메뉴 건너뛰기




Volumn 57, Issue 2, 2007, Pages 369-379

Frequency stabilization using infinite impulse response filtering for SSFP fMRI at 3T

Author keywords

Balanced steady state free precession; Blood oxygenation sensitive steady state; Frequency stabilization; Functional magnetic resonance imaging; IIR filter

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; FREQUENCY STABILITY; IMPULSE RESPONSE; LOW PASS FILTERS; MAGNETIC RESONANCE IMAGING; MAGNETISM; OPTICAL FIBER COMMUNICATION; STABILIZATION;

EID: 33846839591     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21138     Document Type: Article
Times cited : (17)

References (29)
  • 2
    • 0032883422 scopus 로고    scopus 로고
    • Sources of distortion in functional MRI data
    • Jezzard P, Clare S. Sources of distortion in functional MRI data. Hum Brain Mapp 1999;8:80-85.
    • (1999) Hum Brain Mapp , vol.8 , pp. 80-85
    • Jezzard, P.1    Clare, S.2
  • 3
    • 0035101324 scopus 로고    scopus 로고
    • Optimized distortion correction technique for echo planar imaging
    • Chen NK, Wyrwicz AM. Optimized distortion correction technique for echo planar imaging. Magn Reson Med 2001;45:525-528.
    • (2001) Magn Reson Med , vol.45 , pp. 525-528
    • Chen, N.K.1    Wyrwicz, A.M.2
  • 4
    • 27644550523 scopus 로고    scopus 로고
    • Geometric distortion correction of high-resolution 3 T diffusion tensor brain images
    • Ardekani S, Sinha U. Geometric distortion correction of high-resolution 3 T diffusion tensor brain images. Magn Reson Med 2005;54:1163-1171.
    • (2005) Magn Reson Med , vol.54 , pp. 1163-1171
    • Ardekani, S.1    Sinha, U.2
  • 7
    • 0025232486 scopus 로고
    • Steady-state free precession imaging in the presence of motion: Application for improved visualization of the cerebrospinal fluid
    • Haacke EM, Wielopolski PA, Tkach JA, Modic MT. Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid. Radiology 1990;175:545-552.
    • (1990) Radiology , vol.175 , pp. 545-552
    • Haacke, E.M.1    Wielopolski, P.A.2    Tkach, J.A.3    Modic, M.T.4
  • 10
    • 0036160977 scopus 로고    scopus 로고
    • Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging
    • Pfeuffer J, Van de Moortele PF, Ugurbil K, Hu X, Glover GH. Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging. Magn Reson Med 2002;47:344-353.
    • (2002) Magn Reson Med , vol.47 , pp. 344-353
    • Pfeuffer, J.1    Van de Moortele, P.F.2    Ugurbil, K.3    Hu, X.4    Glover, G.H.5
  • 11
    • 33646441856 scopus 로고    scopus 로고
    • Respiration-induced B0 field fluctuation compensation in balanced SSFP: Real-time approach for transition-band SSFP fMRI
    • Lee J, Santos JM, Conolly SM, Miller KL, Hargreaves BA, Pauly JM. Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI. Magn Reson Med 2006;55:1197-1201.
    • (2006) Magn Reson Med , vol.55 , pp. 1197-1201
    • Lee, J.1    Santos, J.M.2    Conolly, S.M.3    Miller, K.L.4    Hargreaves, B.A.5    Pauly, J.M.6
  • 12
    • 12844268211 scopus 로고    scopus 로고
    • Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging
    • Ebel A, Maudsley AA. Detection and correction of frequency instabilities for volumetric 1H echo-planar spectroscopic imaging. Magn Reson Med 2005;53:465-469.
    • (2005) Magn Reson Med , vol.53 , pp. 465-469
    • Ebel, A.1    Maudsley, A.A.2
  • 13
    • 27644557313 scopus 로고    scopus 로고
    • Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging
    • Foerster BU, Tomasi D, Caparelli EC. Magnetic field shift due to mechanical vibration in functional magnetic resonance imaging. Magn Reson Med 2005;54:1261-1267.
    • (2005) Magn Reson Med , vol.54 , pp. 1261-1267
    • Foerster, B.U.1    Tomasi, D.2    Caparelli, E.C.3
  • 14
    • 0036845658 scopus 로고    scopus 로고
    • Real-time autoshimming for echo planar timecourse imaging
    • Ward HA, Riederer SJ, Jack Jr CR. Real-time autoshimming for echo planar timecourse imaging. Magn Reson Med 2002;48:771-780.
    • (2002) Magn Reson Med , vol.48 , pp. 771-780
    • Ward, H.A.1    Riederer, S.J.2    Jack Jr, C.R.3
  • 15
    • 0003807773 scopus 로고    scopus 로고
    • 4th ed. Upper Saddle River, NJ: Prentice Hall;
    • Haykin SS. Adaptive filter theory. 4th ed. Upper Saddle River, NJ: Prentice Hall; 2002.
