MRI of patients with cardiac pacemakers: A review of the medical literature

Author keywords

MRI; Pacemaker; Safety

Indexed keywords

ARTIFICIAL HEART PACEMAKER; CLINICAL PROTOCOL; DIAGNOSTIC IMAGING; HUMAN; MORTALITY; NONHUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PACEMAKER; PATIENT MONITORING; PATIENT SAFETY; PEER REVIEW; PRIORITY JOURNAL; RADIOFREQUENCY; REVIEW; RISK ASSESSMENT; RISK BENEFIT ANALYSIS; SYSTEMATIC REVIEW; TEMPERATURE DEPENDENCE;

EID: 79251579035     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.10.4239     Document Type: Review
Times cited : (42)

References (43)
  • 1
    • 37349049968 scopus 로고    scopus 로고
    • Safety of magnetic resonance imaging in patients with cardiovascular devices: An American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: Endorsed by the American College of Cardiology Foundation
    • Levine GN, Gomes AS, Arai AE, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 2007; 116:2878-2891
    • (2007) Circulation , vol.116 , pp. 2878-2891
    • Levine, G.N.1    Gomes, A.S.2    Arai, A.E.3
  • 2
    • 34047272090 scopus 로고    scopus 로고
    • MRI in patients with cardiac devices
    • Martin ET, Sandler DA. MRI in patients with cardiac devices. Curr Cardiol Rep 2007; 9:63-71
    • (2007) Curr Cardiol Rep , vol.9 , pp. 63-71
    • Martin, E.T.1    Sandler, D.A.2
  • 3
    • 4944242415 scopus 로고    scopus 로고
    • Reconsideration of pacemakers and MR imaging
    • Loewy J, Loewy A, Kendall EJ. Reconsideration of pacemakers and MR imaging. RadioGraphics 2004; 24:1257-1267
    • (2004) RadioGraphics , vol.24 , pp. 1257-1267
    • Loewy, J.1    Loewy, A.2    Kendall, E.J.3
  • 4
    • 59649104264 scopus 로고    scopus 로고
    • Researchers seek MRI-safe pacemakers
    • Mitka M. Researchers seek MRI-safe pacemakers. JAMA 2009; 301:476
    • (2009) JAMA , vol.301 , pp. 476
    • Mitka, M.1
  • 5
    • 33748741479 scopus 로고    scopus 로고
    • Food and Drug Administration perspective: Magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients
    • Faris OP, Shein M. Food and Drug Administration perspective: magnetic resonance imaging of pacemaker and implantable cardioverter-defibrillator patients. Circulation 2006; 114:1232-1233
    • (2006) Circulation , vol.114 , pp. 1232-1233
    • Faris, O.P.1    Shein, M.2
  • 6
    • 34249738194 scopus 로고    scopus 로고
    • ACR guidance document for safe MR practices: 2007
    • Kanal E, Barkovich AJ, Bell C, et al. ACR guidance document for safe MR practices: 2007. AJR 2007; 188:1447-1474
    • (2007) AJR , vol.188 , pp. 1447-1474
    • Kanal, E.1    Barkovich, A.J.2    Bell, C.3
  • 7
    • 18044393463 scopus 로고    scopus 로고
    • Current clinical issues of MRI scanning of pacemaker and defibrillator patients
    • Kalin R, Stanton MS. Current clinical issues of MRI scanning of pacemaker and defibrillator patients. Pacing Clin Electrophysiol 2005; 28:326-328
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 326-328
    • Kalin, R.1    Stanton, M.S.2
  • 11
    • 0029045783 scopus 로고
    • Effects of nuclear magnetic resonance imaging on cardiac pacemakers
    • Lauck G, von Smekal A, Wolke S, et al. Effects of nuclear magnetic resonance imaging on cardiac pacemakers. Pacing Clin Electrophysiol 1995; 18:1549-1555
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 1549-1555
    • Lauck, G.1    Von Smekal, A.2    Wolke, S.3
  • 14
    • 33845894695 scopus 로고    scopus 로고
