메뉴 건너뛰기




Volumn 63, Issue 6, 2010, Pages 1456-1462

Nonlinear inverse reconstruction for real-time MRI of the human heart using undersampled radial FLASH

Author keywords

Cardiac imaging; GPU; Inverse problems; Iterative reconstruction; Nonlinear inversion; Parallel imaging; Real time imaging

Indexed keywords

GRAPHICS PROCESSING UNIT; IMAGE RECONSTRUCTION; ITERATIVE METHODS;

EID: 77952692860     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22453     Document Type: Article
Times cited : (103)

References (16)
  • 1
    • 34250364567 scopus 로고    scopus 로고
    • Joint image reconstruction and sensitivity estimation in SENSE (JSENSE)
    • DOI 10.1002/mrm.21245
    • Ying L, Sheng J. Joint image reconstruction and sensitivity estimation in SENSE (JSENSE). Magn Reson Med 2007;57:1196-1202. (Pubitemid 46911305)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.6 , pp. 1196-1202
    • Ying, L.1    Sheng, J.2
  • 2
    • 51449090553 scopus 로고    scopus 로고
    • Image reconstruction by regularized nonlinear inversion: Application to autocalibrated parallel imaging
    • Uecker M, Hohage T, Block KT, Frahm J. Image reconstruction by regularized nonlinear inversion: application to autocalibrated parallel imaging. Magn Reson Med 2008;60:674-682.
    • (2008) Magn Reson Med , vol.60 , pp. 674-682
    • Uecker, M.1    Hohage, T.2    Block, K.T.3    Frahm, J.4
  • 5
    • 72249114693 scopus 로고    scopus 로고
    • Real-time reconstruction of sensitivity encoded radial magnetic resonance imaging using a graphics processing unit
    • Sørensen TS, Atkinson D, Schaeffter T, Hansen, MS. Real-time reconstruction of sensitivity encoded radial magnetic resonance imaging using a graphics processing unit. IEEE Trans Med Imag 2009;28:1974-1985.
    • (2009) IEEE Trans Med Imag , vol.28 , pp. 1974-1985
    • Sørensen, T.S.1    Atkinson, D.2    Schaeffter, T.3    Hansen, M.S.4
  • 7
    • 4444260179 scopus 로고    scopus 로고
    • Comparison of gridding- And convolution-based iterative reconstruction algorithms for sensitivity-encoded non-cartesian acquisition
    • Eggers H, Boernert P, Boesiger P. Comparison of gridding- and convolution-based iterative reconstruction algorithms for sensitivity-encoded non-cartesian acquisition. In Proceedings of the ISMRM 10th Annual Meeting, Honolulu, 2002; p. 743.
    • Proceedings of the ISMRM 10th Annual Meeting, Honolulu, 2002 , pp. 743
    • Eggers, H.1    Boernert, P.2    Boesiger, P.3
  • 8
    • 74049110413 scopus 로고    scopus 로고
    • Magnetic resonance imaging in real time advances using radial FLASH
    • Zhang S, Block KT, Frahm J. Magnetic resonance imaging in real time: advances using radial FLASH. J Magn Reson Imaging 2010;31:101-109.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 101-109
    • Zhang, S.1    Block, K.T.2    Frahm, J.3
  • 13
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • DOI 10.1002/mrm.1113
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001; 59:846-852. (Pubitemid 32402027)
    • (2001) Magnetic Resonance in Medicine , vol.45 , Issue.5 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 14
    • 0032751897 scopus 로고    scopus 로고
    • Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI
    • DOI 10.1002/(SICI)1522-2594(199911)42:5<813::AID-MRM1>3.0.CO;2-S
    • Madore B, Glover GH, Pelc NJ. Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI. Magn Reson Med 1999;42:813-828. (Pubitemid 29521471)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.5 , pp. 813-828
    • Madore, B.1    Glover, G.H.2    Pelc, N.J.3
  • 15
    • 0242385483 scopus 로고    scopus 로고
    • K-t BLAST and k-t SENSE: Dynamic MRI with High Frame Rate Exploiting Spatiotemporal Correlations
    • DOI 10.1002/mrm.10611
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042. (Pubitemid 37356583)
    • (2003) Magnetic Resonance in Medicine , vol.50 , Issue.5 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 16
    • 34248230856 scopus 로고    scopus 로고
    • Improving k-t SENSE by adaptive regularization
    • DOI 10.1002/mrm.21203
    • Xu D, King KF, Liang Z-P. Improving k-t SENSE by adaptive regularization. Magn Reson Med 2007;57:918-930. (Pubitemid 46709412)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.5 , pp. 918-930
    • Xu, D.1    King, K.F.2    Liang, Z.-P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.