메뉴 건너뛰기




Volumn 32, Issue 2, 1998, Pages 320-328

Impact of intravascular ultrasound guidance in stent deployment on 6- month restenosis rate: A multicenter, randomized study comparing two strategies - With and without intravascular ultrasound guidance

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; HEART CATHETERIZATION; HEART INFARCTION; HUMAN; INTRAVASCULAR ULTRASOUND; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RECURRENCE RISK; RESTENOSIS; RISK ASSESSMENT; STENT; TREATMENT OUTCOME; ULTRASOUND TRANSDUCER;

EID: 0032145711     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0735-1097(98)00249-6     Document Type: Article
Times cited : (215)

References (23)
  • 1
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary heart disease
    • for the BENESTENT Study Group
    • Serruys P, De Jaegere P, Kiemenij F, et al., for the BENESTENT Study Group. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary heart disease. N Engl J Med 1994;331:489-95.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.1    De Jaegere, P.2    Kiemenij, F.3
  • 2
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in treatment of coronary artery disease (STRESS trial)
    • Fischman D.L., Leon M.B., Baim D.S., et al. A randomized comparison of coronary-stent placement and balloon angioplasty in treatment of coronary artery disease (STRESS trial). N Engl J Med. 331:1994;496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 3
    • 0030046251 scopus 로고    scopus 로고
    • Continued benefit of coronary stenting versus balloon angioplasty: One-year clinical follow-up of BENESTENT trial
    • Macaya C., Serruys P.W., Ruygrok P., et al. Continued benefit of coronary stenting versus balloon angioplasty one-year clinical follow-up of BENESTENT trial . J Am Coll Cardiol. 27:1996;255-261.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 255-261
    • MacAya, C.1    Serruys, P.W.2    Ruygrok, P.3
  • 4
    • 0028345876 scopus 로고
    • Intracoronary ultrasound observations during stent implantation
    • Nakamura S., Colombo A., Gaglione A., et al. Intracoronary ultrasound observations during stent implantation. Circulation. 89:1994;2026-2034.
    • (1994) Circulation , vol.89 , pp. 2026-2034
    • Nakamura, S.1    Colombo, A.2    Gaglione, A.3
  • 5
    • 0028106302 scopus 로고
    • Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter
    • Mudra H., Klauss V., Blasini R., et al. Ultrasound guidance of Palmaz-Schatz intracoronary stenting with a combined intravascular ultrasound balloon catheter. Circulation. 90:1994;1252-1261.
    • (1994) Circulation , vol.90 , pp. 1252-1261
    • Mudra, H.1    Klauss, V.2    Blasini, R.3
  • 6
    • 0029143048 scopus 로고
    • Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation
    • Gorge G., Haude M., Ge J., et al. Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation. J Am Coll Cardiol. 26:1995;725-730.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 725-730
    • Gorge, G.1    Haude, M.2    Ge, J.3
  • 8
    • 0028912131 scopus 로고
    • Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance
    • Colombo A., Hall P., Nakamura S., et al. Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance. Circulation. 91:1995;1676-1688.
    • (1995) Circulation , vol.91 , pp. 1676-1688
    • Colombo, A.1    Hall, P.2    Nakamura, S.3
  • 9
    • 0030070652 scopus 로고    scopus 로고
    • A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravascular ultrasound guided stent implantation
