메뉴 건너뛰기




Volumn 107, Issue 3, 2011, Pages 374-382

Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in predrug-eluting stent era

Author keywords

[No Author keywords available]

Indexed keywords

ADVERSE OUTCOME; ANGIOCARDIOGRAPHY; ARTICLE; BARE METAL STENT; BLOOD VESSEL DIAMETER; CORONARY ARTERY RECANALIZATION; CORONARY STENT; DRUG ELUTING STENT; FOLLOW UP; HEART INFARCTION; HUMAN; INTRAVASCULAR ULTRASOUND; META ANALYSIS; MORTALITY; MULTICENTER STUDY (TOPIC); NON ST SEGMENT ELEVATION MYOCARDIAL INFARCTION; PEER REVIEW; PERCUTANEOUS CORONARY INTERVENTION; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL (TOPIC); RESTENOSIS; SENSITIVITY ANALYSIS; ST SEGMENT ELEVATION MYOCARDIAL INFARCTION;

EID: 78951469778     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2010.09.030     Document Type: Article
Times cited : (166)

References (29)
  • 3
    • 0037678479 scopus 로고    scopus 로고
    • Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: A meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting
    • G. Cassella, V. Klauss, F. Ottani, U. Siebert, P. Sangiorgio, and D. Bracchetti Impact of intravascular ultrasound-guided stenting on long-term clinical outcome: a meta-analysis of available studies comparing intravascular ultrasound-guided and angiographically guided stenting Catheter Cardiovasc Interv 59 2003 314 321
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 314-321
    • Cassella, G.1    Klauss, V.2    Ottani, F.3    Siebert, U.4    Sangiorgio, P.5    Bracchetti, D.6
  • 4
    • 34548765043 scopus 로고    scopus 로고
    • Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound: The multicenter, randomized trial results
    • Investigators of Direct Stenting vs Optimal Angioplasty Trial (DIPOL) J.
    • R.J. Gil, T. Pawowski, D. Dudek, G. Horszczaruk, K. Zmudka, M. Lesiak, A. Witkowski, A. Ochaa, J. Kubica Investigators of Direct Stenting vs Optimal Angioplasty Trial (DIPOL) Comparison of angiographically guided direct stenting technique with direct stenting and optimal balloon angioplasty guided with intravascular ultrasound: the multicenter, randomized trial results Am Heart J 154 2007 669 675
    • (2007) Am Heart J , vol.154 , pp. 669-675
    • Gil, R.J.1    Pawowski, T.2    Dudek, D.3    Horszczaruk, G.4    Zmudka, K.5    Lesiak, M.6    Witkowski, A.7    Ochaa, A.8    Kubica9
  • 6
    • 0035011852 scopus 로고    scopus 로고
    • Cost-effectiveness analysis of intravascular ultrasound guided percutaneous coronary intervention versus conventional percutaneous coronary intervention
    • A.L. Gaster, U. Slothuus, J. Larsen, P. Thayssen, and T. Haghfelt Cost-effectiveness analysis of intravascular ultrasound guided percutaneous coronary intervention versus conventional percutaneous coronary intervention Scand Cardiovasc J 35 2001 80 85
    • (2001) Scand Cardiovasc J , vol.35 , pp. 80-85
    • Gaster, A.L.1    Slothuus, U.2    Larsen, J.3    Thayssen, P.4    Haghfelt, T.5
  • 7
    • 0042829397 scopus 로고    scopus 로고
    • Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: Insights from a prospective, randomised study
    • A.L. Gaster, U. Slothuus Skjoldborg, J. Larsen, L. Korsholm, C. von Birgelen, S. Jensen, P. Thayssen, K.E. Pedersen, and T.H. Haghfelt Continued improvement of clinical outcome and cost effectiveness following intravascular ultrasound guided PCI: insights from a prospective, randomised study Heart 89 2003 1043 1049
    • (2003) Heart , vol.89 , pp. 1043-1049
    • Gaster, A.L.1    Slothuus Skjoldborg, U.2    Larsen, J.3    Korsholm, L.4    Von Birgelen, C.5    Jensen, S.6    Thayssen, P.7    Pedersen, K.E.8    Haghfelt, T.H.9
  • 8
    • 0032145711 scopus 로고    scopus 로고
    • Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: A multicenter, randomized study comparing two strategieswith and without intravascular ultrasound guidance
