-
1
-
-
33744552498
-
A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint
-
Pena E., Calvo B., Martinez M.A., and Doblare M. A three-dimensional finite element analysis of the combined behavior of ligaments and menisci in the healthy human knee joint. Journal of Biomechanics 39 (2006) 1686-1701
-
(2006)
Journal of Biomechanics
, vol.39
, pp. 1686-1701
-
-
Pena, E.1
Calvo, B.2
Martinez, M.A.3
Doblare, M.4
-
2
-
-
0037230048
-
The effect of graft stiffness on knee joint biomechanics after ACL reconstruction-a 3D computational simulation
-
Suggs J., Wang C., and Li G. The effect of graft stiffness on knee joint biomechanics after ACL reconstruction-a 3D computational simulation. Clinical Biomechanics 18 (2003) 35-43
-
(2003)
Clinical Biomechanics
, vol.18
, pp. 35-43
-
-
Suggs, J.1
Wang, C.2
Li, G.3
-
3
-
-
33645742557
-
Stresses and strains in the medial meniscus of an ACL deficient knee under anterior loading: a finite element analysis with image-based experimental validation
-
Yao J., Snibbe J., Maloney M., and Lerner A.L. Stresses and strains in the medial meniscus of an ACL deficient knee under anterior loading: a finite element analysis with image-based experimental validation. Journal of Biomechanical Engineering 128 (2006) 135-141
-
(2006)
Journal of Biomechanical Engineering
, vol.128
, pp. 135-141
-
-
Yao, J.1
Snibbe, J.2
Maloney, M.3
Lerner, A.L.4
-
5
-
-
0037590458
-
Inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurement from MRI
-
McGibbon C.A. Inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurement from MRI. Magnetic Resonance Imaging 21 (2003) 707-714
-
(2003)
Magnetic Resonance Imaging
, vol.21
, pp. 707-714
-
-
McGibbon, C.A.1
-
6
-
-
0033028923
-
Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements
-
Cohen Z.A., McCarthy D.M., Kwak S.D., Legrand P., Fogarasi F., Ciaccio E.J., and Ateshian G.A. Knee cartilage topography, thickness, and contact areas from MRI: in-vitro calibration and in-vivo measurements. Osteoarthritis and Cartilage 7 (1999) 95-109
-
(1999)
Osteoarthritis and Cartilage
, vol.7
, pp. 95-109
-
-
Cohen, Z.A.1
McCarthy, D.M.2
Kwak, S.D.3
Legrand, P.4
Fogarasi, F.5
Ciaccio, E.J.6
Ateshian, G.A.7
-
10
-
-
33847418341
-
Statistical deformable bone models for robust 3D surface extrapolation from sparse data
-
Rajamani K.T., Styner M.A., Talib H., Zheng G., Nolte L.P., and Gonzalez Ballester M.A. Statistical deformable bone models for robust 3D surface extrapolation from sparse data. Medical Image Analysis 11 (2007) 99-109
-
(2007)
Medical Image Analysis
, vol.11
, pp. 99-109
-
-
Rajamani, K.T.1
Styner, M.A.2
Talib, H.3
Zheng, G.4
Nolte, L.P.5
Gonzalez Ballester, M.A.6
-
11
-
-
43749090230
-
Instantiation and registration of statistical shape models of the femur and pelvis using 3D ultrasound imaging
-
Barratt D.C., Chan C.S., Edwards P.J., Penney G.P., Slomczykowski M., Carter T.J., and Hawkes D.J. Instantiation and registration of statistical shape models of the femur and pelvis using 3D ultrasound imaging. Medical Image Analysis 12 (2008) 358-374
-
(2008)
Medical Image Analysis
, vol.12
, pp. 358-374
-
-
Barratt, D.C.1
Chan, C.S.2
Edwards, P.J.3
Penney, G.P.4
Slomczykowski, M.5
Carter, T.J.6
Hawkes, D.J.7
-
13
-
-
76749159148
-
Generation of a statistical model of the whole femur incorporating shape and material property distribution
-
Bryan R., Mohan S., Hopkins A., Nair P., and Taylor M. Generation of a statistical model of the whole femur incorporating shape and material property distribution. Transactions of the 54th Annual Meeting of the Orthopaedic Research Society, vol. 33 (2008) 0912