    • Hall P., Nakamura S., Maiello L., et al. A randomized comparison of combined ticlopidine and aspirin therapy versus aspirin therapy alone after successful intravascular ultrasound guided stent implantation. Circulation. 93:1996;215-222.
    • (1996) Circulation , vol.93 , pp. 215-222
    • Hall, P.1    Nakamura, S.2    Maiello, L.3
  • 10
    • 10144234792 scopus 로고    scopus 로고
    • Intracoronary stent implantation without ultrasound guidance and with replacement of conventionnal anticoagulation by antiplatelet therapy: 30 day clinical outcome of the French multicenter registry
    • Karillon G.J., Morice M.C., Benveniste E., et al. Intracoronary stent implantation without ultrasound guidance and with replacement of conventionnal anticoagulation by antiplatelet therapy 30 day clinical outcome of the French multicenter registry . Circulation. 94:1996;1519-1527.
    • (1996) Circulation , vol.94 , pp. 1519-1527
    • Karillon, G.J.1    Morice, M.C.2    Benveniste, E.3
  • 11
    • 9244251971 scopus 로고    scopus 로고
    • A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary artery stents
    • Schomig A., Neumann F.J., Kastrati A., et al. A randomized comparison of antiplatelet and anticoagulant therapy after the placement of coronary artery stents. N Engl J Med. 334:1996;1084-1089.
    • (1996) N Engl J Med , vol.334 , pp. 1084-1089
    • Schomig, A.1    Neumann, F.J.2    Kastrati, A.3
  • 12
    • 0031909566 scopus 로고    scopus 로고
    • Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents
    • Hoffmann R., Mintz G.S., Mehran R., et al. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents. J Am Coll Cardiol. 31:1998;43-49.
    • (1998) J Am Coll Cardiol , vol.31 , pp. 43-49
    • Hoffmann, R.1    Mintz, G.S.2    Mehran, R.3
  • 13
    • 0001065462 scopus 로고    scopus 로고
    • The predictive value of different intravascular ultrasound criteria for restenosis after coronary stenting [abstract]
    • Moussa I., Di Mario C., Moses J., Reimers B., Blengino S., Colombo A. The predictive value of different intravascular ultrasound criteria for restenosis after coronary stenting [abstract]. J Am Coll Cardiol. 29:(Suppl A):1997;60A.
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Moussa, I.1    Di Mario, C.2    Moses, J.3    Reimers, B.4    Blengino, S.5    Colombo, A.6
  • 14
    • 0010498517 scopus 로고    scopus 로고
    • Does optimal stent expansion on intravascular ultrasound predict freedom from restenosis? [abstract]
    • Akiyama T., Goldberg S., Di Mario C., Reimers B., Blengino S., Colombo A. Does optimal stent expansion on intravascular ultrasound predict freedom from restenosis? [abstract]. Eur Heart J. 18:(Suppl):1997;384.
    • (1997) Eur Heart J , vol.18 , Issue.SUPPL , pp. 384
    • Akiyama, T.1    Goldberg, S.2    Di Mario, C.3    Reimers, B.4    Blengino, S.5    Colombo, A.6
  • 15
    • 0001026531 scopus 로고    scopus 로고
    • Predictors of target vessel revascularization following coronary stent deployment [abstract]
    • Ziada K.M., Kim M.H., Potts W., et al. Predictors of target vessel revascularization following coronary stent deployment [abstract]. J Am Coll Cardiol. 29:(Suppl A):1997;239A.
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Ziada, K.M.1    Kim, M.H.2    Potts, W.3
  • 16
    • 0029837889 scopus 로고    scopus 로고
    • Patterns and mechanisms of in-stent restenosis: A serial intravascular ultrasound study
    • Hoffman R., Mintz G.S., Dussaillant G.R., et al. Patterns and mechanisms of in-stent restenosis a serial intravascular ultrasound study . Circulation. 94:1996;1247-1254.
    • (1996) Circulation , vol.94 , pp. 1247-1254
    • Hoffman, R.1    Mintz, G.S.2    Dussaillant, G.R.3
