메뉴 건너뛰기




Volumn 41, Issue 14, 2008, Pages 2946-2953

European Society of Biomechanics S.M. Perren Award 2008: Using temporal trends of 3D bone micro-architecture to predict bone quality

Author keywords

Finite element modeling; In vivo micro CT; Morphological parameters; Trabecular bone analysis

Indexed keywords

BIOMECHANICS; BONE; COMPUTERIZED TOMOGRAPHY; DEFORMATION; DIAGNOSTIC RADIOGRAPHY; ERROR ANALYSIS; EXTRAPOLATION; FINITE ELEMENT METHOD; IMAGE REGISTRATION; MEDICAL IMAGING; THREE DIMENSIONAL; TOMOGRAPHY;

EID: 53149130144     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2008.07.036     Document Type: Article
Times cited : (13)

References (31)
  • 1
    • 34247647987 scopus 로고    scopus 로고
    • First meeting on bone quality, Abbaye des Vaux de Cernay, France, 15-16 June 2006: bone architecture
    • Benhamou C.-L., and Roux C. First meeting on bone quality, Abbaye des Vaux de Cernay, France, 15-16 June 2006: bone architecture. Osteoporosis International 18 6 (2007) 837-889
    • (2007) Osteoporosis International , vol.18 , Issue.6 , pp. 837-889
    • Benhamou, C.-L.1    Roux, C.2
  • 2
    • 33748162992 scopus 로고    scopus 로고
    • Monitoring individual morphological changes over time in ovariectomized rats by in vivo micro-computed tomography
    • Boyd S.K., Davison P., Müller R., and Gasser J.A. Monitoring individual morphological changes over time in ovariectomized rats by in vivo micro-computed tomography. Bone 39 (2006) 854-862
    • (2006) Bone , vol.39 , pp. 854-862
    • Boyd, S.K.1    Davison, P.2    Müller, R.3    Gasser, J.A.4
  • 4
    • 41049086665 scopus 로고    scopus 로고
    • Bone degeneration and recovery after early and late bisphosphonate treatment of ovariectomized wistar rats assessed by in vivo micro-computed tomography
    • Brouwers J.E., Lambers F.M., Gasser J.A., van Rietbergen B., and Huiskes R. Bone degeneration and recovery after early and late bisphosphonate treatment of ovariectomized wistar rats assessed by in vivo micro-computed tomography. Calcified Tissue International 82 3 (2008) 202-211
    • (2008) Calcified Tissue International , vol.82 , Issue.3 , pp. 202-211
    • Brouwers, J.E.1    Lambers, F.M.2    Gasser, J.A.3    van Rietbergen, B.4    Huiskes, R.5
  • 5
    • 56749177508 scopus 로고    scopus 로고
    • Buie, H.R., Moore, C.P., Boyd, S.K., 2008. Post-pubertal architectural developmental patterns differ between the L3 vertebra and proximal tibia in three inbred strains of mice. Journal of Bone and Mineral Research, in press.
    • Buie, H.R., Moore, C.P., Boyd, S.K., 2008. Post-pubertal architectural developmental patterns differ between the L3 vertebra and proximal tibia in three inbred strains of mice. Journal of Bone and Mineral Research, in press.
  • 7
    • 0021388724 scopus 로고
    • Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor
    • Harrigan T.P., and Mann R.W. Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor. Journal of Materials Science 19 (1984) 761-767
    • (1984) Journal of Materials Science , vol.19 , pp. 761-767
    • Harrigan, T.P.1    Mann, R.W.2
  • 8
    • 0031020931 scopus 로고    scopus 로고
    • A new method for the model-independent assessment of thickness in three-dimensional images
    • Hildebrand T., and Rüegsegger P. A new method for the model-independent assessment of thickness in three-dimensional images. Journal of Microscopy 185 (1997) 67-75
    • (1997) Journal of Microscopy , vol.185 , pp. 67-75
    • Hildebrand, T.1    Rüegsegger, P.2
  • 10
