메뉴 건너뛰기




Volumn 14, Issue 2, 2011, Pages 165-174

Towards validation of computational analyses of peri-implant displacements by means of experimentally obtained displacement maps

Author keywords

Deformable image registration; Local validation; Micro finite element ( FE) analysis; Screw implant; Strain mapping

Indexed keywords

COMPUTATIONAL ANALYSIS; DEFORMABLE IMAGE REGISTRATION; DISPLACEMENT FIELD; DISPLACEMENT MAPS; FE ANALYSIS; FEMORAL HEADS; FINITE ELEMENT; LOCAL VALIDATION; MEAN DISPLACEMENT; MECHANICAL INTERACTIONS; PERI-IMPLANT BONES; SMALL DISPLACEMENT; STRAIN MAPPING; VOLUMES OF INTERESTS;

EID: 79951752750     PISSN: 10255842     EISSN: 14768259     Source Type: Journal    
DOI: 10.1080/10255842.2010.537263     Document Type: Article
Times cited : (17)

References (30)
  • 1
    • 39749148437 scopus 로고    scopus 로고
    • A scalable multi-level preconditioner for matrix-free μ-finite element analysis of human bone structures
    • Arbenz P, van Lenthe GH, Mennel U, Müller R, Sala M. 2008. A scalable multi-level preconditioner for matrix-free μ-finite element analysis of human bone structures. Int J Numer Methods Eng. 73:927-947.
    • (2008) Int J Numer Methods Eng , vol.73 , pp. 927-947
    • Arbenz, P.1    van Lenthe, G.H.2    Mennel, U.3    Müller, R.4    Sala, M.5
  • 2
    • 0036096934 scopus 로고    scopus 로고
    • A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures
    • Augat P, Rapp S, Claes L. 2002. A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma. 16(5):311-316.
    • (2002) J Orthop Trauma , vol.16 , Issue.5 , pp. 311-316
    • Augat, P.1    Rapp, S.2    Claes, L.3
  • 3
    • 0027347366 scopus 로고
    • Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis
    • Barrios C, Broström LA, Stark A, Walheim G. 1993. Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis. J Orthop Trauma. 7(5):438-442.
    • (1993) J Orthop Trauma , vol.7 , Issue.5 , pp. 438-442
    • Barrios, C.1    Broström, L.A.2    Stark, A.3    Walheim, G.4
  • 4
    • 0028942010 scopus 로고
    • Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone
    • Bay BK. 1995. Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone. J Orthop Res. 13(2):258-267.
    • (1995) J Orthop Res , vol.13 , Issue.2 , pp. 258-267
    • Bay, B.K.1
  • 5
    • 0032695303 scopus 로고    scopus 로고
    • Digital volume correlation: three-dimensional strain mapping using X-ray tomography
    • Bay BK, Smith TS, Fyhrie DP, Saad M. 1999. Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech. 39(3):217-226.
    • (1999) Exp Mech , vol.39 , Issue.3 , pp. 217-226
    • Bay, B.K.1    Smith, T.S.2    Fyhrie, D.P.3    Saad, M.4
  • 7
    • 75749134043 scopus 로고    scopus 로고
    • A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model
    • Chatzistergos PE, Magnissalis EA, Kourkoulis SK. 2010. A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model. Med Eng Phys. 32(2):145-154.
    • (2010) Med Eng Phys , vol.32 , Issue.2 , pp. 145-154
    • Chatzistergos, P.E.1    Magnissalis, E.A.2    Kourkoulis, S.K.3
  • 8
    • 79951733812 scopus 로고    scopus 로고
    • Validation of a novel strain mapping algorithm based on deformable registration of uCT images
    • Christen D, Voide R, van Lenthe GH, Boyd S, Müller R. 2008. Validation of a novel strain mapping algorithm based on deformable registration of uCT images. J Biomech. 41:S222.
    • (2008) J Biomech , vol.41
    • Christen, D.1    Voide, R.2    van Lenthe, G.H.3    Boyd, S.4    Müller, R.5
  • 9
    • 77953384909 scopus 로고    scopus 로고
    • Endosseous implant anchorage is critically dependent on mechanostructural determinants of peri-implant bone trabeculae
    • Gabet Y, Kohavi D, Voide R, Mueller TL, Müller R, Bab I. 2010. Endosseous implant anchorage is critically dependent on mechanostructural determinants of peri-implant bone trabeculae. J Bone Miner Res. 25(3):575-583.
    • (2010) J Bone Miner Res , vol.25 , Issue.3 , pp. 575-583
    • Gabet, Y.1    Kohavi, D.2    Voide, R.3    Mueller, T.L.4    Müller, R.5    Bab, I.6
  • 11
    • 43249083275 scopus 로고    scopus 로고
