-
1
-
-
0034597889
-
Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis
-
Koster R, Vieluf D, Kiehn M, Sommerauer M, Kahler J, Baldus S, Meinertz T, Hamm CW,. Nickel and molybdenum contact allergies in patients with coronary in-stent restenosis. Lancet 2000; 356: 1895-1897.
-
(2000)
Lancet
, vol.356
, pp. 1895-1897
-
-
Koster, R.1
Vieluf, D.2
Kiehn, M.3
Sommerauer, M.4
Kahler, J.5
Baldus, S.6
Meinertz, T.7
Hamm, C.W.8
-
2
-
-
0035806921
-
Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model
-
Suzuki T, Kopia G, Hayashi S, Bailey LR, Llanos G, Wilensky R, Klugherz BD, Papandreou G, Narayan P, Leon MB, Yeung AC, Tio F, Tsao PS, Falotico R, Carter AJ,. Stent-based delivery of sirolimus reduces neointimal formation in a porcine coronary model. Circulation 2001; 104: 1188-1193.
-
(2001)
Circulation
, vol.104
, pp. 1188-1193
-
-
Suzuki, T.1
Kopia, G.2
Hayashi, S.3
Bailey, L.R.4
Llanos, G.5
Wilensky, R.6
Klugherz, B.D.7
Papandreou, G.8
Narayan, P.9
Leon, M.B.10
Yeung, A.C.11
Tio, F.12
Tsao, P.S.13
Falotico, R.14
Carter, A.J.15
-
3
-
-
0029761378
-
Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries
-
van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruys PW, Holmes DR, Jr, Ellis SG, Topol EJ,. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996; 94: 1690-1697.
-
(1996)
Circulation
, vol.94
, pp. 1690-1697
-
-
Van Der Giessen, W.J.1
Lincoff, A.M.2
Schwartz, R.S.3
Van Beusekom, H.M.4
Serruys, P.W.5
Holmes, Jr.D.R.6
Ellis, S.G.7
Topol, E.J.8
-
4
-
-
13844308657
-
Drug-eluting stents: Results, promises and problems
-
van der Hoeven BL, Pires NM, Warda HM, Oemrawsingh PV, van Vlijmen BJ, Quax PH, Schalij MJ, van der Wall EE, Jukema JW,. Drug-eluting stents: Results, promises and problems. Int J Cardiol 2005; 99: 9-17.
-
(2005)
Int J Cardiol
, vol.99
, pp. 9-17
-
-
Van Der Hoeven, B.L.1
Pires, N.M.2
Warda, H.M.3
Oemrawsingh, P.V.4
Van Vlijmen, B.J.5
Quax, P.H.6
Schalij, M.J.7
Van Der Wall, E.E.8
Jukema, J.W.9
-
5
-
-
33745233024
-
Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk
-
Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R,. Pathology of drug-eluting stents in humans: Delayed healing and late thrombotic risk. J Am Coll Cardiol 2006; 48: 193-202.
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 193-202
-
-
Joner, M.1
Finn, A.V.2
Farb, A.3
Mont, E.K.4
Kolodgie, F.D.5
Ladich, E.6
Kutys, R.7
Skorija, K.8
Gold, H.K.9
Virmani, R.10
-
6
-
-
33846119664
-
Local vascular toxicokinetics of stent-based drug delivery
-
Tesfamariam B,. Local vascular toxicokinetics of stent-based drug delivery. Toxicol Lett 2007; 168: 93-102.
-
(2007)
Toxicol Lett
, vol.168
, pp. 93-102
-
-
Tesfamariam, B.1
-
7
-
-
29344439392
-
Allergic reactions after the implantation of drug-eluting stents: Is it the pill or the polymer?
-
Azarbal B, Currier JW,. Allergic reactions after the implantation of drug-eluting stents: Is it the pill or the polymer? J Am Coll Cardiol 2006; 47: 182-183.