    • Cardiac pacemakers and implantable cardioverter defibrillators: In vitro magnetic resonance imaging evaluation at 1.5-Tesla
    • DOI 10.1080/10976640600897237, PII V83107634342UQT0
    • Shellock FG, Fischer L, Fieno DS. Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla. J Cardiovasc Magn Reson 2007; 9:21-31 (Pubitemid 46018480)
    • (2007) Journal of Cardiovascular Magnetic Resonance , vol.9 , Issue.1 , pp. 21-31
    • Shellock, F.G.1    Fischer, L.2    Fieno, D.S.3
  • 15
    • 58149193750 scopus 로고    scopus 로고
    • Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: Pilot prospective study with 51 examinations
    • Naehle CP, Meyer C, Thomas D, et al. Safety of brain 3-T MR imaging with transmit-receive head coil in patients with cardiac pacemakers: pilot prospective study with 51 examinations. Radiology 2008; 249:991-1001
    • (2008) Radiology , vol.249 , pp. 991-1001
    • Naehle, C.P.1    Meyer, C.2    Thomas, D.3
  • 17
    • 0036800991 scopus 로고    scopus 로고
    • Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields?
    • Luechinger R, Duru F, Zeijlemaker VA, Scheidegger MB, Boesiger P, Candinas R. Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 Tesla magnetic resonance imaging units: are reed switches always closed in strong magnetic fields? Pacing Clin Electrophysiol 2002; 25:1419-1423
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1419-1423
    • Luechinger, R.1    Duru, F.2    Zeijlemaker, V.A.3    Scheidegger, M.B.4    Boesiger, P.5    Candinas, R.6
  • 18
    • 62649135122 scopus 로고    scopus 로고
    • Measuring RF-induced currents inside implants: Impact of device configuration on MRI safety of cardiac pacemaker leads
    • Nordbeck P, Weiss I, Ehses P, et al. Measuring RF-induced currents inside implants: impact of device configuration on MRI safety of cardiac pacemaker leads. Magn Reson Med 2009; 61:570-578
    • (2009) Magn Reson Med , vol.61 , pp. 570-578
    • Nordbeck, P.1    Weiss, I.2    Ehses, P.3
  • 19
    • 53549088320 scopus 로고    scopus 로고
    • In vitro investigation of pacemaker lead heating induced by magnetic resonance imaging: Role of implant geometry
    • Calcagnini G, Triventi M, Censi F, et al. In vitro investigation of pacemaker lead heating induced by magnetic resonance imaging: role of implant geometry. J Magn Reson Imaging 2008; 28:879-886
    • (2008) J Magn Reson Imaging , vol.28 , pp. 879-886
    • Calcagnini, G.1    Triventi, M.2    Censi, F.3
  • 21
    • 0038221323 scopus 로고    scopus 로고
    • Cardiac pacemakers, ICDs, and loop recorder: Evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-Tesla MR systems
    • Shellock FG, Tkach JA, Ruggieri PM, Masaryk TJ. Cardiac pacemakers, ICDs, and loop recorder: evaluation of translational attraction using conventional ("long-bore") and "short-bore" 1.5- and 3.0-Tesla MR systems. J Cardiovasc Magn Reson 2003; 5:387-397
    • (2003) J Cardiovasc Magn Reson , vol.5 , pp. 387-397
    • Shellock, F.G.1    Tkach, J.A.2    Ruggieri, P.M.3    Masaryk, T.J.4
  • 22
    • 39649111737 scopus 로고    scopus 로고
    • Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment
    • Tandri H, Zviman MM, Wedan SR, Lloyd T, Berger RD, Halperin H. Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment. Heart Rhythm 2008; 5:462-468
    • (2008) Heart Rhythm , vol.5 , pp. 462-468
    • Tandri, H.1    Zviman, M.M.2    Wedan, S.R.3    Lloyd, T.4    Berger, R.D.5    Halperin, H.6
