus 로고
    • 1 measurements incorporating flip angle calibration and correction in vivo
    • 1 measurements incorporating flip angle calibration and correction in vivo. J. Magn. Reson. 182, 283-292 (2006).
    • (2006) J. Magn. Reson. , vol.182 , pp. 283-292
    • Wang, J.1    Qiu, M.2    Kim, H.3    Constable, R.4
  • 26
    • 33644813235 scopus 로고    scopus 로고
    • 1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity
    • 1 mapping by variable flip angles: accurate and precise measurements in the presence of radiofrequency field inhomogeneity. Magn. Reson. Med. 55, 566-574 (2006).
    • (2006) Magn. Reson. Med. , vol.55 , pp. 566-574
    • Cheng, H.M.1    Wright, G.2
  • 27
    • 33846078031 scopus 로고    scopus 로고
    • Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field
    • Yarnykh VL: Actual flip-angle imaging in the pulsed steady state: A method for rapid three-dimensional mapping of the transmitted radiofrequency field. Magn. Reson. Med. 57(1), 192-200 (2006).
    • (2006) Magn. Reson. Med. , vol.57 , Issue.1 , pp. 192-200
    • Yarnykh, V.L.1
  • 28
    • 0001480742 scopus 로고
    • 1 values by SNAPSHOT-FLASH NMR imaging
    • 1 values by SNAPSHOT-FLASH NMR imaging. J. Magn. Reson. 96, 608-612 (1992).
    • (1992) J. Magn. Reson. , vol.96 , pp. 608-612
    • Deichmann, R.1    Haase, A.2
  • 29
    • 0035095928 scopus 로고    scopus 로고
    • 1 quantification with inversion recovery trueFISP
    • 1 quantification with inversion recovery trueFISP. Magn. Reson. Med. 45(4), 720-723 (2001).
    • (2001) Magn. Reson. Med. , vol.45 , Issue.4 , pp. 720-723
    • Scheffler, K.1    Hennig, J.2
  • 30
    • 0024573913 scopus 로고
    • Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
    • Wolff SD, Balaban RS: Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn. Reson. Med. 10, 135-144 (1989).
    • (1989) Magn. Reson. Med. , vol.10 , pp. 135-144
    • Wolff, S.D.1    Balaban, R.S.2
  • 31
    • 0029993273 scopus 로고    scopus 로고
    • Pulsed magnetization transfer contrast in gradient echo imaging: A two-pool analytic description of signal response
    • Describes the theoretical steady-state signal equation for the magnetization transfer spoiled-gradient echo sequence based on the two-pool, coupled Bloch equations
    • Pike GB: Pulsed magnetization transfer contrast in gradient echo imaging: a two-pool analytic description of signal response. Magn. Reson. Med. 35, 95-103 (1996). Describes the theoretical steady-state signal equation for the magnetization transfer spoiled-gradient echo sequence based on the two-pool, coupled Bloch equations.
    • (1996) Magn. Reson. Med. , vol.35 , pp. 95-103
    • Pike, G.B.1
  • 32
    • 0034759242 scopus 로고    scopus 로고
    • Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI
    • Sled JG, Pike GB: Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI. Magn. Reson. Med. 46, 923-931 (2001).
    • (2001) Magn. Reson. Med. , vol.46 , pp. 923-931
    • Sled, J.G.1    Pike, G.B.2
  • 33
    • 0036999133 scopus 로고    scopus 로고
    • Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times
    • Ramani A, Dalton C, Miller DH, Tofts PS, Barker GJ: Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times. Magn. Reson. Imaging 20, 721-731 (2002).
    • (2002) Magn. Reson. Imaging , vol.20 , pp. 721-731
    • Ramani, A.1    Dalton, C.2    Miller, D.H.3    Tofts, P.S.4    Barker, G.J.5
  • 34
    • 0036234136 scopus 로고    scopus 로고
    • Pulsed Z-spectroscopic imaging of cross-relaxation parameters in tissues for human MRI: Theory and clinical applications
    • Yarnykh VL: Pulsed Z-spectroscopic imaging of cross-relaxation parameters in tissues for human MRI: theory and clinical applications. Magn. Reson. Med. 47, 929-939 (2002).