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 182-183
-
-
Azarbal, B.1
Currier, J.W.2
-
8
-
-
34548766073
-
Coronary stents, hypersensitivity reactions, and the Kounis syndrome
-
Kounis NG, Hahalis G, Theoharides TC,. Coronary stents, hypersensitivity reactions, and the Kounis syndrome. J Interv Cardiol 2007; 20: 314-323.
-
(2007)
J Interv Cardiol
, vol.20
, pp. 314-323
-
-
Kounis, N.G.1
Hahalis, G.2
Theoharides, T.C.3
-
9
-
-
29344432871
-
Hypersensitivity cases associated with drug-eluting coronary stents: A review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project
-
Nebeker JR, Virmani R, Bennett CL, Hoffman JM, Samore MH, Alvarez J, Davidson CJ, McKoy JM, Raisch DW, Whisenant BK, Yarnold PR, Belknap SM, West DP, Gage JE, Morse RE, Gligoric G, Davidson L, Feldman MD,. Hypersensitivity cases associated with drug-eluting coronary stents: A review of available cases from the Research on Adverse Drug Events and Reports (RADAR) project. J Am Coll Cardiol 2006; 47: 175-181.
-
(2006)
J Am Coll Cardiol
, vol.47
, pp. 175-181
-
-
Nebeker, J.R.1
Virmani, R.2
Bennett, C.L.3
Hoffman, J.M.4
Samore, M.H.5
Alvarez, J.6
Davidson, C.J.7
McKoy, J.M.8
Raisch, D.W.9
Whisenant, B.K.10
Yarnold, P.R.11
Belknap, S.M.12
West, D.P.13
Gage, J.E.14
Morse, R.E.15
Gligoric, G.16
Davidson, L.17
Feldman, M.D.18
-
10
-
-
34248643139
-
Drug delivery via nano-, micro and macroporous coronary stent surfaces
-
Tsujino I, Ako J, Honda Y, Fitzgerald PJ,. Drug delivery via nano-, micro and macroporous coronary stent surfaces. Expert Opin Drug Deliv 2007; 4: 287-295.
-
(2007)
Expert Opin Drug Deliv
, vol.4
, pp. 287-295
-
-
Tsujino, I.1
Ako, J.2
Honda, Y.3
Fitzgerald, P.J.4
-
11
-
-
30944449829
-
The potential of biocompatible metallic stents and preventing restenosis
-
Kathuria YP,. The potential of biocompatible metallic stents and preventing restenosis. Mater Sci Eng A 2006; 417: 40-48.
-
(2006)
Mater Sci Eng A
, vol.417
, pp. 40-48
-
-
Kathuria, Y.P.1
-
12
-
-
33846171184
-
Coronary stents: A materials perspective
-
Mani G, Feldman MD, Patel D, Agrawal CM,. Coronary stents: A materials perspective. Biomaterials 2007; 28: 1689-1710.
-
(2007)
Biomaterials
, vol.28
, pp. 1689-1710
-
-
Mani, G.1
Feldman, M.D.2
Patel, D.3
Agrawal, C.M.4
-
13
-
-
37349116202
-
Electrochemical formation of highly pitting resistant films on a biomedical grade 316LVM stainess steel surface
-
Shahryary A, Omanovich S, Szpunar JA,. Electrochemical formation of highly pitting resistant films on a biomedical grade 316LVM stainess steel surface. Mater Sci Eng C 2008; 28: 94-106.
-
(2008)
Mater Sci Eng C
, vol.28
, pp. 94-106
-
-
Shahryary, A.1
Omanovich, S.2
Szpunar, J.A.3
-
14
-
-
33847197914
-
Stability of passivated 316L stainless steel oxide films for cardiovascular stents
-
Shih CC, Shih CM, Chou KY, Lin SJ, Su YY,. Stability of passivated 316L stainless steel oxide films for cardiovascular stents. J Biomed Mater Res A 2007; 80A: 861-873.