    • 0034621881 scopus 로고    scopus 로고
    • Effects of mechanical forces on maintenance and adaption of form in trabecular bone
    • Huiskes R., Ruimerman R., van Lenthe G.H., and Janssen J.D. Effects of mechanical forces on maintenance and adaption of form in trabecular bone. Nature 405 (2000) 704-706
    • (2000) Nature , vol.405 , pp. 704-706
    • Huiskes, R.1    Ruimerman, R.2    van Lenthe, G.H.3    Janssen, J.D.4
  • 12
    • 0035658186 scopus 로고    scopus 로고
    • The temporal changes of trabecular architecture in ovariectomized rats assessed by MicroCT
    • Laib A., Kumer J.L., Majumdar S., and Lane N.E. The temporal changes of trabecular architecture in ovariectomized rats assessed by MicroCT. Osteoporosis International 12 (2001) 936-941
    • (2001) Osteoporosis International , vol.12 , pp. 936-941
    • Laib, A.1    Kumer, J.L.2    Majumdar, S.3    Lane, N.E.4
  • 13
    • 34250018006 scopus 로고    scopus 로고
    • Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    • MacNeil J.A., and Boyd S.K. Accuracy of high-resolution peripheral quantitative computed tomography for measurement of bone quality. Medical Engineering & Physics 29 10 (2007) 1096-1105
    • (2007) Medical Engineering & Physics , vol.29 , Issue.10 , pp. 1096-1105
    • MacNeil, J.A.1    Boyd, S.K.2
  • 14
    • 34250013862 scopus 로고    scopus 로고
    • Load distribution and the predictive power of morphological indices in the distal radius and tibia by high resolution peripheral quantitative computed tomography
    • MacNeil J.A., and Boyd S.K. Load distribution and the predictive power of morphological indices in the distal radius and tibia by high resolution peripheral quantitative computed tomography. Bone 41 (2007) 129-137
    • (2007) Bone , vol.41 , pp. 129-137
    • MacNeil, J.A.1    Boyd, S.K.2
  • 15
    • 43149083839 scopus 로고    scopus 로고
    • Improved reproducibility of high resolution peripheral quantitative computed tomography for measurement of bone quality
    • MacNeil J.A., and Boyd S.K. Improved reproducibility of high resolution peripheral quantitative computed tomography for measurement of bone quality. Medical Engineering & Physics 30 6 (2008) 792-799
    • (2008) Medical Engineering & Physics , vol.30 , Issue.6 , pp. 792-799
    • MacNeil, J.A.1    Boyd, S.K.2
  • 16
    • 0036815297 scopus 로고    scopus 로고
    • The Zürich experience: one decade of three-dimensional high-resolution computed tomography
    • Müller R. The Zürich experience: one decade of three-dimensional high-resolution computed tomography. Topics in Magnetic Resonance Imaging 13 5 (2002) 307-322
    • (2002) Topics in Magnetic Resonance Imaging , vol.13 , Issue.5 , pp. 307-322
    • Müller, R.1
  • 17
    • 26944496131 scopus 로고    scopus 로고
    • Longterm prediction of three-dimensional bone architecture in simulations of pre-, peri- and post-menopausal microstructural bone remodelling
    • Müller R. Longterm prediction of three-dimensional bone architecture in simulations of pre-, peri- and post-menopausal microstructural bone remodelling. Osteoporosis International 16 Suppl. 2 (2005) S25-S35
    • (2005) Osteoporosis International , vol.16 , Issue.SUPPL. 2
    • Müller, R.1
  • 18
    • 0028797962 scopus 로고
    • Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
    • Müller R., and Rüegsegger P. Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures. Medical Engineering & Physics 17 2 (1995) 126-133
    • (1995) Medical Engineering & Physics , vol.17 , Issue.2 , pp. 126-133
