메뉴 건너뛰기




Volumn 33, Issue 1, 2011, Pages 112-120

Evaluation of the generality and accuracy of a new mesh morphing procedure for the human femur

Author keywords

Bone biomechanics; Femur; Mesh morphing; Radial basis function; Subject specific finite element model

Indexed keywords

COMPUTATIONAL BIOMECHANICS; COMPUTED TOMOGRAPHY SCAN; FE MODEL; FE-MODELLING; FEMUR; FINITE ELEMENTS; HUMAN FEMORA; IN-VITRO; MESH MORPHING; MESH QUALITY; MORPHING; P-VALUES; PREDICTION ACCURACY; QUANTITATIVE ASSESSMENTS; RADIAL BASIS FUNCTIONS; STATISTICAL SHAPE MODELLING; SUBJECT-SPECIFIC;

EID: 78650938491     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2010.09.014     Document Type: Article
Times cited : (68)

References (41)
  • 1
    • 0346761904 scopus 로고    scopus 로고
    • Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies
    • Viceconti M., Davinelli M., Taddei F., Cappello A. Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies. J Biomech 2004, 37:1597-1605.
    • (2004) J Biomech , vol.37 , pp. 1597-1605
    • Viceconti, M.1    Davinelli, M.2    Taddei, F.3    Cappello, A.4
  • 2
    • 34247869561 scopus 로고    scopus 로고
    • Prediction of strength and strain of the proximal femur by a CT-based finite element method
    • Bessho M., Ohnishi I., Matsuyama J., Matsumoto T., Imai K., Nakamura K. Prediction of strength and strain of the proximal femur by a CT-based finite element method. J Biomech 2007, 40:1745-1753.
    • (2007) J Biomech , vol.40 , pp. 1745-1753
    • Bessho, M.1    Ohnishi, I.2    Matsuyama, J.3    Matsumoto, T.4    Imai, K.5    Nakamura, K.6
  • 3
    • 58649094180 scopus 로고    scopus 로고
    • Validation of subject-specific automated p-FE analysis of the proximal femur
    • Trabelsi N., Yosibash Z., Milgrom C. Validation of subject-specific automated p-FE analysis of the proximal femur. J Biomech 2009, 42:234-241.
    • (2009) J Biomech , vol.42 , pp. 234-241
    • Trabelsi, N.1    Yosibash, Z.2    Milgrom, C.3
  • 4
    • 34548567395 scopus 로고    scopus 로고
    • Subject-specific finite element models can accurately predict strain levels in long bones
    • Schileo E., Taddei F., Malandrino A., Cristofolini L., Viceconti M. Subject-specific finite element models can accurately predict strain levels in long bones. J Biomech 2007, 40:2982-2989.
    • (2007) J Biomech , vol.40 , pp. 2982-2989
    • Schileo, E.1    Taddei, F.2    Malandrino, A.3    Cristofolini, L.4    Viceconti, M.5
  • 5
    • 38349060664 scopus 로고    scopus 로고
    • Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro
    • Schileo E., Taddei F., Cristofolini L., Viceconti M. Subject-specific finite element models implementing a maximum principal strain criterion are able to estimate failure risk and fracture location on human femurs tested in vitro. J Biomech 2008, 41:356-367.
    • (2008) J Biomech , vol.41 , pp. 356-367
    • Schileo, E.1    Taddei, F.2    Cristofolini, L.3    Viceconti, M.4
  • 6
    • 76749151340 scopus 로고    scopus 로고
    • Development of subject-specific and statistical shape models of the knee using an efficient segmentation and mesh-morphing approach
    • Baldwin M.A., Langenderfer J.E., Rullkoetter P.J., Laz P.J. Development of subject-specific and statistical shape models of the knee using an efficient segmentation and mesh-morphing approach. Comput Methods Programs Biomed 2009, 97:232-240.
    • (2009) Comput Methods Programs Biomed , vol.97 , pp. 232-240
    • Baldwin, M.A.1    Langenderfer, J.E.2    Rullkoetter, P.J.3    Laz, P.J.4
  • 7
    • 74249111145 scopus 로고    scopus 로고
    • Mesh morphing and response surface analysis: quantifying sensitivity of vertebral mechanical behavior
    • Sigal I.A., Whyne C.M. Mesh morphing and response surface analysis: quantifying sensitivity of vertebral mechanical behavior. Ann Biomed Eng 2009, 38:41-56.
    • (2009) Ann Biomed Eng , vol.38 , pp. 41-56
    • Sigal, I.A.1    Whyne, C.M.2
  • 8
    • 72449144548 scopus 로고    scopus 로고
    • Statistical modelling of the whole human femur incorporating geometric and material properties