-
(2007)
J Biomed Mater Res A
, vol.80 A
, pp. 861-873
-
-
Shih, C.C.1
Shih, C.M.2
Chou, K.Y.3
Lin, S.J.4
Su, Y.Y.5
-
15
-
-
0242458484
-
Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications
-
Shih CC, Shih CM, Su YY, Su LHJ, Chang MS, Lin SJ,. Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications. Corros Sci 2004; 46: 427-441.
-
(2004)
Corros Sci
, vol.46
, pp. 427-441
-
-
Shih, C.C.1
Shih, C.M.2
Su, Y.Y.3
Su, L.H.J.4
Chang, M.S.5
Lin, S.J.6
-
16
-
-
0037852924
-
Protective carbon layer for chemical corrosion of stainless steel
-
Mansano RD, Massi M, Mousinho AP, Zambom LS, Neto LG,. Protective carbon layer for chemical corrosion of stainless steel. Diamond Relat Mater 2003; 12: 749-752.
-
(2003)
Diamond Relat Mater
, vol.12
, pp. 749-752
-
-
Mansano, R.D.1
Massi, M.2
Mousinho, A.P.3
Zambom, L.S.4
Neto, L.G.5
-
17
-
-
0034666723
-
In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity
-
Gutensohn K, Beythien C, Bau J, Fenner T, Grewe P, Koester R, Padmanaban K, Kuehnl P,. In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res 2000; 99: 577-585.
-
(2000)
Thromb Res
, vol.99
, pp. 577-585
-
-
Gutensohn, K.1
Beythien, C.2
Bau, J.3
Fenner, T.4
Grewe, P.5
Koester, R.6
Padmanaban, K.7
Kuehnl, P.8
-
18
-
-
22844451688
-
Mechanical stability, corrosion performance and bioresponse of amorphous diamond-like carbon for medical stents and guidewires
-
Maguire PD, McLaughlin JA, Okpalugo TIT, Lemoine P, Papakonstantinou P, McAdams ET, Needham M, Ogwu AA, Ball M, Abbas GA,. Mechanical stability, corrosion performance and bioresponse of amorphous diamond-like carbon for medical stents and guidewires. Diamond Relat Mater 2005; 14: 1277-1288.
-
(2005)
Diamond Relat Mater
, vol.14
, pp. 1277-1288
-
-
Maguire, P.D.1
McLaughlin, J.A.2
Okpalugo, T.I.T.3
Lemoine, P.4
Papakonstantinou, P.5
McAdams, E.T.6
Needham, M.7
Ogwu, A.A.8
Ball, M.9
Abbas, G.A.10
-
19
-
-
10744229783
-
Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease
-
Airoldi F, Colombo A, Tavano D, Stankovic G, Klugmann S, Paolillo V, Bonizzoni E, Briguori C, Carlino M, Montorfano M Liistro F, Castelli A, Ferrari A, Sgura F, Di Mario C,. Comparison of diamond-like carbon-coated stents versus uncoated stainless steel stents in coronary artery disease. Am J Cardiol 2004; 93: 474-477.
-
(2004)
Am J Cardiol
, vol.93
, pp. 474-477
-
-
Airoldi, F.1
Colombo, A.2
Tavano, D.3
Stankovic, G.4
Klugmann, S.5
Paolillo, V.6
Bonizzoni, E.7
Briguori, C.8
Carlino, M.9
Montorfano Liistro M, F.10
Castelli, A.11
Ferrari, A.12
Sgura, F.13
Di Mario, C.14
-
20
-
-
34548751241
-
Does Carbofilm coating affect in-stent intimal proliferation? A randomized trial comparing Rx multi-link penta and tecnic carbostent stents: SIROCCO trial
-
Carrie D, Lefevre T, Cherradi R, Dumas P, Elbaz M, Finet G, Puel J, Morice MC,. Does Carbofilm coating affect in-stent intimal proliferation? A randomized trial comparing Rx multi-link penta and tecnic carbostent stents: SIROCCO trial. J Interv Cardiol 2007; 20: 381-388.
