메뉴 건너뛰기




Volumn 93, Issue 1, 2011, Pages 57-65

Fracture of cementless femoral stems at the mid-stem junction in modular revision hip arthroplasty systems

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BODY MASS; BODY WEIGHT; CEMENTLESS FEMORAL STEM FRACTURE; CHEMICAL COMPOSITION; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FOLLOW UP; FRACTURE; HIP ARTHROPLASTY; HUMAN; IMPLANT; MALE; PRIORITY JOURNAL; RADIOGRAPHY; RISK FACTOR;

EID: 78650927177     PISSN: 00219355     EISSN: 15351386     Source Type: Journal    
DOI: 10.2106/JBJS.I.01589     Document Type: Article
Times cited : (157)

References (34)
  • 1
    • 0027461703 scopus 로고
    • Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs
    • Dall DM, Learmonth ID, Solomon MI, Miles AW, Davenport JM. Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designs. J Bone Joint Surg Br. 1993;75:259-65.
    • (1993) J Bone Joint Surg Br , vol.75 , pp. 259-265
    • Dall, D.M.1    Learmonth, I.D.2    Solomon, M.I.3    Miles, A.W.4    Davenport, J.M.5
  • 5
    • 34547591739 scopus 로고    scopus 로고
    • Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation
    • Buttaro MA, Mayor MB, Van Citters D, Piccaluga F. Fatigue fracture of a proximally modular, distally tapered fluted implant with diaphyseal fixation. J Arthroplasty. 2007;22:780-3.
    • (2007) J Arthroplasty , vol.22 , pp. 780-783
    • Buttaro, M.A.1    Mayor, M.B.2    Van Citters, D.3    Piccaluga, F.4
  • 6
    • 0020442565 scopus 로고
    • Fracture failure of a forged vitallium prosthesis. A case report
    • Miller EH, Shastri R, Shih CI. Fracture failure of a forged vitallium prosthesis. A case report. J Bone Joint Surg Am. 1982;64:1359-63.
    • (1982) J Bone Joint Surg Am , vol.64 , pp. 1359-1363
    • Miller, E.H.1    Shastri, R.2    Shih, C.I.3
  • 8
    • 77953292612 scopus 로고    scopus 로고
    • Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up
    • Lakstein D, Backstein D, Safir O, Kosashvili Y, Gross AE. Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res. 2010;468:1310-5.
    • (2010) Clin Orthop Relat Res , vol.468 , pp. 1310-1315
    • Lakstein, D.1    Backstein, D.2    Safir, O.3    Kosashvili, Y.4    Gross, A.E.5
  • 9
    • 52249087579 scopus 로고    scopus 로고
    • Five- to 10-year results using a noncemented modular revision stem without bone grafting
    • Köster G, Walde TA, Willert HG. Five- to 10-year results using a noncemented modular revision stem without bone grafting. J Arthroplasty. 2008;23:964-70.
    • (2008) J Arthroplasty , vol.23 , pp. 964-970
    • Köster, G.1    Walde, T.A.2    Willert, H.G.3
  • 10
    • 0031443563 scopus 로고    scopus 로고
    • 5- to 13-year follow-up study on cementless femoral components in revision surgery
    • Krishnamurthy AB, MacDonald SJ, Paprosky WG. 5- to 13-year follow-up study on cementless femoral components in revision surgery. J Arthroplasty. 1997;12:839-47.
    • (1997) J Arthroplasty , vol.12 , pp. 839-847
    • Krishnamurthy, A.B.1    MacDonald, S.J.2    Paprosky, W.G.3
  • 11
    • 0034924526 scopus 로고    scopus 로고
    • Femoral revision with the Wagner SL revision stem: Evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years
    • Böhm P, Bischel O. Femoral revision with the Wagner SL revision stem: evaluation of one hundred and twenty-nine revisions followed for a mean of 4.8 years. J Bone Joint Surg Am. 2001;83:1023-31.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1023-1031
    • Böhm, P.1    Bischel, O.2
  • 13
    • 0037967342 scopus 로고    scopus 로고
    • Orthopaedic Crossfire-stem modularity is unnecessary in revision total hip arthroplasty: In the affirmative