    • Bryan R., Mohan P.S., Hopkins A., Galloway F., Taylor M., Nair P.B. Statistical modelling of the whole human femur incorporating geometric and material properties. Med Eng Phys 2010, 32:57-65.
    • (2010) Med Eng Phys , vol.32 , pp. 57-65
    • Bryan, R.1    Mohan, P.S.2    Hopkins, A.3    Galloway, F.4    Taylor, M.5    Nair, P.B.6
  • 9
    • 0036610881 scopus 로고    scopus 로고
    • Recent advances in mesh morphing
    • Alexa M. Recent advances in mesh morphing. Comput Graph Forum 2002, 21:173-198.
    • (2002) Comput Graph Forum , vol.21 , pp. 173-198
    • Alexa, M.1
  • 10
    • 42749090962 scopus 로고    scopus 로고
    • Mesh-morphing algorithms for specimen-specific finite element modeling
    • Sigal I.A., Hardisty M.R., Whyne C.M. Mesh-morphing algorithms for specimen-specific finite element modeling. J Biomech 2008, 41:1381-1389.
    • (2008) J Biomech , vol.41 , pp. 1381-1389
    • Sigal, I.A.1    Hardisty, M.R.2    Whyne, C.M.3
  • 12
    • 72449144548 scopus 로고    scopus 로고
    • Statistical modelling of the whole human femur incorporating geometric and material properties
    • Bryan R., Mohan P.S., Hopkins A., Galloway F., Taylor M., Nair P.B. Statistical modelling of the whole human femur incorporating geometric and material properties. Med Eng Phys 2009, 32:57-65.
    • (2009) Med Eng Phys , vol.32 , pp. 57-65
    • Bryan, R.1    Mohan, P.S.2    Hopkins, A.3    Galloway, F.4    Taylor, M.5    Nair, P.B.6
  • 13
    • 0034070906 scopus 로고    scopus 로고
    • The mesh-matching algorithm: an automatic 3D mesh generator for finite element structures
    • Couteau B., Payan Y., Lavallée S. The mesh-matching algorithm: an automatic 3D mesh generator for finite element structures. J Biomech 2000, 33:1005-1009.
    • (2000) J Biomech , vol.33 , pp. 1005-1009
    • Couteau, B.1    Payan, Y.2    Lavallée, S.3
  • 14
    • 33644697567 scopus 로고    scopus 로고
    • Orbital and maxillofacial computer aided surgery: patient-specific finite element models to predict surgical outcomes
    • Luboz V., Chabanas M., Swider P., Payan Y. Orbital and maxillofacial computer aided surgery: patient-specific finite element models to predict surgical outcomes. Comput Methods Biomech Biomed Eng 2005, 8:259-265.
    • (2005) Comput Methods Biomech Biomed Eng , vol.8 , pp. 259-265
    • Luboz, V.1    Chabanas, M.2    Swider, P.3    Payan, Y.4
  • 16
    • 58949083638 scopus 로고    scopus 로고
    • Comparison of computed tomography based parametric and patient-specific finite element models of the healthy and metastatic spine using a mesh-morphing algorithm
    • O'Reilly M.A., Whyne C.M. Comparison of computed tomography based parametric and patient-specific finite element models of the healthy and metastatic spine using a mesh-morphing algorithm. Spine (Phila Pa 1976) 2008, 33:1876-1881.
    • (2008) Spine (Phila Pa 1976) , vol.33 , pp. 1876-1881
    • O'Reilly, M.A.1    Whyne, C.M.2
  • 17
    • 34047116905 scopus 로고    scopus 로고
    • Geometric modeling of living tissue for subject-specific finite element analysis
    • Tada M., Yoshida H., Mochimaru M. Geometric modeling of living tissue for subject-specific finite element analysis. Conf Proc IEEE Eng Med Biol Soc 2006, (Suppl.):6639-6642.
    • (2006) Conf Proc IEEE Eng Med Biol Soc , Issue.SUPPL. , pp. 6639-6642
    • Tada, M.1    Yoshida, H.2    Mochimaru, M.3
  • 22
    • 76849092577 scopus 로고    scopus 로고
    • Three-dimensional morphing of similar shapes using a template mesh
    • Yoo D.-J. Three-dimensional morphing of similar shapes using a template mesh. Int J Precision Eng Manuf 2009, 10:55-66.
    • (2009) Int J Precision Eng Manuf , vol.10 , pp. 55-66
    • Yoo, D.-J.1
  • 25
    • 78650949346 scopus 로고    scopus 로고
    • Distributed volume morphing
    • Lin L., Lee C., Lee T.-Y. Distributed volume morphing. Cluster Comput 1999, 2:219-227.
    • (1999) Cluster Comput , vol.2 , pp. 219-227
    • Lin, L.1    Lee, C.2    Lee, T.-Y.3
  • 27
    • 0348046404 scopus 로고    scopus 로고
    • Automatic generation of finite element meshes from computed tomography data
