메뉴 건너뛰기




Volumn 30, Issue 2, 2009, Pages 411-417

Transverse relaxation time (T2) mapping in the brain with off-resonance correction using phase-cycled steady-state free precession imaging

Author keywords

High field imaging; High resolution imaging; Human brain imaging; Quantitative magnetic resonance imaging; Steady state free precession; T2

Indexed keywords

ACCURACY; ADULT; ARTICLE; ARTIFACT; BRAIN MAPPING; CONTROLLED STUDY; HUMAN; HUMAN EXPERIMENT; IN VIVO CULTURE; MEASUREMENT ERROR; NEUROIMAGING; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE; PRIORITY JOURNAL; RADIOFREQUENCY; SIGNAL PROCESSING; STEADY STATE;

EID: 68049142599     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21849     Document Type: Article
Times cited : (82)

References (21)
  • 1
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping with gradient recalled acquisition in the steady-state
    • Deoni SCL, Rutt BK, Peters TM. Rapid combined T1 and T2 mapping with gradient recalled acquisition in the steady-state. Magn Reson Med 2003;46:515-526.
    • (2003) Magn Reson Med , vol.46 , pp. 515-526
    • Deoni, S.C.L.1    Rutt, B.K.2    Peters, T.M.3
  • 2
    • 33847803187 scopus 로고
    • Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species
    • Christensen KA, Grand DM, Schulman EM, Walling C. Optimal determination of relaxation times of Fourier transform nuclear magnetic resonance. Determination of spin-lattice relaxation times in chemically polarized species. J Phys Chem 1974;78:1971-1977.
    • (1974) J Phys Chem , vol.78 , pp. 1971-1977
    • Christensen, K.A.1    Grand, D.M.2    Schulman, E.M.3    Walling, C.4
  • 3
    • 12144277049 scopus 로고    scopus 로고
    • High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2
    • Deoni SCL, Peters TM, Rutt BK. High-resolution T1 and T2 mapping of the brain in a clinically acceptable time with DESPOT1 and DESPOT2. Magn Reson Med 2005;53:237-241.
    • (2005) Magn Reson Med , vol.53 , pp. 237-241
    • Deoni, S.C.L.1    Peters, T.M.2    Rutt, B.K.3
  • 4
    • 0025675774 scopus 로고
    • Motion-insensitive, steady-state free precession imaging
    • Zur Y, Wood ML, Neuringer LJ. Motion-insensitive, steady-state free precession imaging. Magn Reson Med 1990;16:444-459.
    • (1990) Magn Reson Med , vol.16 , pp. 444-459
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 5
    • 0000629553 scopus 로고
    • Phase and intensity anomalies in Fourier transform NMR
    • Freeman R, Hill HDW. Phase and intensity anomalies in Fourier transform NMR. J Magn Reson 1971;4:366-383.
    • (1971) J Magn Reson , vol.4 , pp. 366-383
    • Freeman, R.1    Hill, H.D.W.2
  • 6
    • 3543134876 scopus 로고    scopus 로고
    • Rapid T2 estimation with phase-cycled variable nutation steady-state free precession
    • Deoni SCL, Ward HA, Peters TM, Rutt BK. Rapid T2 estimation with phase-cycled variable nutation steady-state free precession. Magn Reson Med 2004;52:435-439.
    • (2004) Magn Reson Med , vol.52 , pp. 435-439
    • Deoni, S.C.L.1    Ward, H.A.2    Peters, T.M.3    Rutt, B.K.4
  • 7
    • 0000369227 scopus 로고
    • Steady-state free precession in nuclear magnetic resonance
    • Carr HY. Steady-state free precession in nuclear magnetic resonance. Phys Rev 1965;112:1693-1701.
    • (1965) Phys Rev , vol.112 , pp. 1693-1701
    • Carr, H.Y.1
  • 8
    • 0016984868 scopus 로고
    • Image formation by nuclear magnetic resonance: The sensitive point method
