메뉴 건너뛰기




Volumn 16, Issue 1, 2011, Pages 13-18

Intra-dialytic hypotension and blood volume and blood temperature monitoring

Author keywords

blood pressure; blood temperature monitoring; blood volume monitoring; haemodialysis; intra dialytic hypotension

Indexed keywords

ARTICLE; BLOOD VOLUME; HEMODIALYSIS; HUMAN; HYPOTENSION; INTRA DIALYTIC HYPOTENSION; PATIENT MONITORING; PRIORITY JOURNAL; RISK FACTOR; TEMPERATURE MEASUREMENT; THERMOREGULATION; ULTRAFILTRATION;

EID: 78650641786     PISSN: 13205358     EISSN: 14401797     Source Type: Journal    
DOI: 10.1111/j.1440-1797.2010.01362.x     Document Type: Article
Times cited : (21)

References (58)
  • 1
    • 23844465424 scopus 로고    scopus 로고
    • K/DOQI clinical practice guidelines for cardiovascular disease in dialysis patients
    • NKF
    • NKF. K/DOQI clinical practice guidelines for cardiovascular disease in dialysis patients. Am. J. Kidney Dis. 2005; 45 (4 Suppl 3): S1-153.
    • (2005) Am. J. Kidney Dis. , vol.45 , Issue.4 SUPPL. 3
  • 2
    • 33745615802 scopus 로고    scopus 로고
    • A systematic review of the clinical effects of reducing dialysate fluid temperature
    • Selby NM, McIntyre CW,. A systematic review of the clinical effects of reducing dialysate fluid temperature. Nephrol. Dial. Transplant. 2006; 21 (7): 1883-98.
    • (2006) Nephrol. Dial. Transplant. , vol.21 , Issue.7 , pp. 1883-1898
    • Selby, N.M.1    McIntyre, C.W.2
  • 3
    • 4344704654 scopus 로고    scopus 로고
    • Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients
    • Shoji T, Tsubakihara Y, Fujii M, Imai E,. Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients. Kidney Int. 2004; 66 (3): 1212-20.
    • (2004) Kidney Int. , vol.66 , Issue.3 , pp. 1212-1220
    • Shoji, T.1    Tsubakihara, Y.2    Fujii, M.3    Imai, E.4
  • 4
    • 33847202893 scopus 로고    scopus 로고
    • Association of intradialytic blood pressure changes with hospitalization and mortality rates in prevalent ESRD patients
    • Inrig JK, Oddone EZ, Hasselblad V, et al. Association of intradialytic blood pressure changes with hospitalization and mortality rates in prevalent ESRD patients. Kidney Int. 2007; 71: 454-61.
    • (2007) Kidney Int. , vol.71 , pp. 454-461
    • Inrig, J.K.1    Oddone, E.Z.2    Hasselblad, V.3
  • 5
    • 0034780316 scopus 로고    scopus 로고
    • Pathophysiology of dialysis hypotension: An update
    • Daugirdas JT,. Pathophysiology of dialysis hypotension: An update. Am. J. Kidney Dis. 2001; 38 (4 Suppl 4): S11-17.
    • (2001) Am. J. Kidney Dis. , vol.38 , Issue.4 SUPPL. 4
    • Daugirdas, J.T.1
  • 7
    • 0038691523 scopus 로고    scopus 로고
    • Characteristics of hypotension-prone haemodialysis patients: Is there a critical relative blood volume?
    • Barth C, Boer W, Garzoni D, et al. Characteristics of hypotension-prone haemodialysis patients: Is there a critical relative blood volume? Nephrol. Dial. Transplant. 2003; 18: 1353-60.
    • (2003) Nephrol. Dial. Transplant. , vol.18 , pp. 1353-1360
    • Barth, C.1    Boer, W.2    Garzoni, D.3
  • 8
    • 27144558791 scopus 로고    scopus 로고
    • Automatic feedback control of relative blood volume changes during hemodialysis improves blood pressure stability during and after dialysis
    • Franssen CF, Dasselaar JJ, Sytsma P, Burgerhof JG, de Jong PE, Huisman RM,. Automatic feedback control of relative blood volume changes during hemodialysis improves blood pressure stability during and after dialysis. Hemodial. Int. 2005; 9: 383-92.
