메뉴 건너뛰기




Volumn 129, Issue 1-2 SPEC. ISS., 2006, Pages 86-93

Highly sensitive magnetometers-a review

Author keywords

Atomic vapor magnetometer; GMR; Magnetic field sensors; Magnetic tunnel junction; Spin valve; SQUID

Indexed keywords

MAGNETIC DEVICES; MAGNETOSTRICTION; SIGNAL PROCESSING; SQUIDS; SUPERCONDUCTING MAGNETS; TUNNEL JUNCTIONS;

EID: 33747801444     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2005.11.023     Document Type: Article
Times cited : (155)

References (31)
  • 1
    • 0035268223 scopus 로고    scopus 로고
    • Highly sensitive uncooled magnetometers: state of the art superconducting magnetic hybrid magnetometers, an alternative to SQUIDs? PT ASC 2000
    • Virginia Beach, September 2000
    • Robbes D., Article Invité C., Dolabdjian S., Saez Y., Monfort G., Kaiser P., and Ciereanu. Highly sensitive uncooled magnetometers: state of the art superconducting magnetic hybrid magnetometers, an alternative to SQUIDs? PT ASC 2000. Virginia Beach, September 2000. IEEE Trans. Appl. Supercond. 11 1 (2001) 629-634
    • (2001) IEEE Trans. Appl. Supercond. , vol.11 , Issue.1 , pp. 629-634
    • Robbes, D.1    Article Invité, C.2    Dolabdjian, S.3    Saez, Y.4    Monfort, G.5    Kaiser, P.6    Ciereanu7
  • 2
    • 30244454714 scopus 로고
    • c superconductivity in the Ba-La-Cu-O system
    • c superconductivity in the Ba-La-Cu-O system. Z. Phys. B 64 (1986) 189-193
    • (1986) Z. Phys. B , vol.64 , pp. 189-193
    • Bednorz, G.1    Müller, K.A.2
  • 3
    • 0001129010 scopus 로고    scopus 로고
    • Substrate selection for high temperature superconducting thin films
    • Phillips J.M. Substrate selection for high temperature superconducting thin films. J. Appl. Phys. 9 4 (1996) 1829-1848
    • (1996) J. Appl. Phys. , vol.9 , Issue.4 , pp. 1829-1848
    • Phillips, J.M.1
  • 5
    • 0035268696 scopus 로고    scopus 로고
    • SQUID magnetocardiography: status and perspectives
    • Koch H. SQUID magnetocardiography: status and perspectives. IEEE Trans. Appl. Supercond. 11 1 (2001) 49-59
    • (2001) IEEE Trans. Appl. Supercond. , vol.11 , Issue.1 , pp. 49-59
    • Koch, H.1
  • 8
    • 0346413333 scopus 로고    scopus 로고
    • c dc SQUID electronics
    • Online at stacks.iop.org/SUST/16/1320
    • c dc SQUID electronics. Supercond. Sci. Technol. 16 (2003) 1320-1336 Online at stacks.iop.org/SUST/16/1320
    • (2003) Supercond. Sci. Technol. , vol.16 , pp. 1320-1336
    • Drung, D.1
  • 9
    • 0036498420 scopus 로고    scopus 로고
    • High-performance DC SQUID read-out electronics
    • Drung D. High-performance DC SQUID read-out electronics. Physica C 368 (2002) 134-140
    • (2002) Physica C , vol.368 , pp. 134-140
    • Drung, D.1
  • 11
    • 33747755544 scopus 로고    scopus 로고
    • http://www.gemsys.ca/current/index.html
  • 12
    • 33747759133 scopus 로고    scopus 로고
    • G. Bison, R. Wynands, A. Weis, Optimization and performance of an optical cardio-magnetometer, arXiv:physics/0406157 v1 30 Jun 2004.
  • 13
    • 0037620425 scopus 로고    scopus 로고
    • A laser-pumped magnetometer for the mapping of human cardio-magnetic fields
    • Bison G., Wynands R., and Weis A. A laser-pumped magnetometer for the mapping of human cardio-magnetic fields. Appl. Phys. B 76 (2003) 325-328
    • (2003) Appl. Phys. B , vol.76 , pp. 325-328
    • Bison, G.1    Wynands, R.2    Weis, A.3
  • 14
    • 0042142796 scopus 로고    scopus 로고