    • F. Schiele, N. Meneveau, A. Vuillemenot, D.D. Zhang, S. Gupta, M. Mercier, N. Danchin, B. Bertrand, and J.P. Bassand Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategieswith and without intravascular ultrasound guidance J Am Coll Cardiol 32 1998 320 328
    • (1998) J Am Coll Cardiol , vol.32 , pp. 320-328
    • Schiele, F.1    Meneveau, N.2    Vuillemenot, A.3    Zhang, D.D.4    Gupta, S.5    Mercier, M.6    Danchin, N.7    Bertrand, B.8    Bassand, J.P.9
  • 9
    • 0034508354 scopus 로고    scopus 로고
    • Medical costs of intravascular ultrasound optimization of stent deployment: Results of the multicenter randomized "rEStenosis after Intravascular ultrasound Stenting" (RESIST) study
    • F. Schiele, N. Meneveau, M.F. Seronde, F. Caulfield, B. Pisa, P. Arveux, B. Bertrand, N. Danchin, and J.P. Bassand Medical costs of intravascular ultrasound optimization of stent deployment Results of the multicenter randomized "REStenosis after Intravascular ultrasound Stenting" (RESIST) study Int J Cardiovasc Interv 3 2000 207 213
    • (2000) Int J Cardiovasc Interv , vol.3 , pp. 207-213
    • Schiele, F.1    Meneveau, N.2    Seronde, M.F.3    Caulfield, F.4    Pisa, B.5    Arveux, P.6    Bertrand, B.7    Danchin, N.8    Bassand, J.P.9
  • 10
    • 0037422555 scopus 로고    scopus 로고
    • Thrombocyte activity evaluation and effects of Ultrasound guidance in Long Intracoronary stent placement: Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: Final results of a randomized comparison with angiographic guidance (TULIP Study)
    • TULIP Study E.E.
    • P.V. Oemrawsingh, G.S. Mintz, M.J. Schalij, A.H. Zwinderman, J.W. Jukema, E.E. van der Wall TULIP Study Thrombocyte activity evaluation and effects of Ultrasound guidance in Long Intracoronary stent placement: intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study) Circulation 107 2003 62 67
    • (2003) Circulation , vol.107 , pp. 62-67
    • Oemrawsingh, P.V.1    Mintz, G.S.2    Schalij, M.J.3    Zwinderman, A.H.4    Jukema, J.W.5    Van Der Wall6
  • 11
    • 0035908974 scopus 로고    scopus 로고
    • Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study)
    • OPTICUS (OPTimization with ICUS to reduce stent restenosis) Study Investigators A.
    • H. Mudra, C. di Mario, P. de Jaegere, H.R. Figulla, C. Macaya, R. Zahn, B. Wennerblom, W. Rutsch, V. Voudris, E. Regar, K.H. Henneke, V. Schchinger, A. Zeiher OPTICUS (OPTimization with ICUS to reduce stent restenosis) Study Investigators Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study) Circulation 104 2001 1343 1349
    • (2001) Circulation , vol.104 , pp. 1343-1349
    • Mudra, H.1    Di Mario, C.2    De Jaegere, P.3    Figulla, H.R.4    MacAya, C.5    Zahn, R.6    Wennerblom, B.7    Rutsch, W.8    Voudris, V.9    Regar, E.10    Henneke, K.H.11    Schchinger, V.12    Zeiher13
  • 12
    • 0034649313 scopus 로고    scopus 로고
    • Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: Results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial
    • A.W. Frey, J.M. Hodgson, C. Mller, H.P. Bestehorn, and H. Roskamm Ultrasound-guided strategy for provisional stenting with focal balloon combination catheter: results from the randomized Strategy for Intracoronary Ultrasound-guided PTCA and Stenting (SIPS) trial Circulation 102 2000 2497 2502
    • (2000) Circulation , vol.102 , pp. 2497-2502
    • Frey, A.W.1    Hodgson, J.M.2    Mller, C.3    Bestehorn, H.P.4    Roskamm, H.5
  • 13
    • 0037417937 scopus 로고    scopus 로고
    • Intravascular ultrasound-guided balloon angioplasty compared with stent: Immediate and 6-month results of the multicenter, randomized Balloon Equivalent to Stent Study (BEST)
    • Balloon Equivalent to Stent study J.P.
