Pacemaker reed switch behavior in 0.5, 1.5, and 3.0 tesla magnetic resonance imaging units: Are reed switches always closed in strong magnetic fields?

Author keywords

Magnetic resonance; MRI; Pacemaker; Reed switch

Indexed keywords

ARTICLE; ARTIFICIAL HEART PACEMAKER; DEFIBRILLATOR; HEART VENTRICLE PACING; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE IMAGING; TREATMENT CONTRAINDICATION;

EID: 0036800991     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2002.01419.x     Document Type: Article
Times cited : (94)

References (10)
  • 1
    • 0026834428 scopus 로고
    • Smri Report Policies, guidelines and recommendations for MR imaging safety and patient management
    • Shellock FG, Kanal E. SMRI Report: Policies, guidelines and recommendations for MR imaging safety and patient management. J Magn Reson Imaging 1992; 2: 247-248.
    • (1992) J Magn Reson Imaging , vol.2 , pp. 247-248
    • Shellock, F.G.1    Kanal, E.2
  • 2
    • 0030931926 scopus 로고    scopus 로고
    • Effects of magnetic resonance imaging on cardiac pacemakers and electrodes
    • Achenbach S, Moshage W, Diem B, et al. Effects of magnetic resonance imaging on cardiac pacemakers and electrodes. Am Heart J 1997; 134: 467-473.
    • (1997) Am Heart J , vol.134 , pp. 467-473
    • Achenbach, S.1    Moshage, W.2    Diem, B.3
  • 3
    • 0031839080 scopus 로고    scopus 로고
    • Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging
    • Fontaine JM, Mohamed FB, Gottlieb C, et al. Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging. PACE 1998; 21: 1336-1339.
    • (1998) PACE , vol.21 , pp. 1336-1339
    • Fontaine, J.M.1    Mohamed, F.B.2    Gottlieb, C.3
  • 4
    • 0028349660 scopus 로고
    • Safety and magnetic resonance imaging
    • Mosely I. Safety and magnetic resonance imaging. Br Med J 1994; 208: 1181-1182.
    • (1994) Br Med J , vol.208 , pp. 1181-1182
    • Mosely, I.1
  • 5
    • 0021321818 scopus 로고
    • Artifacts and hazards in NMR imaging due to metal implants and cardiac pacemakers
    • Zimmermann BH. Artifacts and hazards in NMR imaging due to metal implants and cardiac pacemakers. Diagn Imag Clin Med 1984; 53: 53-56.
    • (1984) Diagn Imag Clin Med , vol.53 , pp. 53-56
    • Zimmermann, B.H.1
  • 6
    • 0020638735 scopus 로고
    • The effects of nuclear magnetic resonance on patients with cardiac pacemakers
    • Pavlicek W, Geisinger M, Castle L, et al. The effects of nuclear magnetic resonance on patients with cardiac pacemakers. Radiology 1983; 147: 149-153.
    • (1983) Radiology , vol.147 , pp. 149-153
    • Pavlicek, W.1    Geisinger, M.2    Castle, L.3
  • 7
    • 0034942717 scopus 로고    scopus 로고
    • Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility
    • Duru F, Luechinger R, Scheidegger MB, et al. Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility. Eur Heart J 2001; 22: 113-124.
    • (2001) Eur Heart J , vol.22 , pp. 113-124
    • Duru, F.1    Luechinger, R.2    Scheidegger, M.B.3
  • 8
    • 0029969886 scopus 로고    scopus 로고
    • Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers
    • Gimbel R, Johnson D, Levine P, et al. Safe performance of magnetic resonance imaging on five patients with permanent cardiac pacemakers. PACE 1996; 19: 913-919.
    • (1996) PACE , vol.19 , pp. 913-919
    • Gimbel, R.1    Johnson, D.2    Levine, P.3
  • 9
    • 0034077462 scopus 로고    scopus 로고
    • MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T
    • Sommer T, Vahlhaus C, Lauck G, et al. MR imaging and cardiac pacemakers: In vitro evaluation and in vivo studies in 51 patients at 0.5 T. Radiology 2000; 215: 869-879.
    • (2000) Radiology , vol.215 , pp. 869-879
    • Sommer, T.1    Vahlhaus, C.2    Lauck, G.3
  • 10
    • 0035098415 scopus 로고    scopus 로고
    • Force and torque effects of a 1.5 T magnetic resonance imaging scanner on cardiac pacemakers and implantable cardioverter-defibrillators
    • Luechinger R, Duru F, Scheidegger MB, et al. Force and torque effects of a 1.5 T magnetic resonance imaging scanner on cardiac pacemakers and implantable cardioverter-defibrillators. PACE 2001; 24: 199-205.
    • (2001) PACE , vol.24 , pp. 199-205
    • Luechinger, R.1    Duru, F.2    Scheidegger, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.