    • (2002) Adaptive filter theory
    • Haykin, S.S.1
  • 17
    • 0027499838 scopus 로고
    • Functional MRI of human brain activation at high spatial resolution
    • Frahm J, Merboldt KD, Hanicke W. Functional MRI of human brain activation at high spatial resolution. Magn Reson Med 1993;29:139-144.
    • (1993) Magn Reson Med , vol.29 , pp. 139-144
    • Frahm, J.1    Merboldt, K.D.2    Hanicke, W.3
  • 19
    • 0031759093 scopus 로고    scopus 로고
    • Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla
    • Jesmanowicz A, Bandettini PA, Hyde JS. Single-shot half k-space high-resolution gradient-recalled EPI for fMRI at 3 Tesla. Magn Reson Med 1998;40:754-762.
    • (1998) Magn Reson Med , vol.40 , pp. 754-762
    • Jesmanowicz, A.1    Bandettini, P.A.2    Hyde, J.S.3
  • 20
    • 0030694224 scopus 로고    scopus 로고
    • High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla
    • Thulborn KR, Chang SY, Shen GX, Voyvodic JT. High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla. NMR Biomed 1997;10:183-190.
    • (1997) NMR Biomed , vol.10 , pp. 183-190
    • Thulborn, K.R.1    Chang, S.Y.2    Shen, G.X.3    Voyvodic, J.T.4
  • 21
    • 0038787548 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging: A review of methodological aspects and clinical applications
    • Hennig J, Speck O, Koch MA, Weiller C. Functional magnetic resonance imaging: a review of methodological aspects and clinical applications. J Magn Reson Imaging 2003;18:1-15.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 1-15
    • Hennig, J.1    Speck, O.2    Koch, M.A.3    Weiller, C.4
  • 22
    • 10044235365 scopus 로고    scopus 로고
    • Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field
    • Yang QX, Wang J, Smith MB, Meadowcroft M, Sun X, Eslinger PJ, Golay X. Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field. Magn Reson Med 2004;52:1418-1423.
    • (2004) Magn Reson Med , vol.52 , pp. 1418-1423
    • Yang, Q.X.1    Wang, J.2    Smith, M.B.3    Meadowcroft, M.4    Sun, X.5    Eslinger, P.J.6    Golay, X.7
  • 23
    • 0036328751 scopus 로고    scopus 로고
    • Multiecho segmented EPI with z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI
    • Li Z, Wu G, Zhao X, Luo F, Li SJ. Multiecho segmented EPI with z-shimmed background gradient compensation (MESBAC) pulse sequence for fMRI. Magn Reson Med 2002;48:312-321.
    • (2002) Magn Reson Med , vol.48 , pp. 312-321
    • Li, Z.1    Wu, G.2    Zhao, X.3    Luo, F.4    Li, S.J.5
  • 24
    • 0034099675 scopus 로고    scopus 로고
    • Artifacts in CSI-measurements caused by the drift of the static magnetic field
    • Schmidt O, Widmaier S, Bunse M, Jung WI, Dietze GJ, Lutz O. Artifacts in CSI-measurements caused by the drift of the static magnetic field. MAGMA 2000;10:167-170.
    • (2000) MAGMA , vol.10 , pp. 167-170
    • Schmidt, O.1    Widmaier, S.2    Bunse, M.3    Jung, W.I.4    Dietze, G.J.5    Lutz, O.6
  • 25
    • 0034963565 scopus 로고    scopus 로고
    • Artifact due to B(0) fluctuations in fMRI: Correction using the k-space central line
    • Durand E, van de Moortele PF, Pachot-Clouard M, Le Bihan D. Artifact due to B(0) fluctuations in fMRI: correction using the k-space central line. Magn Reson Med 2001;46:198-201.
    • (2001) Magn Reson Med , vol.46 , pp. 198-201
    • Durand, E.1    van de Moortele, P.F.2    Pachot-Clouard, M.3    Le Bihan, D.4
  • 26
    • 0242439328 scopus 로고    scopus 로고
    • Principles and applications of balanced SSFP techniques
    • Scheffler K, Lehnhardt S. Principles and applications of balanced SSFP techniques. Eur Radiol 2003;13:2409-2418.
    • (2003) Eur Radiol , vol.13 , pp. 2409-2418
    • Scheffler, K.1    Lehnhardt, S.2
  • 29
    • 30344464110 scopus 로고    scopus 로고
    • A simple geometrical description of the TrueFISP ideal transient and steady-state signal
    • Schmitt P, Griswold MA, Gulani V, Haase A, Flentje M, Jakob PM. A simple geometrical description of the TrueFISP ideal transient and steady-state signal. Magn Reson Med 2006;55:177-186.
    • (2006) Magn Reson Med , vol.55 , pp. 177-186
    • Schmitt, P.1    Griswold, M.A.2    Gulani, V.3    Haase, A.4    Flentje, M.5    Jakob, P.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.