    • Dynamical mapping of the human cardiomagnetic field using a room temperature, laser-optical sensor
    • Bison G., Wynands R., and Weis A. Dynamical mapping of the human cardiomagnetic field using a room temperature, laser-optical sensor. Opt. Express 11 8 (2003) 904-909
    • (2003) Opt. Express , vol.11 , Issue.8 , pp. 904-909
    • Bison, G.1    Wynands, R.2    Weis, A.3
  • 15
    • 0000455150 scopus 로고    scopus 로고
    • Signal to noise improvement of biomagnetic signals using a flux gate probe and a real time signal processing
    • Dolabdjian C., Saez S., Reyes Toledo A., and Robbes D. Signal to noise improvement of biomagnetic signals using a flux gate probe and a real time signal processing. Rev. Sci. Instrum. 69 10 (1998) 3678-3680
    • (1998) Rev. Sci. Instrum. , vol.69 , Issue.10 , pp. 3678-3680
    • Dolabdjian, C.1    Saez, S.2    Reyes Toledo, A.3    Robbes, D.4
  • 19
    • 33747754862 scopus 로고    scopus 로고
    • J.P. Wikswo, SQUIDs remain best tool for measuring Brains's magnetic field, Phys. Today February (2003).
  • 20
    • 2942648084 scopus 로고    scopus 로고
    • M. Pannetier, C. Fermon, G. Le Goff, J. Simola, E. Kerr, Femtotesla magnetic field measurement with magnetoresistive sensors, Science June (2004).
  • 21
    • 33747758432 scopus 로고    scopus 로고
    • M. Pannetier, C. Fermon, G. Legoff, E. Kerr, Ultra-sensitive mixed sensors-design and performance, paper M-P.30, this conference.
  • 23
    • 33947547745 scopus 로고    scopus 로고
    • Investigation of fatigue cracks under rivet head airframe using improved GMR magnetometer in an eddy current system
    • Perez L., Le Hir J., Dolabdjian C., and Butin L. Investigation of fatigue cracks under rivet head airframe using improved GMR magnetometer in an eddy current system. J. Electrical Eng. 55 10/S (2004) 10-11
    • (2004) J. Electrical Eng. , vol.55 , Issue.10 S , pp. 10-11
    • Perez, L.1    Le Hir, J.2    Dolabdjian, C.3    Butin, L.4
  • 25
    • 33747810871 scopus 로고    scopus 로고
    • D. Ménard, G. Rudkowska, L. Clime, P. Ciureanu, A. Yelon, S. Saez, C. Dolabdjian, D. Robbes, Progress towards the optimization of the signal-to-noise ratio in giant magnetoimpedance sensors, this conference.
  • 26
    • 33747778128 scopus 로고    scopus 로고
    • A. Boukhenoufa, C. Dolabdjian, D. Robbes, High sensitivity giant magneto-inductive magnetometer characterization implemented with a low frequency magnetic noise reduction technic, Rev. Scientific Instrum., in press.
  • 28
    • 0041377030 scopus 로고    scopus 로고
    • Epitaxial yttrium iron garnet film as an active medium of an even-harmonic magnetic field transducer
    • Vetoshko P.M., Valeiko M.V., and Nikitin P.I. Epitaxial yttrium iron garnet film as an active medium of an even-harmonic magnetic field transducer. Sens. Actuators A 106 (2003) 270-273
    • (2003) Sens. Actuators A , vol.106 , pp. 270-273
    • Vetoshko, P.M.1    Valeiko, M.V.2    Nikitin, P.I.3
  • 31
    • 2542464138 scopus 로고    scopus 로고
    • Low noise magnetic flux sensors based on the extraordinary magnetoresistance effect
    • Müller C.H., Kronenwerth O., Heyn Ch., and Grundler D. Low noise magnetic flux sensors based on the extraordinary magnetoresistance effect. Appl. Phys. Lett. 84 17 (2004) 3343-3345
    • (2004) Appl. Phys. Lett. , vol.84 , Issue.17 , pp. 3343-3345
    • Müller, C.H.1    Kronenwerth, O.2    Heyn, Ch.3    Grundler, D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.