메뉴 건너뛰기




Volumn 34, Issue 2, 2011, Pages 468-470

Relationship between carotid intima-media thickness and the presence and extent of coronary stenosis in type 2 diabetic patients with carotid atherosclerosis but without history of coronary artery disease

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTERIAL WALL THICKNESS; ARTICLE; CAROTID ATHEROSCLEROSIS; CORONARY ARTERY OBSTRUCTION; DIABETIC PATIENT; DISEASE ASSOCIATION; DYSLIPIDEMIA; FEMALE; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; NON INSULIN DEPENDENT DIABETES MELLITUS;

EID: 79951712612     PISSN: 01495992     EISSN: 19355548     Source Type: Journal    
DOI: 10.2337/dc10-1222     Document Type: Article
Times cited : (33)

References (9)
  • 1
    • 57149121037 scopus 로고    scopus 로고
    • Diagnostic performance of coronary angiography by 64-row CT
    • Miller JM, Rochitte CE, Dewey M, et al. Diagnostic performance of coronary angiography by 64-row CT. N Engl J Med 2008; 359:2324-2336
    • (2008) N Engl J Med , vol.359 , pp. 2324-2336
    • Miller, J.M.1    Rochitte, C.E.2    Dewey, M.3
  • 2
    • 54549122949 scopus 로고    scopus 로고
    • Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: Results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial
    • Budoff MJ, DoweD, Jollis JG, et al. Diagnostic performance of 64-multidetector row coronary computed tomographic angiography for evaluation of coronary artery stenosis in individuals without known coronary artery disease: results from the prospective multicenter ACCURACY (Assessment by Coronary Computed Tomographic Angiography of Individuals Undergoing Invasive Coronary Angiography) trial. J Am Coll Cardiol 2008; 52:1724-1732
    • (2008) J Am Coll Cardiol , vol.52 , pp. 1724-1732
    • Budoff, M.J.1    Dowe, D.2    Jollis, J.G.3
  • 3
    • 57449115879 scopus 로고    scopus 로고
    • Diagnostic accuracy of 64-slice computed tomography coronary angiography: A prospective, multicenter, multivendor study
    • Meijboom WB, Meijs MF, Schuijf JD, et al. Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 2008;16:2135-2144
    • (2008) J Am Coll Cardiol , vol.16 , pp. 2135-2144
    • Meijboom, W.B.1    Meijs, M.F.2    Schuijf, J.D.3
  • 7
    • 75149180515 scopus 로고    scopus 로고
    • Standards of medical care in diabetes - 2010
    • American Diabetes Association
    • American Diabetes Association. Standards of medical care in diabetes - 2010. Diabetes Care 2010;33(Suppl. 1):S11-S61
    • (2010) Diabetes Care , vol.33 , Issue.SUPPL. 1
  • 9
    • 84855627105 scopus 로고    scopus 로고
    • Carotid ultrasound examination
    • The Joint Committee of "The Japan Academy of Neurosonology" and "The Japan Society of Embolus Detection and Treatment" on Guideline for Neurosonology
    • The Joint Committee of "The Japan Academy of Neurosonology" and "The Japan Society of Embolus Detection and Treatment" on Guideline for Neurosonology. Carotid ultrasound examination. Neurosonology 2006;19:49-69
    • (2006) Neurosonology , vol.19 , pp. 49-69


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.