메뉴 건너뛰기




Volumn 31, Issue 10, 2009, Pages 1235-1243

Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements

Author keywords

Cementless hip replacement; Finite element mesh; Implant positioning; Morphing

Indexed keywords

AVERAGE STRAIN; BONE VOLUME; CEMENTLESS; CEMENTLESS HIP REPLACEMENT; CONTACT ANALYSIS; DEFORMATION FIELD; FINITE ELEMENT ANALYSIS; FINITE ELEMENT MESH; FINITE ELEMENTS; HIP REPLACEMENTS; IMPLANT POSITIONING; LABOUR-INTENSIVE; LINEAR ELASTICITY PROBLEMS; MESH MODEL; MESH MORPHING; MICROMOTION; MODEL GENERATION; MORPHING; MORPHING TECHNIQUES; MUSCLE LOADING; SPECIFIC ORIENTATION; STABILITY ANALYSIS; STRAIN DISTRIBUTIONS; TOTAL HIP REPLACEMENTS;

EID: 70449529507     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2009.08.001     Document Type: Article
Times cited : (37)

References (30)
  • 1
    • 0037822087 scopus 로고    scopus 로고
    • Dislocation after total hip arthroplasty: implant design and orientation
    • Barrack R.L. Dislocation after total hip arthroplasty: implant design and orientation. Journal of the American Academy of Orthopaedic Surgeons 11 2 (2003) 89-99
    • (2003) Journal of the American Academy of Orthopaedic Surgeons , vol.11 , Issue.2 , pp. 89-99
    • Barrack, R.L.1
  • 2
    • 33847689072 scopus 로고    scopus 로고
    • Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty
    • Parratte S., and Argenson J.-N.A. Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. The Journal of Bone & Joint Surgery 89-A (2007) 494-499
    • (2007) The Journal of Bone & Joint Surgery , vol.89 -A , pp. 494-499
    • Parratte, S.1    Argenson, J.-N.A.2
  • 3
    • 0025872043 scopus 로고
    • Rotation affects apparent radiographic positioning of femoral components in total hip arthroplasty
    • Albert T.J., Sharkey P.F., Chao W., Hume E.L., and Rothman R.H. Rotation affects apparent radiographic positioning of femoral components in total hip arthroplasty. The Journal of Arthroplasty 6 (1991) S67-S71
    • (1991) The Journal of Arthroplasty , vol.6
    • Albert, T.J.1    Sharkey, P.F.2    Chao, W.3    Hume, E.L.4    Rothman, R.H.5
  • 4
    • 70449522609 scopus 로고    scopus 로고
    • ANSYS, 2008. ANSYS Theory Reference Manual Release 11.0, Ansys Inc.
    • ANSYS, 2008. ANSYS Theory Reference Manual Release 11.0, Ansys Inc.
  • 5
    • 0034949386 scopus 로고    scopus 로고
    • A technique for accurate reproduction of the femoral anteversion during primary total hip arthroplasty
    • Karnezis A. A technique for accurate reproduction of the femoral anteversion during primary total hip arthroplasty. Architecture Orthopaedic and Traumatologic Surgery 121 (2001) 343-345
    • (2001) Architecture Orthopaedic and Traumatologic Surgery , vol.121 , pp. 343-345
    • Karnezis, A.1
  • 6
    • 0346761904 scopus 로고    scopus 로고
    • Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies
    • Viceconti M., Davinelli M., Taddei F., and Capello A. Automatic generation of accurate subject-specific bone finite element models to be used in clinical studies. Journal of Biomechanics 37 (2004) 1597-1605
    • (2004) Journal of Biomechanics , vol.37 , pp. 1597-1605
    • Viceconti, M.1    Davinelli, M.2    Taddei, F.3    Capello, A.4
  • 7
    • 33947704275 scopus 로고    scopus 로고
    • Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis
    • Radcliffe I.A.J., and Taylor M. Investigation into the affect of cementing techniques on load transfer in the resurfaced femoral head: a multi-femur finite element analysis. Clinical Biomechanics 22 4 (2007) 422-430
    • (2007) Clinical Biomechanics , vol.22 , Issue.4 , pp. 422-430
    • Radcliffe, I.A.J.1    Taylor, M.2
  • 8
    • 64749100658 scopus 로고    scopus 로고
    • A convenient approach for finite-element-analyses of orthopaedic implants in bone contact: modeling and experimental validation
