메뉴 건너뛰기




Volumn 135, Issue 1, 2008, Pages 89-95

Miniaturized low temperature co-fired ceramics (LTCC) biosensor for amperometric gas sensing

Author keywords

Amperometric enzyme sensor; Ceramic diffusion membrane; Chlorination; Formaldehyde; Gas sensor; Low temperature co fired ceramics

Indexed keywords

BIOSENSORS; BUILDING MATERIALS; CERAMIC MATERIALS; CHEMICAL SENSORS; CHLORINATION; CHLORINE; DIFFUSION; ELECTROCHEMICAL ELECTRODES; ENZYMES; FORMALDEHYDE; GAS DETECTORS; GAS SENSING ELECTRODES; GASES; MINIATURE INSTRUMENTS; SEMICONDUCTOR DOPING; SENSORS; SILVER;

EID: 56049123143     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2008.07.024     Document Type: Article
Times cited : (36)

References (30)
  • 1
    • 0034250915 scopus 로고    scopus 로고
    • Microfabrication of chemical sensors and biosensors for environmental monitoring
    • Suzuki H. Microfabrication of chemical sensors and biosensors for environmental monitoring. Mater. Sci. Eng. C 12 (2000) 55-61
    • (2000) Mater. Sci. Eng. C , vol.12 , pp. 55-61
    • Suzuki, H.1
  • 3
    • 0036571769 scopus 로고    scopus 로고
    • Three-dimensional low temperature co-fired ceramic shells for miniature systems applications
    • Li J., and Ananthasuresh G.K. Three-dimensional low temperature co-fired ceramic shells for miniature systems applications. J. Micromech. Microeng. 12 (2002) 198-203
    • (2002) J. Micromech. Microeng. , vol.12 , pp. 198-203
    • Li, J.1    Ananthasuresh, G.K.2
  • 4
    • 34249016331 scopus 로고    scopus 로고
    • Pesticide determination by enzymatic inhibition and amperometric detection in a low-temperature cofired ceramics microsystem
    • Llopis X., Ibanez-Garcia N., Alegret S., and Alonso J. Pesticide determination by enzymatic inhibition and amperometric detection in a low-temperature cofired ceramics microsystem. Anal. Chem. 79 (2007) 3662-3666
    • (2007) Anal. Chem. , vol.79 , pp. 3662-3666
    • Llopis, X.1    Ibanez-Garcia, N.2    Alegret, S.3    Alonso, J.4
  • 5
    • 0345504149 scopus 로고    scopus 로고
    • The utilization of low temperature co-fired ceramics (LTCC-ML) technology for meso-scale EMS, a simple thermistor based flow sensor
    • Gongora-Rubio M., Solá-Laguna L.M., Moffett P.J., and Santiago-Avilés J.J. The utilization of low temperature co-fired ceramics (LTCC-ML) technology for meso-scale EMS, a simple thermistor based flow sensor. Sens. Actuators A: Phys. 73 (1999) 215-221
    • (1999) Sens. Actuators A: Phys. , vol.73 , pp. 215-221
    • Gongora-Rubio, M.1    Solá-Laguna, L.M.2    Moffett, P.J.3    Santiago-Avilés, J.J.4
  • 6
    • 20744444884 scopus 로고    scopus 로고
    • Preparation and electrochemical characterization of a new nanosensor based on self-assembled monolayer of cysteamine functionalized with phosphate groups
    • Shervedani R.K., and Mozaffari S.A. Preparation and electrochemical characterization of a new nanosensor based on self-assembled monolayer of cysteamine functionalized with phosphate groups. Surf. Coat. Technol. 198 (2005) 123-128
    • (2005) Surf. Coat. Technol. , vol.198 , pp. 123-128
    • Shervedani, R.K.1    Mozaffari, S.A.2
  • 7
    • 33645218729 scopus 로고    scopus 로고
    • Multilayered construction of glucose oxidase and gold nanoparticles on Au electrodes based on layer-by-layer covalent attachment
    • Yang W., Wang J., Zhao S., Sun Y., and Sun C. Multilayered construction of glucose oxidase and gold nanoparticles on Au electrodes based on layer-by-layer covalent attachment. Electrochem. Commun. 8 (2006) 665-672
    • (2006) Electrochem. Commun. , vol.8 , pp. 665-672
    • Yang, W.1    Wang, J.2    Zhao, S.3    Sun, Y.4    Sun, C.5
  • 8
    • 33845986720 scopus 로고    scopus 로고
    • Evaluation of screen-printed gold on low-temperature co-fired ceramic as a substrate for the immobilization of electrochemical immunoassays
    • Fakunle E.S., Aguilar Z.P., Shultz J.L., Toland A.D., and Fritsch I. Evaluation of screen-printed gold on low-temperature co-fired ceramic as a substrate for the immobilization of electrochemical immunoassays. Langmuir 22 (2006) 10844-10853
    • (2006) Langmuir , vol.22 , pp. 10844-10853
    • Fakunle, E.S.1    Aguilar, Z.P.2    Shultz, J.L.3    Toland, A.D.4    Fritsch, I.5
  • 13
    • 0037380950 scopus 로고    scopus 로고
    • Planar solid-state potentiometric carbon dioxide sensors incorporating polymer-gel electrolyte
    • McMurray H.N., Lewis M.J., and Brinz T. Planar solid-state potentiometric carbon dioxide sensors incorporating polymer-gel electrolyte. Electrochem. Solid State Lett. 6 (2003) H5-H7
