메뉴 건너뛰기




Volumn 51, Issue 21, 2006, Pages 5655-5673

Retrospective analysis of a detector fault for a full field digital mammography system

Author keywords

[No Author keywords available]

Indexed keywords

APPROXIMATION THEORY; ATTENUATION; IMAGE QUALITY; NYQUIST DIAGRAMS; QUANTUM EFFICIENCY; SPATIAL VARIABLES MEASUREMENT; SPURIOUS SIGNAL NOISE;

EID: 33751172327     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/51/21/018     Document Type: Article
Times cited : (15)

References (31)
  • 1
    • 0032767558 scopus 로고    scopus 로고
    • Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
    • Aufrichtig R 1999 Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography Med. Phys. 26 1349-58
    • (1999) Med. Phys. , vol.26 , Issue.7 , pp. 1349-1358
    • Aufrichtig, R.1
  • 4
    • 0021164719 scopus 로고
    • Analysis of variations in contrast-detail experiments
    • Cohen G, McDaniel D L and Wagner L K 1984 Analysis of variations in contrast-detail experiments Med. Phys. 11 469-73
    • (1984) Med. Phys. , vol.11 , Issue.4 , pp. 469-473
    • Cohen, G.1    McDaniel, D.L.2    Wagner, L.K.3
  • 5
    • 0004903352 scopus 로고    scopus 로고
    • Catalogue of Diagnostic X-Ray Spectra and Other Data
    • Cranley K, Gilmore B J, Fogarty G W A and Desponds L 1997 Catalogue of Diagnostic X-Ray Spectra and Other Data IPEM Report 78 (York: Institute of Physics and Engineering in Medicine)
    • (1997) IPEM Report , vol.78
    • Cranley, K.1    Gilmore, B.J.2    Fogarty, G.W.A.3    Desponds, L.4
  • 6
    • 0002050483 scopus 로고    scopus 로고
    • Applied linear systems theory
    • Cunningham I A 2000 Applied linear systems theory Physics and Psychophysics ed J Beutel, H L Kundel and R L van Metter (Bellingham, WA: SPIE) pp 79-159 (Handbook of Medical Imaging vol 1)
    • (2000) Physics and Psychophysics , pp. 79-159
    • Cunningham, I.A.1
  • 7
    • 33751183741 scopus 로고    scopus 로고
    • DH (Department of Health) 1998 The testing of x-ray image intensifier-television systems Medicines and Healthcare Products Regulatory Agency (MHRA) Report MDA/98/68 (London, SE1 6TQ: MHRA, Department of Health, Hannibal House, Elephant and Castle)
    • (1998)
  • 8
    • 0000658326 scopus 로고    scopus 로고
    • Image quality metrics for digital systems
    • Dobbins J T III 2000 Image quality metrics for digital systems Physics and Psychophysics (Handbook of Medical Imaging vol 1) ed J Beutel, H L Kundel and R L van Metter (Bellingham, WA: SPIE) pp 161-222
    • (2000) Physics and Psychophysics , pp. 161-222
    • Dobbins, J.T.1
  • 10
    • 0036145048 scopus 로고    scopus 로고
    • A comparison of the imaging properties of CCD-based devices used for small field digital mammography
    • Evans D S, Workman A and Payne M 2002 A comparison of the imaging properties of CCD-based devices used for small field digital mammography Phys. Med. Biol. 47 117-35
    • (2002) Phys. Med. Biol. , vol.47 , Issue.1 , pp. 117-135
    • Evans, D.S.1    Workman, A.2    Payne, M.3
  • 11
    • 0021960233 scopus 로고
    • A set of X-ray test objects for quality control in television fluoroscopy
    • Hay G A, Clarke O F, Coleman N J and Cowen A R 1985 A set of X-ray test objects for quality control in television fluoroscopy Br. J. Radiol. 58 335-44
    • (1985) Br. J. Radiol. , vol.58 , Issue.688 , pp. 335-344
    • Hay, G.A.1    Clarke, O.F.2    Coleman, N.J.3    Cowen, A.R.4
  • 12
    • 33751191165 scopus 로고    scopus 로고
    • IEC 62220-1 2003 Medical Electrical Equipment-Characteristics Of Digital X-Ray Imaging Devices:-Part 1. Determination of the Detective Quantum Efficiency (Geneva, Switzerland: International Electrotechnical Commission (IEC))
    • (2003)
  • 13
    • 3042546856 scopus 로고    scopus 로고
    • Measurement of the detective quantum efficiency (DQE) of digital x-ray imaging devices according to the standard IEC 62220-1
    • Illers H, Buhr E, Bergmann D and Hoeschen C 2004 Measurement of the detective quantum efficiency (DQE) of digital x-ray imaging devices according to the standard IEC 62220-1 Physics of Medical Imaging ed M J Yaffe and M J Flynn Proc. SPIE 5368 177-87
    • (2004) Physics of Medical Imaging
    • Illers, H.1    Buhr, E.2    Bergmann, D.3    Hoeschen, C.4
  • 16
    • 0037321550 scopus 로고    scopus 로고
