메뉴 건너뛰기




Volumn 56, Issue 4, 2011, Pages 979-999

Quality control measurements for digital x-ray detectors

Author keywords

[No Author keywords available]

Indexed keywords

AIR KERMA; CAESIUM IODIDE; CIRCULAR DISCS; COEFFICIENT OF VARIATION; DEPTH ASSESSMENT; DETECTABILITY; DETECTIVE QUANTUM EFFICIENCY; DETECTOR PERFORMANCE; DETECTOR RESPONSE; DIGITAL RADIOGRAPHY; DIGITAL SYSTEM; DIGITAL X-RAY DETECTOR; IMAGE TRANSFER; IMAGING PERFORMANCE; IMAGING TECHNOLOGY; INSTITUTE OF PHYSICS; MODULATION TRANSFER FUNCTION; NORMALIZED NOISE POWER SPECTRUM; OPTICAL DENSITIES; QUALITY CONTROL MEASUREMENT; QUALITY CONTROL PROTOCOL; REPRODUCIBILITIES; SCREEN/FILM SYSTEM; SPATIAL FREQUENCY; TARGET DETECTORS; X RAY SPECTRUM;

EID: 79551705516     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/4/007     Document Type: Article
Times cited : (27)

References (36)
  • 1
    • 0042079085 scopus 로고    scopus 로고
    • Assessment of display performance for medical imaging systems
    • AAPM American Association of Physicists in Medicine Task Group 18, College Park, MD: AAPM
    • AAPM (American Association of Physicists in Medicine Task Group 18) 2005 Assessment of display performance for medical imaging systems AAPM On-line Report 03 (College Park, MD: AAPM)
    • (2005) AAPM On-line Report 03
  • 3
    • 0032767558 scopus 로고    scopus 로고
    • Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
    • DOI 10.1118/1.598630
    • Aufrichtig R 1999 Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography Med. Phys. 26 1349-58 (Pubitemid 29334803)
    • (1999) Medical Physics , vol.26 , Issue.7 , pp. 1349-1358
    • Aufrichtig, R.1
  • 4
    • 0038033836 scopus 로고    scopus 로고
    • On site evaluation of three flat panel detectors for digital radiography
    • DOI 10.1118/1.1569273
    • Borasi G, Nitrosi A, Ferrari P and Tassoni D 2003 On site evaluation of three flat panel detectors for digital radiography Med. Phys. 30 1719-31 (Pubitemid 36885789)
    • (2003) Medical Physics , vol.30 , Issue.7 , pp. 1719-1731
    • Borasi, G.1    Nitrosi, A.2    Ferrari, P.3    Tassoni, D.4
  • 5
    • 33744819202 scopus 로고    scopus 로고
    • Contrast-detail analysis of three flat panel detectors for digital radiography
    • DOI 10.1118/1.2191014
    • Borasi G, Samei E, Bertolini M, Nitrosi A and Tassoni D 2006 Contrast-detail analysis of three flat panel detectors for digital radiography Med. Phys. 33 1707-19 (Pubitemid 43830259)
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1707-1719
    • Borasi, G.1    Samei, E.2    Bertolini, M.3    Nitrosi, A.4    Tassoni, D.5
  • 7
    • 34547431620 scopus 로고    scopus 로고
    • Digital detectors for general radiography. A comparative technical report
    • CEP Centre for Evidence-based Purchasing, and, London: CEP
    • CEP (Centre for Evidence-based Purchasing) Lawinski C P, Mackenzie A, Cole H, Blake P and Honey I D 2005 Digital detectors for general radiography. A comparative technical report Report 05078 (London: CEP)
    • (2005) Report 05078
    • Lawinski, C.P.1    Mackenzie, A.2    Cole, H.3    Blake, P.4    Honey, I.D.5
  • 8
    • 0021164719 scopus 로고
    • Analysis of variations in contrast-detail experiments
    • DOI 10.1118/1.595539
    • Cohen G, McDaniel D L and Wagner L K 1984 Analysis of variations in contrast-detail experiments Med. Phys. 11 469-473 (Pubitemid 14057398)
    • (1984) Medical Physics , vol.11 , Issue.4 , pp. 469-473
    • Cohen, G.1    McDaniel, D.L.2    Wagner, L.K.3
  • 9
    • 0023242518 scopus 로고
    • A set of X-ray test objects for image quality control in digital subtraction fluorography. I: Design considerations
