메뉴 건너뛰기




Volumn 80, Issue 4, 2007, Pages 861-873

Stability of passivated 316L stainless steel oxide films for cardiovascular stents

Author keywords

316L stainless steel stent; Hydrated and hydrolyated oxides; Inflammation; Neointima; Passivated; Thrombosis

Indexed keywords

CARDIOLOGY; CHARGED PARTICLES; HYDROLYSIS; PHYSIOLOGY; STAINLESS STEEL;

EID: 33847197914     PISSN: 15493296     EISSN: 15524965     Source Type: Journal    
DOI: 10.1002/jbm.a.30915     Document Type: Article
Times cited : (24)

References (56)
  • 3
    • 12844280016 scopus 로고    scopus 로고
    • Surface conditioning of 316LVM slotted tube cardiovascular stents
    • Raval A, Chousbey A, Engineer C, Kothwala D. Surface conditioning of 316LVM slotted tube cardiovascular stents. J Biomater Appl 2005;19:197-213.
    • (2005) J Biomater Appl , vol.19 , pp. 197-213
    • Raval, A.1    Chousbey, A.2    Engineer, C.3    Kothwala, D.4
  • 5
    • 3342989739 scopus 로고    scopus 로고
    • Environment influences on endocascular stent platelet reactivity: An in vitro comparison of stainless steel and gold surfaces
    • Kolandaivelu K, Edelman ER. Environment influences on endocascular stent platelet reactivity: An in vitro comparison of stainless steel and gold surfaces. J Biomed Mater Res A 2004;70:186-193.
    • (2004) J Biomed Mater Res A , vol.70 , pp. 186-193
    • Kolandaivelu, K.1    Edelman, E.R.2
  • 10
    • 0036183585 scopus 로고    scopus 로고
    • Corrosion and permanent fracture resistance of coated and conventional orthodontic wires
    • Neumann P, Bourauel C, Jager A. Corrosion and permanent fracture resistance of coated and conventional orthodontic wires. J Mater Sci: Mater Med 2002;13:141-147.
    • (2002) J Mater Sci: Mater Med , vol.13 , pp. 141-147
    • Neumann, P.1    Bourauel, C.2    Jager, A.3
  • 11
    • 4344607831 scopus 로고    scopus 로고
    • In vitro corrosion characteristics of commercially available orthodontic wires
    • Yonekura Y, Endo K, Iijima M, Ohno H, Mizguchi I. In vitro corrosion characteristics of commercially available orthodontic wires. Dent Mater J 2004;23:197-202.
    • (2004) Dent Mater J , vol.23 , pp. 197-202
    • Yonekura, Y.1    Endo, K.2    Iijima, M.3    Ohno, H.4    Mizguchi, I.5
  • 13
    • 0033208653 scopus 로고    scopus 로고
    • An investigation of the effects of polishing on surface hardness and corrosion of orthodontic archwires
    • Hunt NP, Cunningham SJ, Golden CG, Sheriff M. An investigation of the effects of polishing on surface hardness and corrosion of orthodontic archwires. Angle Orthod 1999;69:433-440.
    • (1999) Angle Orthod , vol.69 , pp. 433-440
    • Hunt, N.P.1    Cunningham, S.J.2    Golden, C.G.3    Sheriff, M.4
  • 14
    • 0037276254 scopus 로고    scopus 로고
    • Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel
    • Kraft CN, Diedrich O, Burian B, Schmitt O, Wimmer MA. Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel. J Bone Joint Surg Br 2003;85:133-141.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 133-141
    • Kraft, C.N.1    Diedrich, O.2    Burian, B.3    Schmitt, O.4    Wimmer, M.A.5
  • 15
    • 0001251725 scopus 로고
    • Characteristics of trace ions released from embedded metal implants in the rabbit
    • Ferguson AB, Laing PG, Hodges ES. Characteristics of trace ions released from embedded metal implants in the rabbit. J Bone Joint Surg Am 1962;44:323-336.
    • (1962) J Bone Joint Surg Am , vol.44 , pp. 323-336
    • Ferguson, A.B.1    Laing, P.G.2    Hodges, E.S.3
  • 16
    • 0035256068 scopus 로고    scopus 로고
    • Corrosion behavior of a welded stainless steel orthopedic implant
    • Reclaru L, Lerf R, Eschler PY, Meyer JM. Corrosion behavior of a welded stainless steel orthopedic implant. Biomaterials 2001;22:269-279.
    • (2001) Biomaterials , vol.22 , pp. 269-279
    • Reclaru, L.1    Lerf, R.2    Eschler, P.Y.3    Meyer, J.M.4
  • 17
    • 0035814239 scopus 로고    scopus 로고
    • Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: A comparative in vivo study
