메뉴 건너뛰기




Volumn 151, Issue 2, 2011, Pages 416-422

Integration of a sensitive carbon nanotube composite electrode in a ceramic microanalyzer for the amperometric determination of free chlorine

Author keywords

Amperometric sensor; Carbon nanotube composite; Chlorine; Green tape ceramics; Microanalyzer

Indexed keywords

AMPEROMETRIC DETECTION; AMPEROMETRIC DETERMINATION; ANALYTICAL PERFORMANCE; AUTO CALIBRATION; CARBON NANOTUBE COMPOSITE; CARBON-NANOTUBE COMPOSITES; COMPOSITE ELECTRODE; COUNTER ELECTRODES; FABRICATION PROCESS; FREE CHLORINE; GREEN TAPE; HIGHLY SENSITIVE; LOW DETECTION LIMIT; MICROANALYZERS; MULTI COMMUTATIONS; REAL SAMPLES; STANDARD SOLUTIONS; STOCK SOLUTIONS; SURFACE RENEWABILITY; SYSTEM CHARACTERISTICS; SYSTEM FUNCTIONALITY; USER INTERACTION; WATER SAMPLES; WORKING ELECTRODE;

EID: 78751575921     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2010.10.017     Document Type: Article
Times cited : (33)

References (52)
  • 1
    • 0033485352 scopus 로고    scopus 로고
    • Disposable optical sensor chip for medical diagnostics: New ways in bioanalysis
    • K. Schult, A. Katerkamp, D. Trau, F. Grawe, K. Cammann, and M. Meusel Disposable optical sensor chip for medical diagnostics: new ways in bioanalysis Anal. Chem. 71 1999 5430 5435
    • (1999) Anal. Chem. , vol.71 , pp. 5430-5435
    • Schult, K.1    Katerkamp, A.2    Trau, D.3    Grawe, F.4    Cammann, K.5    Meusel, M.6
  • 3
    • 9744273447 scopus 로고    scopus 로고
    • Towards advanced chemical microsensors - An overview
    • W. Wroblewski, A. Dybko, E. Malinowska, and Z. Brzozka Towards advanced chemical microsensors - an overview Talanta 63 2004 33 39
    • (2004) Talanta , vol.63 , pp. 33-39
    • Wroblewski, W.1    Dybko, A.2    Malinowska, E.3    Brzozka, Z.4
  • 4
    • 33749046360 scopus 로고    scopus 로고
    • Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters
    • M. Baeza, N. Ibañez-Garcia, J. Baucells, J. Bartrolí, and J. Alonso Microflow injection system based on a multicommutation technique for nitrite determination in wastewaters Analyst 131 2006 1109 1115
    • (2006) Analyst , vol.131 , pp. 1109-1115
    • Baeza, M.1    Ibañez-Garcia, N.2    Baucells, J.3    Bartrolí, J.4    Alonso, J.5
  • 5
    • 0035984039 scopus 로고    scopus 로고
    • Poly(dimethylsiloxane) as a material for fabricating microfluidic devices
    • J.C. McDonald, and G.M. Whitesides Poly(dimethylsiloxane) as a material for fabricating microfluidic devices Acc. Chem. Res. 35 2002 491 499
    • (2002) Acc. Chem. Res. , vol.35 , pp. 491-499
    • McDonald, J.C.1    Whitesides, G.M.2
  • 7
    • 0037438528 scopus 로고    scopus 로고
    • Fabrication of complex three-dimensional microchannel systems in PDMS
    • H.K. Wu, T.W. Odom, D.T. Chiu, and G.M. Whitesides Fabrication of complex three-dimensional microchannel systems in PDMS J. Am. Chem. Soc. 125 2003 554 559
    • (2003) J. Am. Chem. Soc. , vol.125 , pp. 554-559
    • Wu, H.K.1    Odom, T.W.2    Chiu, D.T.3    Whitesides, G.M.4
  • 8
    • 39149145836 scopus 로고    scopus 로고
    • Green-tape ceramics New technological approach for integrating electronics and fluidics in microsystems. TrAC-Trends
    • N. Ibañez-Garcia, C.S. Martínez-Cisneros, F. Valdes, and J. Alonso Green-tape ceramics New technological approach for integrating electronics and fluidics in microsystems. TrAC-Trends Anal. Chem. 27 2008 24 33
    • (2008) Anal. Chem. , vol.27 , pp. 24-33
    • Ibañez-Garcia, N.1    Martínez-Cisneros, C.S.2    Valdes, F.3    Alonso, J.4
