메뉴 건너뛰기




Volumn 25, Issue 1, 2011, Pages 11-17

A prospective clinical study of proximal humerus fractures treated with a locking proximal humerus plate

Author keywords

fracture; locking proximal humerus plate; plate fixation; proximal humerus

Indexed keywords

ADULT; ARTICLE; BONE PLATE; BONE SCREW; CLINICAL TRIAL; FEMALE; FROZEN SHOULDER; HUMAN; HUMERUS FRACTURE; MAJOR CLINICAL STUDY; MALE; ORTHOPEDIC SURGERY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; ROTATOR CUFF RUPTURE; SHOULDER IMPINGEMENT SYNDROME; TREATMENT OUTCOME; WOUND DEHISCENCE;

EID: 78650782607     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/BOT.0b013e3181d2d04c     Document Type: Article
Times cited : (59)

References (29)
  • 1
    • 0024384196 scopus 로고
    • The epidemiology of fractures of the proximal humerus
    • Lind T, Kroner K, Jensen J. The epidemiology of fractures of the proximal humerus. Arch Orthop Trauma Surg. 1989;108:285-287.
    • (1989) Arch Orthop Trauma Surg. , vol.108 , pp. 285-287
    • Lind, T.1    Kroner, K.2    Jensen, J.3
  • 2
    • 33645046408 scopus 로고    scopus 로고
    • New trends in the treatment of proximal humerus fractures
    • Helmy N, Hintermann B. New trends in the treatment of proximal humerus fractures. CORR. 2006;442:100-108.
    • (2006) CORR. , vol.442 , pp. 100-108
    • Helmy, N.1    Hintermann, B.2
  • 3
    • 33745994558 scopus 로고    scopus 로고
    • Epidemiology of adult fractures: A review
    • Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37:691-697.
    • (2006) Injury. , vol.37 , pp. 691-697
    • Court-Brown, C.M.1    Caesar, B.2
  • 4
    • 0032104660 scopus 로고    scopus 로고
    • Non-operative treatment of comminuted fractures of the proximal humerus in elderly patients
    • Zyto K. Non-operative treatment of comminuted fractures of the proximal humerus in elderly patients. Injury. 1998;29:349-352.
    • (1998) Injury. , vol.29 , pp. 349-352
    • Zyto, K.1
  • 5
    • 7444234973 scopus 로고    scopus 로고
    • Innovations in locking plate technology
    • Haidukewych GJ. Innovations in locking plate technology. J Am Acad Orthop Surg. 2004;12:205-212.
    • (2004) J Am Acad Orthop Surg. , vol.12 , pp. 205-212
    • Haidukewych, G.J.1
  • 6
    • 0142138198 scopus 로고    scopus 로고
    • Guidelines for the clinical application of the LCP
    • Gautier E, Sommer C.Guidelines for the clinical application of the LCP. Injury. 2003;34(Suppl 2):B63-B76.
    • (2003) Injury. , vol.34 , Issue.SUPPL. 2
    • Gautier, E.1    Sommer, C.2
  • 7
    • 34047109352 scopus 로고    scopus 로고
    • Innovations in the management of displaced proximal humerus fractures
    • Nho SJ, Brophy RH, Barker JU, et al. Innovations in the management of displaced proximal humerus fractures. J Am Acad Orthop Surg. 2007;15: 12-26.
    • (2007) J Am Acad Orthop Surg. , vol.15 , pp. 12-26
    • Nho, S.J.1    Brophy, R.H.2    Barker, J.U.3
  • 8
    • 33947588573 scopus 로고    scopus 로고
    • Locking plate fixation for proximal humeral fractures: Initial results with a new implant
    • Rose PS, Adams CR, Torchia ME, et al. Locking plate fixation for proximal humeral fractures: Initial results with a new implant. J Shoulder Elbow Surg. 2007;16:202-207.
    • (2007) J Shoulder Elbow Surg. , vol.16 , pp. 202-207
    • Rose, P.S.1    Adams, C.R.2    Torchia, M.E.3
  • 9
    • 0042463687 scopus 로고    scopus 로고
    • Four-segment classification of proximal humeral fractures: Purpose and reliable use
    • Neer CS 2nd. Four-segment classification of proximal humeral fractures: Purpose and reliable use. J Shoulder Elbow Surg. 2002;11:389-400.
    • (2002) J Shoulder Elbow Surg. , vol.11 , pp. 389-400
    • Neer II, C.S.1
  • 10
    • 0141452006 scopus 로고    scopus 로고