    • Kraft CN, Burian B, Perlick L, Wimmer MA, Wallny T, Schmitt O, Diedrich O. Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: A comparative in vivo study. J Biomed Mater Res 2001;57:404-412.
    • (2001) J Biomed Mater Res , vol.57 , pp. 404-412
    • Kraft, C.N.1    Burian, B.2    Perlick, L.3    Wimmer, M.A.4    Wallny, T.5    Schmitt, O.6    Diedrich, O.7
  • 21
    • 0019067101 scopus 로고
    • The influence of electropolishing on the corrosion resistance of 316L stainless steel
    • Sutow EJ. The influence of electropolishing on the corrosion resistance of 316L stainless steel. J Biomed Mater Res 1980;14:587-595.
    • (1980) J Biomed Mater Res , vol.14 , pp. 587-595
    • Sutow, E.J.1
  • 22
    • 0142217430 scopus 로고    scopus 로고
    • Characterization of thrombogenic potential of surface oxides of stainless steel for implant purposes
    • Shih CC, Shih CM, Su YY, Chang MS, Lin SJ. Characterization of thrombogenic potential of surface oxides of stainless steel for implant purposes. Appl Surf Sci 2003;219:347-362.
    • (2003) Appl Surf Sci , vol.219 , pp. 347-362
    • Shih, C.C.1    Shih, C.M.2    Su, Y.Y.3    Chang, M.S.4    Lin, S.J.5
  • 23
    • 0347384082 scopus 로고    scopus 로고
    • Impact on the thrombogenicity of surface oxide properties of 316L stainless steel for biomedical applications
    • Shih CC, Shih CM, Su YY, Lin SJ. Impact on the thrombogenicity of surface oxide properties of 316L stainless steel for biomedical applications. J Biomed Mater Res A 2003;67:1320-1328.
    • (2003) J Biomed Mater Res A , vol.67 , pp. 1320-1328
    • Shih, C.C.1    Shih, C.M.2    Su, Y.Y.3    Lin, S.J.4
  • 24
    • 0242458484 scopus 로고    scopus 로고
    • Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications
    • Shih CC, Shih CM, Su YY, Su LWJ, Chang MS, Lin SJ. Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications. Corros Sci 2004;46:427-441.
    • (2004) Corros Sci , vol.46 , pp. 427-441
    • Shih, C.C.1    Shih, C.M.2    Su, Y.Y.3    Su, L.W.J.4    Chang, M.S.5    Lin, S.J.6
  • 25
    • 0034333624 scopus 로고    scopus 로고
    • Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide
    • Shih CC, Lin SJ, Chung KH, Chen YL, Su YY. Increased corrosion resistance of stent materials by converting current surface film of polycrystalline oxide into amorphous oxide. J Biomed Mater Res 2000;52:323-332.
    • (2000) J Biomed Mater Res , vol.52 , pp. 323-332
    • Shih, C.C.1    Lin, S.J.2    Chung, K.H.3    Chen, Y.L.4    Su, Y.Y.5
  • 26
    • 0034774586 scopus 로고    scopus 로고
    • Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless steel wire
    • Shih CC, Shih CM, Chen YL, Su YY, Shih JS, Kwok CF, Lin SJ. Growth inhibition of cultured smooth muscle cells by corrosion products of 316L stainless steel wire. J Biomed Mater Res 2001;57:200-207.
    • (2001) J Biomed Mater Res , vol.57 , pp. 200-207
    • Shih, C.C.1    Shih, C.M.2    Chen, Y.L.3    Su, Y.Y.4    Shih, J.S.5    Kwok, C.F.6    Lin, S.J.7
  • 28
    • 12444304374 scopus 로고
    • Application of electrochemical impedance spectroscopy (EIS) to the evaluation of the corrosion behavior of implant material
    • Mansfeld F, Lee CC, Kovacs P. Application of electrochemical impedance spectroscopy (EIS) to the evaluation of the corrosion behavior of implant material. Proc Electrochem Soc 1994;94:59-72.
    • (1994) Proc Electrochem Soc , vol.94 , pp. 59-72
    • Mansfeld, F.1    Lee, C.C.2    Kovacs, P.3
  • 29
    • 0001694661 scopus 로고
    • Passive film of 18-8 stainless steel structure and its function
    • Okamoto G. Passive film of 18-8 stainless steel structure and its function. Corros Sci 1973;13:471-489.
    • (1973) Corros Sci , vol.13 , pp. 471-489
    • Okamoto, G.1
  • 30
    • 0018679370 scopus 로고
    • The inhibitive action of bound water in the passive film of stainless steel against chloride corrosion
    • Saito H, Shibata T, Okamoto G. The inhibitive action of bound water in the passive film of stainless steel against chloride corrosion. Corros Sci 1979;19:693-708.