-
(2008)
Transactions of the 54th Annual Meeting of the Orthopaedic Research Society, vol. 33
, pp. 0912
-
-
Bryan, R.1
Mohan, S.2
Hopkins, A.3
Nair, P.4
Taylor, M.5
-
14
-
-
33748467122
-
Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy
-
Taddei F., Cristofolini L., Martelli S., Gill H.S., and Viceconti M. Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy. Journal of Biomechanics 39 (2006) 2457-2467
-
(2006)
Journal of Biomechanics
, vol.39
, pp. 2457-2467
-
-
Taddei, F.1
Cristofolini, L.2
Martelli, S.3
Gill, H.S.4
Viceconti, M.5
-
16
-
-
6044257795
-
Anatomically based geometric modelling of the musculo-skeletal system and other organs
-
Fernandez J.W., Mithraratne P., Thrupp S.F., Tawhai M.H., and Hunter P.J. Anatomically based geometric modelling of the musculo-skeletal system and other organs. Biomechanical Modeling in Mechanobiology 2 (2004) 139-155
-
(2004)
Biomechanical Modeling in Mechanobiology
, vol.2
, pp. 139-155
-
-
Fernandez, J.W.1
Mithraratne, P.2
Thrupp, S.F.3
Tawhai, M.H.4
Hunter, P.J.5
-
18
-
-
0034070906
-
The mesh-matching algorithm: an automatic 3D mesh generator for finite element structures
-
Couteau B., Payan Y., and Lavallee S. The mesh-matching algorithm: an automatic 3D mesh generator for finite element structures. Journal of Biomechanics 33 (2000) 1005-1009
-
(2000)
Journal of Biomechanics
, vol.33
, pp. 1005-1009
-
-
Couteau, B.1
Payan, Y.2
Lavallee, S.3
-
21
-
-
33751529487
-
The use of sparse CT datasets for auto-generating accurate FE models of the femur and pelvis
-
Shim V.B., Pitto R.P., Streicher R.M., Hunter P.J., and Anderson I.A. The use of sparse CT datasets for auto-generating accurate FE models of the femur and pelvis. Journal of Biomechanics 40 (2007) 26-35
-
(2007)
Journal of Biomechanics
, vol.40
, pp. 26-35
-
-
Shim, V.B.1
Pitto, R.P.2
Streicher, R.M.3
Hunter, P.J.4
Anderson, I.A.5
-
22
-
-
42749090962
-
Mesh-morphing algorithms for specimen-specific finite element modeling
-
Sigal I.A., Hardisty M.R., and Whyne C.M. Mesh-morphing algorithms for specimen-specific finite element modeling. Journal of Biomechanics 41 (2008) 1381-1389
-
(2008)
Journal of Biomechanics
, vol.41
, pp. 1381-1389
-
-
Sigal, I.A.1
Hardisty, M.R.2
Whyne, C.M.3
-
23
-
-
34250758694
-
Noninvasive determination of ligament strain with deformable image registration
-
Phatak N.S., Sun Q., Kim S.E., Parker D.L., Sanders R.K., Veress A.I., Ellis B.J., and Weiss J.A. Noninvasive determination of ligament strain with deformable image registration. Annals of Biomedical Engineering 35 (2007) 1175-1187
-
(2007)
Annals of Biomedical Engineering
, vol.35
, pp. 1175-1187
-
-
Phatak, N.S.1
Sun, Q.2
Kim, S.E.3
Parker, D.L.4
Sanders, R.K.5
Veress, A.I.6
Ellis, B.J.7
Weiss, J.A.8
-
24
-
-
41549114248
-
Knee joint biomechanics in open-kinetic-chain flexion exercises
-
Mesfar W., and Shirazi-Adl A. Knee joint biomechanics in open-kinetic-chain flexion exercises. Clinical Biomechanics 23 (2008) 477-482
-
(2008)
Clinical Biomechanics
, vol.23
, pp. 477-482
-
-
Mesfar, W.1
Shirazi-Adl, A.2
-
25
-
-
0032794155
-
Patellar contact forces with and without patellar resurfacing in total knee arthroplasty
-
Singerman R., Gabriel S.M., Maheshwer C.B., and Kennedy J.W. Patellar contact forces with and without patellar resurfacing in total knee arthroplasty. Journal of Arthroplasty 14 (1999) 603-609
-
(1999)
Journal of Arthroplasty
, vol.14
, pp. 603-609
-
-
Singerman, R.1
Gabriel, S.M.2