    • (2005) Hemodial. Int. , vol.9 , pp. 383-392
    • Franssen, C.F.1    Dasselaar, J.J.2    Sytsma, P.3    Burgerhof, J.G.4    De Jong, P.E.5    Huisman, R.M.6
  • 9
    • 10944220189 scopus 로고    scopus 로고
    • Hypertension and survival in chronic hemodialysis patients - Past lessons and future opportunities
    • Agarwal R,. Hypertension and survival in chronic hemodialysis patients-Past lessons and future opportunities. Kidney Int. 2005; 67 (1): 1-13.
    • (2005) Kidney Int. , vol.67 , Issue.1 , pp. 1-13
    • Agarwal, R.1
  • 10
    • 34249986069 scopus 로고    scopus 로고
    • The acute cardiac effects of dialysis
    • Selby NM, McIntyre CW,. The acute cardiac effects of dialysis. Semin. Dial. 2007; 20: 220-28.
    • (2007) Semin. Dial. , vol.20 , pp. 220-228
    • Selby, N.M.1    McIntyre, C.W.2
  • 11
    • 48049101411 scopus 로고    scopus 로고
    • Hypertrophy and fibrosis in the cardiomyopathy of uremia - Beyond coronary heart disease
    • Gross ML, Ritz E,. Hypertrophy and fibrosis in the cardiomyopathy of uremia-Beyond coronary heart disease. Semin. Dial. 2008; 21: 308-18.
    • (2008) Semin. Dial. , vol.21 , pp. 308-318
    • Gross, M.L.1    Ritz, E.2
  • 13
    • 0033154894 scopus 로고    scopus 로고
    • The role of technology in hemodialysis
    • Ronco C, Ghezzi PM, La Greca G,. The role of technology in hemodialysis. J. Nephrol. 1999; 12 (Suppl 2): S68-81.
    • (1999) J. Nephrol. , vol.12 , Issue.2 SUPPL.
    • Ronco, C.1    Ghezzi, P.M.2    La Greca, G.3
  • 15
    • 67649625309 scopus 로고    scopus 로고
    • Can advances in hemodialysis machine technology prevent intradialytic hypotension?
    • Davenport A,. Can advances in hemodialysis machine technology prevent intradialytic hypotension? Semin. Dial. 2009; 22: 231-6.
    • (2009) Semin. Dial. , vol.22 , pp. 231-236
    • Davenport, A.1
  • 16
    • 57749175308 scopus 로고    scopus 로고
    • The advantages and challenges of increasing the duration and frequency of maintenance dialysis sessions
    • Chazot C, Jean G,. The advantages and challenges of increasing the duration and frequency of maintenance dialysis sessions. Nat. Clin. Pract. Nephrol. 2009; 5 (1): 34-44.
    • (2009) Nat. Clin. Pract. Nephrol. , vol.5 , Issue.1 , pp. 34-44
    • Chazot, C.1    Jean, G.2
  • 19
    • 46249115716 scopus 로고    scopus 로고
    • Can extracellular fluid volume expansion in hemodialysis patients be safely reduced using the hemocontrol biofeedback algorithm? A randomized trial
    • Nesrallah GE, Suri RS, Thiessen-Philbrook H, Heidenheim P, Lindsay RM,. Can extracellular fluid volume expansion in hemodialysis patients be safely reduced using the hemocontrol biofeedback algorithm? A randomized trial. ASAIO J. 2008; 54: 270-74.
    • (2008) ASAIO J. , vol.54 , pp. 270-274
    • Nesrallah, G.E.1    Suri, R.S.2    Thiessen-Philbrook, H.3    Heidenheim, P.4    Lindsay, R.M.5
  • 20
    • 0031872990 scopus 로고    scopus 로고
    • Enhanced fluid removal guided by blood volume monitoring during chronic hemodialysis
    • Steuer RR, Germain MJ, Leypoldt JK, Cheung AK,. Enhanced fluid removal guided by blood volume monitoring during chronic hemodialysis. Artif. Organs 1998; 22: 627-32.
    • (1998) Artif. Organs , vol.22 , pp. 627-632
    • Steuer, R.R.1    Germain, M.J.2    Leypoldt, J.K.3    Cheung, A.K.4
  • 21
    • 0036895459 scopus 로고    scopus 로고
    • The role of blood volume reduction in the genesis of intradialytic hypotension
    • Andrulli S, Colzani S, Mascia F, et al. The role of blood volume reduction in the genesis of intradialytic hypotension. Am. J. Kidney Dis. 2002; 40 (6): 1244-54.