    • (1979) Corros Sci , vol.19 , pp. 693-708
    • Saito, H.1    Shibata, T.2    Okamoto, G.3
  • 31
    • 0017546211 scopus 로고
    • The electrochemical aspects of the thrombogenicity of a material
    • Baurschmidt P, Schaldach M. The electrochemical aspects of the thrombogenicity of a material. J Bioeng 1977;1:261-278.
    • (1977) J Bioeng , vol.1 , pp. 261-278
    • Baurschmidt, P.1    Schaldach, M.2
  • 32
    • 3543005819 scopus 로고    scopus 로고
    • Development of a new hybrid coronary stent design with optimized biocompatible properties
    • Wise DL, Trantolo DJ, Lewandrowski KU, Gresser JD, Cattaneo MV, Yaszemski MJ, editors, New Jersey: Humana Press;
    • Bolz A, Harder C, Unverdorben M, Schaldach M. Development of a new hybrid coronary stent design with optimized biocompatible properties. In: Wise DL, Trantolo DJ, Lewandrowski KU, Gresser JD, Cattaneo MV, Yaszemski MJ, editors. Biomaterials Engineering and Device, Vol. 1. New Jersey: Humana Press; 2000, p 201-222.
    • (2000) Biomaterials Engineering and Device , vol.1 , pp. 201-222
    • Bolz, A.1    Harder, C.2    Unverdorben, M.3    Schaldach, M.4
  • 34
    • 33748425985 scopus 로고    scopus 로고
    • Inflammation and restenosis after percutaneous coronary interventions
    • Toutouzas K, Colombo A, Stefanadis C. Inflammation and restenosis after percutaneous coronary interventions. Eur heart J 2004;3:1-9.
    • (2004) Eur heart J , vol.3 , pp. 1-9
    • Toutouzas, K.1    Colombo, A.2    Stefanadis, C.3
  • 35
    • 9444243222 scopus 로고    scopus 로고
    • Metal ion release from metal implants
    • Hanawa T. Metal ion release from metal implants. Mater Sci Eng C 2004;24:745-752.
    • (2004) Mater Sci Eng C , vol.24 , pp. 745-752
    • Hanawa, T.1
  • 36
    • 0036989871 scopus 로고    scopus 로고
    • Contact allergies to metal components of the 316L steel in patients with coronary heart disease
    • Hillen U, Haude M, Erbel R, Good M. Contact allergies to metal components of the 316L steel in patients with coronary heart disease. Mat-wiss U Werkstofftech 2002;33:747-750.
    • (2002) Mat-wiss U Werkstofftech , vol.33 , pp. 747-750
    • Hillen, U.1    Haude, M.2    Erbel, R.3    Good, M.4
  • 37
    • 7044235969 scopus 로고    scopus 로고
    • Metal allergy to implanted orthopedic prosthesis after postoperative Staphylococcus aureus infection
    • Oiso O, Komeda T, Fukai K, Ishi M, Hirai T, Kugai A. Metal allergy to implanted orthopedic prosthesis after postoperative Staphylococcus aureus infection. Contact Dermatitis 2004;51:151-153.
    • (2004) Contact Dermatitis , vol.51 , pp. 151-153
    • Oiso, O.1    Komeda, T.2    Fukai, K.3    Ishi, M.4    Hirai, T.5    Kugai, A.6
  • 38
    • 0347064238 scopus 로고    scopus 로고
    • Nickel allergy to the percutaneous patent foramen ovale occluder and subsequent systemic nickel allergy
    • Dasika UK, Kanter KR, Vincent R. Nickel allergy to the percutaneous patent foramen ovale occluder and subsequent systemic nickel allergy. J Throac Cardiovasc Surg 2003;126:2112.
    • (2003) J Throac Cardiovasc Surg , vol.126 , pp. 2112
    • Dasika, U.K.1    Kanter, K.R.2    Vincent, R.3
  • 41
    • 0033040265 scopus 로고    scopus 로고
    • Electrostatic interactions during activation of coagulation factor IX via the tissue factor pathway: Effect of univalent salts
    • McGee MP, Teuschler H, Liang J. Electrostatic interactions during activation of coagulation factor IX via the tissue factor pathway: Effect of univalent salts. Biochim Biophys Acta 1999;1453:239-253.
    • (1999) Biochim Biophys Acta , vol.1453 , pp. 239-253
    • McGee, M.P.1    Teuschler, H.2    Liang, J.3
  • 42
    • 2442501409 scopus 로고    scopus 로고
    • Biomater-associated thrombosis: Roles of coagulation factors, complement, platelets and leukocytes
    • Gorbet MB, Sefton MV. Biomater-associated thrombosis: Roles of coagulation factors, complement, platelets and leukocytes. Biomaterials 2004;25:5681-5703.
