-
1
-
-
85010105180
-
Chapter 601 - Physical tests and determinations: Aerosols
-
Rockville, MD
-
USP 26-NF 21. 2003. Chapter 601 - physical tests and determinations: aerosols. United States Pharmacopeia. Rockville, MD. 2105-2123.
-
(2003)
United States Pharmacopeia
, pp. 2105-2123
-
-
-
2
-
-
12244264565
-
Section 2.9.18 - Preparations for inhalation: Aerodynamic assessment of fine particles
-
Council of Europe, 67075 Strasbourg, France
-
rd ed. Suppl. 2001. Council of Europe, 67075 Strasbourg, France. 113-124.
-
(2002)
rd Ed.
, Issue.SUPPL. 2001
, pp. 113-124
-
-
-
3
-
-
0141540761
-
Next generation pharmaceutical impactor. Part 1: Design
-
Marple, V.A., D.L. Roberts, F.J. Romay, et al. 2003. Next generation pharmaceutical impactor. Part 1: Design. J. Aerosol Med. 16:283-299.
-
(2003)
J. Aerosol Med.
, vol.16
, pp. 283-299
-
-
Marple, V.A.1
Roberts, D.L.2
Romay, F.J.3
-
4
-
-
0141763840
-
Next generation pharmaceutical impactor. Part II: Calibration
-
Marple, V.A., B.A. Olson, K. Santhanakrishnan, et al. 2003. Next generation pharmaceutical impactor. Part II: Calibration. J. Aerosol Med. 16:301-324.
-
(2003)
J. Aerosol Med.
, vol.16
, pp. 301-324
-
-
Marple, V.A.1
Olson, B.A.2
Santhanakrishnan, K.3
-
6
-
-
1642456222
-
Contribution to the aerodynamic particle size assessment of nebulized drugs using the next generation impactor (NGI)
-
Aerosol Society, London
-
Jauernig, J., M. Hug, M. Knoch, et al. 2002. Contribution to the aerodynamic particle size assessment of nebulized drugs using the next generation impactor (NGI). In Drug Delivery to the Lungs - XIII. Aerosol Society, London, 44-47.
-
(2002)
Drug Delivery to the Lungs - XIII
, pp. 44-47
-
-
Jauernig, J.1
Hug, M.2
Knoch, M.3
-
7
-
-
0003577140
-
-
Wiley-Interscience, New York
-
Hinds, W.C. 1999. Properties, Behavior, and Measurement of Airborne Particles, 2nd ed. Wiley-Interscience, New York.
-
(1999)
Properties, Behavior, and Measurement of Airborne Particles, 2nd Ed.
-
-
Hinds, W.C.1
-
8
-
-
0015584825
-
Generation of monodisperse aerosol standards
-
Berglund, R.N., and B.Y.H. Liu. 1973. Generation of monodisperse aerosol standards. Environ. Sci. Technol. 7:147-153.
-
(1973)
Environ. Sci. Technol.
, vol.7
, pp. 147-153
-
-
Berglund, R.N.1
Liu, B.Y.H.2
-
10
-
-
0016079025
-
Characteristics of laminar jet impactors
-
Marple, V.A., and B.Y.H. Liu. 1974. Characteristics of laminar jet impactors. Environ. Sci. Technol. 8:648-654.
-
(1974)
Environ. Sci. Technol.
, vol.8
, pp. 648-654
-
-
Marple, V.A.1
Liu, B.Y.H.2
-
11
-
-
0021900631
-
Effect of ultra-Stokesian drag and particle interception on impaction characteristics
-
Rader, D.J., and V.A. Marple. 1985. Effect of ultra-Stokesian drag and particle interception on impaction characteristics. Aerosol Sci. Technol. 4:141-156.
-
(1985)
Aerosol Sci. Technol.