    • (2002) Magn. Reson. Med. , vol.47 , pp. 929-939
    • Yarnykh, V.L.1
  • 36
    • 55749114894 scopus 로고    scopus 로고
    • Steady state free precession magnetization transfer imaging
    • Bieri O, Mamisch T, Trattnig S, Scheffler K: Steady state free precession magnetization transfer imaging. Magn. Reson. Med. 60(5), 1261-1266 (2008).
    • (2008) Magn. Reson. Med. , vol.60 , Issue.5 , pp. 1261-1266
    • Bieri, O.1    Mamisch, T.2    Trattnig, S.3    Scheffler, K.4
  • 37
    • 51449112832 scopus 로고    scopus 로고
    • Quantitative magnetization transfer imaging using balanced SSFP
    • Gloor M, Scheffler K, Bieri O: Quantitative magnetization transfer imaging using balanced SSFP. Magn. Reson. Med. 60(3), 691-700 (2008).
    • (2008) Magn. Reson. Med. , vol.60 , Issue.3 , pp. 691-700
    • Gloor, M.1    Scheffler, K.2    Bieri, O.3
  • 38
    • 77953944594 scopus 로고    scopus 로고
    • Nonbalanced SSFP-based quantitative magnetization transfer imaging
    • Gloor M, Scheffler K, Bieri O: Nonbalanced SSFP-based quantitative magnetization transfer imaging. Magn. Reson. Med. 64(1), 149-156 (2010).
    • (2010) Magn. Reson. Med. , vol.64 , Issue.1 , pp. 149-156
    • Gloor, M.1    Scheffler, K.2    Bieri, O.3
  • 39
    • 0037370514 scopus 로고    scopus 로고
    • 2 mapping using gradient recalled acquisition in the steady state
    • 2 mapping using gradient recalled acquisition in the steady state. Magn. Reson. Med. 49(3), 515-526 (2003).
    • (2003) Magn. Reson. Med. , vol.49 , Issue.3 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 42
    • 68049142599 scopus 로고    scopus 로고
    • 2) mapping in the brain with off-resonance correction using phase-cycled steady-state free precession imaging
    • 2) mapping in the brain with off-resonance correction using phase-cycled steady-state free precession imaging. J. Magn. Reson. Imaging 30(2), 411-417 (2009).
    • (2009) J. Magn. Reson. Imaging , vol.30 , Issue.2 , pp. 411-417
    • Deoni, S.C.L.1
  • 44
    • 33847344305 scopus 로고    scopus 로고
    • Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession
    • Bieri O, Scheffler K: Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession. NMR Biomed. 20, 1-10 (2007).
    • (2007) NMR Biomed. , vol.20 , pp. 1-10
    • Bieri, O.1    Scheffler, K.2
  • 45
    • 44449141910 scopus 로고    scopus 로고
    • Investigating exchange and multicomponent relaxation in fully-balanced steady-state free precession imaging
    • Deoni SCL, Rutt BK, Jones DK: Investigating exchange and multicomponent relaxation in fully-balanced steady-state free precession imaging. JMRI 27(6), 1421-1429 (2008).
    • (2008) JMRI , vol.27 , Issue.6 , pp. 1421-1429
    • Deoni, S.C.L.1    Rutt, B.K.2    Jones, D.K.3
  • 46
    • 77956395177 scopus 로고    scopus 로고
    • Limitations of rapid myelin water quantification using 3D bSSFP
    • Lenz C, Klarhöfer M, Scheffler K: Limitations of rapid myelin water quantification using 3D bSSFP. MAGMA 23(3), 139-151 (2010).
    • (2010) MAGMA , vol.23 , Issue.3 , pp. 139-151
    • Lenz, C.1    Klarhöfer, M.2    Scheffler, K.3
  • 47
    • 70449371825 scopus 로고    scopus 로고
    • SSFP signal with finite RF pulses
    • Bieri O, Scheffler K: SSFP signal with finite RF pulses. Magn. Reson. Med. 62, 1232-1241 (2009).