  • 10
    • 56049123143 scopus 로고    scopus 로고
    • Miniaturized low temperature co-fired ceramics (LTCC) biosensor for amperometric gas sensing
    • S. Achmann, M. Hammerle, J. Kita, and R. Moos Miniaturized low temperature co-fired ceramics (LTCC) biosensor for amperometric gas sensing Sens. Actuators B: Chem. 135 2008 89 95
    • (2008) Sens. Actuators B: Chem. , vol.135 , pp. 89-95
    • Achmann, S.1    Hammerle, M.2    Kita, J.3    Moos, R.4
  • 12
    • 0036894404 scopus 로고    scopus 로고
    • Dual conductivity/amperometric detection system for microchip capillary electrophoresis
    • J. Wang, and M. Pumera Dual conductivity/amperometric detection system for microchip capillary electrophoresis Anal. Chem. 74 2002 5919 5923
    • (2002) Anal. Chem. , vol.74 , pp. 5919-5923
    • Wang, J.1    Pumera, M.2
  • 13
    • 0345504149 scopus 로고    scopus 로고
    • The utilization of low temperature co-fired ceramics (LTCC-ML) technology for meso-scale EMS, a simple thermistor based flow sensor
    • M.R. Gongora-Rubio, L.M. Sola-Laguna, P.J. Moffett, and J.J. Santiago-Aviles The utilization of low temperature co-fired ceramics (LTCC-ML) technology for meso-scale EMS, a simple thermistor based flow sensor Sens. Actuators A: Phys. 73 1999 215 221
    • (1999) Sens. Actuators A: Phys. , vol.73 , pp. 215-221
    • Gongora-Rubio, M.R.1    Sola-Laguna, L.M.2    Moffett, P.J.3    Santiago-Aviles, J.J.4
  • 15
    • 34249016331 scopus 로고    scopus 로고
    • Pesticide determination by enzymatic inhibition and amperometric detection in a low-temperature cofired ceramics microsystem
    • X. Llopis, N. Ibañez-Garcia, S. Alegret, and J. Alonso Pesticide determination by enzymatic inhibition and amperometric detection in a low-temperature cofired ceramics microsystem Anal. Chem. 79 2007 3662 3666
    • (2007) Anal. Chem. , vol.79 , pp. 3662-3666
    • Llopis, X.1    Ibañez-Garcia, N.2    Alegret, S.3    Alonso, J.4
  • 16
    • 33646541056 scopus 로고    scopus 로고
    • Continuous flow analytical microsystems based on low-temperature co-fired ceramic technology integrated potentiometric detection based on solvent polymeric ion-selective electrodes
    • N. Ibañez-Garcia, M.B. Mercader, Z.M. da Rocha, C.A. Seabra, M.R. Gongora-Rubio, and J. Alonso Continuous flow analytical microsystems based on low-temperature co-fired ceramic technology integrated potentiometric detection based on solvent polymeric ion-selective electrodes Anal. Chem. 78 2006 2985 2992
    • (2006) Anal. Chem. , vol.78 , pp. 2985-2992
    • Ibañez-Garcia, N.1    Mercader, M.B.2    Da Rocha, Z.M.3    Seabra, C.A.4    Gongora-Rubio, M.R.5    Alonso, J.6
  • 17
    • 76149110104 scopus 로고    scopus 로고
    • Ceramic microsystem incorporating a microreactor with immobilized biocatalyst for enzymatic spectrophotometric assays
    • M. Baeza, C. López, J. Alonso, J. López-Santín, and G. Álvaro Ceramic microsystem incorporating a microreactor with immobilized biocatalyst for enzymatic spectrophotometric assays Anal. Chem. 82 2010 1006 1011
    • (2010) Anal. Chem. , vol.82 , pp. 1006-1011
    • Baeza, M.1    López, C.2    Alonso, J.3    López-Santín, J.4    Álvaro, G.5
  • 20
    • 68549096369 scopus 로고    scopus 로고
    • Detection systems for microfluidic devices with a major focus on pharmaceutical and chiral analysis
    • I. Tanret, D. Mangelings, and Y. Vander Heyden Detection systems for microfluidic devices with a major focus on pharmaceutical and chiral analysis Curr. Pharma. Anal. 5 2009 101 111