    • (2004) Biomaterials , vol.25 , pp. 5681-5703
    • Gorbet, M.B.1    Sefton, M.V.2
  • 43
    • 0034666723 scopus 로고    scopus 로고
    • In-vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity
    • Gutensohn K, Beythien C, Bau J, Fenner T, Grewe P, Koester R. In-vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res 2000;99:577-585.
    • (2000) Thromb Res , vol.99 , pp. 577-585
    • Gutensohn, K.1    Beythien, C.2    Bau, J.3    Fenner, T.4    Grewe, P.5    Koester, R.6
  • 46
    • 0023723684 scopus 로고
    • Immunochemical characterization of crosslinked derivatives isolated from α chain oligomers formed during early stages of fibrin cross-linking
    • Sobel JH, Thibodeau CA, Gawinowicz Kolks MA, Canfield RE. Immunochemical characterization of crosslinked derivatives isolated from α chain oligomers formed during early stages of fibrin cross-linking. Thromb Haemost 1988;60:160-169.
    • (1988) Thromb Haemost , vol.60 , pp. 160-169
    • Sobel, J.H.1    Thibodeau, C.A.2    Gawinowicz Kolks, M.A.3    Canfield, R.E.4
  • 47
    • 0017072141 scopus 로고
    • Electrochemical features of platelet interactions
    • Seaman GV. Electrochemical features of platelet interactions. Thromb Res 1976;8:235-246.
    • (1976) Thromb Res , vol.8 , pp. 235-246
    • Seaman, G.V.1
  • 48
    • 0020001539 scopus 로고
    • α chain crossing-links of human fibrin: Purification and radioimmunoassay development for two α chain regions involved in cross-linking
    • Sobel JH, Koehn JA, Friedman R, Canfield RE. α chain crossing-links of human fibrin: Purification and radioimmunoassay development for two α chain regions involved in cross-linking. Thromb Res 1982;26:411-424.
    • (1982) Thromb Res , vol.26 , pp. 411-424
    • Sobel, J.H.1    Koehn, J.A.2    Friedman, R.3    Canfield, R.E.4
  • 49
    • 0022902732 scopus 로고
    • The release of small amounts of fibrinopeptide-B (FPB) is of critical importance for the thrombin clotting time
    • Holm B, Kierulf P, Godal HC. The release of small amounts of fibrinopeptide-B (FPB) is of critical importance for the thrombin clotting time. Thromb Res 1986;42:517-526.
    • (1986) Thromb Res , vol.42 , pp. 517-526
    • Holm, B.1    Kierulf, P.2    Godal, H.C.3
  • 51
    • 0032943419 scopus 로고    scopus 로고
    • Ability of N-containing biomedical alloys to activate monocytes and endothelial cell in vitro
    • Wataha JC, Lockwood PE, Marek M, Ghazi M. Ability of N-containing biomedical alloys to activate monocytes and endothelial cell in vitro. J Biomed Mater Res 1999;45:251-257.
    • (1999) J Biomed Mater Res , vol.45 , pp. 251-257
    • Wataha, J.C.1    Lockwood, P.E.2    Marek, M.3    Ghazi, M.4
  • 52
    • 0019017420 scopus 로고
    • Growth inhibition of cultures fibroblasts by cobalt and nickel
    • Bearden LJ, Cooke FW. Growth inhibition of cultures fibroblasts by cobalt and nickel. J Biomed Mater Res 1980;14:289-309.
    • (1980) J Biomed Mater Res , vol.14 , pp. 289-309
    • Bearden, L.J.1    Cooke, F.W.2
  • 54
    • 0343118757 scopus 로고    scopus 로고
    • Copper-induced inflammatory reactions of rate carotid arteries mimic restenosis/arteriosclerosis-like neointima formation
    • Volker W, Dorszewski A, Unruh V, Robenek H, Breithardt G, Buddecke E. Copper-induced inflammatory reactions of rate carotid arteries mimic restenosis/arteriosclerosis-like neointima formation. Atherosclerosis 1997;130:29-36.
    • (1997) Atherosclerosis , vol.130 , pp. 29-36
    • Volker, W.1    Dorszewski, A.2    Unruh, V.3    Robenek, H.4    Breithardt, G.5    Buddecke, E.6
  • 55
    • 0344211507 scopus 로고    scopus 로고
    • Evaluation of metal allergies in patients with coronary stents
    • Hillen U, Haude M, Erbel R, Goos M. Evaluation of metal allergies in patients with coronary stents. Contact Dermatitis 2002;47:353-356.
    • (2002) Contact Dermatitis , vol.47 , pp. 353-356
    • Hillen, U.1    Haude, M.2    Erbel, R.3    Goos, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.