  • 24
    • 0023253185 scopus 로고
    • Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers
    • Hayes DL, Holmes DR Jr, Gray JE. Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers. J Am Coll Cardiol 1987; 10:782-786
    • (1987) J Am Coll Cardiol , vol.10 , pp. 782-786
    • Hayes, D.L.1    Holmes Jr., D.R.2    Gray, J.E.3
  • 25
    • 0021167926 scopus 로고
    • The effects of nuclear magnetic resonance imagers on external and implantable pulse generators
    • Fetter J, Aram G, Holmes DR Jr, Gray JE, Hayes DL. The effects of nuclear magnetic resonance imagers on external and implantable pulse generators. Pacing Clin Electrophysiol 1984; 7:720-727
    • (1984) Pacing Clin Electrophysiol , vol.7 , pp. 720-727
    • Fetter, J.1    Aram, G.2    Holmes Jr., D.R.3    Gray, J.E.4    Hayes, D.L.5
  • 26
    • 59149092325 scopus 로고    scopus 로고
    • Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: Clinical study design
    • Sutton R, Kanal E, Wilkoff BL, et al. Safety of magnetic resonance imaging of patients with a new Medtronic EnRhythm MRI SureScan pacing system: clinical study design. Trials 2008; 9:68
    • (2008) Trials , vol.9 , pp. 68
    • Sutton, R.1    Kanal, E.2    Wilkoff, B.L.3
  • 27
    • 59049103664 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with implantable cardiac devices
    • Sierra M, Machado C. Magnetic resonance imaging in patients with implantable cardiac devices. Rev Cardiovasc Med 2008; 9:232-238
    • (2008) Rev Cardiovasc Med , vol.9 , pp. 232-238
    • Sierra, M.1    Machado, C.2
  • 28
    • 33845903056 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance at 0.5T in five patients with permanent pacemakers
    • Heatlie G, Pennell DJ. Cardiovascular magnetic resonance at 0.5T in five patients with permanent pacemakers. J Cardiovasc Magn Reson 2007; 9:15-19
    • (2007) J Cardiovasc Magn Reson , vol.9 , pp. 15-19
    • Heatlie, G.1    Pennell, D.J.2
  • 29
    • 0035030124 scopus 로고    scopus 로고
    • Interference with cardiac pacemakers by magnetic resonance imaging: Are there irreversible changes at 0.5 Tesla?
    • Vahlhaus C, Sommer T, Lewalter T, et al. Interference with cardiac pacemakers by magnetic resonance imaging: are there irreversible changes at 0.5 Tesla? Pacing Clin Electrophysiol 2001; 24:489-495
    • (2001) Pacing Clin Electrophysiol , vol.24 , pp. 489-495
    • Vahlhaus, C.1    Sommer, T.2    Lewalter, T.3
  • 31
    • 33748752144 scopus 로고    scopus 로고
    • Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: A prospective study with 115 examinations
    • Sommer T, Naehle CP, Yang A, et al. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations. Circulation 2006; 114:1285-1292
    • (2006) Circulation , vol.114 , pp. 1285-1292
    • Sommer, T.1    Naehle, C.P.2    Yang, A.3
  • 33
    • 33748740922 scopus 로고    scopus 로고
    • Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla
    • DOI 10.1161/CIRCULATIONAHA.105.607655, PII 0000301720060919000011
    • Nazarian S, Roguin A, Zviman MM, et al. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla. Circulation 2006; 114:1277-1284 (Pubitemid 44402053)
    • (2006) Circulation , vol.114 , Issue.12 , pp. 1277-1284
    • Nazarian, S.1    Roguin, A.2    Zviman, M.M.3    Lardo, A.C.4    Dickfeld, T.L.5    Calkins, H.6    Weiss, R.G.7    Berger, R.D.8    Bluemke, D.A.9    Halperin, H.R.10
  • 34
    • 0029969886 scopus 로고    scopus 로고
    • Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
    • DOI 10.1111/j.1540-8159.1996.tb03387.x
    • Gimbel JR, Johnson D, Levine PA, Wilkoff BL. Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. Pacing Clin Electrophysiol 1996; 19:913-919 (Pubitemid 26176166)
    • (1996) PACE - Pacing and Clinical Electrophysiology , vol.19 , Issue.6 , pp. 913-919
    • Gimbel, J.R.1    Johnson, D.2    Levine, P.A.3    Wilkoff, B.L.4
  • 35
    • 55249119369 scopus 로고    scopus 로고
    • Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla
    • Gimbel JR. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla. Pacing Clin Electrophysiol 2008; 31:795-801
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 795-801
    • Gimbel, J.R.1
  • 37
    • 51849086439 scopus 로고    scopus 로고
    • Cardiac biomarkers in patients with permanent pacemakers and implantable cardioverter-defibrillators undergoing an MRI scan
    • Mollerus M, Albin G, Lipinski M, Lucca J. Cardiac biomarkers in patients with permanent pacemakers and implantable cardioverter-defibrillators undergoing an MRI scan. Pacing Clin Electrophysiol 2008; 31:1241-1245
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 1241-1245
    • Mollerus, M.1    Albin, G.2    Lipinski, M.3    Lucca, J.4
  • 39
    • 20344387680 scopus 로고    scopus 로고
    • Do we need pacemakers resistant to magnetic resonance imaging?
    • DOI 10.1016/j.eupc.2005.02.120, PII S1099512905001704
    • Irnich W, Irnich B, Bartsch C, Stertmann WA, Gufler H, Weiler G. Do we need pacemakers resistant to magnetic resonance imaging? Europace 2005; 7:353-365 (Pubitemid 40790421)
    • (2005) Europace , vol.7 , Issue.4 , pp. 353-365
    • Irnich, W.1    Irnich, B.2    Bartsch, C.3    Stertmann, W.A.4    Gufler, H.5    Weiler, G.6
  • 40
    • 0024060859 scopus 로고
    • Loss prevention case of the month: Not my responsibility!
    • Avery JK. Loss prevention case of the month: not my responsibility! J Tenn Med Assoc 1988; 81:523
    • (1988) J Tenn Med Assoc , vol.81 , pp. 523
    • Avery, J.K.1
  • 41
    • 3242785606 scopus 로고    scopus 로고
    • Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating
    • Baker KB, Tkach JA, Nyenhuis JA, et al. Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating. J Magn Reson Imaging 2004; 20:315-320
    • (2004) J Magn Reson Imaging , vol.20 , pp. 315-320
    • Baker, K.B.1    Tkach, J.A.2    Nyenhuis, J.A.3
  • 42
    • 34247534258 scopus 로고    scopus 로고
    • Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic probes
    • DOI 10.1088/0031-9155/52/6/006, PII S0031915507334039, 006
    • Mattei E, Triventi M, Calcagnini G, et al. Temperature and SAR measurement errors in the evaluation of metallic linear structures heating during MRI using fluoroptic probes. Phys Med Biol 2007; 52:1633-1646 (Pubitemid 46646371)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.6 , pp. 1633-1646
    • Mattei, E.1    Triventi, M.2    Calcagnini, G.3    Censi, F.4    Kainz, W.5    Bassen, H.I.6    Bartolini, P.7
  • 43
    • 0036288276 scopus 로고    scopus 로고
    • Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead
    • Greatbatch W, Miller V, Shellock FG. Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead. J Magn Reson Imaging 2002; 16:97-103
    • (2002) J Magn Reson Imaging , vol.16 , pp. 97-103
    • Greatbatch, W.1    Miller, V.2    Shellock, F.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.