    • Kluess D., Souffrant R., Mittelmeier W., Wree A., Schmitz K., and Bader R. A convenient approach for finite-element-analyses of orthopaedic implants in bone contact: modeling and experimental validation. Computer Methods and Programs in Biomedicine 95 1 (2009) 23-30
    • (2009) Computer Methods and Programs in Biomedicine , vol.95 , Issue.1 , pp. 23-30
    • Kluess, D.1    Souffrant, R.2    Mittelmeier, W.3    Wree, A.4    Schmitz, K.5    Bader, R.6
  • 9
    • 77953968673 scopus 로고    scopus 로고
    • The space of all body shapes: Reconstruction and parameterization from range scans
    • Allen, B., Curless, B., Popović, Z., 2003. The space of all body shapes: reconstruction and parameterization from range scans. ACM Transactions on Graphics (ACM SIGGRAPH 2003) 22(3), 587-594.
    • (2003) ACM Transactions on Graphics (ACM SIGGRAPH , vol.22 , Issue.3 , pp. 587-594
    • Allen, B.1    Curless, B.2    Popović, Z.3
  • 10
    • 42749090962 scopus 로고    scopus 로고
    • Mesh-morphing algorithms for specimen-specific finite element modeling
    • Sigal I.A., Hardisty M.R., and Whyne C.M. Mesh-morphing algorithms for specimen-specific finite element modeling. Journal of Biomechanics 41 (2008) 1381-1389
    • (2008) Journal of Biomechanics , vol.41 , pp. 1381-1389
    • Sigal, I.A.1    Hardisty, M.R.2    Whyne, C.M.3
  • 13
    • 0026995387 scopus 로고
    • Computation of unsteady incompressible flows with the stabilized finite element methods: space-time formulations iterative strategies and massively parallel implementations
    • Smolinski P., Liu W.K., Hulbert G., and Tamma K. (Eds), ASME, New York
    • Tezduyar T.E., Behr M., Mittal S., and Johnson A.A. Computation of unsteady incompressible flows with the stabilized finite element methods: space-time formulations iterative strategies and massively parallel implementations. In: Smolinski P., Liu W.K., Hulbert G., and Tamma K. (Eds). New methods in transient analysis, AMD-vol. 143 (1992), ASME, New York 7-24
    • (1992) New methods in transient analysis, AMD-vol. 143 , pp. 7-24
    • Tezduyar, T.E.1    Behr, M.2    Mittal, S.3    Johnson, A.A.4
  • 15
    • 0037236185 scopus 로고    scopus 로고
    • Mesh moving techniques for fluid-structure interactions with large displacements
    • Stein K., Tezduyar T., and Benney R. Mesh moving techniques for fluid-structure interactions with large displacements. ASME Journal of Applied Mechanics 70 (2003) 58-63
    • (2003) ASME Journal of Applied Mechanics , vol.70 , pp. 58-63
    • Stein, K.1    Tezduyar, T.2    Benney, R.3
  • 16
    • 34047196824 scopus 로고    scopus 로고
    • Mesh deformation using radial basis functions for gradient-based aerodynamic shape optimization
    • Jakobsson S., and Amoignon O. Mesh deformation using radial basis functions for gradient-based aerodynamic shape optimization. Computers and Fluids 36 6 (2007) 1119-1136
    • (2007) Computers and Fluids , vol.36 , Issue.6 , pp. 1119-1136
    • Jakobsson, S.1    Amoignon, O.2
  • 19
    • 0344440923 scopus 로고    scopus 로고
    • An improved method for the automatic mapping of computed tomography numbers onto finite element models
    • Taddei F., Pancanti A., and Viceconti M. An improved method for the automatic mapping of computed tomography numbers onto finite element models. Journal of Medical Engineering & Physics 26 (2004) 61-69
    • (2004) Journal of Medical Engineering & Physics , vol.26 , pp. 61-69
    • Taddei, F.1    Pancanti, A.2    Viceconti, M.3
  • 20
    • 0038673390 scopus 로고    scopus 로고
    • Trabecular bone modulus-density relationships depend on anatomic site
    • Morgan E.F., Bayraktar H.H., and Keaveny T.M. Trabecular bone modulus-density relationships depend on anatomic site. Journal of Biomechanics 36 (2003) 897-904
    • (2003) Journal of Biomechanics , vol.36 , pp. 897-904
    • Morgan, E.F.1    Bayraktar, H.H.2    Keaveny, T.M.3
  • 21
    • 0033810865 scopus 로고    scopus 로고
    • Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration
    • Viceconti M., Muccini R., Bernakiewicz M., Baleani M., and Cristofilini L. Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osseointegration. Journal of Biomechanics 33 (2000) 1611-1618
    • (2000) Journal of Biomechanics , vol.33 , pp. 1611-1618
    • Viceconti, M.1    Muccini, R.2    Bernakiewicz, M.3    Baleani, M.4    Cristofilini, L.5
  • 23
    • 50249134426 scopus 로고    scopus 로고
    • Constitutive modelling of inelastic behaviour or cortical bone
    • Natali A.N., Carniel E.L., and Pavan P.G. Constitutive modelling of inelastic behaviour or cortical bone. Medical Engineering & Physics 30 7 (2007) 905-912
    • (2007) Medical Engineering & Physics , vol.30 , Issue.7 , pp. 905-912
    • Natali, A.N.1    Carniel, E.L.2    Pavan, P.G.3
  • 24
    • 33748467122 scopus 로고    scopus 로고
    • Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy
    • Taddei F., Cristofolini L., Martelli S., Gill H., and Viceconti M. Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy. Journal of Biomechanics 39 13 (2006) 2457-2467
    • (2006) Journal of Biomechanics , vol.39 , Issue.13 , pp. 2457-2467
    • Taddei, F.1    Cristofolini, L.2    Martelli, S.3    Gill, H.4    Viceconti, M.5
  • 25
    • 33745007333 scopus 로고    scopus 로고
    • True femoral anteversion during primary total hip arthroplasty: use of postoperative computed tomography-based sections
    • Suh K.T., Kang L.H., Roh H.L., Moon K.P., and Kim H.J. True femoral anteversion during primary total hip arthroplasty: use of postoperative computed tomography-based sections. The Journal of Arthroplasty 21 (2004) 599-605
    • (2004) The Journal of Arthroplasty , vol.21 , pp. 599-605
    • Suh, K.T.1    Kang, L.H.2    Roh, H.L.3    Moon, K.P.4    Kim, H.J.5
  • 26
    • 18944375927 scopus 로고    scopus 로고
    • Long-term results of the cementless porous-coated anatomic total hip prosthesis
    • Kim Y.-H. Long-term results of the cementless porous-coated anatomic total hip prosthesis. The Journal of Bone & Joint Surgery British 87-B (2005) 623-627
    • (2005) The Journal of Bone & Joint Surgery British , vol.87 -B , pp. 623-627
    • Kim, Y.-H.1
  • 27
    • 15944407626 scopus 로고    scopus 로고
    • Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro
    • Kassi J.-P., Heller M.O., Stoeckle U., Perka C., and Duda G.N. Stair climbing is more critical than walking in pre-clinical assessment of primary stability in cementless THA in vitro. Journal of Biomechanics 38 (2005) 1143-1154
    • (2005) Journal of Biomechanics , vol.38 , pp. 1143-1154
    • Kassi, J.-P.1    Heller, M.O.2    Stoeckle, U.3    Perka, C.4    Duda, G.N.5
  • 28
    • 38749142862 scopus 로고    scopus 로고
    • Finite element modelling of primary hip stem stability: the effect of interference fit
    • Abdul-Kadir M.R., Hansen U., Klabunde R., Lucas D., and Amis A. Finite element modelling of primary hip stem stability: the effect of interference fit. Journal of Biomechanics 41 3 (2008) 587-594
    • (2008) Journal of Biomechanics , vol.41 , Issue.3 , pp. 587-594
    • Abdul-Kadir, M.R.1    Hansen, U.2    Klabunde, R.3    Lucas, D.4    Amis, A.5
  • 29
    • 0000961141 scopus 로고    scopus 로고
    • Sensitivity of failure criteria of cemented total hip replacements to finite element mesh density
    • Stolk J., Verdonschot N., and Huiskes R. Sensitivity of failure criteria of cemented total hip replacements to finite element mesh density. Journal of Biomechanics 30 (1998) 165
    • (1998) Journal of Biomechanics , vol.30 , pp. 165
    • Stolk, J.1    Verdonschot, N.2    Huiskes, R.3
  • 30
    • 0002554442 scopus 로고    scopus 로고
    • Free-surface flow simulation using hp spectral elements
    • Robertson I., and Sherwin S. Free-surface flow simulation using hp spectral elements. Journal of Computational Physics 155 1 (1999) 26-53
    • (1999) Journal of Computational Physics , vol.155 , Issue.1 , pp. 26-53
    • Robertson, I.1    Sherwin, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.