메뉴 건너뛰기




Volumn , Issue , 2010, Pages 3317-3320

DWI acquisition schemes and Diffusion Tensor estimation: A simulation-based study

Author keywords

[No Author keywords available]

Indexed keywords

ACQUISITION PROCESS; DIFFUSION TENSOR; DIFFUSION TENSOR IMAGING; DIFFUSION WEIGHTED IMAGES; DIFFUSION-WEIGHTED MAGNETIC RESONANCE IMAGING; DT ESTIMATION; GAUSSIANS; LEAST SQUARE; MULTIPLE COILS; SIMULATION-BASED;

EID: 78650847857     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2010.5627492     Document Type: Conference Paper
Times cited : (3)

References (13)
  • 1
    • 33750363336 scopus 로고    scopus 로고
    • Geometrically constrained two-tensor model for crossing tracts in DWI
    • S. Peled et al., "Geometrically constrained two-tensor model for crossing tracts in DWI," Magn. Reson. Imag., vol. 24, no. 9, pp. 1263 - 1270, 2006.
    • (2006) Magn. Reson. Imag. , vol.24 , Issue.9 , pp. 1263-1270
    • Peled, S.1
  • 2
    • 13444270481 scopus 로고    scopus 로고
    • Formal characterization and extension of the linearized diffusion tensor model
    • Feb.
    • R. Salvador et al., "Formal characterization and extension of the linearized diffusion tensor model," Human brain mapping, vol. 24, pp. 144-155, Feb. 2005.
    • (2005) Human Brain Mapping , vol.24 , pp. 144-155
    • Salvador, R.1
  • 3
    • 84883741342 scopus 로고    scopus 로고
    • Bias of least squares approaches for diffusion tensor estimation from array coils in DTMRI
    • A. Tristán-Vega, C.-F. Westin, and S. Aja-Fernández, "Bias of least squares approaches for diffusion tensor estimation from array coils in DTMRI," in MICCAI 2009, 2009, pp. 919-926.
    • (2009) MICCAI 2009 , pp. 919-926
    • Tristán-Vega, A.1    Westin, C.-F.2    Aja-Fernández, S.3
  • 5
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • Nov.
    • K. P. Pruessmann et al., "SENSE: Sensitivity encoding for fast MRI," Magn. Reson. Med., vol. 42, no. 5, pp. 952-62, Nov. 1999.
    • (1999) Magn. Reson. Med. , vol.42 , Issue.5 , pp. 952-962
    • Pruessmann, K.P.1
  • 6
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • M. A. Griswold et al., "Generalized autocalibrating partially parallel acquisitions (GRAPPA)," Magn. Reson. Med., vol. 47, no. 6, pp. 1202-1210, 2002.
    • (2002) Magn. Reson. Med. , vol.47 , Issue.6 , pp. 1202-1210
    • Griswold, M.A.1
  • 7
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • H. Gudbjartsson and S. Patz, "The Rician distribution of noisy MRI data," Magn. Reson. Med., vol. 34, pp. 910-914, 1995.
    • (1995) Magn. Reson. Med. , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 8
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR hased arrays
    • C. Constantinides, E. Atalar, and E. McVeigh, "Signal-to-noise measurements in magnitude images from NMR hased arrays," Magn. Reson. Med., vol. 38, pp. 852-857, 1997.
    • (1997) Magn. Reson. Med. , vol.38 , pp. 852-857
    • Constantinides, C.1    Atalar, E.2    McVeigh, E.3
  • 9
    • 45849103511 scopus 로고    scopus 로고
    • Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics
    • O. Dietrich et al., "Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics," Magn. Reson. Imag., vol. 26, pp. 754-762, 2008.
    • (2008) Magn. Reson. Imag. , vol.26 , pp. 754-762
    • Dietrich, O.1
  • 11
    • 52649095997 scopus 로고    scopus 로고
    • Restoration of DWI data using a Rician LMMSE estimator
    • S. Aja-Fernandez et al., "Restoration of DWI data using a Rician LMMSE estimator," IEEE Trans. Med. Imaging, vol. 27, no. 10, pp. 1389-1403, 2008.
    • (2008) IEEE Trans. Med. Imaging , vol.27 , Issue.10 , pp. 1389-1403
    • Aja-Fernandez, S.1
  • 12
    • 69449103174 scopus 로고    scopus 로고
    • General formulation for quantitative g-factor calculation in grappa reconstructions
    • F. A. Breuer et al., "General formulation for quantitative g-factor calculation in grappa reconstructions," Magn. Reson. Med., vol. 62, no. 3, pp. 739-746, 2009.
    • (2009) Magn. Reson. Med. , vol.62 , Issue.3 , pp. 739-746
    • Breuer, F.A.1
  • 13
    • 84864851554 scopus 로고    scopus 로고
    • Design and construction of a realistic DWI phantom for filtering performance assessment
    • A. Tristán-Vega and S. Aja-Fernández, "Design and construction of a realistic DWI phantom for filtering performance assessment," in MICCAI 2009, 2009, pp. 951-958.
    • (2009) MICCAI 2009 , pp. 951-958
    • Tristán-Vega, A.1    Aja-Fernández, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.