    • (2009) Magn. Reson. Med. , vol.62 , pp. 1232-1241
    • Bieri, O.1    Scheffler, K.2
  • 48
    • 0025336246 scopus 로고
    • Oxygenation-sensitive contrast in magnetic resonance images of rodent brain at high magnetic fields
    • Ogawa S, Lee T-M, Nayak AS, Glynn P: Oxygenation-sensitive contrast in magnetic resonance images of rodent brain at high magnetic fields. Magn. Reson. Med. 14, 68-78 (1990).
    • (1990) Magn. Reson. Med. , vol.14 , pp. 68-78
    • Ogawa, S.1    Lee, T.-M.2    Nayak, A.S.3    Glynn, P.4
  • 49
    • 0020073799 scopus 로고
    • Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field
    • Thulborn KR, Waterton JC, Matthews PM, Radda GK: Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field. Biochim. Biophys. Acta 714, 265-270 (1982).
    • (1982) Biochim. Biophys. Acta , vol.714 , pp. 265-270
    • Thulborn, K.R.1    Waterton, J.C.2    Matthews, P.M.3    Radda, G.K.4
  • 50
    • 0035218353 scopus 로고    scopus 로고
    • Detection of BOLD changes by means of a frequency-sensitive TrueFISP technique: Preliminary results
    • First paper to propose using balanced SSFP to detect frequency shifts in vivo, forming the basis of many of the functional MRI (fMRI) and susceptibility techniques presented in this article
    • Scheffler K, Seifritz E, Bilecen D et al.: Detection of BOLD changes by means of a frequency-sensitive TrueFISP technique: preliminary results. NMR Biomed. 14, 490-496 (2001). First paper to propose using balanced SSFP to detect frequency shifts in vivo, forming the basis of many of the functional MRI (fMRI) and susceptibility techniques presented in this article.
    • (2001) NMR Biomed. , vol.14 , pp. 490-496
    • Scheffler, K.1    Seifritz, E.2    Bilecen, D.3
  • 51
    • 0141506103 scopus 로고    scopus 로고
    • DeCharms RC, Pauly JM: Functional MRI using a blood oxygenation sensitive steady state
    • Miller KL, Hargreaves BA, Lee J, Ress D, deCharms RC, Pauly JM: Functional MRI using a blood oxygenation sensitive steady state. Magn. Reson. Med. 50, 675-683 (2003).
    • (2003) Magn. Reson. Med. , vol.50 , pp. 675-683
    • Miller, K.L.1    Hargreaves, B.A.2    Lee, J.3    Ress, D.4
  • 53
    • 34548539941 scopus 로고    scopus 로고
    • Signal and noise characteristics of SSFP FMRI: A comparison with GRE at multiple field strengths
    • Miller KL, Smith SM, Jezzard P, Wiggins GC, Wiggins CJ: Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths. NeuroImage 37, 1227-1236 (2007).
    • (2007) NeuroImage , vol.37 , pp. 1227-1236
    • Miller, K.L.1    Smith, S.M.2    Jezzard, P.3    Wiggins, G.C.4    Wiggins, C.J.5
  • 54
    • 42549139817 scopus 로고    scopus 로고
    • Full-brain coverage and high-resolution imaging capabilities of passband BSSFP FMRI at 3T
    • Lee JH, Dumoulin SO, Saritas EU et al.: Full-brain coverage and high-resolution imaging capabilities of passband BSSFP FMRI at 3T. Magn. Reson. Med. 59(5), 1099-110 (2008).
    • (2008) Magn. Reson. Med. , vol.59 , Issue.5 , pp. 1099-1110
    • Lee, J.H.1    Dumoulin, S.O.2    Saritas, E.U.3
  • 56
    • 33846111314 scopus 로고    scopus 로고
    • Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla
    • Zhong K, Leupold J, Hennig J, Speck O: Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla. Magn. Reson. Med. 57(1), 67-73 (2007).