    • Cowen A R, Haywood J M, Workman A and Clarke O F 1987 A set of x-ray test objects for image quality control in digital subtraction fluorography: I. Design considerations B r. J. Radiol. 60 1001-9 (Pubitemid 17145894)
    • (1987) British Journal of Radiology , vol.60 , Issue.718 , pp. 1001-1009
    • Cowen, A.R.1    Haywood, J.M.2    Workman, A.3    Clarke, O.F.4
  • 11
    • 0002050483 scopus 로고    scopus 로고
    • Applied linear system theory
    • ed J Beutel, H L Kundel and R L Van Metter Bellingham, WA: SPIE
    • Cunningham I A 2000 Applied linear system theory Physics and Psychophysics vol 1 ed J Beutel, H L Kundel and R L Van Metter (Bellingham, WA: SPIE) pp 79-159
    • (2000) Physics and Psychophysics , vol.1 , pp. 79-159
    • Cunningham, I.A.1
  • 12
    • 43149115658 scopus 로고    scopus 로고
    • Use of the detective quantum efficiencyin aquality assurance program
    • Cunningham I A 2008 Use of the detective quantum efficiencyin aquality assurance program Proc. SPIE 6913 69133I
    • (2008) Proc. SPIE , vol.6913
    • Cunningham, I.A.1
  • 14
    • 33646455469 scopus 로고    scopus 로고
    • Intercomparison of methods for image quality characterization: II. Noise power spectrum
    • Dobbins J T 3rd, Samei E, Ranger N T and Chen Y 2006 Intercomparison of methods for image quality characterization: II. Noise power spectrum Med. Phys. 33 1466-75
    • (2006) Med. Phys. , vol.33 , pp. 1466-1475
    • Dobbins III, J.T.1    Samei, E.2    Ranger, N.T.3    Chen, Y.4
  • 15
    • 6344282672 scopus 로고    scopus 로고
    • Threshold contrast detail detectability curves for fluoroscopy and digital acquisition using modern image intensifier systems
    • DOI 10.1259/bjr/16707499
    • Evans D S, Mackenzie A, Lawinski C P and Smith D 2004 Threshold contrast detail detectability curves for fluoroscopy and digital acquisition using modern image intensifier systems Br. J. Radiol. 77 751-8 (Pubitemid 39386923)
    • (2004) British Journal of Radiology , vol.77 , Issue.921 , pp. 751-758
    • Evans, D.S.1    Mackenzie, A.2    Lawinski, C.P.3    Smith, D.4
  • 16
    • 0036145048 scopus 로고    scopus 로고
    • A comparison of the imaging properties of CCD-based devices used for small field digital mammography
    • DOI 10.1088/0031-9155/47/1/309, PII S0031915502278732
    • Evans D S, Workman A and Payne M 2002 A comparison of the imaging properties of CCD-based devices used for small field digital mammography Phys. Med. Biol. 47 117-35 (Pubitemid 34071352)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.1 , pp. 117-135
    • Evans, D.S.1    Workman, A.2    Payne, M.3
  • 17
    • 68049139345 scopus 로고    scopus 로고
    • Artifacts found during quality assurance testing of computed radiography and digital radiography detectors
    • Honey I D and Mackenzie A 2009 Artifacts found during quality assurance testing of computed radiography and digital radiography detectors J. Digit. Imaging 22 383-92
    • (2009) J. Digit. Imaging , vol.22 , pp. 383-392
    • Honey, I.D.1    Mackenzie, A.2
  • 18
    • 33746115896 scopus 로고    scopus 로고
    • Recommended standards for the routine performance testing of diagnostic x-ray imaging systems
    • IPEM, York: IPEM
    • Hiles P, Mackenzie A, Scally A, Wall B and IPEM 2005 Recommended standards for the routine performance testing of diagnostic x-ray imaging systems IPEM Report 91 (York: IPEM)
    • (2005) IPEM Report 91
    • Hiles, P.1    Mackenzie, A.2    Scally, A.3    Wall, B.4
  • 19
    • 66749153645 scopus 로고    scopus 로고
    • Medical electrical equipment characteristics of digital x-ray image devices-part 1. Determination of the detective quantum efficiency