    • Severely impacted valgus proximal humeral fractures. Results of operative treatment
    • Robinson CM, Page RS. Severely impacted valgus proximal humeral fractures. Results of operative treatment. J Bone Joint Surg Am. 2003;85: 1647-1655.
    • (2003) J Bone Joint Surg Am. , vol.85 , pp. 1647-1655
    • Robinson, C.M.1    Page, R.S.2
  • 11
    • 44649100754 scopus 로고    scopus 로고
    • Extent of osteonecrosis on MRI predicts humeral head collapse
    • Sakai T, Sugano N, Nishii T, et al. Extent of osteonecrosis on MRI predicts humeral head collapse. Clin Orthop Relat Res. 2008;466:1074-1080.
    • (2008) Clin Orthop Relat Res. , vol.466 , pp. 1074-1080
    • Sakai, T.1    Sugano, N.2    Nishii, T.3
  • 12
    • 34247563357 scopus 로고    scopus 로고
    • The importance of medial support in locked plating of proximal humerus fractures
    • Gardner MJ,Weil Y, Barker JU, et al. The importance of medial support in locked plating of proximal humerus fractures. J Orthop Trauma. 2007;21: 185-191.
    • (2007) J Orthop Trauma. , vol.21 , pp. 185-191
    • Gardner, M.J.1    Weil, Y.2    Barker, J.U.3
  • 13
    • 0023115201 scopus 로고
    • A clinical method of functional assessment of the shoulder
    • Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987;214:160-164.
    • (1987) Clin Orthop Relat Res. , vol.214 , pp. 160-164
    • Constant, C.R.1    Murley, A.H.2
  • 14
    • 39749142078 scopus 로고    scopus 로고
    • Current concepts in the treatment of proximal humeral fractures
    • Fakler JK, Hogan C, Heyde CE, et al. Current concepts in the treatment of proximal humeral fractures. Orthopedics. 2008;31:42-51.
    • (2008) Orthopedics. , vol.31 , pp. 42-51
    • Fakler, J.K.1    Hogan, C.2    Heyde, C.E.3
  • 15
    • 0142199888 scopus 로고    scopus 로고
    • General principles for the clinical use of the LCP
    • Wagner M. General principles for the clinical use of the LCP. Injury. 2003; 34(Suppl 2):B31-B42.
    • (2003) Injury. , vol.34 , Issue.SUPPL. 2
    • Wagner, M.1
  • 16
    • 11844254362 scopus 로고    scopus 로고
    • A new locking plate for unstable fractures of the proximal humerus
    • Fankhauser F, Boldin C, Schippinger G, et al. A new locking plate for unstable fractures of the proximal humerus. Clin Orthop Relat Res. 2005; 430:176-181.
    • (2005) Clin Orthop Relat Res. , vol.430 , pp. 176-181
    • Fankhauser, F.1    Boldin, C.2    Schippinger, G.3
  • 17
    • 33645064868 scopus 로고    scopus 로고
    • Fixation of proximal humerus fractures using the PHILOS plate: Early experience
    • Koukakis A, Apostolou CD, Taneja T, et al. Fixation of proximal humerus fractures using the PHILOS plate: Early experience. Clin Orthop Relat Res. 2006;442:115-120.
    • (2006) Clin Orthop Relat Res. , vol.442 , pp. 115-120
    • Koukakis, A.1    Apostolou, C.D.2    Taneja, T.3
  • 18
    • 56149111888 scopus 로고    scopus 로고
    • Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital
    • Shahid R, Mushtaq A, Northover J, et al. Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital. Acta Orthop Belg. 2008;74:602-608.
    • (2008) Acta Orthop Belg. , vol.74 , pp. 602-608
    • Shahid, R.1    Mushtaq, A.2    Northover, J.3
  • 19
    • 61549111874 scopus 로고    scopus 로고
    • Locked plating of 3- and 4-part proximal humerus fractures in older patients: The effect of initial fracture pattern on outcome
    • Solberg BD, Moon CN, Franco DP, et al. Locked plating of 3- and 4-part proximal humerus fractures in older patients: The effect of initial fracture pattern on outcome. J Orthop Trauma. 2009;23:113-119.
    • (2009) J Orthop Trauma. , vol.23 , pp. 113-119
    • Solberg, B.D.1    Moon, C.N.2    Franco, D.P.3
  • 20
    • 35948976112 scopus 로고    scopus 로고
