Volumn 55, Issue 12, 2010, Pages 1671-1679

In-vitro comparison of 4 large-volume nebulizers in 8 hours of continuous nebulization

Author keywords

Aerosol; Albuterol; Nebulization; Nebulizer; Particle size

Indexed keywords

SALBUTAMOL SULFATE;

EID: 78650325850     PISSN: 00201324     EISSN: 19433654     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (8)

References (31)
  • 1
    • 79959344460 scopus 로고    scopus 로고
    • National Asthma Education and Prevention Program. Expert Panel Report 3 (EPR-3): Guidelines for the diagnosis and management of asthma summary report
    • National Asthma Education and Prevention Program. Expert Panel Report 3 (EPR-3): Guidelines for the diagnosis and management of asthma summary report 2007. J Allergy Clin Immunol 2007;120 (5 Suppl):S94-S138.
    • (2007) J Allergy Clin Immunol , vol.120 , Issue.5 SUPPL.
  • 3
    • 28844493712 scopus 로고    scopus 로고
    • Current management of status asthmaticus in the pediatric ICU
    • Marcoux KK. Current management of status asthmaticus in the pediatric ICU. Crit Care Nurs Clin North Am 2005;17(4):463-479.
    • (2005) Crit Care Nurs Clin North Am , vol.17 , Issue.4 , pp. 463-479
    • Marcoux, K.K.1
  • 4
    • 0029958815 scopus 로고    scopus 로고
    • Efficacy and safety of continuous albuterol nebulization in children with severe status asthmaticus
    • Craig VL, Bigos D, Brilli RJ. Efficacy and safety of continuous albuterol nebulization in children with severe status asthmaticus. Pediatr Emerg Care 1996;12(1):1-5.
    • (1996) Pediatr Emerg Care , vol.12 , Issue.1 , pp. 1-5
    • Craig, V.L.1    Bigos, D.2    Brilli, R.J.3
  • 5
    • 0029082727 scopus 로고
    • Continuous versus frequent intermittent nebulization of albuterol in acute asthma: A randomized, prospective study
    • Reisner C, Kotch A, Dworkin G. Continuous versus frequent intermittent nebulization of albuterol in acute asthma: a randomized, prospective study. Ann Allergy Asthma Immunol 1995;75(1):41-47.
    • (1995) Ann Allergy Asthma Immunol , vol.75 , Issue.1 , pp. 41-47
    • Reisner, C.1    Kotch, A.2    Dworkin, G.3
  • 6
    • 0027445729 scopus 로고
    • A prospective, randomized study of continuous versus intermittent nebulized albuterol for severe status asthmaticus in children
    • Papo MC, Frank J, Thompson AE. A prospective, randomized study of continuous versus intermittent nebulized albuterol for severe status asthmaticus in children. Crit Care Med 1993;21(10):1479-1486.
    • (1993) Crit Care Med , vol.21 , Issue.10 , pp. 1479-1486
    • Papo, M.C.1    Frank, J.2    Thompson, A.E.3
  • 7
    • 35148816877 scopus 로고    scopus 로고
    • The increased cost of complications in children with status asthmaticus
    • Carroll CL and Zucker AR. The increased cost of complications in children with status asthmaticus. Pediatr Pulmonol 2007;(42):914-919.
    • (2007) Pediatr Pulmonol , Issue.42 , pp. 914-919
    • Carroll, C.L.1    Zucker, A.R.2
  • 8
    • 0025238546 scopus 로고
    • Description of a delivery method for continuously aerosolized albuterol in status asthmaticus
    • Voss KR, Willsie-Ediger SK, Pyszczynski DR, Nelson KA. Description of a delivery method for continuously aerosolized albuterol in status asthmaticus. J Asthma 1990;27:37-39.
    • (1990) J Asthma , vol.27 , pp. 37-39
    • Voss, K.R.1    Willsie-Ediger, S.K.2    Pyszczynski, D.R.3    Nelson, K.A.4
  • 10
    • 0031685355 scopus 로고    scopus 로고
    • Four hours of continuous albuterol nebulization
    • Berlinski A, Waldrep JC. Four hours of continuous albuterol nebulization. Chest 1998;114(3):847-853.