    • IEC International Electrotechnical Commission, Geneva: International Electrotechnical Commission
    • IEC (International Electrotechnical Commission) 2003 Medical electrical equipment characteristics of digital x-ray image devices-part 1. Determination of the detective quantum efficiency IEC 62220-1 (Geneva: International Electrotechnical Commission)
    • (2003) IEC 62220-1
  • 20
    • 0003696431 scopus 로고    scopus 로고
    • Medical diagnostic x-ray equipment-radiation conditions for use in the determination of characteristics
    • IEC International Electrotechnical Commission, Geneva: International Electrotechnical Commission
    • IEC (International Electrotechnical Commission) 2005 Medical diagnostic x-ray equipment-radiation conditions for use in the determination of characteristics IEC 61267 (Geneva: International Electrotechnical Commission)
    • (2005) IEC 61267
  • 21
    • 84873831868 scopus 로고    scopus 로고
    • Measurement of the performance characteristics of diagnostic x-ray systems: Digital imaging systems
    • IPEM, Part VII York: IPEM
    • Mackenzie A, Doshi S, Doyle P, Hill A, Honey I, Marshall N, O'Neill J, Smail M and IPEM 2010 Measurement of the performance characteristics of diagnostic x-ray systems: digital imaging systems IPEM Report 32 (Part VII) (York: IPEM)
    • (2010) IPEM Report 32
    • Mackenzie, A.1    Doshi, S.2    Doyle, P.3    Hill, A.4    Honey, I.5    Marshall, N.6    O'Neill, J.7    Smail, M.8
  • 22
    • 42449119841 scopus 로고    scopus 로고
    • Validation of correction methods for the non-linear response of digital radiography systems
    • DOI 10.1259/bjr/57141560
    • Mackenzie A 2008 Validation of correction methods for the non-linear response of digital radiography systems Br. J. Radiol. 81 341-5 (Pubitemid 351702964)
    • (2008) British Journal of Radiology , vol.81 , Issue.964 , pp. 341-345
    • Mackenzie, A.1
  • 23
    • 34547417197 scopus 로고    scopus 로고
    • Characterization of noise sources for two generations of computed radiography systems using powder and crystalline photostimulable phosphors
    • DOI 10.1118/1.2750973
    • Mackenzie A and Honey I D 2007 Characterization of noise sources for two generations of computed radiography systems using powder and crystalline photostimulable phosphors Med. Phys. 34 3345-57 (Pubitemid 47175801)
    • (2007) Medical Physics , vol.34 , Issue.8 , pp. 3345-3357
    • Mackenzie, A.1    Honey, I.D.2
  • 25
    • 33646485572 scopus 로고    scopus 로고
    • A comparison between objective and subjective image quality measurements for a full field digital mammography system
    • Marshall N W 2006a A comparison between objective and subjective image quality measurements for a full field digital mammography system Phys. Med. Biol. 51 2441-63
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2441-2463
    • Marshall, N.W.1
  • 26
    • 33751172327 scopus 로고    scopus 로고
    • Retrospective analysis of a detector fault for a full field digital mammography system
    • DOI 10.1088/0031-9155/51/21/018, PII S0031915506259219, 018
    • Marshall N W 2006b Retrospective analysis of a detector fault for a full field digital mammography system Phys. Med. Biol. 51 5655-73 (Pubitemid 44773338)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.21 , pp. 5655-5673
    • Marshall, N.W.1
  • 27
    • 35848968890 scopus 로고    scopus 로고
    • Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems
    • DOI 10.1088/0031-9155/52/18/006, PII S003191550749251X