    • Müller, R.1    Rüegsegger, P.2
  • 20
    • 0027417991 scopus 로고
    • Quantification of connectivity in cancellous bone, with special emphasis on 3-d reconstructions
    • Odgaard A., and Gundersen H.J. Quantification of connectivity in cancellous bone, with special emphasis on 3-d reconstructions. Bone 14 (1993) 173-182
    • (1993) Bone , vol.14 , pp. 173-182
    • Odgaard, A.1    Gundersen, H.J.2
  • 21
    • 0036978681 scopus 로고    scopus 로고
    • A 3-dimensional computer model to simulate trabecular bone metabolism
    • Ruimerman R., van Rietbergen B., Hilbers P., and Huiskes R. A 3-dimensional computer model to simulate trabecular bone metabolism. Biorheology 40 (2003) 315-320
    • (2003) Biorheology , vol.40 , pp. 315-320
    • Ruimerman, R.1    van Rietbergen, B.2    Hilbers, P.3    Huiskes, R.4
  • 22
    • 53149127353 scopus 로고    scopus 로고
    • Thirion, J.-P., 1995. Fast non-rigid matching of 3d medical images. Technical Report 2547, INRIA Sophia Antipolis, France.
    • Thirion, J.-P., 1995. Fast non-rigid matching of 3d medical images. Technical Report 2547, INRIA Sophia Antipolis, France.
  • 23
    • 0032153006 scopus 로고    scopus 로고
    • Image matching as a diffusion process: an analogy with Maxwell's demons
    • Thirion J.-P. Image matching as a diffusion process: an analogy with Maxwell's demons. Medical Image Analysis 2 3 (1998) 243-260
    • (1998) Medical Image Analysis , vol.2 , Issue.3 , pp. 243-260
    • Thirion, J.-P.1
  • 24
    • 0032995520 scopus 로고    scopus 로고
    • The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone
    • Ulrich D., van Rietbergen B., Laib A., and Rüegsegger P. The ability of three-dimensional structural indices to reflect mechanical aspects of trabecular bone. Bone 25 1 (1999) 55-60
    • (1999) Bone , vol.25 , Issue.1 , pp. 55-60
    • Ulrich, D.1    van Rietbergen, B.2    Laib, A.3    Rüegsegger, P.4
  • 25
    • 0028936206 scopus 로고
    • A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models
    • van Rietbergen B., Weinans H., Huiskes R., and Odgaard A. A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. Journal of Biomechanics 28 1 (1995) 69-81
    • (1995) Journal of Biomechanics , vol.28 , Issue.1 , pp. 69-81
    • van Rietbergen, B.1    Weinans, H.2    Huiskes, R.3    Odgaard, A.4
  • 26
    • 0030561004 scopus 로고    scopus 로고
    • Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture
    • van Rietbergen B., Odgaard A., Kabel J., and Huiskes R. Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. Journal of Biomechanics 29 12 (1996) 1653-1657
    • (1996) Journal of Biomechanics , vol.29 , Issue.12 , pp. 1653-1657
    • van Rietbergen, B.1    Odgaard, A.2    Kabel, J.3    Huiskes, R.4
  • 28
    • 0036146823 scopus 로고    scopus 로고
    • High-resolution MRI and micro-FE for the evaluation of changes in bone mechanical properties during longitudinal clinical trials: application to calcaneal bone in postmenopausal women after one year of idoxifene treatment
    • van Rietbergen B., Majumdar S., Newitt D., and MacDonald B. High-resolution MRI and micro-FE for the evaluation of changes in bone mechanical properties during longitudinal clinical trials: application to calcaneal bone in postmenopausal women after one year of idoxifene treatment. Clinical Biomechanics 17 (2002) 81-88
    • (2002) Clinical Biomechanics , vol.17 , pp. 81-88
    • van Rietbergen, B.1    Majumdar, S.2    Newitt, D.3    MacDonald, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.