    • (2009) Curr. Pharma. Anal. , vol.5 , pp. 101-111
    • Tanret, I.1    Mangelings, D.2    Vander Heyden, Y.3
  • 21
    • 0036863549 scopus 로고    scopus 로고
    • Recent developments in amperometric detection for microchip capillary electrophoresis
    • W.R. Vandaveer, S.A. Pasas, R.S. Martin, and S.M. Lunte Recent developments in amperometric detection for microchip capillary electrophoresis Electrophoresis 23 2002 3667 3677
    • (2002) Electrophoresis , vol.23 , pp. 3667-3677
    • Vandaveer, W.R.1    Pasas, S.A.2    Martin, R.S.3    Lunte, S.M.4
  • 22
    • 0037060151 scopus 로고    scopus 로고
    • Electrochemical detection for microscale analytical systems: A review
    • J. Wang Electrochemical detection for microscale analytical systems: a review Talanta 56 2002 223 231
    • (2002) Talanta , vol.56 , pp. 223-231
    • Wang, J.1
  • 23
    • 0034601244 scopus 로고    scopus 로고
    • Capillary electrophoresis microchips with thick-film amperometric detectors: Separation and detection of phenolic compounds
    • J. Wang, M.P. Chatrathi, and B.M. Tian Capillary electrophoresis microchips with thick-film amperometric detectors: separation and detection of phenolic compounds Anal. Chim. Acta 416 2000 9 14
    • (2000) Anal. Chim. Acta , vol.416 , pp. 9-14
    • Wang, J.1    Chatrathi, M.P.2    Tian, B.M.3
  • 24
    • 0036500324 scopus 로고    scopus 로고
    • In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat
    • R.S. Martin, K.L. Ratzlaff, B.H. Huynh, and S.M. Lunte In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat Anal. Chem. 74 2002 1136 1143
    • (2002) Anal. Chem. , vol.74 , pp. 1136-1143
    • Martin, R.S.1    Ratzlaff, K.L.2    Huynh, B.H.3    Lunte, S.M.4
  • 25
    • 18844415627 scopus 로고    scopus 로고
    • Electrochemical techniques for lab-on-a-chip applications
    • L. Nyholm Electrochemical techniques for lab-on-a-chip applications Analyst 130 2005 599 605
    • (2005) Analyst , vol.130 , pp. 599-605
    • Nyholm, L.1
  • 26
    • 50649124861 scopus 로고    scopus 로고
    • Electrical conductivity modeling of multiple carbon fillers in liquid crystal polymer composites for fuel cell bipolar plate applications
    • R.L. Barton, J.M. Keith, and J.A. King Electrical conductivity modeling of multiple carbon fillers in liquid crystal polymer composites for fuel cell bipolar plate applications J. New Mat. Electrochem. 11 2008 181 186
    • (2008) J. New Mat. Electrochem. , vol.11 , pp. 181-186
    • Barton, R.L.1    Keith, J.M.2    King, J.A.3
  • 28
    • 33748290092 scopus 로고    scopus 로고
    • Polymer nanocomposites containing carbon nanotubes
    • M. Moniruzzaman, and K.I. Winey Polymer nanocomposites containing carbon nanotubes Macromolecules 39 2006 5194 5205
    • (2006) Macromolecules , vol.39 , pp. 5194-5205
    • Moniruzzaman, M.1    Winey, K.I.2
  • 29
    • 0036799265 scopus 로고    scopus 로고
    • Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes
    • M. Musameh, J. Wang, A. Merkoi, and Y.H. Lin Low-potential stable NADH detection at carbon-nanotube-modified glassy carbon electrodes Electrochem. Comm. 4 2002 743 746
    • (2002) Electrochem. Comm. , vol.4 , pp. 743-746
    • Musameh, M.1    Wang, J.2    Merkoi, A.3    Lin, Y.H.4
  • 32
    • 31844453131 scopus 로고    scopus 로고
    • Carbon nanotube-epoxy composites for electrochemical sensing
    • M. Pumera, A. Merkoi, and S. Alegret Carbon nanotube-epoxy composites for electrochemical sensing Sens. Actuators B: Chem. 113 2006 617 622