    • (2002) Am. J. Kidney Dis. , vol.40 , Issue.6 , pp. 1244-1254
    • Andrulli, S.1    Colzani, S.2    Mascia, F.3
  • 22
    • 0027381935 scopus 로고
    • Non-invasive monitoring of blood volume during hemodialysis: Its relation with post-dialytic dry weight
    • de Vries JPPM, Kouw PM, Van der Meer NJ, Olthof CG, Oe LP, de Vries PMJM,. Non-invasive monitoring of blood volume during hemodialysis: Its relation with post-dialytic dry weight. Kideny Int. 1993; 44: 851-4.
    • (1993) Kideny Int. , vol.44 , pp. 851-854
    • De Vries, J.1    Kouw, P.M.2    Van Der Meer, N.J.3    Olthof, C.G.4    Oe, L.P.5    De Vries, P.6
  • 24
    • 0028464341 scopus 로고
    • Hematocrit as an indicator of blood volume and a predictor of intradialytic morbid events
    • Steuer RR, Leypoldt JK, Cheung AK, Harris DH, Conis JM,. Hematocrit as an indicator of blood volume and a predictor of intradialytic morbid events. ASAIO J. 1994; 40 (3): M691-6.
    • (1994) ASAIO J. , vol.40 , Issue.3
    • Steuer, R.R.1    Leypoldt, J.K.2    Cheung, A.K.3    Harris, D.H.4    Conis, J.M.5
  • 26
    • 27744606099 scopus 로고    scopus 로고
    • Intradialytic blood volume monitoring in ambulatory hemodialysis patients: A randomized trial
    • Reddan DN, Szczech LA, Hasselblad V, et al. Intradialytic blood volume monitoring in ambulatory hemodialysis patients: A randomized trial. J. Am. Soc. Nephrol. 2005; 16 (7): 2162-9.
    • (2005) J. Am. Soc. Nephrol. , vol.16 , Issue.7 , pp. 2162-2169
    • Reddan, D.N.1    Szczech, L.A.2    Hasselblad, V.3
  • 27
    • 18744368078 scopus 로고    scopus 로고
    • Blood volume controlled hemodialysis in hypotension-prone patients: A randomized, multicenter controlled trial
    • Santoro A, Mancini E, Basile C, et al. Blood volume controlled hemodialysis in hypotension-prone patients: A randomized, multicenter controlled trial. Kidney Int. 2002; 62 (3): 1034-45.
    • (2002) Kidney Int. , vol.62 , Issue.3 , pp. 1034-1045
    • Santoro, A.1    Mancini, E.2    Basile, C.3
  • 28
    • 0033864894 scopus 로고    scopus 로고
    • Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency
    • Ronco C, Brendolan A, Milan M, Rodeghiero MP, Zanella M, La Greca G,. Impact of biofeedback-induced cardiovascular stability on hemodialysis tolerance and efficiency. Kidney Int. 2000; 58 (2): 800-8.
    • (2000) Kidney Int. , vol.58 , Issue.2 , pp. 800-808
    • Ronco, C.1    Brendolan, A.2    Milan, M.3    Rodeghiero, M.P.4    Zanella, M.5    La Greca, G.6
  • 29
    • 67649396443 scopus 로고    scopus 로고
    • Improved intradialytic stability during haemodialysis with blood volume-controlled ultrafiltration
    • Gabrielli D, Krystal B, Katzarski K, et al. Improved intradialytic stability during haemodialysis with blood volume-controlled ultrafiltration. J. Nephrol. 2009; 22: 232-40.
    • (2009) J. Nephrol. , vol.22 , pp. 232-240
    • Gabrielli, D.1    Krystal, B.2    Katzarski, K.3
  • 30
    • 0035145183 scopus 로고    scopus 로고
    • Efficacy and safety of haemodialysis treatment with the Hemocontrol biofeedback system: A prospective medium-term study
    • Basile C, Giordano R, Vernaglione L, et al. Efficacy and safety of haemodialysis treatment with the Hemocontrol biofeedback system: A prospective medium-term study. Nephrol. Dial. Transplant. 2001; 16: 328-34.