    • Barrack RL. Orthopaedic Crossfire-stem modularity is unnecessary in revision total hip arthroplasty: in the affirmative. J Arthroplasty. 2003;18(3 Suppl 1):98-100.
    • (2003) J Arthroplasty , vol.18 , Issue.3 SUPPL. 1 , pp. 98-100
    • Barrack, R.L.1
  • 14
    • 33845394645 scopus 로고    scopus 로고
    • Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems
    • Garbuz DS, Toms A, Masri BA, Duncan CP. Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems. Clin Orthop Relat Res. 2006;453:199-202.
    • (2006) Clin Orthop Relat Res , vol.453 , pp. 199-202
    • Garbuz, D.S.1    Toms, A.2    Masri, B.A.3    Duncan, C.P.4
  • 15
    • 77950519539 scopus 로고    scopus 로고
    • Revision total hip arthroplasty using a modular tapered stem with distal fixation: Good short-term results in 125 revisions
    • Ovesen O, Emmeluth C, Hofbauer C, Overgaard S. Revision total hip arthroplasty using a modular tapered stem with distal fixation: good short-term results in 125 revisions. J Arthroplasty. 2010;25:348-54.
    • (2010) J Arthroplasty , vol.25 , pp. 348-354
    • Ovesen, O.1    Emmeluth, C.2    Hofbauer, C.3    Overgaard, S.4
  • 16
    • 77950520501 scopus 로고    scopus 로고
    • Femoral stem fractures in Zimmer modular revision (ZMRÒ) hip systems
    • Femoral stem fractures in Zimmer modular revision (ZMRÒ) hip systems. TGA News. 2003;40:20.
    • (2003) TGA News , vol.40 , pp. 20
  • 17
    • 0034925209 scopus 로고    scopus 로고
    • Reliability and intraoperative validity of preoperative assessment of standardized plain radiographs in predicting bone loss at revision hip surgery
    • Saleh KJ, Holtzman J, Gafni A, Saleh L, Davis A, Resig S, Gross AE. Reliability and intraoperative validity of preoperative assessment of standardized plain radiographs in predicting bone loss at revision hip surgery. J Bone Joint Surg Am. 2001;83:1040-6.
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 1040-1046
    • Saleh, K.J.1    Holtzman, J.2    Gafni, A.3    Saleh, L.4    Davis, A.5    Resig, S.6    Gross, A.E.7
  • 18
    • 2942554990 scopus 로고    scopus 로고
    • Revision total hip arthroplasty with proximal bone loss
    • Murphy SB, Rodriguez J. Revision total hip arthroplasty with proximal bone loss. J Arthroplasty. 2004;19(4 Suppl 1):115-9.
    • (2004) J Arthroplasty , vol.19 , Issue.4 SUPPL. 1 , pp. 115-119
    • Murphy, S.B.1    Rodriguez, J.2
  • 19
    • 29244474600 scopus 로고    scopus 로고
    • Late fatigue fracture of a modern cemented [corrected] cobalt chrome stem for total hip arthroplasty: A report of 10 cases
    • Della Valle AG, Becksacx B, Anderson J, Wright T, Nestor B, Pellicci PM, Salvati EA. Late fatigue fracture of a modern cemented [corrected] cobalt chrome stem for total hip arthroplasty: a report of 10 cases. J Arthroplasty. 2005;20:1084-8.
    • (2005) J Arthroplasty , vol.20 , pp. 1084-1088
    • Della Valle, A.G.1    Becksacx, B.2    Anderson, J.3    Wright, T.4    Nestor, B.5    Pellicci, P.M.6    Salvati, E.A.7
  • 20
    • 0031444317 scopus 로고    scopus 로고
    • Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases
    • Woolson ST, Milbauer JP, Bobyn JD, Yue S, Maloney WJ. Fatigue fracture of a forged cobalt-chromium-molybdenum femoral component inserted with cement. A report of ten cases. J Bone Joint Surg Am. 1997;79:1842-8.
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1842-1848
    • Woolson, S.T.1    Milbauer, J.P.2    Bobyn, J.D.3    Yue, S.4    Maloney, W.J.5
  • 22
    • 0018838142 scopus 로고
    • Three dimensional stress analysis of the femoral stem of a total hip prosthesis
    • Hampton SJ, Andriacchi TP, Galante JO. Three dimensional stress analysis of the femoral stem of a total hip prosthesis. J Biomech. 1980;13:443-8.