    • (2006) Sens. Actuators B: Chem. , vol.113 , pp. 617-622
    • Pumera, M.1    Merkoi, A.2    Alegret, S.3
  • 33
    • 70349913014 scopus 로고    scopus 로고
    • Recent advances in electroanalysis of organic compounds at carbon paste electrodes C
    • J. Zima, I. Svancara, J. Barek, and K. Vytras Recent advances in electroanalysis of organic compounds at carbon paste electrodes C Rev. Anal. Chem. 39 2009 204 227
    • (2009) Rev. Anal. Chem. , vol.39 , pp. 204-227
    • Zima, J.1    Svancara, I.2    Barek, J.3    Vytras, K.4
  • 34
    • 0036558165 scopus 로고    scopus 로고
    • Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes
    • J.X. Wang, M.X. Li, Z.J. Shi, N.Q. Li, and Z.N. Gu Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes Anal. Chem. 74 2002 1993 1997
    • (2002) Anal. Chem. , vol.74 , pp. 1993-1997
    • Wang, J.X.1    Li, M.X.2    Shi, Z.J.3    Li, N.Q.4    Gu, Z.N.5
  • 36
    • 0142135887 scopus 로고    scopus 로고
    • Carbon nanotube purification: Preparation and characterization of carbon nanotube paste electrodes
    • F. Valentini, A. Amine, S. Orlanducci, M.L. Terranova, and G. Palleschi Carbon nanotube purification: preparation and characterization of carbon nanotube paste electrodes Anal. Chem. 75 2003 5413 5421
    • (2003) Anal. Chem. , vol.75 , pp. 5413-5421
    • Valentini, F.1    Amine, A.2    Orlanducci, S.3    Terranova, M.L.4    Palleschi, G.5
  • 37
    • 0038709731 scopus 로고    scopus 로고
    • Carbon nanotube/teflon composite electrochemical sensors and biosensors
    • J. Wang, and M. Musameh Carbon nanotube/teflon composite electrochemical sensors and biosensors Anal. Chem. 75 2003 2075 2079
    • (2003) Anal. Chem. , vol.75 , pp. 2075-2079
    • Wang, J.1    Musameh, M.2
  • 38
    • 0036858075 scopus 로고    scopus 로고
    • Mechanical and electrical properties of a MWNT/epoxy composite
    • A. Allaoui, S. Bai, H.M. Cheng, and J.B. Bai Mechanical and electrical properties of a MWNT/epoxy composite Compos. Sci. Technol. 62 2002 1993 1998
    • (2002) Compos. Sci. Technol. , vol.62 , pp. 1993-1998
    • Allaoui, A.1    Bai, S.2    Cheng, H.M.3    Bai, J.B.4
  • 39
    • 0347758345 scopus 로고    scopus 로고
    • Capillary electrophoresis microchip with a carbon nanotube-modified electrochemical detector
    • J. Wang, G. Chen, M.P. Chatrathi, and M. Musameh Capillary electrophoresis microchip with a carbon nanotube-modified electrochemical detector Anal. Chem. 76 2004 298 302
    • (2004) Anal. Chem. , vol.76 , pp. 298-302
    • Wang, J.1    Chen, G.2    Chatrathi, M.P.3    Musameh, M.4
  • 40
    • 33846404902 scopus 로고    scopus 로고
    • Carbon nanotube/poly(methyl methacrylate) (CNT/PMMA) composite electrode fabricated by in situ polymerization for microchip capillary electrophoresis
    • X. Yao, H.X. Wu, J. Wang, S. Qu, and G. Chen Carbon nanotube/poly(methyl methacrylate) (CNT/PMMA) composite electrode fabricated by in situ polymerization for microchip capillary electrophoresis Chem. Eur. J. 13 2007 846 853
    • (2007) Chem. Eur. J. , vol.13 , pp. 846-853
    • Yao, X.1    Wu, H.X.2    Wang, J.3    Qu, S.4    Chen, G.5
  • 41
    • 62749139716 scopus 로고    scopus 로고
    • Towards lab-on-a-chip approaches in real analytical domains based on microfluidic chips/electrochemical multi-walled carbon nanotube platforms