    • (1998) Chest , vol.114 , Issue.3 , pp. 847-853
    • Berlinski, A.1    Waldrep, J.C.2
  • 11
    • 0030968138 scopus 로고    scopus 로고
    • Aerosol delivery during continuous nebulization
    • McPeck M, Tandon R, Hughes K, Smaldone GC. Aerosol delivery during continuous nebulization. Chest 1997;111(5):1200-1205.
    • (1997) Chest , vol.111 , Issue.5 , pp. 1200-1205
    • McPeck, M.1    Tandon, R.2    Hughes, K.3    Smaldone, G.C.4
  • 13
    • 0029763316 scopus 로고    scopus 로고
    • Medication nebulizer performance. Effects of diluent volume, nebulizer flow, and nebulizer brand
    • Hess D, Fisher D, Williams P, Pooler S, Kacmarek RM. Medication nebulizer performance. Effects of diluent volume, nebulizer flow, and nebulizer brand. Chest 1996;110(2):498-505.
    • (1996) Chest , vol.110 , Issue.2 , pp. 498-505
    • Hess, D.1    Fisher, D.2    Williams, P.3    Pooler, S.4    Kacmarek, R.M.5
  • 14
    • 12244300136 scopus 로고    scopus 로고
    • Next generation pharmaceutical impactor: A new impactor for pharmaceutical inhaler testing. Part III: Extension of archival calibration to 15 L/min
    • Marple VA, Olson BA, Santhanakrishnan K, Roberts DL, Mitchell JP, Hudson-Curtis BL. Next generation pharmaceutical impactor: a new impactor for pharmaceutical inhaler testing. Part III: Extension of archival calibration to 15 L/min. J Aerosol Med 2004;17(4):335-343.
    • (2004) J Aerosol Med , vol.17 , Issue.4 , pp. 335-343
    • Marple, V.A.1    Olson, B.A.2    Santhanakrishnan, K.3    Roberts, D.L.4    Mitchell, J.P.5    Hudson-Curtis, B.L.6
  • 15
    • 34249890213 scopus 로고    scopus 로고
    • Determination of nebulizer droplet size distribution: A method based on impactor refrigeration
    • Berg E, Svensson JO, Asking L. Determination of nebulizer droplet size distribution: a method based on impactor refrigeration. J Aerosol Med 2007;20(2):97-104.
    • (2007) J Aerosol Med , vol.20 , Issue.2 , pp. 97-104
    • Berg, E.1    Svensson, J.O.2    Asking, L.3
  • 17
    • 25144469085 scopus 로고    scopus 로고
    • United States pharmacopeia. Physical tests and determinations. In, Rockville, MD: United States Pharmacopeia
    • United States pharmacopeia. Physical tests and determinations. In: United States pharmacopeia-national formulary (USP-NF 28). Rockville, MD: United States Pharmacopeia; 2004:2359-2377.
    • (2004) United States Pharmacopeia-national Formulary (USP-NF 28) , pp. 2359-2377
  • 18
    • 71949085191 scopus 로고    scopus 로고
    • Preparations for nebulization: characterization
    • Preparations for nebulization: characterization. PharmEuropa 2006; 18(2):280-283.
    • (2006) PharmEuropa , vol.18 , Issue.2 , pp. 280-283
  • 19
    • 0030917746 scopus 로고    scopus 로고
    • Measuring nebulizer output: Aerosol production vs gravimetric analysis
    • Tandon R, McPeck M, Smaldone GC. Measuring nebulizer output: aerosol production vs gravimetric analysis. Chest 1997;111(5):1361-1365.
    • (1997) Chest , vol.111 , Issue.5 , pp. 1361-1365
    • Tandon, R.1    McPeck, M.2    Smaldone, G.C.3
  • 20
    • 0030916624 scopus 로고    scopus 로고
    • The science of nebulised drug delivery
    • O'Callaghan C, Barry PW. The science of nebulised drug delivery. Thorax 1997;52(Suppl 2):S31-S44.
    • (1997) Thorax , vol.52 , Issue.SUPPL. 2
    • O'Callaghan, C.1    Barry, P.W.2
  • 21
    • 0036835673 scopus 로고    scopus 로고
    • Bringing new nebulizer technologies to market: Regulatory issues
    • Meyer RJ. Bringing new nebulizer technologies to market: regulatory issues. Respir Care 2002;47(11):1334-1336.
    • (2002) Respir Care , vol.47 , Issue.11 , pp. 1334-1336