    • (2007) Magn. Reson. Med. , vol.57 , Issue.1 , pp. 67-73
    • Zhong, K.1    Leupold, J.2    Hennig, J.3    Speck, O.4
  • 58
    • 51449121884 scopus 로고    scopus 로고
    • Modeling SSFP functional MRI contrast in the brain
    • Discusses the broad range of contrast mechanisms contributing to fMRI contrast in balanced SSFP (both transition and pass band), relevant to other sources of susceptibility contrast, as well
    • Miller KL, Jezzard P: Modeling SSFP functional MRI contrast in the brain. Magn. Reson. Med. 60, 661-673 (2008). Discusses the broad range of contrast mechanisms contributing to fMRI contrast in balanced SSFP (both transition and pass band), relevant to other sources of susceptibility contrast, as well.
    • (2008) Magn. Reson. Med. , vol.60 , pp. 661-673
    • Miller, K.L.1    Jezzard, P.2
  • 59
    • 33748371623 scopus 로고    scopus 로고
    • Static susceptibility effects in balanced SSFP sequences
    • Ganter C: Static susceptibility effects in balanced SSFP sequences. Magn. Reson. Med. 56, 687-691 (2006).
    • (2006) Magn. Reson. Med. , vol.56 , pp. 687-691
    • Ganter, C.1
  • 60
    • 37549057693 scopus 로고    scopus 로고
    • Imaging periodic currents using alternating balanced steady-state free precession
    • Buracas GT, Liu TT, Buxton RB, Frank LR, Wong EC: Imaging periodic currents using alternating balanced steady-state free precession. Magn. Reson. Med. 59(1), 140-148 (2007).
    • (2007) Magn. Reson. Med. , vol.59 , Issue.1 , pp. 140-148
    • Buracas, G.T.1    Liu, T.T.2    Buxton, R.B.3    Frank, L.R.4    Wong, E.C.5
  • 62
    • 79952159850 scopus 로고    scopus 로고
    • High resolution 3D functional images of the human olfactory bulb using passband SSFP at 3T
    • Parrish T, Chen Y, Li W, Howard J, Gottfried J: High resolution 3D functional images of the human olfactory bulb using passband SSFP at 3T. Proc. ISMRM 16, 3567 (2008).
    • (2008) Proc. ISMRM , vol.16 , pp. 3567
    • Parrish, T.1    Chen, Y.2    Li, W.3    Howard, J.4    Gottfried, J.5
  • 63
    • 79952167125 scopus 로고    scopus 로고
    • Pass-band balanced steady state free precession functional MRI of the mouse retina
    • Muir E, Park S, Duong T: Pass-band balanced steady state free precession functional MRI of the mouse retina. Proc. ISMRM 1208 (2010).
    • (2010) Proc. ISMRM , vol.1208
    • Muir, E.1    Park, S.2    Duong, T.3
  • 64
    • 33646441856 scopus 로고    scopus 로고
    • Respiratory-induced B0 field fluctuation compensation in balanced SSFP: Real-time approach for transition-band SSFP FMRI
    • Lee J, Santos JM, Conolly SM, Miller KL, Hargreaves BA, Pauly JM: Respiratory-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP FMRI. Magn. Reson. Med. 55, 1197-1201 (2006).
    • (2006) Magn. Reson. Med. , vol.55 , pp. 1197-1201
    • Lee, J.1    Santos, J.M.2    Conolly, S.M.3    Miller, K.L.4    Hargreaves, B.A.5    Pauly, J.M.6
  • 65
    • 33846839591 scopus 로고    scopus 로고
    • Frequency stabilization using infinite impulse response filterin for SSFP FMRI at 3T
    • Wu ML, Wu PH, Huang TY et al.: Frequency stabilization using infinite impulse response filterin for SSFP FMRI at 3T. Magn. Reson. Med. 57, 369-379 (2007).
    • (2007) Magn. Reson. Med. , vol.57 , pp. 369-379
    • Wu, M.L.1    Wu, P.H.2    Huang, T.Y.3
  • 71
    • 77649257562 scopus 로고    scopus 로고
    • Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
    • Fukunaga M, Lee J, Li T-Q et al.: Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast. Proc. Natl Acad. Sci. USA 107(8), 3834-3839 (2010).