    • (2001) Nephrol. Dial. Transplant. , vol.16 , pp. 328-334
    • Basile, C.1    Giordano, R.2    Vernaglione, L.3
  • 32
    • 35148879288 scopus 로고    scopus 로고
    • Relative blood volume measurements during hemodialysis: Comparisons between three noninvasive devices
    • Dasselaar JJ, Huisman RM, de Jong PE, Franssen CF,. Relative blood volume measurements during hemodialysis: Comparisons between three noninvasive devices. Hemodial. Int. 2007; 11: 448-55.
    • (2007) Hemodial. Int. , vol.11 , pp. 448-455
    • Dasselaar, J.J.1    Huisman, R.M.2    De Jong, P.E.3    Franssen, C.F.4
  • 33
    • 27144549710 scopus 로고    scopus 로고
    • Measurement of relative blood volume changes during haemodialysis: Merits and limitations
    • Dasselaar JJ, Huisman RM, de Jong PE, Franssen CF,. Measurement of relative blood volume changes during haemodialysis: Merits and limitations. Nephrol. Dial. Transplant. 2005; 20 (10): 2043-9.
    • (2005) Nephrol. Dial. Transplant. , vol.20 , Issue.10 , pp. 2043-2049
    • Dasselaar, J.J.1    Huisman, R.M.2    De Jong, P.E.3    Franssen, C.F.4
  • 34
    • 34548843036 scopus 로고    scopus 로고
    • Relative blood volume changes underestimate total blood volume changes during hemodialysis
    • Dasselaar JJ, Lub-de Hooge MN, Pruim J, et al. Relative blood volume changes underestimate total blood volume changes during hemodialysis. Clin. J. Am. Soc. Nephrol. 2007; 2: 669-74.
    • (2007) Clin. J. Am. Soc. Nephrol. , vol.2 , pp. 669-674
    • Dasselaar, J.J.1    Lub-De Hooge, M.N.2    Pruim, J.3
  • 35
    • 0033919441 scopus 로고    scopus 로고
    • Ultrafiltration profiling and measurement of relative blood volume as strategies to reduce hemodialysis-related side effects
    • Donauer J, Kolblin D, Bek M, Krause A, Bohler J,. Ultrafiltration profiling and measurement of relative blood volume as strategies to reduce hemodialysis-related side effects. Am. J. Kidney Dis. 2000; 36: 115-23.
    • (2000) Am. J. Kidney Dis. , vol.36 , pp. 115-123
    • Donauer, J.1    Kolblin, D.2    Bek, M.3    Krause, A.4    Bohler, J.5
  • 36
    • 34547666650 scopus 로고    scopus 로고
    • Influence of ultrafiltration volume on blood volume changes during hemodialysis as observed in day-of-the-week analysis of hemodialysis sessions
    • Dasselaar JJ, de Jong PE, Huisman RM, Franssen CF,. Influence of ultrafiltration volume on blood volume changes during hemodialysis as observed in day-of-the-week analysis of hemodialysis sessions. ASAIO J. 2007; 53: 479-84.
    • (2007) ASAIO J. , vol.53 , pp. 479-484
    • Dasselaar, J.J.1    De Jong, P.E.2    Huisman, R.M.3    Franssen, C.F.4
  • 37
    • 0021720325 scopus 로고
    • Plasma volume recovery after ultrafiltration in patients with chronic renal failure
    • Koomans HA, Geers AB, Mees EJ,. Plasma volume recovery after ultrafiltration in patients with chronic renal failure. Kidney Int. 1984; 26: 848-54.
    • (1984) Kidney Int. , vol.26 , pp. 848-854
    • Koomans, H.A.1    Geers, A.B.2    Mees, E.J.3
  • 38
    • 0028850258 scopus 로고
    • A new approach to blood pressure and blood volume modulation during hemodialysis: An adaptive fuzzy control module
    • Nordio M, Giove S, Lorenzi S, Marchini P, Saporiti E,. A new approach to blood pressure and blood volume modulation during hemodialysis: An adaptive fuzzy control module. Int. J. Artif. Organs 1995; 18: 513-17.
