메뉴 건너뛰기




Volumn 54, Issue 6, 2010, Pages 544-549

Spectral-domain optical coherence tomography and scanning laser polarimetry in glaucoma diagnosis

Author keywords

glaucoma; scanning laser polarimetry; spectral domain OCT

Indexed keywords

ADULT; ARTICLE; CLINICAL EVALUATION; CONTROLLED STUDY; DIAGNOSTIC TEST ACCURACY STUDY; DIAGNOSTIC VALUE; DISEASE CLASSIFICATION; FEMALE; GLAUCOMA; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RETINA NERVE CELL; SCANNING LASER POLARIMETRY; SENSITIVITY AND SPECIFICITY;

EID: 78751618039     PISSN: 00215155     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10384-010-0870-5     Document Type: Article
Times cited : (17)

References (29)
  • 1
    • 0026099038 scopus 로고
    • Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss
    • 1:STN:280:DyaK3M7gtlOhuw%3D%3D 1987954
    • A. Sommer J. Katz H.A. Quigley, et al. 1991 Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss Arch Ophthalmol 109 77 83 1:STN:280:DyaK3M7gtlOhuw%3D%3D 1987954
    • (1991) Arch Ophthalmol , vol.109 , pp. 77-83
    • Sommer, A.1    Katz, J.2    Quigley, H.A.3
  • 2
    • 0027475589 scopus 로고
    • Progression of disc and field damage in early glaucoma
    • 1:STN:280:DyaK3s7ktlGitQ%3D%3D 8424726
    • T.G. Zeyen J. Caprioli 1993 Progression of disc and field damage in early glaucoma Arch Ophthalmol 111 62 65 1:STN:280:DyaK3s7ktlGitQ%3D%3D 8424726
    • (1993) Arch Ophthalmol , vol.111 , pp. 62-65
    • Zeyen, T.G.1    Caprioli, J.2
  • 3
  • 4
    • 63649103166 scopus 로고    scopus 로고
    • Scanning laser polarimetry-a review
    • 10.1111/j.1442-9071.2008.01891.x
    • P.S. Da R. Marchesan G. Ravalico 2009 Scanning laser polarimetry-a review Clin Experiment Ophthalmol 37 68 80 10.1111/j.1442-9071.2008.01891.x
    • (2009) Clin Experiment Ophthalmol , vol.37 , pp. 68-80
    • Da, P.S.1    Marchesan, R.2    Ravalico, G.3
  • 5
    • 0346729846 scopus 로고    scopus 로고
    • Optical coherence tomography to detect and manage retinal disease and glaucoma
    • DOI 10.1016/S0002-9394(03)00792-X
    • G.J. Jaffe J. Caprioli 2004 Optical coherence tomography to detect and manage retinal disease and glaucoma Am J Ophthalmol 137 156 169 10.1016/S0002-9394(03)00792-X 14700659 (Pubitemid 38045202)
    • (2004) American Journal of Ophthalmology , vol.137 , Issue.1 , pp. 156-169
    • Jaffe, G.J.1    Caprioli, J.2
  • 6
    • 64449086954 scopus 로고    scopus 로고
    • Comparison of spectral- and time-domain optical coherence tomography for retinal thickness measurements in healthy and diseased eyes
    • 10.1016/j.ajo.2008.11.019 19200530
    • I. Han G. Jaffe 2009 Comparison of spectral- and time-domain optical coherence tomography for retinal thickness measurements in healthy and diseased eyes Am J Ophthalmol 147 847 858 10.1016/j.ajo.2008.11.019 19200530
    • (2009) Am J Ophthalmol , vol.147 , pp. 847-858
    • Han, I.1    Jaffe, G.2
  • 7
    • 2942618989 scopus 로고    scopus 로고
    • Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma
    • DOI 10.1001/archopht.122.6.827
    • F.A. Medeiros L.M. Zangwill C. Bowd R.N. Weinreb 2004 Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma Arch Ophthalmol 122 827 837 10.1001/archopht.122.6.827 15197057 (Pubitemid 38736241)
    • (2004) Archives of Ophthalmology , vol.122 , Issue.6 , pp. 827-837
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3    Weinreb, R.N.4
  • 8
    • 33748260581 scopus 로고    scopus 로고
    • Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma
    • DOI 10.1111/j.1600-0420.2006.00747.x
    • P. Brusini M.L. Salvetat M. Zeppieri C. Tosoni L. Parisi M. Felletti 2006 Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma Acta Ophthalmol Scand 84 650 655 10.1111/j.1600-0420.2006.00747.x 16965496 (Pubitemid 44317545)
    • (2006) Acta Ophthalmologica Scandinavica , vol.84 , Issue.5 , pp. 650-655
    • Brusini, P.1    Salvetat, M.L.2    Zeppieri, M.3    Tosoni, C.4    Parisi, L.5    Felletti, M.6
  • 9
    • 33847700078 scopus 로고    scopus 로고
    • The relationship between optical coherence tomography and scanning laser polarimetry measurements in glaucoma
    • 10.3341/kjo.2006.20.4.225 17302208
    • Y.S. Chung Sohn. YH 2006 The relationship between optical coherence tomography and scanning laser polarimetry measurements in glaucoma Korean J Ophthalmol 20 225 229 10.3341/kjo.2006.20.4.225 17302208
    • (2006) Korean J Ophthalmol , vol.20 , pp. 225-229
    • Chung, Y.S.1    Sohn., Y.H.2
  • 10
    • 29544443026 scopus 로고    scopus 로고
    • Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage
    • DOI 10.1007/s00417-005-0029-0
    • A. Kanamori A. Nagai-Kusuhara M.F. Escano H. Maeda M. Nakamura A. Negi 2006 Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage Graefes Arch Clin Exp Ophthalmol 244 58 68 10.1007/s00417-005-0029-0 16044326 (Pubitemid 43013183)
    • (2006) Graefe's Archive for Clinical and Experimental Ophthalmology , vol.244 , Issue.1 , pp. 58-68
    • Kanamori, A.1    Nagai-Kusuhara, A.2    Escano, M.F.3    Maeda, H.4    Nakamura, M.5    Negi, A.6
  • 11
    • 72749119259 scopus 로고    scopus 로고
    • Relationship between GDx VCC and Stratus OCT in juvenile glaucoma
    • 1:CAS:528:DC%2BD1MXhsFekurjN 10.1038/eye.2009.15 19229266
    • R. Zareii M. Soleimani S. Moghimi Y. Eslami G. Fakhraie H. Amini 2009 Relationship between GDx VCC and Stratus OCT in juvenile glaucoma Eye 23 2182 2186 1:CAS:528:DC%2BD1MXhsFekurjN 10.1038/eye.2009.15 19229266
    • (2009) Eye , vol.23 , pp. 2182-2186
    • Zareii, R.1    Soleimani, M.2    Moghimi, S.3    Eslami, Y.4    Fakhraie, G.5    Amini, H.6
  • 12
    • 0037376904 scopus 로고    scopus 로고
    • Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes
    • DOI 10.1016/S0002-9394(02)02077-9
    • H. Bagga D.S. Greenfield W. Feuer R.W. Knighton 2003 Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes Am J Ophthalmol 135 521 529 10.1016/S0002- 9394(02)02077-9 12654370 (Pubitemid 36315964)
    • (2003) American Journal of Ophthalmology , vol.135 , Issue.4 , pp. 521-529
    • Bagga, H.1    Greenfield, D.S.2    Feuer, W.3    Knighton, R.W.4
  • 13
    • 4744356184 scopus 로고    scopus 로고
    • Diagnostic accuracy of the GDx VCC for glaucoma
    • DOI 10.1016/j.ophtha.2004.04.024, PII S0161642004008206
    • N.J. Reus H.G. Lemij 2004 Diagnostic accuracy of the GDx VCC for glaucoma Ophthalmology 111 1860 1865 10.1016/j.ophtha.2004.04.024 15465547 (Pubitemid 39311837)
    • (2004) Ophthalmology , vol.111 , Issue.10 , pp. 1860-1865
    • Reus, N.J.1    Lemij, H.G.2
  • 14
    • 15044355050 scopus 로고    scopus 로고
    • Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation
    • DOI 10.1016/j.ajo.2004.10.019
    • H. Bagga D.S. Greenfield W.J. Feuer 2005 Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation Am J Ophthalmol 139 437 446 10.1016/j.ajo.2004.10.019 15767051 (Pubitemid 40379069)
    • (2005) American Journal of Ophthalmology , vol.139 , Issue.3 , pp. 437-446
    • Bagga, H.1    Greenfield, D.S.2    Feuer, W.J.3