    • (2010) Proc. Natl Acad. Sci. USA , vol.107 , Issue.8 , pp. 3834-3839
    • Fukunaga, M.1    Lee, J.2    Li, T.-Q.3
  • 72
    • 69449094339 scopus 로고    scopus 로고
    • Biophysical mechanisms of phase contrast in gradient echo MRI
    • He X, Yablonskiy DA: Biophysical mechanisms of phase contrast in gradient echo MRI. Proc. Natl Acad. Sci. 106, 13558-13563 (2009).
    • (2009) Proc. Natl Acad. Sci. , vol.106 , pp. 13558-13563
    • He, X.1    Yablonskiy, D.A.2
  • 73
    • 18144431323 scopus 로고    scopus 로고
    • Frequency-shift based detection of BMS contrast agents using SSFP: Potential for MRA
    • Dubois J, Lethimonnier F, Vaufrey F, Robert P, Bihan DL: Frequency-shift based detection of BMS contrast agents using SSFP: potential for MRA. Magn. Reson. Imaging 23, 453-462 (2005).
    • (2005) Magn. Reson. Imaging , vol.23 , pp. 453-462
    • Dubois, J.1    Lethimonnier, F.2    Vaufrey, F.3    Robert, P.4    Bihan, D.L.5
  • 74
    • 0037408441 scopus 로고    scopus 로고
    • Imaging single mammalian cells with a 1.5 T clinical MRI scanner
    • Foster-Garaeu P, Heyn C, Alejski A, Rutt B: Imaging single mammalian cells with a 1.5 T clinical MRI scanner. Magn. Reson. Med. 49(5), 968-971 (2003).
    • (2003) Magn. Reson. Med. , vol.49 , Issue.5 , pp. 968-971
    • Foster-Garaeu, P.1    Heyn, C.2    Alejski, A.3    Rutt, B.4
  • 75
    • 33747595007 scopus 로고    scopus 로고
    • Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: Theory and proof-of-principle experiments
    • Dharmakumar R, Koktzoglou I, Li D: Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: theory and proof-of-principle experiments. Phys. Med. Biol. 51(17), 4201-4215 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , Issue.17 , pp. 4201-4215
    • Dharmakumar, R.1    Koktzoglou, I.2    Li, D.3
  • 76
    • 75749139296 scopus 로고    scopus 로고
    • Positive contrast with alternating repetition time SSFP (PARTS): A fast imaging technique for SPIO-labeled cells
    • Cukur T, Yamada M, Overall W, Yang P, Nishimura D: Positive contrast with alternating repetition time SSFP (PARTS): a fast imaging technique for SPIO-labeled cells. Magn. Reson. Med. 63(2), 427-437 (2010).
    • (2010) Magn. Reson. Med. , vol.63 , Issue.2 , pp. 427-437
    • Cukur, T.1    Yamada, M.2    Overall, W.3    Yang, P.4    Nishimura, D.5
  • 78
    • 78650936663 scopus 로고    scopus 로고
    • Improving contrast-to-noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession
    • Lee J, Fukunaga M, Duyn JH: Improving contrast-to-noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession. NeuroImage 54, 2779-2788 (2011).
    • (2011) NeuroImage , vol.54 , pp. 2779-2788
    • Lee, J.1    Fukunaga, M.2    Duyn, J.H.3
  • 80
    • 75749087564 scopus 로고    scopus 로고
    • Asymmetries of the balanced SSFP profile. Part I: Theory and observation
    • Miller KL: Asymmetries of the balanced SSFP profile. Part I: theory and observation. Magn. Reson. Med. 63, 385-395 (2010).
    • (2010) Magn. Reson. Med. , vol.63 , pp. 385-395
    • Miller, K.L.1
  • 81
    • 75749133184 scopus 로고    scopus 로고
    • Asymmetries of the balanced SSFP profile. Part II: White matter
    • Miller KL, Smith SM, Jezzard P: Asymmetries of the balanced SSFP profile. Part II: white matter. Magn. Reson. Med. 63, 396-406 (2010).
    • (2010) Magn. Reson. Med. , vol.63 , pp. 396-406
    • Miller, K.L.1    Smith, S.M.2    Jezzard, P.3
  • 83
    • 84994888882 scopus 로고
    • Spin-diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • Stejskal EO, Tanner JE: Spin-diffusion measurements: spin echoes in the presence of a time-dependent field gradient. J. Chem. Phys. 19(4), 306-317 (1965).