    • (1980) J Biomech , vol.13 , pp. 443-448
    • Hampton, S.J.1    Andriacchi, T.P.2    Galante, J.O.3
  • 23
    • 77950516515 scopus 로고    scopus 로고
    • Modified trochanteric slide for complex hip arthroplasty: Clinical outcomes and complication rates
    • Lakstein D, Backstein DJ, Safir O, Kosashvili Y, Gross AE. Modified trochanteric slide for complex hip arthroplasty: clinical outcomes and complication rates. J Arthroplasty. 2010;25:363-8.
    • (2010) J Arthroplasty , vol.25 , pp. 363-368
    • Lakstein, D.1    Backstein, D.J.2    Safir, O.3    Kosashvili, Y.4    Gross, A.E.5
  • 24
    • 0035216888 scopus 로고    scopus 로고
    • The extended trochanteric osteotomy in revision hip arthroplasty: A critical review of 166 cases at mean 3-year, 9-month follow-up
    • Miner TM, Momberger NG, Chong D, Paprosky WL. The extended trochanteric osteotomy in revision hip arthroplasty: a critical review of 166 cases at mean 3-year, 9-month follow-up. J Arthroplasty. 2001;16(8 Suppl 1):S188-94.
    • (2001) J Arthroplasty , vol.16 , Issue.8 SUPPL. 1
    • Miner, T.M.1    Momberger, N.G.2    Chong, D.3    Paprosky, W.L.4
  • 28
    • 0141731309 scopus 로고    scopus 로고
    • Fretting fatigue behaviour of shot-peened Ti-6Al-4V at room and elevated temperatures
    • Lee H, Jin O, Mall S. Fretting fatigue behaviour of shot-peened Ti-6Al-4V at room and elevated temperatures. Fatigue Fract Eng Mater Struct. 2003;26:767-78.
    • (2003) Fatigue Fract Eng Mater Struct , vol.26 , pp. 767-778
    • Lee, H.1    Jin, O.2    Mall, S.3
  • 30
    • 12344255851 scopus 로고    scopus 로고
    • Metallurgical failure analysis of various implant materials used in orthopedic applications
    • Aksakal B, Yildirim ÖS, Gul H. Metallurgical failure analysis of various implant materials used in orthopedic applications. J Failure Anal Prevent. 2004;4:17-23.
    • (2004) J Failure Anal Prevent , vol.4 , pp. 17-23
    • Aksakal, B.1    Yildirim, Ö.S.2    Gul, H.3
  • 31
    • 30644479707 scopus 로고    scopus 로고
    • Corrosion of modular titanium alloy stems in cementless hip replacement
    • Urban RM, Gilbert JL, Jacobs JJ. Corrosion of modular titanium alloy stems in cementless hip replacement. J ASTM Int. 2005;2:1-10.
    • (2005) J ASTM Int , vol.2 , pp. 1-10
    • Urban, R.M.1    Gilbert, J.L.2    Jacobs, J.J.3
  • 32
    • 57349149061 scopus 로고    scopus 로고
    • In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants
    • Rodrigues DC, Urban RM, Jacobs JJ, Gilbert JL. In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants. J Biomed Mater Res B Appl Biomater. 2009;88:206-19.
    • (2009) J Biomed Mater Res B Appl Biomater , vol.88 , pp. 206-219
    • Rodrigues, D.C.1    Urban, R.M.2    Jacobs, J.J.3    Gilbert, J.L.4
  • 33
    • 0037805083 scopus 로고    scopus 로고
    • Failures of stainless steel orthopaedic devices: Causes and remedies
    • Kamachi Mudali U, Sridhar TM, Eliaz N, Baldev RAJ. Failures of stainless steel orthopaedic devices: causes and remedies. Corros Rev. 2003;21:231-67.
    • (2003) Corros Rev , vol.21 , pp. 231-267
    • Kamachi Mudali, U.1    Sridhar, T.M.2    Eliaz, N.3    Baldev, R.A.J.4
  • 34
    • 59449088766 scopus 로고    scopus 로고
    • Biomaterials and corrosion
    • Kamachi Mudali U, Raj Baldev, editors. New Delhi: Narosa Publishing House
    • Eliaz N. Biomaterials and corrosion. In: Kamachi Mudali U, Raj Baldev, editors. Corrosion science and technology: Mechanism, mitigation and monitoring. New Delhi: Narosa Publishing House; 2008. p 356-97.
    • (2008) Corrosion Science and Technology: Mechanism, Mitigation and Monitoring , pp. 356-397
    • Eliaz, N.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.