    • Hinshaw WS. Image formation by nuclear magnetic resonance: the sensitive point method. J Appl Phys 1976;47:3709-3721.
    • (1976) J Appl Phys , vol.47 , pp. 3709-3721
    • Hinshaw, W.S.1
  • 9
    • 0037311485 scopus 로고    scopus 로고
    • Is TrueFISP a gradient-echo or spin-echo sequence?
    • Scheffler K, Hennig J. Is TrueFISP a gradient-echo or spin-echo sequence? Magn Reson Med 2003;49:395-397.
    • (2003) Magn Reson Med , vol.49 , pp. 395-397
    • Scheffler, K.1    Hennig, J.2
  • 11
    • 0026258703 scopus 로고
    • Microphone array optimization by stochastic region contraction
    • Berger MF, Silverman HF. Microphone array optimization by stochastic region contraction. IEEE Trans Signal Process 1991;39:2377-2386.
    • (1991) IEEE Trans Signal Process , vol.39 , pp. 2377-2386
    • Berger, M.F.1    Silverman, H.F.2
  • 12
    • 35148865818 scopus 로고    scopus 로고
    • High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI)
    • Deoni SCL. High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI). J Magn Reson Imaging 2007;26:1106-1111.
    • (2007) J Magn Reson Imaging , vol.26 , pp. 1106-1111
    • Deoni, S.C.L.1
  • 13
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3T
    • Stanisz GJ, Odrobina EE, Pun J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005;54:507-512.
    • (2005) Magn Reson Med , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 14
    • 0028987644 scopus 로고
    • Magnetization transfer and T2 relaxation components in tissue
    • Harrison R, Bronskill MJ, Henkelman RM. Magnetization transfer and T2 relaxation components in tissue. Magn Reson Med 1995;33:490-496.
    • (1995) Magn Reson Med , vol.33 , pp. 490-496
    • Harrison, R.1    Bronskill, M.J.2    Henkelman, R.M.3
  • 18
    • 0036179798 scopus 로고    scopus 로고
    • The effect of haemosiderosis and blood transfusions on the T2 relaxation time and 1/T2 relaxation rate of liver tissue
    • Salo S, Alanen A, Leino R, Bondestam S, Komu M. The effect of haemosiderosis and blood transfusions on the T2 relaxation time and 1/T2 relaxation rate of liver tissue. Br J Radiol 2002;75:24-27. (Pubitemid 34168317)
    • (2002) British Journal of Radiology , vol.75 , Issue.889 , pp. 24-27
    • Salo, S.1    Alanen, A.2    Leino, R.3    Bondestam, S.4    Komu, M.5
  • 19
    • 0036677965 scopus 로고    scopus 로고
    • Cerebral lobes in autism: Early hyperplasia and abnormal age effects
    • DOI 10.1006/nimg.2002.1099
    • Carper RA, Moses P, Tique ZD, Courchesne E. Cerebral lobes in autism: early hyperplasia and abnormal age effects. NeuroImage 2002;16:1038-1051. (Pubitemid 34899164)
    • (2002) NeuroImage , vol.16 , Issue.4 , pp. 1038-1051
    • Carper, R.A.1    Moses, P.2    Tigue, Z.D.3    Courchesne, E.4
  • 20
    • 16244408961 scopus 로고    scopus 로고
    • Reduced functional connectivity between V1 and inferior frontal cortex associated with visuomotor performance in autism
    • DOI 10.1016/j.neuroimage.2004.12.022
    • Villalobos ME, Mizuno A, Dahl BC, Kemmotsu N, Muller RA. Reduced functional connectivity between V1 and inferior frontal cortex associated with visuomotor performance in autism. NeuroImage 2005;15:919-925. (Pubitemid 40461729)
    • (2005) NeuroImage , vol.25 , Issue.3 , pp. 916-925
    • Villalobos, M.E.1    Mizuno, A.2    Dahl, B.C.3    Kemmotsu, N.4    Muller, R.-A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.