메뉴 건너뛰기




Volumn 111, Issue 5, 1997, Pages 1361-1365

Measuring nebulizer output: Aerosol production vs gravimetric analysis

Author keywords

aerosol; bronchodilators; jet nebulizers; radiolabel

Indexed keywords

DRUG;

EID: 0030917746     PISSN: 00123692     EISSN: None     Source Type: Journal    
DOI: 10.1378/chest.111.5.1361     Document Type: Article
Times cited : (44)

References (15)
  • 1
    • 0023276763 scopus 로고
    • Evaluation of nebulizers for bronchial challenge tests
    • Tsanakas JN, Wilson AJ, Boon AW. Evaluation of nebulizers for bronchial challenge tests. Arch Dis Child 1987; 62:506-08
    • (1987) Arch Dis Child , vol.62 , pp. 506-508
    • Tsanakas, J.N.1    Wilson, A.J.2    Boon, A.W.3
  • 2
    • 0026513078 scopus 로고
    • Disposable jet nebulizers: How reliable are they?
    • Alvine GF, Rodgers P, Fitzsimmons KM, et al. Disposable jet nebulizers: How reliable are they? Chest 1992; 101:316-19
    • (1992) Chest , vol.101 , pp. 316-319
    • Alvine, G.F.1    Rodgers, P.2    Fitzsimmons, K.M.3
  • 3
    • 0024316115 scopus 로고
    • Medication delivery performance of eight small volume hand held nebulizers: Effects of diluent volume, gas flow rate and nebulizer model
    • Hess D, Horney D, Snyder T. Medication delivery performance of eight small volume hand held nebulizers: effects of diluent volume, gas flow rate and nebulizer model. Respir Care 1989; 34:717-23
    • (1989) Respir Care , vol.34 , pp. 717-723
    • Hess, D.1    Horney, D.2    Snyder, T.3
  • 4
    • 0028113025 scopus 로고
    • A comparison of commercial jet nebulizers
    • Loffert DT, Ikle DS, Nelson HS. A comparison of commercial jet nebulizers. Chest 1994; 106:1788-93
    • (1994) Chest , vol.106 , pp. 1788-1793
    • Loffert, D.T.1    Ikle, D.S.2    Nelson, H.S.3
  • 5
    • 0021125095 scopus 로고
    • Different performance of two commercial nebulizers
    • Arossa W, Quagliotti F, Sala N, et al. Different performance of two commercial nebulizers. Respiration 1984; 46:128-32
    • (1984) Respiration , vol.46 , pp. 128-132
    • Arossa, W.1    Quagliotti, F.2    Sala, N.3
  • 6
    • 0021858480 scopus 로고
    • Efficiency of air compressor driven nebulizers
    • Kradjan WA, Lakshminarayan S. Efficiency of air compressor driven nebulizers. Chest 1985; 87:512-16
    • (1985) Chest , vol.87 , pp. 512-516
    • Kradjan, W.A.1    Lakshminarayan, S.2
  • 7
    • 0025988429 scopus 로고
    • Extreme variability in aerosol output of the Devilbiss 646 jet nebulizer
    • Hollie MC, Malone RA, Skufca RM, et al. Extreme variability in aerosol output of the Devilbiss 646 jet nebulizer [abstract]. Chest 1991; 100:1339
    • (1991) Chest , vol.100 , pp. 1339
    • Hollie, M.C.1    Malone, R.A.2    Skufca, R.M.3
  • 8
    • 0028610345 scopus 로고
    • A nebulizer system for highly reproducible aerosol delivery
    • Knoch M, Wunderlich E, Geldner S. A nebulizer system for highly reproducible aerosol delivery. J Aerosol Med 1994; 7:229-37
    • (1994) J Aerosol Med , vol.7 , pp. 229-237
    • Knoch, M.1    Wunderlich, E.2    Geldner, S.3
  • 9
    • 0025234591 scopus 로고
    • How much aerosol reaches the lungs of wheezy infants and toddlers
    • Salmon B, Wilson NM, Silverman M. How much aerosol reaches the lungs of wheezy infants and toddlers. Arch Dis Child 1990; 65:401-03
    • (1990) Arch Dis Child , vol.65 , pp. 401-403
    • Salmon, B.1    Wilson, N.M.2    Silverman, M.3
  • 10
    • 0025000565 scopus 로고
    • Jet and ultrasonic nebulizer output: Use of a new method for direct measurement of aerosol output
    • Dennis JH, Stenton SC, Beach JR, et al. Jet and ultrasonic nebulizer output: use of a new method for direct measurement of aerosol output. Thorax 1990; 45:728-32
    • (1990) Thorax , vol.45 , pp. 728-732
    • Dennis, J.H.1    Stenton, S.C.2    Beach, J.R.3
  • 11
    • 0024477067 scopus 로고
    • Inaccurate calculation of drug output from nebulizers
    • O'Callaghan C, Clarke AR, Milner AD. Inaccurate calculation of drug output from nebulizers. Eur J Pediatr 1989; 148: 473-74
    • (1989) Eur J Pediatr , vol.148 , pp. 473-474
    • O'Callaghan, C.1    Clarke, A.R.2    Milner, A.D.3
  • 12
    • 0024459838 scopus 로고
    • Importance of evaporative losses during standardized nebulized inhalation provocation tests
    • Cockroft DW, Hurst TS, Gore BP. Importance of evaporative losses during standardized nebulized inhalation provocation tests. Chest 1989; 96:505-08
    • (1989) Chest , vol.96 , pp. 505-508
    • Cockroft, D.W.1    Hurst, T.S.2    Gore, B.P.3
  • 13
    • 85012535540 scopus 로고
    • Drug delivery by nebulization: 'reality testing'
    • Smaldone GC. Drug delivery by nebulization: 'reality testing' [editorial]. J Aerosol Med 1994; 7:213-16
    • (1994) J Aerosol Med , vol.7 , pp. 213-216
    • Smaldone, G.C.1
  • 14
    • 0030968138 scopus 로고    scopus 로고
    • Aerosol delivery during continuous nebulization
    • in press
    • McPeck M, Tandon R, Hughes K, et al. Aerosol delivery during continuous nebulization. Chest 1997 (in press)
    • (1997) Chest
    • McPeck, M.1    Tandon, R.2    Hughes, K.3
  • 15
    • 85012569986 scopus 로고
    • Drug delivery via aerosol system: Concept of 'aerosol inhaled.'
    • Smaldone GC. Drug delivery via aerosol system: concept of 'aerosol inhaled.' J Aerosol Med 1991; 4:229-35
    • (1991) J Aerosol Med , vol.4 , pp. 229-235
    • Smaldone, G.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.