  • 15
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • 1:STN:280:DyaL1M%2Fns12ksQ%3D%3D 10.2307/2531595 3203132
    • E.R. DeLong D.M. DeLong D.L. Clarke-Pearson 1988 Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach Biometrics 44 837 845 1:STN:280:DyaL1M%2Fns12ksQ%3D%3D 10.2307/2531595 3203132
    • (1988) Biometrics , vol.44 , pp. 837-845
    • Delong, E.R.1    Delong, D.M.2    Clarke-Pearson, D.L.3
  • 16
    • 0028760247 scopus 로고
    • User's guides to the medical literature: III. How to use an article about a diagnostic test: B. What are the results and will they help me in caring for my patients?
    • DOI 10.1001/jama.271.9.703
    • R. Jaeschke G.H. Guyatt D.L. Sackett 1994 Users' guides to the medical literature. III. How to use an article about a diagnostic test. B. What are the results and will they help me in caring for my patients? The Evidence-Based Medicine Working Group JAMA 271 703 707 1:STN:280:DyaK2c7kt1Sqsw%3D%3D 10.1001/jama.271.9.703 8309035 (Pubitemid 24061707)
    • (1994) Journal of the American Medical Association , vol.271 , Issue.9 , pp. 703-707
    • Jaeschke, R.1    Guyatt, G.H.2    Sackett, D.L.3
  • 18
    • 0033653784 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
    • 1:STN:280:DC%2BD3M%2FmsF2iug%3D%3D 10.1016/S0161-6420(00)00341-9 11097610
    • E.Z. Blumenthal J.M. Williams R.N. Weinreb, et al. 2000 Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography Ophthalmology 107 2278 2282 1:STN:280:DC%2BD3M%2FmsF2iug%3D%3D 10.1016/S0161-6420(00)00341-9 11097610
    • (2000) Ophthalmology , vol.107 , pp. 2278-2282
    • Blumenthal, E.Z.1    Williams, J.M.2    Weinreb, R.N.3
  • 20
    • 23244456347 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    • DOI 10.1167/iovs.04-1174
    • D.L. Budenz R.T. Chang X. Huang, et al. 2005 Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes Invest Ophthalmol Vis Sci 46 2440 2443 10.1167/iovs.04-1174 15980233 (Pubitemid 43119491)
    • (2005) Investigative Ophthalmology and Visual Science , vol.46 , Issue.7 , pp. 2440-2443
    • Budenz, D.L.1    Chang, R.T.2    Huang, X.3    Knighton, R.W.4    Tielsch, J.M.5
  • 21
    • 12344316312 scopus 로고    scopus 로고
    • Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects
    • 15638102
    • A. Lleó-Pérez A. Ortuño-Soto M.S. Rahhal, et al. 2004 Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects Eur J Ophthalmol 14 523 530 15638102
    • (2004) Eur J Ophthalmol , vol.14 , pp. 523-530
    • Lleó-Pérez, A.1    Ortuño-Soto, A.2    Rahhal, M.S.3
  • 22
    • 33745460092 scopus 로고    scopus 로고
    • Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes
    • DOI 10.1159/000093082
    • P. Iacono S. Da Pozzo M. Fuser, et al. 2006 Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes Ophthalmologica 220 266 271 10.1159/000093082 16785759 (Pubitemid 43952577)
    • (2006) Ophthalmologica , vol.220 , Issue.4 , pp. 266-271
    • Iacono, P.1    Da Pozzo, S.2    Fuser, M.3    Marchesan, R.4    Ravalico, G.5
  • 23
    • 34247252567 scopus 로고    scopus 로고
    • Long-term variability of GDx VCC retinal nerve fiber layer thickness measurements
    • DOI 10.1097/IJG.0b013e3180391a3c, PII 0006119820070500000001
    • F.A. Medeiros R. Doshi L.M. Zangwill C. Vasile R.N. Weinreb 2007 Longterm variability of GDx VCC retinal nerve fiber layer thickness measurements J Glaucoma 16 277 281 10.1097/IJG.0b013e3180391a3c 17438419 (Pubitemid 46626051)
    • (2007) Journal of Glaucoma , vol.16 , Issue.3 , pp. 277-281
