메뉴 건너뛰기




Volumn 18, Issue 26, 2010, Pages 27167-27172

Femtotesla atomic magnetometry in a microfabricated vapor cell

Author keywords

[No Author keywords available]

Indexed keywords

MAGNETOMETERS; MICROFABRICATION; PUMPS; RUBIDIUM; SEMICONDUCTING SILICON COMPOUNDS; SILICON WAFERS; VAPORS;

EID: 78650546413     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.18.027167     Document Type: Article
Times cited : (162)

References (20)
  • 1
    • 34047164912 scopus 로고    scopus 로고
    • Optical magnetometry
    • D. Budker, and M. Romalis, "Optical magnetometry," Nat. Phys. 3(4), 227-234 (2007).
    • (2007) Nat. Phys. , vol.3 , Issue.4 , pp. 227-234
    • Budker, D.1    Romalis, M.2
  • 2
    • 0037431353 scopus 로고    scopus 로고
    • A subfemtotesla multichannel atomic magnetometer
    • I. K. Kominis, T. W. Kornack, J. C. Allred, and M. V. Romalis, "A subfemtotesla multichannel atomic magnetometer," Nature 422(6932), 596-599 (2003).
    • (2003) Nature , vol.422 , Issue.6932 , pp. 596-599
    • Kominis, I.K.1    Kornack, T.W.2    Allred, J.C.3    Romalis, M.V.4
  • 3
    • 77958086932 scopus 로고    scopus 로고
    • Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
    • H. B. Dang, A. C. Maloof, and M. V. Romalis, "Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer," Appl. Phys. Lett. 97(15), 151110 (2010).
    • (2010) Appl. Phys. Lett. , vol.97 , Issue.15 , pp. 151110
    • Dang, H.B.1    Maloof, A.C.2    Romalis, M.V.3
  • 5
    • 4243501174 scopus 로고
    • Spin-exchange shift and narrowing of magnetic resonance lines in optically pumped alkali vapors
    • W. Happer, and H. Tang, "Spin-exchange shift and narrowing of magnetic resonance lines in optically pumped alkali vapors," Phys. Rev. Lett. 31(5), 273-276 (1973).
    • (1973) Phys. Rev. Lett. , vol.31 , Issue.5 , pp. 273-276
    • Happer, W.1    Tang, H.2
  • 6
    • 18744406353 scopus 로고    scopus 로고
    • High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation
    • J. C. Allred, R. N. Lyman, T. W. Kornack, and M. V. Romalis, "High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation," Phys. Rev. Lett. 89(13), 130801 (2002).
    • (2002) Phys. Rev. Lett. , vol.89 , Issue.13 , pp. 130801
    • Allred, J.C.1    Lyman, R.N.2    Kornack, T.W.3    Romalis, M.V.4
  • 9
    • 32944460177 scopus 로고    scopus 로고
    • Biomagnetism using SQUIDs: Status and perspectives
    • DOI 10.1088/0953-2048/19/3/024, PII S0953204806106983
    • K. Sternickel, and A. I. Braginski, "Biomagnetism using SQUIDs: status and perspectives," Supercond. Sci. Technol. 19(3), S160-S171 (2006). (Pubitemid 43260892)
    • (2006) Superconductor Science and Technology , vol.19 , Issue.3
    • Sternickel, K.1    Braginski, A.I.2
  • 10
    • 77957662548 scopus 로고    scopus 로고
    • Cross-validation of microfabricated atomic magnetometers with superconducting quantum interference devices for biomagnetic applications
    • S. Knappe, T. H. Sander, O. Kosch, F. Wiekhorst, J. Kitching, and L. Trahms, "Cross-validation of microfabricated atomic magnetometers with superconducting quantum interference devices for biomagnetic applications," Appl. Phys. Lett. 97(13), 133703 (2010).
    • (2010) Appl. Phys. Lett. , vol.97 , Issue.13 , pp. 133703
    • Knappe, S.1    Sander, T.H.2    Kosch, O.3    Wiekhorst, F.4    Kitching, J.5    Trahms, L.6
  • 11
    • 35748978182 scopus 로고    scopus 로고
    • Subpicotesla atomic magnetometry with a microfabricated vapour cell
    • V. Shah, S. Knappe, P. D. D. Schwindt, and J. Kitching, "Subpicotesla atomic magnetometry with a microfabricated vapour cell," Nat. Photonics 1(11), 649-652 (2007).
    • (2007) Nat. Photonics , vol.1 , Issue.11 , pp. 649-652
    • Shah, V.1    Knappe, S.2    Schwindt, P.D.D.3    Kitching, J.4
  • 12
    • 3543104772 scopus 로고
    • Detection of very weak magnetic fields (10-9 gauss) by 87Rb zero-field level crossing resonances
    • J. Dupont-Roc, S. Haroche, and C. Cohen-Tannoudji, "Detection of very weak magnetic fields (10-9 gauss) by 87Rb zero-field level crossing resonances," Phys. Lett. A 28(9), 638-639 (1969).
    • (1969) Phys. Lett. A , vol.28 , Issue.9 , pp. 638-639
    • Dupont-Roc, J.1    Haroche, S.2    Cohen-Tannoudji, C.3
  • 14
    • 43049090882 scopus 로고    scopus 로고
    • Calculation of magnetic field noise from high-permeability magnetic shields and conducting objects with simple geometry
    • S. K. Lee, and M. V. Romalis, "Calculation of magnetic field noise from high-permeability magnetic shields and conducting objects with simple geometry," J. Appl. Phys. 103(8), 084904 (2008).
    • (2008) J. Appl. Phys. , vol.103 , Issue.8 , pp. 084904
    • Lee, S.K.1    Romalis, M.V.2
  • 15
    • 33747801444 scopus 로고    scopus 로고
    • Highly sensitive magnetometers: A review
    • D. Robbes, "Highly sensitive magnetometers: a review," Sens. Actuators A Phys. 129(1-2), 86-93 (2006).
    • (2006) Sens. Actuators A Phys. , vol.129 , Issue.1-2 , pp. 86-93
    • Robbes, D.1
  • 16
    • 0014563672 scopus 로고
    • Field assisted glass-metal sealing
    • G. Wallis, and D. I. Pomerantz, "Field assisted glass-metal sealing," J. Appl. Phys. 40(10), 3946-3949 (1969).
    • (1969) J. Appl. Phys. , vol.40 , Issue.10 , pp. 3946-3949
    • Wallis, G.1    Pomerantz, D.I.2
  • 17
    • 26844521535 scopus 로고    scopus 로고
    • Atomic vapor cells for chip-scale atomic clocks with improved long-term frequency stability
    • DOI 10.1364/OL.30.002351
    • S. Knappe, V. Gerginov, P. D. D. Schwindt, V. Shah, H. G. Robinson, L. Hollberg, and J. Kitching, "Atomic vapor cells for chip-scale atomic clocks with improved long-term frequency stability," Opt. Lett. 30(18), 2351-2353 (2005). (Pubitemid 41463485)
    • (2005) Optics Letters , vol.30 , Issue.18 , pp. 2351-2353
    • Knappe, S.1    Gerginov, V.2    Schwindt, P.D.D.3    Shah, V.4    Robinson, H.G.5    Hollberg, L.6    Kitching, J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.