    • Conditioning data for calculation of the modulation transfer function
    • Maidment A D and Albert M 2003 Conditioning data for calculation of the modulation transfer function Med. Phys. 30 248-53
    • (2003) Med. Phys. , vol.30 , Issue.2 , pp. 248-253
    • Maidment, A.D.1    Albert, M.2
  • 18
    • 33646485572 scopus 로고    scopus 로고
    • A comparison between objective and subjective image quality measurements for a full field digital mammography system
    • Marshall N W 2006 A comparison between objective and subjective image quality measurements for a full field digital mammography system Phys. Med. Biol. 51 2441-63
    • (2006) Phys. Med. Biol. , vol.51 , Issue.10 , pp. 2441-2463
    • Marshall, N.W.1
  • 20
    • 33751163711 scopus 로고    scopus 로고
    • NHSBSP (National Health Service Breast Screening Programme)
    • NHSBSP (National Health Service Breast Screening Programme) 2006a Quality Assurance Guidelines for Mammography Including Radiographic Quality Control NHSBSP Publication No. 63 (Sheffield: NHSBSP Publications)
    • (2006) NHSBSP Publication No. 63
  • 22
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • Samei E and Flynn M J 2003 An experimental comparison of detector performance for direct and indirect digital radiography systems Med. Phys. 30 608-22
    • (2003) Med. Phys. , vol.30 , Issue.4 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 23
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • Samei E, Flynn M J and Reimann D A 1998 A method for measuring the presampled MTF of digital radiographic systems using an edge test device Med. Phys. 25 102-13
    • (1998) Med. Phys. , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 24
    • 0032800112 scopus 로고    scopus 로고
    • Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors
    • Stierstorfer K and Spahn M 1999 Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors Med. Phys. 26 1312-9
    • (1999) Med. Phys. , vol.26 , Issue.7 , pp. 1312-1319
    • Stierstorfer, K.1    Spahn, M.2
  • 26
    • 0021848431 scopus 로고
    • Unified SNR analysis of medical imaging systems
    • Wagner R F and Brown D G 1985 Unified SNR analysis of medical imaging systems Phys. Med. Biol. 30 489-518
    • (1985) Phys. Med. Biol. , vol.30 , Issue.6 , pp. 489-518
    • Wagner, R.F.1    Brown, D.G.2
  • 27
    • 0032767557 scopus 로고    scopus 로고
    • Noise power spectra of images from digital mammography detectors
    • Williams M B, Mangiafico P A and Simoni P U 1999 Noise power spectra of images from digital mammography detectors Med. Phys. 26 1279-93
    • (1999) Med. Phys. , vol.26 , Issue.7 , pp. 1279-1293
    • Williams, M.B.1    Mangiafico, P.A.2    Simoni, P.U.3
  • 28
    • 0027738819 scopus 로고
    • Signal, noise and SNR transfer properties of computed radiography
    • Workman A and Cowen A R 1993 Signal, noise and SNR transfer properties of computed radiography Phys. Med. Biol. 38 1789-808
    • (1993) Phys. Med. Biol. , vol.38 , Issue.12 , pp. 1789-1808
    • Workman, A.1    Cowen, A.R.2
  • 29
    • 33644630719 scopus 로고    scopus 로고
    • Quality control for digital mammography: Part II. Recommendations from the ACRIN DMIST trial
    • Yaffe M J et al 2006 Quality control for digital mammography: part II. Recommendations from the ACRIN DMIST trial Med. Phys. 33 737-52
    • (2006) Med. Phys. , vol.33 , Issue.3 , pp. 737-752
    • Yaffe, M.J.1    Al, E.2
  • 30
    • 0036033208 scopus 로고    scopus 로고
    • Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium
    • Yorker J G, Jeromin L S, Lee D L Y, Palecki E F, Golden K P and Jing Z 2002 Characterization of a full field digital mammography detector based on direct x-ray conversion in selenium Physics of Medical Imaging ed L E Antonuk and M J Yaffe Proc. SPIE 4682 21-9
    • (2002) Physics of Medical Imaging
    • Yorker, J.G.1    Jeromin, L.S.2    Lee, D.L.Y.3    Palecki, E.F.4    Golden, K.P.5    Jing, Z.6
  • 31
    • 0037321857 scopus 로고    scopus 로고
    • Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detector
    • Zhao W, Ji W G, Debrie A and Rowlands J A 2003 Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector Med. Phys. 30 254-63
    • (2003) Med. Phys. , vol.30 , Issue.2 , pp. 254-263
    • Zhao, W.1    Ji, W.G.2    Debrie, A.3    Rowlands, J.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.