, vol.4
, pp. 141-156
-
-
Rader, D.J.1
Marple, V.A.2
-
12
-
-
0021588459
-
Effect of particle gravitational forces on the calculation of impactor efficiency curves
-
B.Y.H. Liu, D.Y.H. Pui, and H.J. Fission, eds. Elsevier, New York
-
Rader, D.J., and V.A. Marple. 1984. Effect of particle gravitational forces on the calculation of impactor efficiency curves. In B.Y.H. Liu, D.Y.H. Pui, and H.J. Fission, eds. Aerosols: Science, Technology and Industrial Application of Air borne Particles. Elsevier, New York, 123-126.
-
(1984)
Aerosols: Science, Technology and Industrial Application of Air Borne Particles
, pp. 123-126
-
-
Rader, D.J.1
Marple, V.A.2
-
13
-
-
12244293103
-
Differences in results obtained with the Next Generation Impactor (NGI) for Pulmicort® suspension and according to the CEN-standard EN-13544-1 for a NaF-solution
-
Aerosol Society, London
-
Jauernig, J., S. Ohl., M. Luber, et al. 2003. Differences in results obtained with the Next Generation Impactor (NGI) for Pulmicort® suspension and according to the CEN-standard EN-13544-1 for a NaF-solution. In Drug Delivery to the Lungs XIV. Aerosol Society, London, 41-44.
-
(2003)
Drug Delivery to the Lungs XIV
, pp. 41-44
-
-
Jauernig, J.1
Ohl, S.2
Luber, M.3
-
14
-
-
12244305305
-
Effects of the test set-up, formulation, and nebulizer type on aerodynamic droplet characteristics
-
R.N. Dalby, P.R. Byron, J. Peart, et al., eds, Davis Healthcare International Publishing, River Grove, IL
-
Jauernig, J., S. Ohl, M. Luber, et al. 2004. Effects of the test set-up, formulation, and nebulizer type on aerodynamic droplet characteristics. In R.N. Dalby, P.R. Byron, J. Peart, et al., eds. Respiratory Drug Delivery IX, Davis Healthcare International Publishing, River Grove, IL, 609-612.
-
(2004)
Respiratory Drug Delivery IX
, pp. 609-612
-
-
Jauernig, J.1
Ohl, S.2
Luber, M.3
-
15
-
-
12244268400
-
Nebulizer droplet size distribution - Refrigerated NGI at 15 L/min
-
R.N. Dalby, P.R. Byron, J. Peart, et al., eds, Davis Healthcare International Publishing, River Grove, IL
-
Berg, E., and L. Asking. 2004. Nebulizer droplet size distribution - refrigerated NGI at 15 L/min. In R.N. Dalby, P.R. Byron, J. Peart, et al., eds. Respiratory Drug Delivery IX, Davis Healthcare International Publishing, River Grove, IL, 361-363.
-
(2004)
Respiratory Drug Delivery IX
, pp. 361-363
-
-
Berg, E.1
Asking, L.2
-
16
-
-
0032890101
-
Undersizing of droplets from a vented nebulizer caused by aerosol heating during transit through an Andersen impactor
-
Finlay, W.H., and K.W. Stapleton. 1999. Undersizing of droplets from a vented nebulizer caused by aerosol heating during transit through an Andersen impactor. J. Aerosol Sci. 30:105-109.
-
(1999)
J. Aerosol Sci.
, vol.30
, pp. 105-109
-
-
Finlay, W.H.1
Stapleton, K.W.2
-
17
-
-
37549067087
-
A proposal for the use of the next generation pharmaceutical impactor (NGI) at flow rates between 15 and 30 L/min
-
R.N. Dalby, P.R. Byron, J. Peart, et al., eds. Davis Healthcare International Publishing, River Grove, IL
-
Marple, V., D. Roberts, and J. Mitchell. 2004. A proposal for the use of the next generation pharmaceutical impactor (NGI) at flow rates between 15 and 30 L/min. In R.N. Dalby, P.R. Byron, J. Peart, et al., eds. Respiratory Drug Delivery IX. Davis Healthcare International Publishing, River Grove, IL, 701-703.
-
(2004)
Respiratory Drug Delivery IX
, pp. 701-703
-
-
Marple, V.1
Roberts, D.2
Mitchell, J.3
|