    • Medeiros, F.A.1    Doshi, R.2    Zangwill, L.M.3    Vasile, C.4    Weinreb, R.N.5
  • 24
    • 56149104617 scopus 로고    scopus 로고
    • Longitudinal variability of optic disc and retinal nerve fiber layer measurements
    • 10.1167/iovs.07-1187 18539940
    • C.K. Leung C.Y. Cheung D. Lin C.P. Pang D.S. Lam R.N. Weinreb 2008 Longitudinal variability of optic disc and retinal nerve fiber layer measurements Invest Ophthalmol Vis Sci 49 4886 4892 10.1167/iovs.07-1187 18539940
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 4886-4892
    • Leung, C.K.1    Cheung, C.Y.2    Lin, D.3    Pang, C.P.4    Lam, D.S.5    Weinreb, R.N.6
  • 25
    • 54049136079 scopus 로고    scopus 로고
    • Longitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation
    • 10.1001/archopht.126.10.1359 18852413
    • T.A. Mai H.G. Lemij 2008 Longitudinal measurement variability of corneal birefringence and retinal nerve fiber layer thickness in scanning laser polarimetry with variable corneal compensation Arch Ophthalmol 126 1359 1364 10.1001/archopht.126.10.1359 18852413
    • (2008) Arch Ophthalmol , vol.126 , pp. 1359-1364
    • Mai, T.A.1    Lemij, H.G.2
  • 26
    • 65549087075 scopus 로고    scopus 로고
    • Correlation between local glaucomatous visual field defects and loss of nerve fiber layer thickness measured with scanning laser polarimetry and spectral domain optical coherence tomography
    • 10.1167/iovs.08-2405 19151389
    • F. Horn C. Mardin R. Laemmer, et al. 2009 Correlation between local glaucomatous visual field defects and loss of nerve fiber layer thickness measured with scanning laser polarimetry and spectral domain optical coherence tomography Invest Ophthalmol Vis Sci 50 1971 1977 10.1167/iovs.08-2405 19151389
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 1971-1977
    • Horn, F.1    Mardin, C.2    Laemmer, R.3
  • 27
    • 61549112304 scopus 로고    scopus 로고
    • Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness
    • 1:STN:280:DC%2BD1MzntVWlsg%3D%3D 10.1136/bjo.2008.150698 19304586
    • G. Vizzeri R.N. Weinreb A.O. Gonzalez-Garcia, et al. 2009 Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness Br J Ophthalmol 93 775 781 1:STN:280:DC%2BD1MzntVWlsg%3D%3D 10.1136/bjo.2008.150698 19304586
    • (2009) Br J Ophthalmol , vol.93 , pp. 775-781
    • Vizzeri, G.1    Weinreb, R.N.2    Gonzalez-Garcia, A.O.3
  • 28
    • 67649336413 scopus 로고    scopus 로고
    • Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: A variability and diagnostic performance study
    • 10.1016/j.ophtha.2009.04.013 19464061
    • C.K. Leung C.Y. Cheung R.N. Weinreb, et al. 2009 Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study Ophthalmology 116 1257 1263 10.1016/j.ophtha.2009.04.013 19464061
    • (2009) Ophthalmology , vol.116 , pp. 1257-1263
    • Leung, C.K.1    Cheung, C.Y.2    Weinreb, R.N.3
  • 29
    • 73349089982 scopus 로고    scopus 로고
    • Comparison of glaucoma diagnostic capabilities of Cirrus HD and Stratus optical coherence tomography
    • 10.1001/archophthalmol.2009.296 20008715
    • S.B. Park K.R. Sung S.Y. Kang K.R. Kim M.S. Kook 2009 Comparison of glaucoma diagnostic capabilities of Cirrus HD and Stratus optical coherence tomography Arch Ophthalmol 127 1603 1609 10.1001/archophthalmol.2009.296 20008715
    • (2009) Arch Ophthalmol , vol.127 , pp. 1603-1609
    • Park, S.B.1    Sung, K.R.2    Kang, S.Y.3    Kim, K.R.4    Kook, M.S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.