    • (1995) Int. J. Artif. Organs , vol.18 , pp. 513-517
    • Nordio, M.1    Giove, S.2    Lorenzi, S.3    Marchini, P.4    Saporiti, E.5
  • 39
    • 0035097586 scopus 로고    scopus 로고
    • Prevention of haemodialysis-induced hypotension by biofeedback control of ultrafiltration and infusion
    • Schmidt R, Roeher O, Hickstein H, Korth S,. Prevention of haemodialysis-induced hypotension by biofeedback control of ultrafiltration and infusion. Nephrol. Dial. Transplant. 2001; 16: 595-603.
    • (2001) Nephrol. Dial. Transplant. , vol.16 , pp. 595-603
    • Schmidt, R.1    Roeher, O.2    Hickstein, H.3    Korth, S.4
  • 40
    • 34447512929 scopus 로고    scopus 로고
    • Prevention of dialysis hypotension episodes using fuzzy logic control system
    • Mancini E, Mambelli E, Irpinia M, et al. Prevention of dialysis hypotension episodes using fuzzy logic control system. Nephrol. Dial. Transplant. 2007; 22 (5): 1420-27.
    • (2007) Nephrol. Dial. Transplant. , vol.22 , Issue.5 , pp. 1420-1427
    • Mancini, E.1    Mambelli, E.2    Irpinia, M.3
  • 41
    • 38149054004 scopus 로고    scopus 로고
    • Diagnostic utility of blood volume monitoring in hemodialysis patients
    • Agarwal R, Kelley K, Light RP,. Diagnostic utility of blood volume monitoring in hemodialysis patients. Am. J. Kidney Dis. 2008; 51: 242-54.
    • (2008) Am. J. Kidney Dis. , vol.51 , pp. 242-254
    • Agarwal, R.1    Kelley, K.2    Light, R.P.3
  • 42
    • 74949132021 scopus 로고    scopus 로고
    • Relative plasma volume monitoring during hemodialysis AIDS the assessment of dry weight
    • Sinha AD, Light RP, Agarwal R,. Relative plasma volume monitoring during hemodialysis AIDS the assessment of dry weight. Hypertension 2010; 55: 305-11.
    • (2010) Hypertension , vol.55 , pp. 305-311
    • Sinha, A.D.1    Light, R.P.2    Agarwal, R.3
  • 45
    • 0027293410 scopus 로고
    • Effects of cooler temperature dialysate on hemodynamic stability in 'problem' dialysis patients
    • Jost CM, Agarwal R, Khair-el-Din T, Grayburn PA, Victor RG, Henrich WL,. Effects of cooler temperature dialysate on hemodynamic stability in 'problem' dialysis patients. Kidney Int. 1993; 44 (3): 606-12.
    • (1993) Kidney Int. , vol.44 , Issue.3 , pp. 606-612
    • Jost, C.M.1    Agarwal, R.2    Khair-El-Din, T.3    Grayburn, P.A.4    Victor, R.G.5    Henrich, W.L.6
  • 47
    • 0022000994 scopus 로고
    • Amelioration of hemodialysis-associated hypotension by the use of cool dialysate
    • Sherman RA, Rubin MP, Cody RP, Eisinger RP,. Amelioration of hemodialysis-associated hypotension by the use of cool dialysate. Am. J. Kidney Dis. 1985; 5: 124-7.
    • (1985) Am. J. Kidney Dis. , vol.5 , pp. 124-127
    • Sherman, R.A.1    Rubin, M.P.2    Cody, R.P.3    Eisinger, R.P.4
  • 48
    • 0020971149 scopus 로고
    • Cold as cardiovascular stabilizing factor in hemodialysis: Hemodynamic evaluation
    • Coli U, Landini S, Lucatello S, et al. Cold as cardiovascular stabilizing factor in hemodialysis: Hemodynamic evaluation. Trans. Am. Soc. Artif. Intern. Organs 1983; 29: 71-5.
    • (1983) Trans. Am. Soc. Artif. Intern. Organs , vol.29 , pp. 71-75
    • Coli, U.1    Landini, S.2    Lucatello, S.3
  • 49
    • 0021220009 scopus 로고
    • Effect of variations in dialysate temperature on blood pressure during hemodialysis
    • Sherman RA, Faustino EF, Bernholc AS, Eisinger RP,. Effect of variations in dialysate temperature on blood pressure during hemodialysis. Am. J. Kidney Dis. 1984; 4: 66-8.
