Volumn 9, Issue 1, 2007, Pages 15-19

Cardiovascular magnetic resonance at 0.5T in five patients with permanent pacemakers

Author keywords

Heart; Magnetic Resonance; Pacemaker; Safety

Indexed keywords

ARTICLE; ARTIFACT; ARTIFICIAL HEART PACEMAKER; CARDIOLOGIST; CARDIOVASCULAR SYSTEM; CARDIOVASCULAR SYSTEM EXAMINATION; CLINICAL ARTICLE; CONGESTIVE CARDIOMYOPATHY; DIAGNOSTIC IMAGING; ELECTROCARDIOGRAM; ELECTROCARDIOGRAPHY; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RISK ASSESSMENT; SARCOIDOSIS; SINUS NODE;

EID: 33845903056     PISSN: 10976647     EISSN: 1532429X     Source Type: Journal    
DOI: 10.1080/10976640600897260     Document Type: Article
Times cited : (16)

References (21)
  • 1
    • 4143152698 scopus 로고    scopus 로고
    • MR procedures: Biologic effects, safety, and patient care
    • Shellock FG, Crues JV. MR procedures: biologic effects, safety, and patient care. Radiology 2004;232:635-52.
    • (2004) Radiology , vol.232 , pp. 635-652
    • Shellock, F.G.1    Crues, J.V.2
  • 2
    • 0024060859 scopus 로고
    • Loss prevention case of the month: Notmy responsibility!
    • Avery JE. Loss prevention case of the month: notmy responsibility! J Tenn Med Assoc 1988;81:523.
    • (1988) J Tenn Med Assoc , vol.81 , pp. 523
    • Avery, J.E.1
  • 3
    • 33845910433 scopus 로고    scopus 로고
    • Food and Drug Administration, Health MR Product Reporting Program. Available at
    • Food and Drug Administration. Center for Devices and Radiological Health MR Product Reporting Program. Available at: http://www.fda.gov/cdrh/mdr
    • Center for Devices and Radiological
  • 6
    • 0034077462 scopus 로고    scopus 로고
    • MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T
    • Sommer T, Vahlhaus C, Lauck G, Von Smekal A, Reinke M, Hofer U, et al. MR imaging and cardiac pacemakers: in vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 2000;215:869-79.
    • (2000) Radiology , vol.215 , pp. 869-879
    • Sommer, T.1    Vahlhaus, C.2    Lauck, G.3    Von Smekal, A.4    Reinke, M.5    Hofer, U.6
  • 7
    • 1842478179 scopus 로고    scopus 로고
    • Magnetic resonance imaging and cardiac pacemaker safety at 1.5 Tesla
    • Martin E, Coman J, Shellock F. Magnetic resonance imaging and cardiac pacemaker safety at 1.5 Tesla. J Am Coll Cardiol 2004;43:315-24.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 315-324
    • Martin, E.1    Coman, J.2    Shellock, F.3
  • 8
    • 0029969886 scopus 로고    scopus 로고
    • Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
    • Gimbel JR, Johnson D, Levine PA, Wilkoff BL. Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. Pacing Clin Electrophysiol 1996;19:913-9.
    • (1996) Pacing Clin Electrophysiol , vol.19 , pp. 913-919
    • Gimbel, J.R.1    Johnson, D.2    Levine, P.A.3    Wilkoff, B.L.4
  • 10
    • 0027475037 scopus 로고
    • Case report: Nuclear magnetic resonance imaging in a patient with a pacemaker
    • Inbar S, Larson J, Burt T, Mafee M, Ezri M. Case report: nuclear magnetic resonance imaging in a patient with a pacemaker. Am J Med Sci 1993;3:174-5.
    • (1993) Am J Med Sci , vol.3 , pp. 174-175
    • Inbar, S.1    Larson, J.2    Burt, T.3    Mafee, M.4    Ezri, M.5
  • 11
    • 0342557951 scopus 로고
    • Nuclear magnetic resonance imaging of a patient with implanted transvenous pacemaker
    • Iberer F, Justich E, Stenzl W, Tscheliessnig KH, Kapeller J. Nuclear magnetic resonance imaging of a patient with implanted transvenous pacemaker. Herz 1987;7:196-9.
    • (1987) Herz , vol.7 , pp. 196-199
    • Iberer, F.1    Justich, E.2    Stenzl, W.3    Tscheliessnig, K.H.4    Kapeller, J.5
  • 17
    • 0032929257 scopus 로고    scopus 로고
    • Cardiac pacemakers and implantable cardioverter defibrillators are unaffected by operation of extremity MR imaging system
    • Shellock FG, O'Neil M, Ivans V, et al. Cardiac pacemakers and implantable cardioverter defibrillators are unaffected by operation of extremity MR imaging system. Am J Roentgenol 1999;172:165-70.
    • (1999) Am J Roentgenol , vol.172 , pp. 165-170
    • Shellock, F.G.1    O'Neil, M.2    Ivans, V.3
  • 20
    • 4944242415 scopus 로고    scopus 로고
    • Reconsideration of pacemakers and MR imaging
    • Loewy J, Loewy A, Kendall EJ. Reconsideration of pacemakers and MR imaging. Radiographics 2004;24:1257-68.
    • (2004) Radiographics , vol.24 , pp. 1257-1268
    • Loewy, J.1    Loewy, A.2    Kendall, E.J.3
  • 21
    • 1842521463 scopus 로고    scopus 로고
    • Strategies for the safe performance of magnetic resonance imaging in selected pacemaker patients (abstr)
    • Juratli N, Sparker J, Gimbel JR, Wilkoff B. Strategies for the safe performance of magnetic resonance imaging in selected pacemaker patients (abstr). Circulation 2001;104 Suppl II:638-9.
    • (2001) Circulation , vol.104 , Issue.SUPPL. II , pp. 638-639
    • Juratli, N.1    Sparker, J.2    Gimbel, J.R.3    Wilkoff, B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.