    • A.G. Crevillén, M. Pumera, M.C. González, and A. Escarpa Towards lab-on-a-chip approaches in real analytical domains based on microfluidic chips/electrochemical multi-walled carbon nanotube platforms Lab Chip 9 2009 346 353
    • (2009) Lab Chip , vol.9 , pp. 346-353
    • Crevillén, A.G.1    Pumera, M.2    González, M.C.3    Escarpa, A.4
  • 42
    • 35348997333 scopus 로고    scopus 로고
    • Food analysis on microfluidic devices using ultrasensitive carbon nanotubes detectors
    • A.G. Crevillén, M. Ávila, M. Pumera, M.C. González, and A. Escarpa Food analysis on microfluidic devices using ultrasensitive carbon nanotubes detectors Anal. Chem. 79 2007 7408 7415
    • (2007) Anal. Chem. , vol.79 , pp. 7408-7415
    • Crevillén, A.G.1    Ávila, M.2    Pumera, M.3    González, M.C.4    Escarpa, A.5
  • 44
    • 77950298029 scopus 로고    scopus 로고
    • Strategies for the optimization of carbon nanotube/polymer ratio in composite materials: Applications as voltammetric sensors
    • R. Olivé-Monllau, M.J. Esplandiu, J. Bartrolí, M. Baeza, and F. Céspedes Strategies for the optimization of carbon nanotube/polymer ratio in composite materials: applications as voltammetric sensors Sens. Actuators B: Chem. 146 2010 353 360
    • (2010) Sens. Actuators B: Chem. , vol.146 , pp. 353-360
    • Olivé-Monllau, R.1    Esplandiu, M.J.2    Bartrolí, J.3    Baeza, M.4    Céspedes, F.5
  • 45
    • 77952321454 scopus 로고    scopus 로고
    • Highly sensitive CNT composite amperometric sensors integrated in an automated flow system for the determination of free chlorine in waters
    • R. Olivé-Monllau, A. Pereira, J. Bartrolí, M. Baeza, and F. Céspedes Highly sensitive CNT composite amperometric sensors integrated in an automated flow system for the determination of free chlorine in waters Talanta 81 2010 1593 1598
    • (2010) Talanta , vol.81 , pp. 1593-1598
    • Olivé-Monllau, R.1    Pereira, A.2    Bartrolí, J.3    Baeza, M.4    Céspedes, F.5
  • 48
    • 78751573384 scopus 로고    scopus 로고
    • 24-26 November 2008, Sao Paulo, Brazil
    • Z.M. Da Rocha, C.S. Martínez-Cisneros, M. Ferreira, N. Ibáñez-García, A. Seabra, J. Alonso M.R. Gongora-Rubio, Proceeding Ibersensors, 24-26 November 2008, Sao Paulo, Brazil.
    • Proceeding Ibersensors
    • Da Rocha, Z.M.1
  • 50
    • 78751568491 scopus 로고    scopus 로고
    • Decret 95, 22 Febrero, Diari Oficial de la Generalitat de Catalunya, DOGC, Generalitat de Catalunyain, 2000
    • Decret 95, 22 Febrero, Diari Oficial de la Generalitat de Catalunya, DOGC, Generalitat de Catalunyain, 2000.
  • 51
    • 59849116408 scopus 로고    scopus 로고
    • Simple modeling of the physical sample dispersion process in rectangular meso (micro) channels with pressure-driven flows
    • M. Baeza, J.L. Montesinos, J. Alonso, and J. Bartrolí Simple modeling of the physical sample dispersion process in rectangular meso (micro) channels with pressure-driven flows Anal. Bioanal. Chem. 393 2009 1233 1243
    • (2009) Anal. Bioanal. Chem. , vol.393 , pp. 1233-1243
    • Baeza, M.1    Montesinos, J.L.2    Alonso, J.3    Bartrolí, J.4
  • 52
    • 1642475441 scopus 로고    scopus 로고
    • A miniaturized FIA system for the determination of residual chlorine in environmental water samples
    • J.Y. Jin, Y. Suzuki, N. Ishikawa, and T. Takeuchi A miniaturized FIA system for the determination of residual chlorine in environmental water samples Anal. Sci. 20 2004 205 207
    • (2004) Anal. Sci. , vol.20 , pp. 205-207
    • Jin, J.Y.1    Suzuki, Y.2    Ishikawa, N.3    Takeuchi, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.