    • Marshall N W 2007 Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems Phys. Med. Biol. 52 5545-68 (Pubitemid 350056683)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.18 , pp. 5545-5568
    • Marshall, N.W.1
  • 29
    • 25444526688 scopus 로고    scopus 로고
    • A comparison of the imaging characteristics of the new Kodak Hyper Speed G film with the current T-MAT G/RA film and the CR 9000 system
    • DOI 10.1088/0031-9155/50/19/008
    • Monnin P, Gutierrez D, Bulling S, Lepori D and Verdun F R 2005 A comparison of the imaging characteristics of the new Kodak Hyper Speed G film with the current T-MAT G/RA film and the CR 9000 system Phys. Med. Biol. 50 4541-52 (Pubitemid 41361516)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.19 , pp. 4541-4552
    • Monnin, P.1    Gutierrez, D.2    Bulling, S.3    Lepori, D.4    Verdun, F.R.5
  • 30
    • 84896078808 scopus 로고    scopus 로고
    • Calculation of quantitative image quality parameters-notes describing the use of OBJ-IQ-reduced equipment
    • NHSBSP National Health Service Breast Screening Programme, Sheffield: NHSBSP
    • NHSBSP (National Health Service Breast Screening Programme) 2009 Calculation of quantitative image quality parameters-notes describing the use of OBJ-IQ-reduced equipment Report 0902 (Sheffield: NHSBSP)
    • (2009) Report 0902
  • 31
    • 0025136283 scopus 로고
    • Effect of various noise sources on the detective quantum efficiency of phosphor screens
    • DOI 10.1118/1.596572
    • Nishikawa R M and Yaffe M J 1990 Effect of various noise sources on the detective quantum efficiency of phosphor screens Med. Phys. 17 887-93 (Pubitemid 20353768)
    • (1990) Medical Physics , vol.17 , Issue.5 , pp. 887-893
    • Nishikawa, R.M.1    Yaffe, M.J.2
  • 32
    • 0020639553 scopus 로고
    • Quantum noise in detectors
    • Rimkus D A and Bailey N A 1983 Quantum noise in detectors Med. Phys. 10 470-1
    • (1983) Med. Phys. , vol.10 , pp. 470-471
    • Rimkus, D.A.1    Bailey, N.A.2
  • 33
    • 0035185721 scopus 로고    scopus 로고
    • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - A contrast-detail phantom study
    • DOI 10.1118/1.1408620
    • Rong X J, Shaw C C, Liu X, Lemacks M R and Thompson S K 2001 Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems - a contrast-detail phantom study Med. Phys. 28 2328-35 (Pubitemid 33095567)
    • (2001) Medical Physics , vol.28 , Issue.11 , pp. 2328-2335
    • Rong, X.J.1    Shaw, C.C.2    Liu, X.3    Lemacks, M.R.4    Thompson, S.K.5
  • 34
    • 0000899259 scopus 로고    scopus 로고
    • Flat panel detectors for digital radiology
    • ed J Beutel, H L Kundel and R L Van Metter Bellingham, WA: SPIE
    • Rowlands J A and Yorkston J 2000 Flat panel detectors for digital radiology Physics and Psychophysics vol 1 ed J Beutel, H L Kundel and R L Van Metter (Bellingham, WA: SPIE) pp 223-328
    • (2000) Physics and Psychophysics , vol.1 , pp. 223-328
    • Rowlands, J.A.1    Yorkston, J.2
  • 35
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • DOI 10.1118/1.1561285
    • Samei E and Flynn M J 2003 An experimental comparison of detector performance for direct and indirect digital radiography systems Med. Phys. 30 608-22 (Pubitemid 36443965)
    • (2003) Medical Physics , vol.30 , Issue.4 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 36
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • DOI 10.1118/1.598165
    • Samei E, Flynn M J and Reimann D A 1998 A method for measuring the presampled MTF of digital radiographic systems using an edge test device Med. Phys. 25 102-13 (Pubitemid 28063694)
    • (1998) Medical Physics , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.