    • (1965) J. Chem. Phys. , vol.19 , Issue.4 , pp. 306-317
    • Stejskal, E.O.1    Tanner, J.E.2
  • 85
    • 0023726714 scopus 로고
    • Intravoxel incoherent motion imaging using steady-state free precession
    • LeBihan D: Intravoxel incoherent motion imaging using steady-state free precession. Magn. Reson. Med. 7, 346-351 (1988).
    • (1988) Magn. Reson. Med. , vol.7 , pp. 346-351
    • LeBihan, D.1
  • 86
    • 0001374079 scopus 로고
    • Rapid NMR imaging of molecular self-diffusion using a modified CE-FAST sequence
    • Merboldt KD, Hanicke WH, Gyngell ML, Frahm J, Bruhn H: Rapid NMR imaging of molecular self-diffusion using a modified CE-FAST sequence. J. Magn. Reson. 82, 115-130 (1989).
    • (1989) J. Magn. Reson. , vol.82 , pp. 115-130
    • Merboldt, K.D.1    Hanicke, W.H.2    Gyngell, M.L.3    Frahm, J.4    Bruhn, H.5
  • 87
    • 0027465243 scopus 로고
    • The diffusion sensitivity of fast steady-state free precession imaging
    • Presents an intuitive description of the diffusion-weighted steady-state signal based on coherence pathway components
    • Buxton RB: The diffusion sensitivity of fast steady-state free precession imaging. Magn. Reson. Med. 29, 235-243 (1993). Presents an intuitive description of the diffusion-weighted steady-state signal based on coherence pathway components.
    • (1993) Magn. Reson. Med. , vol.29 , pp. 235-243
    • Buxton, R.B.1
  • 88
    • 0000331839 scopus 로고
    • Diffusion and field-gradient effects in NMR Fourier spectroscopy
    • Kaiser R, Barthold E, Ernst RR: Diffusion and field-gradient effects in NMR Fourier spectroscopy. J. Chem. Phys. 60(8), 2966-2979 (1974).
    • (1974) J. Chem. Phys. , vol.60 , Issue.8 , pp. 2966-2979
    • Kaiser, R.1    Barthold, E.2    Ernst, R.R.3
  • 89
    • 0024436514 scopus 로고
    • The influence of flow and motion in MRI of diffusion using a modified CE-FAST sequence
    • Merboldt KD, Hanicke W, Gyngell ML, Frahm J, Bruhn H: The influence of flow and motion in MRI of diffusion using a modified CE-FAST sequence. Magn. Reson. Med. 12, 198-208 (1989).
    • (1989) Magn. Reson. Med. , vol.12 , pp. 198-208
    • Merboldt, K.D.1    Hanicke, W.2    Gyngell, M.L.3    Frahm, J.4    Bruhn, H.5
  • 90
    • 0030897466 scopus 로고    scopus 로고
    • A new diffusion SSFP imaging technique
    • Zur Y, Bosak E, Kaplan N: A new diffusion SSFP imaging technique. Magn. Reson. Med. 37, 716-722 (1997).
    • (1997) Magn. Reson. Med. , vol.37 , pp. 716-722
    • Zur, Y.1    Bosak, E.2    Kaplan, N.3
  • 91
    • 0042092052 scopus 로고    scopus 로고
    • Nonlinear phase correction for navigated diffusion imaging
    • Miller KL, Pauly JM: Nonlinear phase correction for navigated diffusion imaging. Magn. Reson. Med. 50, 343-353 (2003).
    • (2003) Magn. Reson. Med. , vol.50 , pp. 343-353
    • Miller, K.L.1    Pauly, J.M.2
  • 92
    • 73349086834 scopus 로고    scopus 로고
    • 3D steady-state diffusion-weighted imaging with trajectory using radially-batched internal navigator echoes (TURBINE)
    • McNab JA, Gallichan D, Miller KL: 3D steady-state diffusion-weighted imaging with trajectory using radially-batched internal navigator echoes (TURBINE). Magn. Reson. Med. 63, 235-242 (2010).