    • F. Schiele, N. Meneveau, M. Gilard, J. Boschat, P. Commeau, L.P. Ming, P. Sewoke, M.F. Seronde, M. Mercier, S. Gupta, J.P. Bassand Balloon Equivalent to Stent study Intravascular ultrasound-guided balloon angioplasty compared with stent: immediate and 6-month results of the multicenter, randomized Balloon Equivalent to Stent Study (BEST) Circulation 107 2003 545 551
    • (2003) Circulation , vol.107 , pp. 545-551
    • Schiele, F.1    Meneveau, N.2    Gilard, M.3    Boschat, J.4    Commeau, P.5    Ming, L.P.6    Sewoke, P.7    Seronde, M.F.8    Mercier, M.9    Gupta, S.10    Bassand11
  • 14
    • 0028659004 scopus 로고
    • Operating characteristics of a rank correlation test for publication bias
    • C.B. Begg, and M. Mazumdar Operating characteristics of a rank correlation test for publication bias Biometrics 50 1994 1088 1101
    • (1994) Biometrics , vol.50 , pp. 1088-1101
    • Begg, C.B.1    Mazumdar, M.2
  • 15
    • 0032753758 scopus 로고    scopus 로고
    • Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography
    • P.J. de Feyter, P. Kay, C. Disco, and P.W. Serruys Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography Circulation 100 1999 1777 1783
    • (1999) Circulation , vol.100 , pp. 1777-1783
    • De Feyter, P.J.1    Kay, P.2    Disco, C.3    Serruys, P.W.4
  • 21
    • 2542445152 scopus 로고    scopus 로고
    • Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: Serial intravascular ultrasound analysis from the SIRIUS trial
    • SIRIUS Investigators P.J.
    • S. Sonoda, Y. Morino, J. Ako, M. Terashima, A.H. Hassan, H.N. Bonneau, M.B. Leon, J.W. Moses, P.G. Yock, Y. Honda, R.E. Kuntz, P.J. Fitzgerald SIRIUS Investigators Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the SIRIUS trial J Am Coll Cardiol 43 2004 1959 1963
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1959-1963
    • Sonoda, S.1    Morino, Y.2    Ako, J.3    Terashima, M.4    Hassan, A.H.5    Bonneau, H.N.6    Leon, M.B.7    Moses, J.W.8    Yock, P.G.9    Honda, Y.10    Kuntz, R.E.11    Fitzgerald12
  • 23
    • 72149093190 scopus 로고    scopus 로고
    • Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: An integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials
    • H. Doi, A. Maehara, G.S. Mintz, A. Yu, H. Wang, L. Mandinov, J.J. Popma, S.G. Ellis, E. Grube, K.D. Dawkins, N.J. Weissman, M.A. Turco, J.A. Ormiston, and G.W. Stone Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials J Am Coll Cardiol Interv 2 2009 1269 1275
    • (2009) J Am Coll Cardiol Interv , vol.2 , pp. 1269-1275
    • Doi, H.1    Maehara, A.2    Mintz, G.S.3    Yu, A.4    Wang, H.5    Mandinov, L.6    Popma, J.J.7    Ellis, S.G.8    Grube, E.9    Dawkins, K.D.10    Weissman, N.J.11    Turco, M.A.12    Ormiston, J.A.13    Stone, G.W.14
  • 24
    • 72149085728 scopus 로고    scopus 로고
    • Stent expansion as a mechanical parameter to predict late stent patency: Back to the basics
    • Y. Honda, and P.J. Fitzgerald Stent expansion as a mechanical parameter to predict late stent patency: back to the basics J Am Coll Cardiol Interv 2 2009 12761128
    • (2009) J Am Coll Cardiol Interv , vol.2
    • Honda, Y.1    Fitzgerald, P.J.2
  • 27
    • 69049095006 scopus 로고    scopus 로고
    • Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis
    • MAIN-COMPARE Investigators S.W.
    • S.J. Park, Y.H. Kim, D.W. Park, S.W. Lee, W.J. Kim, J. Suh, S.C. Yun, C.W. Lee, M.K. Hong, J.H. Lee, S.W. Park MAIN-COMPARE Investigators Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis Circ Cardiovasc Interv 2 2009 167 177
    • (2009) Circ Cardiovasc Interv , vol.2 , pp. 167-177
    • Park, S.J.1    Kim, Y.H.2    Park, D.W.3    Lee, S.W.4    Kim, W.J.5    Suh, J.6    Yun, S.C.7    Lee, C.W.8    Hong, M.K.9    Lee, J.H.10    Park11


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.