    • (1984) Am. J. Kidney Dis. , vol.4 , pp. 66-68
    • Sherman, R.A.1    Faustino, E.F.2    Bernholc, A.S.3    Eisinger, R.P.4
  • 50
    • 0023771274 scopus 로고
    • The effect of cooled dialysate on thermal energy balance in hemodialysis patients
    • Provenzano R, Sawaya B, Frinak S, et al. The effect of cooled dialysate on thermal energy balance in hemodialysis patients. ASAIO Trans. 1988; 34: 515-18.
    • (1988) ASAIO Trans. , vol.34 , pp. 515-518
    • Provenzano, R.1    Sawaya, B.2    Frinak, S.3
  • 51
    • 0025061360 scopus 로고
    • Epidemiology of symptomatic hypotension in hemodialysis: Is cool dialysate beneficial for all patients?
    • Orofino L, Marcen R, Quereda C, et al. Epidemiology of symptomatic hypotension in hemodialysis: Is cool dialysate beneficial for all patients? Am. J. Nephrol. 1990; 10 (3): 177-80.
    • (1990) Am. J. Nephrol. , vol.10 , Issue.3 , pp. 177-180
    • Orofino, L.1    Marcen, R.2    Quereda, C.3
  • 52
    • 33845245046 scopus 로고    scopus 로고
    • Is cool dialysis an effective and well-tolerated means of reducing the frequency of intradialytic hypotension?
    • Levin NW, Kotanko P,. Is cool dialysis an effective and well-tolerated means of reducing the frequency of intradialytic hypotension? Nat. Clin. Pract. Nephrol. 2006; 2: 670-71.
    • (2006) Nat. Clin. Pract. Nephrol. , vol.2 , pp. 670-671
    • Levin, N.W.1    Kotanko, P.2
  • 53
    • 0036326468 scopus 로고    scopus 로고
    • The effects of control of thermal balance on vascular stability in hemodialysis patients: Results of the European randomized clinical trial
    • Maggiore Q, Pizzarelli F, Santoro A, et al. The effects of control of thermal balance on vascular stability in hemodialysis patients: Results of the European randomized clinical trial. Am. J. Kidney Dis. 2002; 40: 280-90.
    • (2002) Am. J. Kidney Dis. , vol.40 , pp. 280-290
    • Maggiore, Q.1    Pizzarelli, F.2    Santoro, A.3
  • 54
    • 0035092651 scopus 로고    scopus 로고
    • Preventing dialysis hypotension: A comparison of usual protective maneuvers
    • DOI 10.1046/j.1523-1755.2001.0590031175.x
    • Dheenan S, Henrich WL,. Preventing dialysis hypotension: A comparison of usual protective maneuvers. Kidney Int. 2001; 59 (3): 1175-81. (Pubitemid 32206883)
    • (2001) Kidney International , vol.59 , Issue.3 , pp. 1175-1181
    • Dheenan, S.1    Henrich, W.L.2
  • 55
    • 0029798687 scopus 로고    scopus 로고
    • The protective effect of cool dialysate is dependent on patients' predialysis temperature
    • Fine A, Penner B,. The protective effect of cool dialysate is dependent on patients' predialysis temperature. Am. J. Kidney Dis. 1996; 28: 262-5.
    • (1996) Am. J. Kidney Dis. , vol.28 , pp. 262-265
    • Fine, A.1    Penner, B.2
  • 56
    • 0347917074 scopus 로고    scopus 로고
    • Effect of cool temperature dialysate on the quality and patients' perception of haemodialysis
    • Ayoub A, Finlayson M,. Effect of cool temperature dialysate on the quality and patients' perception of haemodialysis. Nephrol. Dial. Transplant. 2004; 19: 190-94.
    • (2004) Nephrol. Dial. Transplant. , vol.19 , pp. 190-194
    • Ayoub, A.1    Finlayson, M.2
  • 57
    • 0033051832 scopus 로고    scopus 로고
    • Effect of dialysate temperature on energy balance during hemodialysis: Quantification of extracorporeal energy transfer
    • van der Sande FM, Kooman JP, Burema JH, et al. Effect of dialysate temperature on energy balance during hemodialysis: Quantification of extracorporeal energy transfer. Am. J. Kidney Dis. 1999; 33: 1115-21.
    • (1999) Am. J. Kidney Dis. , vol.33 , pp. 1115-1121
    • Van Der Sande, F.M.1    Kooman, J.P.2    Burema, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.