Maheshwer, C.B.3
Kennedy, J.W.4
-
27
-
-
33746902830
-
Knee joint mechanics under quadriceps-hamstrings muscle forces are influenced by tibial restraint
-
Mesfar W., and Shirazi-Adl A. Knee joint mechanics under quadriceps-hamstrings muscle forces are influenced by tibial restraint. Clinical Biomechanics 21 (2006) 841-848
-
(2006)
Clinical Biomechanics
, vol.21
, pp. 841-848
-
-
Mesfar, W.1
Shirazi-Adl, A.2
-
28
-
-
0346761904
-
Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies
-
Viceconti M., Davinelli M., Taddei F., and Cappello A. Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies. Journal of Biomechanics 37 (2004) 1597-1605
-
(2004)
Journal of Biomechanics
, vol.37
, pp. 1597-1605
-
-
Viceconti, M.1
Davinelli, M.2
Taddei, F.3
Cappello, A.4
-
29
-
-
56349146883
-
Development and validation of patient-specific finite element models of the hemipelvis generated from a sparse CT data set
-
Shim V.B., Pitto R.P., Streicher R.M., Hunter P.J., and Anderson I.A. Development and validation of patient-specific finite element models of the hemipelvis generated from a sparse CT data set. Journal of Biomechanical Engineering-Transactions of the ASME 130 (2008) 051010
-
(2008)
Journal of Biomechanical Engineering-Transactions of the ASME
, vol.130
, pp. 051010
-
-
Shim, V.B.1
Pitto, R.P.2
Streicher, R.M.3
Hunter, P.J.4
Anderson, I.A.5
-
30
-
-
27744519493
-
Biomechanics of the knee joint in flexion under various quadriceps forces
-
Mesfar W., and Shirazi-Adl A. Biomechanics of the knee joint in flexion under various quadriceps forces. Knee 12 (2005) 424-434
-
(2005)
Knee
, vol.12
, pp. 424-434
-
-
Mesfar, W.1
Shirazi-Adl, A.2
-
31
-
-
14244264494
-
Patellofemoral joint contact area increases with knee flexion and weight-bearing
-
Besier T.F., Draper C.E., Gold G.E., Beaupre G.S., and Delp S.L. Patellofemoral joint contact area increases with knee flexion and weight-bearing. Journal of Orthopaedic Research 23 (2005) 345-350
-
(2005)
Journal of Orthopaedic Research
, vol.23
, pp. 345-350
-
-
Besier, T.F.1
Draper, C.E.2
Gold, G.E.3
Beaupre, G.S.4
Delp, S.L.5
-
32
-
-
77949892182
-
-
doi:10.1080/10255840902822550
-
M.A. Baldwin, P.J. Laz, J.Q. Stowe, P.J. Rullkoetter, Efficient probabilistic representation of tibiofemoral soft tissue constraint, Computer Methods in Biomechanics and Biomedical Engineering, (2009), doi:10.1080/10255840902822550.
-
(2009)
Efficient probabilistic representation of tibiofemoral soft tissue constraint, Computer Methods in Biomechanics and Biomedical Engineering
-
-
Baldwin, M.A.1
Laz, P.J.2
Stowe, J.Q.3
Rullkoetter, P.J.4
-
33
-
-
38149082130
-
Sensitivity of tibio-menisco-femoral joint contact behavior to variations in knee kinematics
-
Yao J., Salo A.D., Lee J., and Lerner A.L. Sensitivity of tibio-menisco-femoral joint contact behavior to variations in knee kinematics. Journal of Biomechanics 41 (2008) 390-398
-
(2008)
Journal of Biomechanics
, vol.41
, pp. 390-398
-
-
Yao, J.1
Salo, A.D.2
Lee, J.3
Lerner, A.L.4
-
34
-
-
42049113678
-
Tibiofemoral cartilage thickness distribution and its correlation with anthropometric variables
-
Connolly A., FitzPatrick D., Moulton J., Lee J., and Lerner A. Tibiofemoral cartilage thickness distribution and its correlation with anthropometric variables. Proceedings of the IMechE - Part H: Journal of Engineering in Medicine 222 (2008) 29-39
-
(2008)
Proceedings of the IMechE - Part H: Journal of Engineering in Medicine
, vol.222
, pp. 29-39
-
-
Connolly, A.1
FitzPatrick, D.2
Moulton, J.3
Lee, J.4
Lerner, A.5
|