  • 17
    • 0031021204 scopus 로고    scopus 로고
    • Analysis of reproducibility of reference lumen quantification with intravascular ultrasound in stented coronary arteries
    • Kearney P.P., Ramo M.P., Shaw T.R.D., Starkey I.R., McMurray J.V., Sutherland G.R. Analysis of reproducibility of reference lumen quantification with intravascular ultrasound in stented coronary arteries. Cathet Cardiovasc Diagn. 40:1997;1-7.
    • (1997) Cathet Cardiovasc Diagn , vol.40 , pp. 1-7
    • Kearney, P.P.1    Ramo, M.P.2    Shaw, T.R.D.3    Starkey, I.R.4    McMurray, J.V.5    Sutherland, G.R.6
  • 18
    • 0029020798 scopus 로고
    • Reproducibility of the intravascular ultrasound assessment of stent implantation in saphenous vein grafts
    • Mintz G.S., Griffin J., Chuang C., et al. Reproducibility of the intravascular ultrasound assessment of stent implantation in saphenous vein grafts. J Am Coll Cardiol. 75:1995;1267-1269.
    • (1995) J Am Coll Cardiol , vol.75 , pp. 1267-1269
    • Mintz, G.S.1    Griffin, J.2    Chuang, C.3
  • 19
    • 0001803773 scopus 로고    scopus 로고
    • Angiography versus intravascular ultrasound-directed stent placement [abstract]
    • Russo R.J., Nicosia A., Teirstein P.S. Angiography versus intravascular ultrasound-directed stent placement [abstract]. J Am Coll Cardiol. 29:(Suppl A):1997;60A.
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Russo, R.J.1    Nicosia, A.2    Teirstein, P.S.3
  • 20
    • 0000784290 scopus 로고    scopus 로고
    • Acute and preliminary follow-up results of the OPTimization with ICUS to Reduce Stent Restenosis (OPTICUS) trial [abstract]
    • for the OPTICUS Investigators
    • Mudra H, Henneke KH, Zeiher AM, de Jaegere P, di Mario C, for the OPTICUS Investigators. Acute and preliminary follow-up results of the OPTimization with ICUS to Reduce Stent Restenosis (OPTICUS) trial [abstract]. J Am Coll Cardiol 1998;31 Suppl A:494A.
    • (1998) J Am Coll Cardiol , vol.31 , Issue.SUPPL A
    • Mudra, H.1    Henneke, K.H.2    Zeiher, A.M.3    De Jaegere, P.4    Di Mario, C.5
  • 21
    • 4243555214 scopus 로고    scopus 로고
    • Do we need intracoronary ultrasound after high-pressure stent expansion? [abstract]
    • Akiyama T., Di Mario C., Reimers B., et al. Do we need intracoronary ultrasound after high-pressure stent expansion? [abstract]. J Am Coll Cardiol. 29:(Suppl A):1997;59A.
    • (1997) J Am Coll Cardiol , vol.29 , Issue.SUPPL. A
    • Akiyama, T.1    Di Mario, C.2    Reimers, B.3
  • 22
    • 0030585707 scopus 로고    scopus 로고
    • Cost and therapeutic modification of intracoronary ultrasound-assisted coronary angioplasty
    • Talley J.D., Mauldin P.D., Becker E.R., Stikovac M., Leesar M.A. Cost and therapeutic modification of intracoronary ultrasound-assisted coronary angioplasty. Am J Cardiol. 77:1996;1278-1282.
    • (1996) Am J Cardiol , vol.77 , pp. 1278-1282
    • Talley, J.D.1    Mauldin, P.D.2    Becker, E.R.3    Stikovac, M.4    Leesar, M.A.5
  • 23
    • 0027508929 scopus 로고
    • Management of restenosis within the Palmaz-Schatz coronary stent (the U.S. multicenter experience)
    • for the U.S. Palmaz-Schatz Stent Investigators
    • Baim DS, Levine MJ, Leon MB, Levine S, Ellis SG, Schatz RA, for the U.S. Palmaz-Schatz Stent Investigators. Management of restenosis within the Palmaz-Schatz coronary stent (the U.S. multicenter experience). Am J Cardiol 1993;71:364-6.
    • (1993) Am J Cardiol , vol.71 , pp. 364-366
    • Baim, D.S.1    Levine, M.J.2    Leon, M.B.3    Levine, S.4    Ellis, S.G.5    Schatz, R.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.