메뉴 건너뛰기




Volumn 16, Issue 3, 2007, Pages 277-281

Long-term variability of GDx VCC retinal nerve fiber layer thickness measurements

Author keywords

Glaucoma; Nerve fiber layer; Reproducibility; Scanning laser polarimetry

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CORRELATION COEFFICIENT; DIAGNOSTIC IMAGING; FOLLOW UP; GLAUCOMA; HUMAN; NERVE FIBER; OPTIC NERVE; POLARIMETER; POLARIMETRY; PRIORITY JOURNAL; REPRODUCIBILITY; RETINA NERVE FIBER LAYER; SCANNING LASER OPHTHALMOSCOPY; TEST RETEST RELIABILITY; VISUAL FIELD DEFECT;

EID: 34247252567     PISSN: 10570829     EISSN: None     Source Type: Journal    
DOI: 10.1097/IJG.0b013e3180391a3c     Document Type: Article
Times cited : (21)

References (24)
  • 1
    • 0025329536 scopus 로고
    • Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness
    • Weinreb RN, Dreher AW, Coleman A, et al. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol. 1990;108:557-560.
    • (1990) Arch Ophthalmol , vol.108 , pp. 557-560
    • Weinreb, R.N.1    Dreher, A.W.2    Coleman, A.3
  • 2
    • 0036293309 scopus 로고    scopus 로고
    • Individualized compensation of anterior segment birefringence during scanning laser polarimetry
    • Zhou Q, Weinreb RN. Individualized compensation of anterior segment birefringence during scanning laser polarimetry. Invest Ophthalmol Vis Sci. 2002;43:2221-2228.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 2221-2228
    • Zhou, Q.1    Weinreb, R.N.2
  • 3
    • 0037314187 scopus 로고    scopus 로고
    • Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation
    • Weinreb RN, Bowd C, Zangwill LM. Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation. Arch Ophthalmol. 2003;121:218-224.
    • (2003) Arch Ophthalmol , vol.121 , pp. 218-224
    • Weinreb, R.N.1    Bowd, C.2    Zangwill, L.M.3
  • 4
    • 0037358653 scopus 로고    scopus 로고
    • Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry
    • Greenfield DS, Knighton RW, Feuer WJ, et al. Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry. Ophthalmic Surg Lasers Imaging. 2003;34:165-171.
    • (2003) Ophthalmic Surg Lasers Imaging , vol.34 , pp. 165-171
    • Greenfield, D.S.1    Knighton, R.W.2    Feuer, W.J.3
  • 5
    • 0038147111 scopus 로고    scopus 로고
    • Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma
    • Medeiros FA, Zangwill LM, Bowd C, et al. Fourier analysis of scanning laser polarimetry measurements with variable corneal compensation in glaucoma. Invest Ophthalmol Vis Sci. 2003;44:2606-2612.
    • (2003) Invest Ophthalmol Vis Sci , vol.44 , pp. 2606-2612
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3
  • 6
    • 2942618989 scopus 로고    scopus 로고
    • Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and Stratus OCT optical coherence tomograph for the detection of glaucoma
    • Medeiros FA, Zangwill LM, Bowd C, et al. Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and Stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol. 2004;122:827-837.
    • (2004) Arch Ophthalmol , vol.122 , pp. 827-837
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3
  • 7
    • 0030733809 scopus 로고    scopus 로고
    • Improved reproducibility of measurements with the nerve fiber analyzer
    • Tjon-Fo-Sang MJ, van Strik R, de Vries J, et al. Improved reproducibility of measurements with the nerve fiber analyzer. J Glaucoma. 1997;6:203-211.
    • (1997) J Glaucoma , vol.6 , pp. 203-211
    • Tjon-Fo-Sang, M.J.1    van Strik, R.2    de Vries, J.3
  • 8
    • 0031459317 scopus 로고    scopus 로고
    • Reproducibility of retardation measurements with the nerve fiber analyzer II
    • Zangwill L, Berry CA, Garden VS, et al. Reproducibility of retardation measurements with the nerve fiber analyzer II. J Glaucoma. 1997;6:384-389.
    • (1997) J Glaucoma , vol.6 , pp. 384-389
    • Zangwill, L.1    Berry, C.A.2    Garden, V.S.3
  • 9
    • 0031890436 scopus 로고    scopus 로고
    • Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry
    • Hoh ST, Ishikawa H, Greenfield DS, et al. Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry. J Glaucoma. 1998;7:12-15.
    • (1998) J Glaucoma , vol.7 , pp. 12-15
    • Hoh, S.T.1    Ishikawa, H.2    Greenfield, D.S.3
  • 10
    • 0034444873 scopus 로고    scopus 로고
    • Reproducibility of measurements with the nerve fiber analyzer (NFA/GDx)
    • Colen TP, Tjon-Fo-Sang MJ, Mulder PG, et al. Reproducibility of measurements with the nerve fiber analyzer (NFA/GDx). J Glaucoma. 2000;9:363-370.
    • (2000) J Glaucoma , vol.9 , pp. 363-370
    • Colen, T.P.1    Tjon-Fo-Sang, M.J.2    Mulder, P.G.3
  • 11
  • 12
    • 0031955728 scopus 로고    scopus 로고
    • Clinical evaluation of scanning laser polarimetry: I. Intraoperator reproducibility and design of a blood vessel removal algorithm