-
(2007)
J Interv Cardiol
, vol.20
, pp. 381-388
-
-
Carrie, D.1
Lefevre, T.2
Cherradi, R.3
Dumas, P.4
Elbaz, M.5
Finet, G.6
Puel, J.7
Morice, M.C.8
-
21
-
-
20044374844
-
Randomized comparison of carbon ion-implanted stent versus bare metal stent in coronary artery disease: The Asian Pacific Multicenter Arthos Stent Study (PASS) trial
-
Kim YH, Lee CW, Hong MK, Park SW, Tahk SJ, Yang JY, Saito S, Santoso T, Quan L, Ge J, Weissman NJ, Lansky AJ, Mintz GS, Park SJ,. Randomized comparison of carbon ion-implanted stent versus bare metal stent in coronary artery disease: The Asian Pacific Multicenter Arthos Stent Study (PASS) trial. Am Heart J 2005; 149: 336-341.
-
(2005)
Am Heart J
, vol.149
, pp. 336-341
-
-
Kim, Y.H.1
Lee, C.W.2
Hong, M.K.3
Park, S.W.4
Tahk, S.J.5
Yang, J.Y.6
Saito, S.7
Santoso, T.8
Quan, L.9
Ge, J.10
Weissman, N.J.11
Lansky, A.J.12
Mintz, G.S.13
Park, S.J.14
-
22
-
-
4244151667
-
The tribological properties of MoS2/metal composite coatings deposited by closed field magnetron sputtering
-
Teer DG, Hampshire J, Fox V, Bellido-Gonzalez V,. The tribological properties of MoS2/metal composite coatings deposited by closed field magnetron sputtering. Surf Coat Technol 1997; 94/95: 572-577.
-
(1997)
Surf Coat Technol
, vol.9495
, pp. 572-577
-
-
Teer, D.G.1
Hampshire, J.2
Fox, V.3
Bellido-Gonzalez, V.4
-
23
-
-
0034696091
-
Deposition and tribological behavior of sputtered carbon hard coatings
-
Yang S, Camino D, Jones AHS, Teer DG,. Deposition and tribological behavior of sputtered carbon hard coatings. Surf Coat Technol 2000; 124: 110-116.
-
(2000)
Surf Coat Technol
, vol.124
, pp. 110-116
-
-
Yang, S.1
Camino, D.2
Jones, A.H.S.3
Teer, D.G.4
-
24
-
-
7444239033
-
Tribological properties of grafite-like and diamond-like carbon coatings
-
Field SK, Jarratt M, Teer DG,. Tribological properties of grafite-like and diamond-like carbon coatings. Tribol Int 2004; 37: 949-956.
-
(2004)
Tribol Int
, vol.37
, pp. 949-956
-
-
Field, S.K.1
Jarratt, M.2
Teer, D.G.3
-
25
-
-
0028519709
-
Studies on the standardization of cytotoxicity tests and new standard reference materials useful for evaluating the safety of biomaterials
-
Tsuchiya T,. Studies on the standardization of cytotoxicity tests and new standard reference materials useful for evaluating the safety of biomaterials. J Biomater Appl 1994; 9: 138-157.
-
(1994)
J Biomater Appl
, vol.9
, pp. 138-157
-
-
Tsuchiya, T.1
-
26
-
-
9144226905
-
Fibrinogen adsorption and platelet adhesion to metal and carbon coatings
-
Mikhalovska LI, Santin M, Denyer SP, Lloyd AW, Teer DG, Field S, Mikhalovsky SV,. Fibrinogen adsorption and platelet adhesion to metal and carbon coatings. Thromb Haemost 2004; 92: 1032-1039.
