메뉴 건너뛰기




Volumn 5761 LNCS, Issue PART 1, 2009, Pages 919-926

Bias of least squares approaches for diffusion tensor estimation from array coils in DT-MRI

Author keywords

[No Author keywords available]

Indexed keywords

DIFFUSION TENSOR; DIFFUSION WEIGHTED IMAGES; DT ESTIMATION; LEAST SQUARES; LEAST-SQUARES APPROACH; MULTIPLE ARRAYS; MULTIPLE COILS; NOISE ANALYSIS; NOISE MODELS; NOISE STATISTICS; PARALLEL IMAGING; UNBIASED FILTERING;

EID: 84883741342     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-04268-3_113     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 1
    • 13444270481 scopus 로고    scopus 로고
    • Formal characterization and extension of the linearized diffusion tensor model
    • DOI 10.1002/hbm.20076
    • Salvador, R., Pea, A.,Menon, D.K., Carpenter, T.A., Pickard, J.D., Bullmore, E.T.: Formal characterization and extension of the linearized diffusion tensor model. Human Brain Mapping 24, 144-155 (2005) (Pubitemid 40205120)
    • (2005) Human Brain Mapping , vol.24 , Issue.2 , pp. 144-155
    • Salvador, R.1    Pena, A.2    Menon, D.K.3    Carpenter, T.A.4    Pickard, J.D.5    Bullmore, E.T.6
  • 2
    • 35648969603 scopus 로고    scopus 로고
    • Clinical DT-MRI estimation, smoothing, and fiber tracking with log-euclidean metrics
    • Fillard, P., Pennec, X., Arsigny, V., Ayache, N.: Clinical DT-MRI estimation, smoothing, and fiber tracking with log-euclidean metrics. IEEE Trans. Med. Imaging 26(11), 1472-1482 (2007)
    • (2007) IEEE Trans. Med. Imaging , vol.26 , Issue.11 , pp. 1472-1482
    • Fillard, P.1    Pennec, X.2    Arsigny, V.3    Ayache, N.4
  • 3
    • 0028839871 scopus 로고
    • The Rician distribution of noisy MRI data
    • Gudbjartsson, H., Patz, S.: The Rician distribution of noisy MRI data. Magn. Reson. Med. 34, 910-914 (1995)
    • (1995) Magn. Reson. Med. , vol.34 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 5
    • 0030726766 scopus 로고    scopus 로고
    • Signal-to-noise measurements in magnitude images from NMR phased arrays
    • Constantinides, C., Atalar, E., McVeigh, E.: Signal-to-noise measurements in magnitude images from NMR phased arrays. Magn. Reson. Med. 38, 852-857 (1997)
    • (1997) Magn. Reson. Med. , vol.38 , pp. 852-857
    • Constantinides, C.1    Atalar, E.2    McVeigh, E.3
  • 6
    • 35648934022 scopus 로고    scopus 로고
    • Impact of an improved combination of signal from array coils in diffusion tensor imaging
    • Gilbert, G., Simard, D., Beaudoin, G.: Impact of an improved combination of signal from array coils in diffusion tensor imaging. IEEE Trans. Med. Imaging 26(11), 1428-1436 (2007)
    • (2007) IEEE Trans. Med. Imaging , vol.26 , Issue.11 , pp. 1428-1436
    • Gilbert, G.1    Simard, D.2    Beaudoin, G.3
  • 7
    • 79953652334 scopus 로고    scopus 로고
    • SignalLMMSEestimationfrom multiple samples inMRI andDT-MRI
    • Ayache,N.,Ourselin, S., Maeder,A. (eds.) MICCAI 2007, Springer, Heidelberg
    • Aja-Fernández, S.,Alberola-López,C.,Westin,C.-F.: SignalLMMSEestimationfrom multiple samples inMRI andDT-MRI. In:Ayache,N., Ourselin, S., Maeder,A. (eds.) MICCAI 2007, Part II. LNCS, vol. 4792, pp. 368-375. Springer, Heidelberg (2007)
    • (2007) LNCS , vol.4792 , Issue.PART II , pp. 368-375
    • Aja-Fernández, S.1    Alberola-López, C.2    Westin, C.-F.3
  • 8
    • 84883836598 scopus 로고    scopus 로고
    • Rician noise removal in diffusion tensor MRI
    • Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. Springer, Heidelberg
    • Basu, S., Fletcher, T., Whitaker, R.T.: Rician noise removal in diffusion tensor MRI. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol. 4190, pp. 117-125. Springer, Heidelberg (2006)
    • (2006) LNCS , vol.4190 , pp. 117-125
    • Basu, S.1    Fletcher, T.2    Whitaker, R.T.3
  • 9
    • 79551689837 scopus 로고    scopus 로고
    • Impact of rician adapted non-local means filtering on HARDI
    • Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Springer, Heidelberg
    • Descoteaux, M., Wiest-Daesslé, N., Prima, S., Barillot, C., Deriche, R.: Impact of rician adapted non-local means filtering on HARDI. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. LNCS, vol. 5242, pp. 122-130. Springer, Heidelberg (2008)
    • (2008) LNCS , vol.5242 , Issue.PART II , pp. 122-130
    • Descoteaux, M.1    Wiest-Daesslé, N.2    Prima, S.3    Barillot, C.4    Deriche, R.5
  • 10
    • 84883838668 scopus 로고    scopus 로고
    • Rician noise removal by non-local means filtering for low signal-to-noise ratio MRI: Applications to DT-MRI
    • Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Springer, Heidelberg
    • Wiest-Daesslé, N., Prima, S., Coupé, P., Morrissey, S.P., Barillot, C.: Rician noise removal by non-local means filtering for low signal-to-noise ratio MRI: Applications to DT-MRI. In: Metaxas, D., Axel, L., Fichtinger, G., Székely, G. (eds.) MICCAI 2008, Part II. LNCS, vol. 5242, pp. 171-179. Springer, Heidelberg (2008)
    • (2008) LNCS , vol.5242 , Issue.PART II , pp. 171-179
    • Wiest-Daesslé, N.1    Prima, S.2    Coupé, P.3    Morrissey, S.P.4    Barillot, C.5
  • 11
    • 33646376290 scopus 로고
    • Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient
    • Stejskal, E.O., Tanner, J.E.: Spin diffusion measurements: Spin echoes in the presence of a time-dependent field gradient. J. of Chem. Phys. 42, 288-292 (1965)
    • (1965) J. of Chem. Phys. , vol.42 , pp. 288-292
    • Stejskal, E.O.1    Tanner, J.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.