    • Waldock A, Potts MJ, Sparrow JM, et al. Clinical evaluation of scanning laser polarimetry: I. Intraoperator reproducibility and design of a blood vessel removal algorithm. Br J Ophthalmol. 1998;82:252-259.
    • (1998) Br J Ophthalmol , vol.82 , pp. 252-259
    • Waldock, A.1    Potts, M.J.2    Sparrow, J.M.3
  • 13
    • 0036202752 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber layer thickness measurements using scanning laser polarimetry in pseudophakic eyes
    • Rhee DJ, Greenfield DS, Chen PP, et al. Reproducibility of retinal nerve fiber layer thickness measurements using scanning laser polarimetry in pseudophakic eyes. Ophthalmic Surg Lasers. 2002;33:117-122.
    • (2002) Ophthalmic Surg Lasers , vol.33 , pp. 117-122
    • Rhee, D.J.1    Greenfield, D.S.2    Chen, P.P.3
  • 14
    • 33745460092 scopus 로고    scopus 로고
    • Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes
    • Iacono P, Da Pozzo S, Fuser M, et al. Intersession reproducibility of retinal nerve fiber layer thickness measurements by GDx-VCC in healthy and glaucomatous eyes. Ophthalmologica. 2006;220:266-271.
    • (2006) Ophthalmologica , vol.220 , pp. 266-271
    • Iacono, P.1    Da Pozzo, S.2    Fuser, M.3
  • 15
    • 13444249777 scopus 로고    scopus 로고
    • Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensation
    • Frenkel S, Slonim E, Horani A, et al. Operator learning effect and interoperator reproducibility of the scanning laser polarimeter with variable corneal compensation. Ophthalmology. 2005;112:257-261.
    • (2005) Ophthalmology , vol.112 , pp. 257-261
    • Frenkel, S.1    Slonim, E.2    Horani, A.3
  • 16
    • 16844363609 scopus 로고    scopus 로고
    • Inter-device reproducibility of the scanning laser polarimeter with variable cornea compensation
    • Blumenthal EZ, Frenkel S. Inter-device reproducibility of the scanning laser polarimeter with variable cornea compensation. Eye. 2005;19:308-311.
    • (2005) Eye , vol.19 , pp. 308-311
    • Blumenthal, E.Z.1    Frenkel, S.2
  • 17
    • 0029044003 scopus 로고
    • Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes
    • Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol. 1995;119:627-636.
    • (1995) Am J Ophthalmol , vol.119 , pp. 627-636
    • Weinreb, R.N.1    Shakiba, S.2    Zangwill, L.3
  • 19
    • 33750605700 scopus 로고    scopus 로고
    • Accuracy of GDx variable corneal compensation polarization measurements in normal human eyes: Effect of accommodation, cycloplegia, focus, pupil size, and eye selection on reproducibility
    • Levy NS, Schachar IH. Accuracy of GDx variable corneal compensation polarization measurements in normal human eyes: effect of accommodation, cycloplegia, focus, pupil size, and eye selection on reproducibility. Eye. 2005;1-8.
    • (2005) Eye , pp. 1-8
    • Levy, N.S.1    Schachar, I.H.2
  • 20
    • 3042668265 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT
    • Paunescu LA, Schuman JS, Price LL, et al. Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT. Invest Ophthalmol Vis Sci. 2004;45:1716-1724.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 1716-1724
    • Paunescu, L.A.1    Schuman, J.S.2    Price, L.L.3
  • 21
    • 0029851416 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
    • Schuman JS, Pedut-Kloizman T, Hertzmark E, et al. Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology. 1996;103:1889-1898.
    • (1996) Ophthalmology , vol.103 , pp. 1889-1898
    • Schuman, J.S.1    Pedut-Kloizman, T.2    Hertzmark, E.3
  • 22
    • 23244456347 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes
    • Budenz DL, Chang RT, Huang X, et al. Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes. Invest Ophthalmol Vis Sci. 2005;46:2440-2443.
    • (2005) Invest Ophthalmol Vis Sci , vol.46 , pp. 2440-2443
    • Budenz, D.L.1    Chang, R.T.2    Huang, X.3
  • 23
    • 0030980942 scopus 로고    scopus 로고
    • Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry
    • Poinoosawmy D, Fontana L, Wu JX, et al. Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry. Br J Ophthalmol. 1997;81:350-354.
    • (1997) Br J Ophthalmol , vol.81 , pp. 350-354
    • Poinoosawmy, D.1    Fontana, L.2    Wu, J.X.3
  • 24
    • 0029583748 scopus 로고
    • Evaluation of the effect of aging on the retinal nerve fiber layer thickness using scanning laser polarimetry
    • Chi Q, Tomita G, Inazumi K, et al. Evaluation of the effect of aging on the retinal nerve fiber layer thickness using scanning laser polarimetry. J Glaucoma. 1995;4:406-413.
    • (1995) J Glaucoma , vol.4 , pp. 406-413
    • Chi, Q.1    Tomita, G.2    Inazumi, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.