    • Influence of osteoporosis on fracture fixation - a systematic literature review
    • Goldhahn J, Suhm N, Goldhahn S, Blauth M, Hanson B. 2008. Influence of osteoporosis on fracture fixation - a systematic literature review. Osteoporos Int. 19(6):761-772.
    • (2008) Osteoporos Int , vol.19 , Issue.6 , pp. 761-772
    • Goldhahn, J.1    Suhm, N.2    Goldhahn, S.3    Blauth, M.4    Hanson, B.5
  • 12
    • 68149132172 scopus 로고    scopus 로고
    • Whole bone strain quantification by image registration: a validation study
    • Hardisty MR, Whyne CM. 2009. Whole bone strain quantification by image registration: a validation study. J Biomech Eng. 131(6):064502.
    • (2009) J Biomech Eng , vol.131 , Issue.6 , pp. 064502
    • Hardisty, M.R.1    Whyne, C.M.2
  • 13
    • 35448994849 scopus 로고    scopus 로고
    • Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone
    • Liu L, Morgan EF. 2007. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. J Biomech. 40(15):3516-3520.
    • (2007) J Biomech , vol.40 , Issue.15 , pp. 3516-3520
    • Liu, L.1    Morgan, E.F.2
  • 14
    • 43149096685 scopus 로고    scopus 로고
    • Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method
    • Macneil JA, Boyd SK. 2008. Bone strength at the distal radius can be estimated from high-resolution peripheral quantitative computed tomography and the finite element method. Bone. 42(6):1203-1213.
    • (2008) Bone , vol.42 , Issue.6 , pp. 1203-1213
    • Macneil, J.A.1    Boyd, S.K.2
  • 15
    • 70349299824 scopus 로고    scopus 로고
    • Regional, age and gender differences in architectural measures of bone quality and their correlation to bone mechanical competence in the human radius of an elderly population
    • Mueller TL, van Lenthe GH, Stauber M, Gratzke C, Eckstein F, Müller R. 2009. Regional, age and gender differences in architectural measures of bone quality and their correlation to bone mechanical competence in the human radius of an elderly population. Bone. 45(5):882-891.
    • (2009) Bone , vol.45 , Issue.5 , pp. 882-891
    • Mueller, T.L.1    van Lenthe, G.H.2    Stauber, M.3    Gratzke, C.4    Eckstein, F.5    Müller, R.6
  • 16
    • 0028797962 scopus 로고
    • Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
    • Müller R, Rüegsegger P. 1995. Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures. Med Eng Phys. 17(2):126-133.
    • (1995) Med Eng Phys , vol.17 , Issue.2 , pp. 126-133
    • Müller, R.1    Rüegsegger, P.2
  • 17
    • 0032467389 scopus 로고    scopus 로고
    • Micro-compression: a novel technique for the nondestructive assessment of local bone failure
    • Müller R, Gerber SC, Hayes WC. 1998. Micro-compression: a novel technique for the nondestructive assessment of local bone failure. Technol Health Care. 6(5-6):433-444.
    • (1998) Technol Health Care , vol.6 , Issue.5-6 , pp. 433-444
    • Müller, R.1    Gerber, S.C.2    Hayes, W.C.3
  • 18
    • 0345735674 scopus 로고    scopus 로고
    • Time-lapsed microstructural imaging of bone failure behavior
    • Nazarian A, Müller R. 2004. Time-lapsed microstructural imaging of bone failure behavior. J Biomech. 37(1):55-65.
    • (2004) J Biomech , vol.37 , Issue.1 , pp. 55-65
    • Nazarian, A.1    Müller, R.2
  • 19
    • 0025781444 scopus 로고
    • The underestimation of Young's modulus in compressive testing of cancellous bone specimens
    • Odgaard A, Linde F. 1991. The underestimation of Young's modulus in compressive testing of cancellous bone specimens. J Biomech. 24(8):691-698.
    • (1991) J Biomech , vol.24 , Issue.8 , pp. 691-698
    • Odgaard, A.1    Linde, F.2
  • 20
    • 0024892629 scopus 로고
    • Compressive axial strain distributions in cancellous bone specimens
    • Odgaard A, Hvid I, Linde F. 1989. Compressive axial strain distributions in cancellous bone specimens. J Biomech. 22(8-9):829-835.
    • (1989) J Biomech , vol.22 , Issue.8-9 , pp. 829-835
    • Odgaard, A.1    Hvid, I.2    Linde, F.3
  • 21
    • 53149130144 scopus 로고    scopus 로고
    • European society of biomechanics S M. Perren award 2008 using temporal trends of 3D bone micro-architecture to predict bone quality
