메뉴 건너뛰기




Volumn 51, Issue 17, 2006, Pages 4201-4215

Generating positive contrast from off-resonant spins with steady-state free precession magnetic resonance imaging: Theory and proof-of-principle experiments

Author keywords

[No Author keywords available]

Indexed keywords

ABSORPTION RATES; MOLECULAR IMAGING; SIGNAL VOIDS; SPIN RELAXATION; STEADY STATE FREE PRECESSION (SSFP);

EID: 33747595007     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/17/006     Document Type: Article
Times cited : (52)

References (15)
  • 1
    • 0025361232 scopus 로고
    • Bulk magnetic susceptibility shifts in NMR studies of compartmentalized samples: Use of paramagnetic agents
    • Chu A, Xu J B Y, Balschi J A and Springer C S 1990 Bulk magnetic susceptibility shifts in NMR studies of compartmentalized samples: use of paramagnetic agents Magn. Reson. Med. 13 239-62
    • (1990) Magn. Reson. Med. , vol.13 , Issue.2 , pp. 239-262
    • Chu, A.1    Xu, J.B.Y.2    Balschi, J.A.3    Springer, C.S.4
  • 3
    • 14744284705 scopus 로고    scopus 로고
    • Oxygen-sensitive contrast in blood for steady-state free precession imaging
    • Dharmakumar R, Hong J, Plewes D B and Wright G A 2005 Oxygen-sensitive contrast in blood for steady-state free precession imaging Magn. Reson. Med. 53 574-83
    • (2005) Magn. Reson. Med. , vol.53 , Issue.3 , pp. 574-583
    • Dharmakumar, R.1    Hong, J.2    Plewes, D.B.3    Wright, G.A.4
  • 4
    • 21144455189 scopus 로고    scopus 로고
    • Understanding steady-state free precession: A geometric perspective
    • Dharmakumar R and Wright G A 2005 Understanding steady-state free precession: a geometric perspective Conc. Magn. Reson. Part A 26A 110
    • (2005) Conc. Magn. Reson. Part , vol.26 , pp. 110
    • Dharmakumar, R.1    Wright, G.A.2
  • 5
    • 0023600023 scopus 로고
    • Transverse relaxation of solvent protons induced by magnetized spheres: Application to ferritin, erythrocytes, and magnetite
    • Gillis P and Koenig S 1987 Transverse relaxation of solvent protons induced by magnetized spheres: application to ferritin, erythrocytes, and magnetite Magn. Reson. Med. 5 323-45
    • (1987) Magn. Reson. Med. , vol.5 , pp. 323-345
    • Gillis, P.1    Koenig, S.2
  • 10
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck J F 1996 The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds Med. Phys. 23 815-50
    • (1996) Med. Phys. , vol.23 , Issue.6 , pp. 815-850
    • Schenck, J.F.1
  • 11
    • 0141840798 scopus 로고    scopus 로고
    • Passive tracking exploiting local signal conservation: The white marker phenomenon
    • Seppenwoolde J H, Viergever M A and Bakker C J 2003 Passive tracking exploiting local signal conservation: the white marker phenomenon Magn. Reson. Med. 50 784-90
    • (2003) Magn. Reson. Med. , vol.50 , Issue.4 , pp. 784-790
    • Seppenwoolde, J.H.1    Viergever, M.A.2    Bakker, C.J.3
  • 13
    • 33746585840 scopus 로고    scopus 로고
    • Shedding light on the dark spot with IRON-a method that generates positive contrast in the presence of superparamagnetic nanoparticles
    • Stuber M, Gilson W D, Schaer M, Bulte J W and Kraitchman D L 2005 Shedding light on the dark spot with IRON-a method that generates positive contrast in the presence of superparamagnetic nanoparticles Proc. Intl. Soc. Mag. Reson. Med. 13 2608
    • (2005) Proc. Intl. Soc. Mag. Reson. Med. , vol.13 , pp. 2608
    • Stuber, M.1    Gilson, W.D.2    Schaer, M.3    Bulte, J.W.4    Kraitchman, D.L.5
  • 14
    • 0026520830 scopus 로고
    • MRI susceptometry: Image-based measurement of absolute susceptibility of MR contrast agents and human blood
    • Weisskoff R M and Kiihne S 1992 MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood Magn. Reson. Med. 24 375-83
    • (1992) Magn. Reson. Med. , vol.24 , Issue.2 , pp. 375-383
    • Weisskoff, R.M.1    Kiihne, S.2
  • 15
    • 0028321471 scopus 로고
    • Microscopic susceptibility variation and transverse relaxation: Theory and experiment
    • Weisskoff R M, Zuo C S, Boxerman J L and Rosen B R 1994 Microscopic susceptibility variation and transverse relaxation: theory and experiment Magn. Reson. Med. 31 601-10
    • (1994) Magn. Reson. Med. , vol.31 , Issue.6 , pp. 601-610
    • Weisskoff, R.M.1    Zuo, C.S.2    Boxerman, J.L.3    Rosen, B.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.