    • (2010) Magn. Reson. Med. , vol.63 , pp. 235-242
    • McNab, J.A.1    Gallichan, D.2    Miller, K.L.3
  • 93
    • 66149100092 scopus 로고    scopus 로고
    • 3D diffusion tensor MRI with istoropic resolution using a steady-state radial acquisition
    • Jung Y, Samsonov AA, Block WF et al.: 3D diffusion tensor MRI with istoropic resolution using a steady-state radial acquisition. J. Magn. Reson. Imaging 29, 1175-1184 (2009).
    • (2009) J. Magn. Reson. Imaging , vol.29 , pp. 1175-1184
    • Jung, Y.1    Samsonov, A.A.2    Block, W.F.3
  • 95
    • 0035029342 scopus 로고    scopus 로고
    • Online motion correction for diffusion-weighted imaging using navigator echoes: Application to RARE imaging without sensitivity loss
    • Norris DG, Driesel W: Online motion correction for diffusion-weighted imaging using navigator echoes: application to RARE imaging without sensitivity loss. Magn. Reson. Med. 45, 729-733 (2001).
    • (2001) Magn. Reson. Med. , vol.45 , pp. 729-733
    • Norris, D.G.1    Driesel, W.2
  • 96
    • 0141506080 scopus 로고    scopus 로고
    • High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes
    • Jeong EK, Kim SE, Parker DL: High-resolution diffusion-weighted 3D MRI, using diffusion-weighted driven equilibrium (DW-DE) and multishot segmented 3D-SSFP without navigator echoes. Magn. Reson. Med. 50, 821-829 (2003).
    • (2003) Magn. Reson. Med. , vol.50 , pp. 821-829
    • Jeong, E.K.1    Kim, S.E.2    Parker, D.L.3
  • 97
    • 0030185327 scopus 로고    scopus 로고
    • High-speed diffusion imaging in the presence of eddy currents
    • Sinha U, Sinha S: High-speed diffusion imaging in the presence of eddy currents. J. Magn. Reson. Imaging 6, 657-666 (1996).
    • (1996) J. Magn. Reson. Imaging , vol.6 , pp. 657-666
    • Sinha, U.1    Sinha, S.2
  • 98
    • 78650468520 scopus 로고    scopus 로고
    • Steady-state diffusion-weighted imaging: Theory, acquisition and analysis
    • McNab JA, Miller KL: Steady-state diffusion-weighted imaging: theory, acquisition and analysis. NMR Biomed. 23(7), 781-793 (2010).
    • (2010) NMR Biomed. , vol.23 , Issue.7 , pp. 781-793
    • McNab, J.A.1    Miller, K.L.2
  • 99
    • 0026078369 scopus 로고
    • MR angiography by multiple thin slab 3D acquisition
    • Parker DL, Yuan C, Blatter DD: MR angiography by multiple thin slab 3D acquisition. Magn. Reson. Med. 17(2), 434-451 (1991).
    • (1991) Magn. Reson. Med. , vol.17 , Issue.2 , pp. 434-451
    • Parker, D.L.1    Yuan, C.2    Blatter, D.D.3
  • 100
    • 0035023617 scopus 로고    scopus 로고
    • Cine MR angiography of the heart with segmented true fast imaging with steady-state precession
    • Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP: Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219(3), 828-834 (2001).
    • (2001) Radiology , vol.219 , Issue.3 , pp. 828-834
    • Carr, J.C.1    Simonetti, O.2    Bundy, J.3    Li, D.4    Pereles, S.5    Finn, J.P.6
  • 102
    • 0028153930 scopus 로고
    • Signal targeting with alternating radiofrequency (STAR) sequences: Application to MR angiography
    • Edelman RR, Siewert B, Adamis M, Gaa J, Laub G, Wielopolski P: Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography. Magn. Reson. Med. 31(2), 233-238 (1994).
    • (1994) Magn. Reson. Med. , vol.31 , Issue.2 , pp. 233-238
    • Edelman, R.R.1    Siewert, B.2    Adamis, M.3    Gaa, J.4    Laub, G.5    Wielopolski, P.6
  • 103
    • 67650085276 scopus 로고    scopus 로고
    • Time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material in the brain: Initial investigation
    • Hori M, Shiraga N, Watanabe Y et al.: Time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material in the brain: initial investigation. J. Magn. Reson. Imaging 30(1), 214-218 (2009).