-
(2004)
Thromb Haemost
, vol.92
, pp. 1032-1039
-
-
Mikhalovska, L.I.1
Santin, M.2
Denyer, S.P.3
Lloyd, A.W.4
Teer, D.G.5
Field, S.6
Mikhalovsky, S.V.7
-
28
-
-
78651086424
-
Changes in the rabbit's aorta wall after implantation of the stents with different coatings
-
Lazarenko ON, Sergienko OV, Alekseyeva TA, Oshkaderov SP, Skiba IA, Shekera OV, Denyer SP, Mikhalovsky SV,. Changes in the rabbit's aorta wall after implantation of the stents with different coatings. Ukrainian Cardiol J 2003; 1: 96-98.
-
(2003)
Ukrainian Cardiol J
, vol.1
, pp. 96-98
-
-
Lazarenko, O.N.1
Sergienko, O.V.2
Alekseyeva, T.A.3
Oshkaderov, S.P.4
Skiba, I.A.5
Shekera, O.V.6
Denyer, S.P.7
Mikhalovsky, S.V.8
-
29
-
-
0031156796
-
Vascular endothelial cadherin (VE-cadherin): Cloning and role in endothelial cell-cell adhesion
-
Ali J, Liao F, Martens E, Muller WA,. Vascular endothelial cadherin (VE-cadherin): Cloning and role in endothelial cell-cell adhesion. Microcirculation 1997; 4: 267-277.
-
(1997)
Microcirculation
, vol.4
, pp. 267-277
-
-
Ali, J.1
Liao, F.2
Martens, E.3
Muller, W.A.4
-
31
-
-
34249744409
-
Hemocompatibility of high strength oxide ceramic materials: An in vitro study
-
Fischer H, Luk M, Oedekoven B, Telle R, Mottaghy K,. Hemocompatibility of high strength oxide ceramic materials: An in vitro study. J Biomed Mater Res A 2007; 81A: 982-986.
-
(2007)
J Biomed Mater Res A
, vol.81 A
, pp. 982-986
-
-
Fischer, H.1
Luk, M.2
Oedekoven, B.3
Telle, R.4
Mottaghy, K.5
-
32
-
-
0034333612
-
Protein adsorption and platelet attachment and activation, on TiN, TiC, and DLC coatings on titanium for cardiovascular applications
-
Jones MI, McColl IR, Grant DM, Parker KG, Parker TL,. Protein adsorption and platelet attachment and activation, on TiN, TiC, and DLC coatings on titanium for cardiovascular applications. J Biomed Mater Res 2000; 52: 413-421.
-
(2000)
J Biomed Mater Res
, vol.52
, pp. 413-421
-
-
Jones, M.I.1
McColl, I.R.2
Grant, D.M.3
Parker, K.G.4
Parker, T.L.5
-
33
-
-
0018866938
-
Interaction of fibrinogen with its platelet receptor as part of a multistep reaction in ADP-induced platelet aggregation
-
Marguerie GA, Edgington TS, Plow EF,. Interaction of fibrinogen with its platelet receptor as part of a multistep reaction in ADP-induced platelet aggregation. J Biol Chem 1980; 255: 154-161.
-
(1980)
J Biol Chem
, vol.255
, pp. 154-161
-
-
Marguerie, G.A.1
Edgington, T.S.2
Plow, E.F.3
-
34
-
-
0034175826
-
Clinical and angiographic outcome after coronary arterial stenting with the carbostent
-
Antoniucci D, Bartorelli A, Valenti R, Montorsi P, Santoro GM, Fabbiocchi F, Bolognese L, Loaldi A, Trapani M, Trabattoni D, Moschi G, Galli S,. Clinical and angiographic outcome after coronary arterial stenting with the carbostent. Am J Cardiol 2000; 85: 821-825.