    • Viceconti M., Taddei F. Automatic generation of finite element meshes from computed tomography data. Crit Rev Biomed Eng 2003, 31:27-72.
    • (2003) Crit Rev Biomed Eng , vol.31 , pp. 27-72
    • Viceconti, M.1    Taddei, F.2
  • 29
    • 0028400622 scopus 로고
    • Image warping by radial basis functions: applications to facial expressions. CVGIP: Graph
    • Arad N., Dyn N., Reisfeld D., Yeshurun Y. Image warping by radial basis functions: applications to facial expressions. CVGIP: Graph. Models Image Process 1994, 56:161-172.
    • (1994) Models Image Process , vol.56 , pp. 161-172
    • Arad, N.1    Dyn, N.2    Reisfeld, D.3    Yeshurun, Y.4
  • 30
    • 33750346371 scopus 로고    scopus 로고
    • Finite-element modeling of bones from CT data: sensitivity to geometry and material uncertainties
    • Taddei F., Martelli S., Reggiani B., Cristofolini L., Viceconti M. Finite-element modeling of bones from CT data: sensitivity to geometry and material uncertainties. IEEE Trans Biomed Eng 2006, 53:2194-2200.
    • (2006) IEEE Trans Biomed Eng , vol.53 , pp. 2194-2200
    • Taddei, F.1    Martelli, S.2    Reggiani, B.3    Cristofolini, L.4    Viceconti, M.5
  • 31
    • 0037410361 scopus 로고    scopus 로고
    • CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning
    • Viceconti M., Lattanzi R., Antonietti B., Paderni S., Olmi R., Sudanese A., et al. CT-based surgical planning software improves the accuracy of total hip replacement preoperative planning. Med Eng Phys 2003, 25:371-377.
    • (2003) Med Eng Phys , vol.25 , pp. 371-377
    • Viceconti, M.1    Lattanzi, R.2    Antonietti, B.3    Paderni, S.4    Olmi, R.5    Sudanese, A.6
  • 33
    • 0031408302 scopus 로고    scopus 로고
    • A critical analysis of stress shielding evaluation of hip prostheses
    • Cristofolini L. A critical analysis of stress shielding evaluation of hip prostheses. Crit Rev Biomed Eng 1997, 25:409-483.
    • (1997) Crit Rev Biomed Eng , vol.25 , pp. 409-483
    • Cristofolini, L.1
  • 34
    • 0020549477 scopus 로고
    • Cross-sectional geometry of Pecos Pueblo femora and tibiae-a biomechanical investigation. II. Sex, age, side differences
    • Ruff C.B., Hayes W.C. Cross-sectional geometry of Pecos Pueblo femora and tibiae-a biomechanical investigation. II. Sex, age, side differences. Am J Phys Anthropol 1983, 60:383-400.
    • (1983) Am J Phys Anthropol , vol.60 , pp. 383-400
    • Ruff, C.B.1    Hayes, W.C.2
  • 37
    • 48349100917 scopus 로고    scopus 로고
    • An accurate estimation of bone density improves the accuracy of subject-specific finite element models
    • Schileo E., Dall'ara E., Taddei F., Malandrino A., Schotkamp T., Baleani M., et al. An accurate estimation of bone density improves the accuracy of subject-specific finite element models. J Biomech 2008, 41:2483-2491.
    • (2008) J Biomech , vol.41 , pp. 2483-2491
    • Schileo, E.1    Dall'ara, E.2    Taddei, F.3    Malandrino, A.4    Schotkamp, T.5    Baleani, M.6
  • 38
    • 0038673390 scopus 로고    scopus 로고
    • Trabecular bone modulus-density relationships depend on anatomic site
    • Morgan E.F., Bayraktar H.H., Keaveny T.M. Trabecular bone modulus-density relationships depend on anatomic site. J Biomech 2003, 36:897-904.
    • (2003) J Biomech , vol.36 , pp. 897-904
    • Morgan, E.F.1    Bayraktar, H.H.2    Keaveny, T.M.3
  • 40
    • 0032681517 scopus 로고    scopus 로고
    • Improved Laplacian smoothing of noisy surface meshes
    • Vollmer J., Mencl R., uuml ller H. Improved Laplacian smoothing of noisy surface meshes. Comput Graph Forum 1999, 18:131-138.
    • (1999) Comput Graph Forum , vol.18 , pp. 131-138
    • Vollmer, J.1    Mencl, R.2    uuml, L.H.3
  • 41
    • 70449529507 scopus 로고    scopus 로고
    • Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements
    • Bah M.T., Nair P.B., Browne M. Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements. Med Eng Phys 2009, 31:1235-1243.
    • (2009) Med Eng Phys , vol.31 , pp. 1235-1243
    • Bah, M.T.1    Nair, P.B.2    Browne, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.