    • Meyer, R.J.1
  • 22
    • 30444452988 scopus 로고    scopus 로고
    • Regional lung deposition and bronchodilator response as a function of ß2-agonist particle size
    • Usmani OS, Biddiscombe MF, Barnes PJ. Regional lung deposition and bronchodilator response as a function of ß2-agonist particle size. Am J Respir Crit Care Med 2005;172(12):1497-504.
    • (2005) Am J Respir Crit Care Med , vol.172 , Issue.12 , pp. 1497-1504
    • Usmani, O.S.1    Biddiscombe, M.F.2    Barnes, P.J.3
  • 24
    • 0029844148 scopus 로고    scopus 로고
    • Optimal particle size for β2- agonists and anticholinergic aerosols in patients with severe airflow obstruction
    • Zanen P, Go LT, Lammers JWJ. Optimal particle size for β2- agonists and anticholinergic aerosols in patients with severe airflow obstruction. Thorax 1996;51(10):977-980.
    • (1996) Thorax , vol.51 , Issue.10 , pp. 977-980
    • Zanen, P.1    Go, L.T.2    Lammers, J.W.J.3
  • 26
    • 52349102779 scopus 로고    scopus 로고
    • Hypertonic saline cough provocation test with salbutamol pretreatment: Evidence for sensorineural dysfunction in asthma
    • Koskela HO, Purokivi MK, Kontra KM, Taivainen AH, Tukiainen HO. Hypertonic saline cough provocation test with salbutamol pretreatment: evidence for sensorineural dysfunction in asthma. Clin Exp Allergy 2008;38(7):1100-1107.
    • (2008) Clin Exp Allergy , vol.38 , Issue.7 , pp. 1100-1107
    • Koskela, H.O.1    Purokivi, M.K.2    Kontra, K.M.3    Taivainen, A.H.4    Tukiainen, H.O.5
  • 27
    • 1242329184 scopus 로고    scopus 로고
    • Nebulized salbutamol administered during sputum induction improves bronchoprotection in patients with asthma
    • Delvaux M, Henket M, Lau L, Kange P, Bartsch P, Djukanovic R, Louis R. Nebulized salbutamol administered during sputum induction improves bronchoprotection in patients with asthma. Thorax 2004;59(2):111-115.
    • (2004) Thorax , vol.59 , Issue.2 , pp. 111-115
    • Delvaux, M.1    Henket, M.2    Lau, L.3    Kange, P.4    Bartsch, P.5    Djukanovic, R.6    Louis, R.7
  • 28
    • 0030047681 scopus 로고    scopus 로고
    • Comparison of volume output from two different continuous nebulizer systems
    • Reisner C, Lee J, Kotch A, Dworkin G. Comparison of volume output from two different continuous nebulizer systems. Ann Allergy Asthma Immunol 1996;76(2):209-213.
    • (1996) Ann Allergy Asthma Immunol , vol.76 , Issue.2 , pp. 209-213
    • Reisner, C.1    Lee, J.2    Kotch, A.3    Dworkin, G.4
  • 29
    • 0025988429 scopus 로고
    • Extreme variability in aerosol output of the DeVilbiss 646 jet nebulizer
    • Hollie MC, Malone RA, Skufca RM, and Nelson HS. Extreme variability in aerosol output of the DeVilbiss 646 jet nebulizer. Chest 1991;100(5):1339-1344.
    • (1991) Chest , vol.100 , Issue.5 , pp. 1339-1344
    • Hollie, M.C.1    Malone, R.A.2    Skufca, R.M.3    Nelson, H.S.4
  • 30
    • 0026513078 scopus 로고
    • Disposable jet nebulizers. How reliable are they
    • Alvine GF, Rodgers P, Fitzsimmons KM, and Ahrens RC. Disposable jet nebulizers. How reliable are they? Chest 1992;101(2):316-319.
    • (1992) Chest , vol.101 , Issue.2 , pp. 316-319
    • Alvine, G.F.1    Rodgers, P.2    Fitzsimmons, K.M.3    Ahrens, R.C.4
  • 31
    • 0025290635 scopus 로고
    • Droplets produced by medical nebulizers. Some factors affecting their size and solute concentration
    • Phipps PR, and Gonda I. Droplets produced by medical nebulizers. Some factors affecting their size and solute concentration. Chest 1990;97(6):1327-1332.
    • (1990) Chest , vol.97 , Issue.6 , pp. 1327-1332
    • Phipps, P.R.1    Gonda, I.2