    • (2009) J. Magn. Reson. Imaging , vol.30 , Issue.1 , pp. 214-218
    • Hori, M.1    Shiraga, N.2    Watanabe, Y.3
  • 105
    • 77953950598 scopus 로고    scopus 로고
    • Unenhanced dynamic MR angiography: High spatial and temporal resolution by using true FISP-based spin tagging with alternating radiofrequency
    • A nice demonstration of cerebral angiography using a catalyzed balanced SSFP acquisition in conjunction with inversion preparation
    • Yan L, Wang S, Zhuo Y et al.: Unenhanced dynamic MR angiography: high spatial and temporal resolution by using true FISP-based spin tagging with alternating radiofrequency. Radiology 256(1), 270-279 (2010). A nice demonstration of cerebral angiography using a catalyzed balanced SSFP acquisition in conjunction with inversion preparation.
    • (2010) Radiology , vol.256 , Issue.1 , pp. 270-279
    • Yan, L.1    Wang, S.2    Zhuo, Y.3
  • 106
    • 0036845660 scopus 로고    scopus 로고
    • Fast phase-contrast velocity measurement in the steady state
    • Overall WR, Nishimura DG, Hu BS: Fast phase-contrast velocity measurement in the steady state. Magn. Reson. Med. 48(5), 890-898 (2002).
    • (2002) Magn. Reson. Med. , vol.48 , Issue.5 , pp. 890-898
    • Overall, W.R.1    Nishimura, D.G.2    Hu, B.S.3
  • 107
    • 0037407393 scopus 로고    scopus 로고
    • Balanced phase-contrast steady-state free precession (PC-SSFP): A novel technique for velocity encoding by gradient inversion
    • Markl M, Alley MT, Pelc NJ: Balanced phase-contrast steady-state free precession (PC-SSFP): a novel technique for velocity encoding by gradient inversion. Magn. Reson. Med. 49(5), 945-952 (2003).
    • (2003) Magn. Reson. Med. , vol.49 , Issue.5 , pp. 945-952
    • Markl, M.1    Alley, M.T.2    Pelc, N.J.3
  • 108
    • 70349632621 scopus 로고    scopus 로고
    • Time-resolved three-dimensional (3D) phase-contrast (PC) balanced steady-state free precession (bSSFP)
    • Santini F, Wetzel SG, Bock J, Markl M, Scheffler K: Time-resolved three-dimensional (3D) phase-contrast (PC) balanced steady-state free precession (bSSFP). Magn. Reson. Med. 62(4), 966-974 (2009).
    • (2009) Magn. Reson. Med. , vol.62 , Issue.4 , pp. 966-974
    • Santini, F.1    Wetzel, S.G.2    Bock, J.3    Markl, M.4    Scheffler, K.5
  • 109
    • 0242385495 scopus 로고    scopus 로고
    • Flow effects in balanced steady state free precession imaging
    • Markl M, Alley MT, Elkins CJ, Pelc NJ: Flow effects in balanced steady state free precession imaging. Magn. Reson. Med. 50(5), 892-903 (2003).
    • (2003) Magn. Reson. Med. , vol.50 , Issue.5 , pp. 892-903
    • Markl, M.1    Alley, M.T.2    Elkins, C.J.3    Pelc, N.J.4
  • 110
    • 34247868862 scopus 로고    scopus 로고
    • FAIR-TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla
    • Boss A, Martirosian P, Klose U, Nagele T, Claussen CD, Schick F: FAIR-TrueFISP imaging of cerebral perfusion in areas of high magnetic susceptibility differences at 1.5 and 3 Tesla. J. Magn. Reson. Imaging 25(5), 924-931 (2007).
    • (2007) J. Magn. Reson. Imaging , vol.25 , Issue.5 , pp. 924-931
    • Boss, A.1    Martirosian, P.2    Klose, U.3    Nagele, T.4    Claussen, C.D.5    Schick, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.