-
2
-
-
33645347668
-
Overview of image-guided radiation therapy
-
L. Xing, B. Thorndyke, and E. Schreibmann Overview of image-guided radiation therapy Med Dosim 31 2006 91 112
-
(2006)
Med Dosim
, vol.31
, pp. 91-112
-
-
Xing, L.1
Thorndyke, B.2
Schreibmann, E.3
-
3
-
-
33644947940
-
Linac-integrated kV-cone beam CT: Technical features and first applications
-
U. Oelfke, T. Tucking, and S. Nill Linac-integrated kV-cone beam CT: Technical features and first applications Med Dosim 31 2006 62 70
-
(2006)
Med Dosim
, vol.31
, pp. 62-70
-
-
Oelfke, U.1
Tucking, T.2
Nill, S.3
-
4
-
-
67349247094
-
Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance
-
J.J. Sonke, M. Rossi, and J. Wolthaus Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance Int J Radiat Oncol Biol Phys 74 2009 567 574
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 567-574
-
-
Sonke, J.J.1
Rossi, M.2
Wolthaus, J.3
-
5
-
-
16344373639
-
The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating
-
D.P. Gierga, J. Brewer, and G.C. Sharp The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating Int J Radiat Oncol Biol Phys 61 2005 1551 1558
-
(2005)
Int J Radiat Oncol Biol Phys
, vol.61
, pp. 1551-1558
-
-
Gierga, D.P.1
Brewer, J.2
Sharp, G.C.3
-
6
-
-
33846245486
-
Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT
-
A.S. Beddar, K. Kainz, and T.M. Briere Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT Int J Radiat Oncol Biol Phys 67 2007 630 638
-
(2007)
Int J Radiat Oncol Biol Phys
, vol.67
, pp. 630-638
-
-
Beddar, A.S.1
Kainz, K.2
Briere, T.M.3
-
7
-
-
4444313627
-
Feasibility of synchronization of realtime tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy
-
H. Shirato, M. Oita, and K. Fujita Feasibility of synchronization of realtime tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy Int J Radiat Oncol Biol Phys 60 2004 334 341
-
(2004)
Int J Radiat Oncol Biol Phys
, vol.60
, pp. 334-341
-
-
Shirato, H.1
Oita, M.2
Fujita, K.3
-
9
-
-
7244242297
-
Respiration tracking in radiosurgery
-
A. Schweikard, H. Shiomi, and J. Adler Respiration tracking in radiosurgery Med Phys 31 2004 2738 2741
-
(2004)
Med Phys
, vol.31
, pp. 2738-2741
-
-
Schweikard, A.1
Shiomi, H.2
Adler, J.3
-
10
-
-
34347390456
-
Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study
-
Y. Seppenwoolde, R.I. Berbeco, and S. Nishioka Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study Med Phys 34 2007 2774 2784
-
(2007)
Med Phys
, vol.34
, pp. 2774-2784
-
-
Seppenwoolde, Y.1
Berbeco, R.I.2
Nishioka, S.3
-
11
-
-
33845335866
-
An analysis of the treatment couch and control system dynamics for respiration-induced motion compensation
-
W.D. D'Souza, and T.J. McAvoy An analysis of the treatment couch and control system dynamics for respiration-induced motion compensation Med Phys 33 2006 4701 4709
-
(2006)
Med Phys
, vol.33
, pp. 4701-4709
-
-
D'Souza, W.D.1
McAvoy, T.J.2
-
12
-
-
34748837343
-
Inferential modelling and predictive feedback control in real-time motion compensation using the treatment couch during radiotherapy
-
P. Qiu, W.D. D'Souza, and T.J. McAvoy Inferential modelling and predictive feedback control in real-time motion compensation using the treatment couch during radiotherapy Phys Med Biol 52 2007 5831 5854
-
(2007)
Phys Med Biol
, vol.52
, pp. 5831-5854
-
-
Qiu, P.1
D'Souza, W.D.2
McAvoy, T.J.3
-
13
-
-
0034333029
-
Physical aspects of a real-time tumor-tracking system for gated radiotherapy
-
H. Shirato, S. Shimizu, and T. Kunieda Physical aspects of a real-time tumor-tracking system for gated radiotherapy Int J Radiat Oncol Biol Phys 48 2000 1187 1195
-
(2000)
Int J Radiat Oncol Biol Phys
, vol.48
, pp. 1187-1195
-
-
Shirato, H.1
Shimizu, S.2
Kunieda, T.3
-
14
-
-
0347625747
-
Validation of target volume and position in respiratory gated CT planning and treatment
-
S. Shen, J. Duan, and J.B. Fiveash Validation of target volume and position in respiratory gated CT planning and treatment Med Phys 30 2003 3196 3205
-
(2003)
Med Phys
, vol.30
, pp. 3196-3205
-
-
Shen, S.1
Duan, J.2
Fiveash, J.B.3
-
15
-
-
70349315241
-
Initial validations for pursuing irradiation using a gimbals tracking system
-
K. Takayama, T. Mizowaki, and M. Kokubo Initial validations for pursuing irradiation using a gimbals tracking system Radiother Oncol 93 2009 45 49
-
(2009)
Radiother Oncol
, vol.93
, pp. 45-49
-
-
Takayama, K.1
Mizowaki, T.2