-
(2000)
Am J Cardiol
, vol.85
, pp. 821-825
-
-
Antoniucci, D.1
Bartorelli, A.2
Valenti, R.3
Montorsi, P.4
Santoro, G.M.5
Fabbiocchi, F.6
Bolognese, L.7
Loaldi, A.8
Trapani, M.9
Trabattoni, D.10
Moschi, G.11
Galli, S.12
-
35
-
-
38049078734
-
Prospective randomized study of the restenotic process in small coronary arteries using a Carbofilm coated stent in comparison with plain old balloon angioplasty: A multicenter study
-
Braun P,. Prospective randomized study of the restenotic process in small coronary arteries using a Carbofilm coated stent in comparison with plain old balloon angioplasty: A multicenter study. Catheter Cardiovasc Interv 2007; 70: 920-927.
-
(2007)
Catheter Cardiovasc Interv
, vol.70
, pp. 920-927
-
-
Braun, P.1
-
36
-
-
34247573098
-
Success, safety, and efficacy of implantation of diamond-like carbon-coated stents
-
Salahas A, Vrahatis A, Karabinos I, Antonellis I, Ifantis G, Gavaliatsis I, Anthopoulos P, Tavernarakis A,. Success, safety, and efficacy of implantation of diamond-like carbon-coated stents. Angiology 2007; 58: 203-210.
-
(2007)
Angiology
, vol.58
, pp. 203-210
-
-
Salahas, A.1
Vrahatis, A.2
Karabinos, I.3
Antonellis, I.4
Ifantis, G.5
Gavaliatsis, I.6
Anthopoulos, P.7
Tavernarakis, A.8
-
37
-
-
2542419959
-
Comparison of early and late results of a Carbofilm-coated stent versus a pure high-grade stainless steel stent (the Carbostent-Trial)
-
Sick PB, Gelbrich G, Kalnins U, Erglis A, Bonan R, Aengevaeren W, Elsner D, Lauer B, Woinke M, Brosteanu O, Schuler G,. Comparison of early and late results of a Carbofilm-coated stent versus a pure high-grade stainless steel stent (the Carbostent-Trial). Am J Cardiol 2004; 93: 1351-1356.
-
(2004)
Am J Cardiol
, vol.93
, pp. 1351-1356
-
-
Sick, P.B.1
Gelbrich, G.2
Kalnins, U.3
Erglis, A.4
Bonan, R.5
Aengevaeren, W.6
Elsner, D.7
Lauer, B.8
Woinke, M.9
Brosteanu, O.10
Schuler, G.11
-
38
-
-
43549121705
-
Outcomes of the tacrolimus drug-eluting Janus stent: A prospective two-centre registry in high-risk patients
-
Romagnoli E, Leone AM, Burzotta F, Trani C, Angeloni G, Materazzo G, Niccoli G, Maria de V, Perfetti M, Mazzari MA, Mongiardo R, Rebuzzi AG, Schiavoni G, Crea F,. Outcomes of the tacrolimus drug-eluting Janus stent: A prospective two-centre registry in high-risk patients. J Cardiovasc Med (Hagerstown) 2008; 9: 589-594.
-
(2008)
J Cardiovasc Med (Hagerstown)
, vol.9
, pp. 589-594
-
-
Romagnoli, E.1
Leone, A.M.2
Burzotta, F.3
Trani, C.4
Angeloni, G.5
Materazzo, G.6
Niccoli, G.7
De, M.V.8
Perfetti, M.9
Mazzari, M.A.10
Mongiardo, R.11
Rebuzzi, A.G.12
Schiavoni, G.13
Crea, F.14
-
39
-
-
67649971359
-
Effect of stress on the passivation of Si-DLC coating as stent materials in simulated body environment
-
Nam ND, Lee SH, Kim JG, Yi JW, Lee KR,. Effect of stress on the passivation of Si-DLC coating as stent materials in simulated body environment. Diamond Relat Mater 2009; 18: 1145-1151.
-
(2009)
Diamond Relat Mater
, vol.18
, pp. 1145-1151
-
-
Nam, N.D.1
Lee, S.H.2
Kim, J.G.3
Yi, J.W.4
Lee, K.R.5
|