    • Analysis of efficacy and failure in proximal humerus fractures treated with locking plates
    • Agudelo J, Schürmann M, Stahel P, et al. Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J Orthop Trauma. 2007;21:676-681.
    • (2007) J Orthop Trauma. , vol.21 , pp. 676-681
    • Agudelo, J.1    Schürmann, M.2    Stahel, P.3
  • 21
    • 38949117338 scopus 로고    scopus 로고
    • Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]
    • Owsley KC, Gorczyca JT. Fracture displacement and screw cutout after open reduction and locked plate fixation of proximal humeral fractures [corrected]. Bone Joint Surg Am. 2008;90:233-240.
    • (2008) Bone Joint Surg Am. , vol.90 , pp. 233-240
    • Owsley, K.C.1    Gorczyca, J.T.2
  • 22
    • 0027740198 scopus 로고
    • The reproducibility of classification of fractures of the proximal end of the humerus
    • Siebenrock KA, Gerber C. The reproducibility of classification of fractures of the proximal end of the humerus. J Bone Joint Surg Am. 1993; 75:1751-1755.
    • (1993) J Bone Joint Surg Am. , vol.75 , pp. 1751-1755
    • Siebenrock, K.A.1    Gerber, C.2
  • 23
    • 43249095676 scopus 로고    scopus 로고
    • Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates
    • Egol KA, Ong CC, Walsh M, et al. Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates. J Orthop Trauma. 2008;22:159-164.
    • (2008) J Orthop Trauma. , vol.22 , pp. 159-164
    • Egol, K.A.1    Ong, C.C.2    Walsh, M.3
  • 24
    • 10944263139 scopus 로고    scopus 로고
    • Internal fixation of proximal humeral fractures with a locking compression plate: A retrospective evaluation of 72 patients followed for a minimum of 1 year
    • Björkenheim JM, Pajarinen J, Savolainen V. Internal fixation of proximal humeral fractures with a locking compression plate: A retrospective evaluation of 72 patients followed for a minimum of 1 year. Acta Orthop Scand. 2004;75:741-745.
    • (2004) Acta Orthop Scand. , vol.75 , pp. 741-745
    • Björkenheim, J.M.1    Pajarinen, J.2    Savolainen, V.3
  • 25
    • 14944348757 scopus 로고    scopus 로고
    • Internal fixation of proximal humerus fractures using the locking proximal humerus plate
    • Plecko M, Kraus A. Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Oper Orthop Traumatol. 2005;17: 25-50.
    • (2005) Oper Orthop Traumatol. , vol.17 , pp. 25-50
    • Plecko, M.1    Kraus, A.2
  • 26
    • 41749111405 scopus 로고    scopus 로고
    • A new osteosynthesis device for the treatment of proximal humerus fractures. Description of the technique and preliminary results
    • Russo R, Lombardi LV, Ciccarelli M, et al. A new osteosynthesis device for the treatment of proximal humerus fractures. Description of the technique and preliminary results. Chir Organi Mov. 2008;91: 27-34.
    • (2008) Chir Organi Mov. , vol.91 , pp. 27-34
    • Russo, R.1    Lombardi, L.V.2    Ciccarelli, M.3
  • 27
    • 0021365109 scopus 로고
    • Complications about the glenohumeral joint related to the use of screws and staples
    • Zuckerman JD, Matsen FA 3rd. Complications about the glenohumeral joint related to the use of screws and staples. J Bone Joint Surg Am. 1984; 66:175-180.
    • (1984) J Bone Joint Surg Am. , vol.66 , pp. 175-180
    • Zuckerman, J.D.1    Matsen III, F.A.2
  • 29
    • 0029738607 scopus 로고    scopus 로고
    • Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder and hand) [corrected]
    • The Upper Extremity Collaborative Group (UECG)
    • Hudak PL, Amadio PC, Bombardier C. Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG). Am J Ind Med. 1996;29:602-608.
    • (1996) Am J Ind Med. , vol.29 , pp. 602-608
    • Hudak, P.L.1    Amadio, P.C.2    Bombardier, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.