    • (2003) Electrochem. Solid State Lett. , vol.6
    • McMurray, H.N.1    Lewis, M.J.2    Brinz, T.3
  • 16
    • 14744282237 scopus 로고    scopus 로고
    • Ceramic meso hot-plates for gas sensors
    • Rettig F., and Moos R. Ceramic meso hot-plates for gas sensors. Sens. Actuators B: Chem. 103 (2004) 91-97
    • (2004) Sens. Actuators B: Chem. , vol.103 , pp. 91-97
    • Rettig, F.1    Moos, R.2
  • 19
    • 41549162548 scopus 로고    scopus 로고
    • Amperometric enzyme-based biosensor for direct detection of formaldehyde in the gas phase: dependence on electrolyte composition
    • Achmann S., Hämmerle M., and Moos R. Amperometric enzyme-based biosensor for direct detection of formaldehyde in the gas phase: dependence on electrolyte composition. Electroanalysis 20 (2008) 410-417
    • (2008) Electroanalysis , vol.20 , pp. 410-417
    • Achmann, S.1    Hämmerle, M.2    Moos, R.3
  • 21
    • 0032166067 scopus 로고    scopus 로고
    • Thick film silver-silver chloride reference electrodes
    • Cranny A.W.J., and Atkinson J.K. Thick film silver-silver chloride reference electrodes. Meas. Sci. Technol. 9 (1998) 1557-1565
    • (1998) Meas. Sci. Technol. , vol.9 , pp. 1557-1565
    • Cranny, A.W.J.1    Atkinson, J.K.2
  • 22
    • 0001120583 scopus 로고
    • Glucose sensitivity of poly(pyrrole) films containing immobilized glucose dehydrogenase, nicotinamide adenine dinucleotide, and [beta]-naphthoquinonesulphonate ions
    • Kajiya Y., Matsumoto H., and Yoneyama H. Glucose sensitivity of poly(pyrrole) films containing immobilized glucose dehydrogenase, nicotinamide adenine dinucleotide, and [beta]-naphthoquinonesulphonate ions. J. Electroanal. Chem. 319 1/2 (1991) 185-194
    • (1991) J. Electroanal. Chem. , vol.319 , Issue.1-2 , pp. 185-194
    • Kajiya, Y.1    Matsumoto, H.2    Yoneyama, H.3
  • 23
    • 33847250441 scopus 로고    scopus 로고
    • Preparation and characterization of hydrophobic ceramic hollow fiber membrane
    • Koonaphapdeelert S., and Li K. Preparation and characterization of hydrophobic ceramic hollow fiber membrane. J. Membr. Sci. 291 (2007) 70-76
    • (2007) J. Membr. Sci. , vol.291 , pp. 70-76
    • Koonaphapdeelert, S.1    Li, K.2
  • 24
    • 23044443022 scopus 로고    scopus 로고
    • Hydrophobic modification of γ-alumina membranes with organochlorosilanes
    • Sah A., Castricum H.L., Bliek A., Blank D.H.A., and ten Elshof J.E. Hydrophobic modification of γ-alumina membranes with organochlorosilanes. J. Membr. Sci. 243 (2004) 125-132
    • (2004) J. Membr. Sci. , vol.243 , pp. 125-132
    • Sah, A.1    Castricum, H.L.2    Bliek, A.3    Blank, D.H.A.4    ten Elshof, J.E.5
  • 26
    • 41549141430 scopus 로고    scopus 로고
    • Amperometric enzyme-based gas sensor for formaldehyde: impact of possible interferences
    • Achmann S., Hämmerle M., and Moos R. Amperometric enzyme-based gas sensor for formaldehyde: impact of possible interferences. Sensors 8 (2008) 1351-1365
    • (2008) Sensors , vol.8 , pp. 1351-1365
    • Achmann, S.1    Hämmerle, M.2    Moos, R.3
  • 28
    • 1042299096 scopus 로고    scopus 로고
    • Electrooxidative polymerization of phenothiazine derivatives on screen-printed carbon electrode and its application to determine NADH in flow injection analysis system
    • Gao Q., Wang W., Ma Y., and Yang X. Electrooxidative polymerization of phenothiazine derivatives on screen-printed carbon electrode and its application to determine NADH in flow injection analysis system. Talanta 62 3 (2004) 477-482
    • (2004) Talanta , vol.62 , Issue.3 , pp. 477-482
    • Gao, Q.1    Wang, W.2    Ma, Y.3    Yang, X.4
  • 29
    • 0031074252 scopus 로고    scopus 로고
    • Electrochemical oxidation of reduced nicotineamide coenzymes at Au electrodes modified with phenothiazine derivative monolayers
    • Othani M., Kuwabata S., and Yoneyama H. Electrochemical oxidation of reduced nicotineamide coenzymes at Au electrodes modified with phenothiazine derivative monolayers. J. Electroanal. Chem. 422 (1997) 45-54
    • (1997) J. Electroanal. Chem. , vol.422 , pp. 45-54
    • Othani, M.1    Kuwabata, S.2    Yoneyama, H.3
  • 30
    • 33845430924 scopus 로고    scopus 로고
    • 2 amperometric detection at low applied potential for oxidase and dehydrogenase based biosensor applications
    • 2 amperometric detection at low applied potential for oxidase and dehydrogenase based biosensor applications. Biosens. Bioelectron. 22 (2007) 854-862
    • (2007) Biosens. Bioelectron. , vol.22 , pp. 854-862
    • Ricci, F.1    Amine, A.2    Moscone, D.3    Palleschi, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.