Kokubo, M.3
-
16
-
-
69249223062
-
Target-tracking deliveries on an Elekta linac: A feasibility study
-
D. McQuaid, M. Partridge, and J.R. Symonds-Tayler Target-tracking deliveries on an Elekta linac: A feasibility study Phys Med Biol 54 2009 3563 3578
-
(2009)
Phys Med Biol
, vol.54
, pp. 3563-3578
-
-
McQuaid, D.1
Partridge, M.2
Symonds-Tayler, J.R.3
-
17
-
-
42949109604
-
Management of three dimensional intrafraction motion through real-time DMLC tracking
-
A. Sawant, R. Venkat, and V. Srivastava Management of three dimensional intrafraction motion through real-time DMLC tracking Med Phys 35 2008 2050 2061
-
(2008)
Med Phys
, vol.35
, pp. 2050-2061
-
-
Sawant, A.1
Venkat, R.2
Srivastava, V.3
-
18
-
-
75749118592
-
Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC
-
M.B. Tacke, S. Nill, and A. Krauss Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC Med Phys 37 2010 753 761
-
(2010)
Med Phys
, vol.37
, pp. 753-761
-
-
Tacke, M.B.1
Nill, S.2
Krauss, A.3
-
19
-
-
0141520680
-
Evaluation of the gamma dose distribution comparison method
-
D.A. Low, and J.F. Dempsey Evaluation of the gamma dose distribution comparison method Med Phys 30 2003 2455 2464
-
(2003)
Med Phys
, vol.30
, pp. 2455-2464
-
-
Low, D.A.1
Dempsey, J.F.2
-
20
-
-
20044373291
-
Compensation for respiratory motion by gated radiotherapy: An experimental study
-
L. Dietrich, T. Tucking, and S. Nill Compensation for respiratory motion by gated radiotherapy: An experimental study Phys Med Biol 50 2005 2405 2414
-
(2005)
Phys Med Biol
, vol.50
, pp. 2405-2414
-
-
Dietrich, L.1
Tucking, T.2
Nill, S.3
-
21
-
-
0032941481
-
A method for incorporating organ motion due to breathing into 3D dose calculations
-
A.E. Lujan, E.W. Larsen, and J.M. Balter A method for incorporating organ motion due to breathing into 3D dose calculations Med Phys 26 1999 715 720
-
(1999)
Med Phys
, vol.26
, pp. 715-720
-
-
Lujan, A.E.1
Larsen, E.W.2
Balter, J.M.3
-
22
-
-
65449175240
-
Toward submillimeter accuracy in the management of intrafraction motion: The integration of real-time internal position monitoring and multileaf collimator target tracking
-
A. Sawant, R.L. Smith, and R.B. Venkat Toward submillimeter accuracy in the management of intrafraction motion: The integration of real-time internal position monitoring and multileaf collimator target tracking Int J Radiat Oncol Biol Phys 74 2009 575 582
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 575-582
-
-
Sawant, A.1
Smith, R.L.2
Venkat, R.B.3
-
23
-
-
64049103804
-
Clinical accuracy of the respiratory tumor tracking system of the CyberKnife: Assessment by analysis of log files
-
M. Hoogeman, J.B. Prevost, and J. Nuyttens Clinical accuracy of the respiratory tumor tracking system of the CyberKnife: Assessment by analysis of log files Int J Radiat Oncol Biol Phys 74 2009 297 303
-
(2009)
Int J Radiat Oncol Biol Phys
, vol.74
, pp. 297-303
-
-
Hoogeman, M.1
Prevost, J.B.2
Nuyttens, J.3
-
24
-
-
33846853755
-
Comparative performance of linear and nonlinear neural networks to predict irregular breathing
-
M.J. Murphy, and S. Dieterich Comparative performance of linear and nonlinear neural networks to predict irregular breathing Phys Med Biol 51 2006 5903 5914
-
(2006)
Phys Med Biol
, vol.51
, pp. 5903-5914
-
-
Murphy, M.J.1
Dieterich, S.2
-
25
-
-
76849090485
-
Kernel density estimation-based real-time prediction for respiratory motion
-
D. Ruan Kernel density estimation-based real-time prediction for respiratory motion Phys Med Biol 55 2010 1311 1326
-
(2010)
Phys Med Biol
, vol.55
, pp. 1311-1326
-
-
Ruan, D.1
-
26
-
-
65449128567
-
Development of a non-migrating electromagnetic transponder system for lung tumor tracking
-
M.L. Mayse, R.L. Smith, and M. Park Development of a non-migrating electromagnetic transponder system for lung tumor tracking Int J Radiat Oncol Biol Phys 72 2008 S430
-
(2008)
Int J Radiat Oncol Biol Phys
, vol.72
, pp. 430
-
-
Mayse, M.L.1
Smith, R.L.2
Park, M.3
-
27
-
-
47649105316
-
Synchronized tumour tracking with electromagnetic transponders and kV x-ray imaging: Evaluation based on a thorax phantom
-
A.W. Rau, S. Nill, and R.S. Eidens Synchronized tumour tracking with electromagnetic transponders and kV x-ray imaging: Evaluation based on a thorax phantom Phys Med Biol 53 2008 3789 3805
-
(2008)
Phys Med Biol
, vol.53
, pp. 3789-3805
-
-
Rau, A.W.1
Nill, S.2
Eidens, R.S.3
|