    • Pauchard Y, Mattmann C, Kuhn A, Gasser JA, Boyd SK. 2008. European society of biomechanics S.M. Perren award 2008: using temporal trends of 3D bone micro-architecture to predict bone quality. J Biomech. 41(14):2946-2953.
    • (2008) J Biomech , vol.41 , Issue.14 , pp. 2946-2953
    • Pauchard, Y.1    Mattmann, C.2    Kuhn, A.3    Gasser, J.A.4    Boyd, S.K.5
  • 22
    • 79751536870 scopus 로고    scopus 로고
    • In vivo microcomputed tomography allows direct three-dimensional quantification of both bone formation and bone resorption parameters using time-lapsed imaging
    • doi:10.1016/j.bone.2010.10.007
    • Schulte FA, Lambers FM, Kuhn G, Müler R. 2010. In vivo microcomputed tomography allows direct three-dimensional quantification of both bone formation and bone resorption parameters using time-lapsed imaging. Bone. doi:10.1016/j.bone.2010.10.007.
    • (2010) Bone
    • Schulte, F.A.1    Lambers, F.M.2    Kuhn, G.3    Müler, R.4
  • 23
    • 0036753387 scopus 로고    scopus 로고
    • Digital volume correlation including rotational degrees of freedom during minimization
    • Smith TS, Bay BK, Rashid MM. 2002. Digital volume correlation including rotational degrees of freedom during minimization. Exp Mech. 42(3):272-278.
    • (2002) Exp Mech , vol.42 , Issue.3 , pp. 272-278
    • Smith, T.S.1    Bay, B.K.2    Rashid, M.M.3
  • 24
    • 0032153006 scopus 로고    scopus 로고
    • Image matching as a diffusion process: an analogy with Maxwell's demons
    • Thirion JP. 1998. Image matching as a diffusion process: an analogy with Maxwell's demons. Med Image Anal. 2(3): 243-260.
    • (1998) Med Image Anal , vol.2 , Issue.3 , pp. 243-260
    • Thirion, J.P.1
  • 25
    • 58649094180 scopus 로고    scopus 로고
    • Validation of subjectspecific automated p-FE analysis of the proximal femur
    • Trabelsi N, Yosibash Z, Milgrom C. 2009. Validation of subjectspecific automated p-FE analysis of the proximal femur. J Biomech. 42(3):234-241.
    • (2009) J Biomech , vol.42 , Issue.3 , pp. 234-241
    • Trabelsi, N.1    Yosibash, Z.2    Milgrom, C.3
  • 26
    • 3242739346 scopus 로고    scopus 로고
    • A threedimensional digital image correlation technique for strain measurements in microstructures
    • Verhulp E, van Rietbergen B, Huiskes R. 2004. A threedimensional digital image correlation technique for strain measurements in microstructures. J Biomech. 37(9): 1313-1320.
    • (2004) J Biomech , vol.37 , Issue.9 , pp. 1313-1320
    • Verhulp, E.1    van Rietbergen, B.2    Huiskes, R.3
  • 27
    • 0037382942 scopus 로고    scopus 로고
    • Burst fracture in the metastatically involved spine: development, validation, and parametric analysis of a three-dimensional poroelastic finiteelement model
    • Whyne CM, Hu SS, Lotz JC. 2003. Burst fracture in the metastatically involved spine: development, validation, and parametric analysis of a three-dimensional poroelastic finiteelement model. Spine. 28(7):652-660.
    • (2003) Spine , vol.28 , Issue.7 , pp. 652-660
    • Whyne, C.M.1    Hu, S.S.2    Lotz, J.C.3
  • 28
    • 77952009543 scopus 로고    scopus 로고
    • Mechanical competence of bone-implant systems can accurately be determined by image-based micro-finite element analyses
    • Wirth AJ, Mueller TL, Vereecken W, Flaig C, Arbenz P, Müller R, van Lenthe GH. 2010. Mechanical competence of bone-implant systems can accurately be determined by image-based micro-finite element analyses. Arch Appl Mech. 80:513-525.
    • (2010) Arch Appl Mech , vol.80 , pp. 513-525
    • Wirth, A.J.1    Mueller, T.L.2    Vereecken, W.3    Flaig, C.4    Arbenz, P.5    Müller, R.6    van Lenthe, G.H.7
  • 29
    • 33645707138 scopus 로고    scopus 로고
    • Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements
    • Zauel R, Yeni YN, Bay BK, Dong XN, Fyhrie DP. 2006. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements. J Biomech Eng. 128(1):1-6.
    • (2006) J Biomech Eng , vol.128 , Issue.1 , pp. 1-6
    • Zauel, R.1    Yeni, Y.N.2    Bay, B.K.3    Dong, X.N.4    Fyhrie, D.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.