메뉴 건너뛰기




Volumn 20, Issue 2, 2007, Pages 97-104

Determination of nebulizer droplet size distribution: A method based on impactor refrigeration

Author keywords

Droplet size distribution; Impaction; Nebulizer; Next generation pharmaceutical impactor (NGI)

Indexed keywords

SALBUTAMOL;

EID: 34249890213     PISSN: 08942684     EISSN: None     Source Type: Journal    
DOI: 10.1089/jam.2007.0556     Document Type: Article
Times cited : (54)

References (13)
  • 1
    • 0006379814 scopus 로고
    • Inhalation drugs in asthma management: State of the art, factors affecting delivery, and clinical response to inhaled drugs
    • Winter
    • Lewis, R.A. 1984. Inhalation drugs in asthma management: state of the art, factors affecting delivery, and clinical response to inhaled drugs. NER Allergy Proc. Winter 5:23-33.
    • (1984) NER Allergy Proc , vol.5 , pp. 23-33
    • Lewis, R.A.1
  • 2
    • 0032890101 scopus 로고    scopus 로고
    • Undersizing of droplets from a vented nebulizer caused by aerosol heating during transit through an Andersen impactor
    • Finlay, W.H., and K.W. Stapleton. 1999. Undersizing of droplets from a vented nebulizer caused by aerosol heating during transit through an Andersen impactor. J. Aerosol Sci. 30:105-109.
    • (1999) J. Aerosol Sci , vol.30 , pp. 105-109
    • Finlay, W.H.1    Stapleton, K.W.2
  • 4
    • 54949127019 scopus 로고    scopus 로고
    • Validation of a test set-up utilizing the 28.3 L/min Andersen cascade impactor (ACI) for the aerodynamic assessment of nebulized aqueous formulations
    • R.N. Dalby, P.R. Byron, J. Peart, and S.J. Farr, eds, Davis Horwood International Publishing Ltd, Raleigh, NC
    • Jauernig, J., U. Schusnig, M. Hug, and M. Keller. 2002. Validation of a test set-up utilizing the 28.3 L/min Andersen cascade impactor (ACI) for the aerodynamic assessment of nebulized aqueous formulations. In R.N. Dalby, P.R. Byron, J. Peart, and S.J. Farr, eds. Respiratory Drug Delivery VIII, Vol. II. Davis Horwood International Publishing Ltd, Raleigh, NC, 537-539.
    • (2002) Respiratory Drug Delivery VIII , vol.2 , pp. 537-539
    • Jauernig, J.1    Schusnig, U.2    Hug, M.3    Keller, M.4
  • 5
    • 29844453071 scopus 로고    scopus 로고
    • Use of the Next Generation Pharmaceutical Impactor of particle size distribution measurements of live viral aerosol vaccines
    • Leung, K., E. Louca, M. Gray, G. Tipples, and A.L. Coates, 2005. Use of the Next Generation Pharmaceutical Impactor of particle size distribution measurements of live viral aerosol vaccines. J. Aerosol Med. 18:414-426.
    • (2005) J. Aerosol Med , vol.18 , pp. 414-426
    • Leung, K.1    Louca, E.2    Gray, M.3    Tipples, G.4    Coates, A.L.5
  • 6
    • 0035008993 scopus 로고    scopus 로고
    • Validation of laser diffraction Method as a substitute of cascade impaction in the European Project for a Nebulizer Standard
    • None, L.V, D. Grimbert, M.H. Becquemin, E. Boissinot, A. Le Pape, E. Lemarie, and P. Diot, 2001. Validation of laser diffraction Method as a substitute of cascade impaction in the European Project for a Nebulizer Standard. J. Aerosol Med. 14:107-114.
    • (2001) J. Aerosol Med , vol.14 , pp. 107-114
    • None, L.V.1    Grimbert, D.2    Becquemin, M.H.3    Boissinot, E.4    Le Pape, A.5    Lemarie, E.6    Diot, P.7
  • 8
    • 0017518450 scopus 로고
    • The size of soluble aerosol particles as a function of the humidity of the air. Application to the human respiratory tract
    • Ferron, G.A. 1977. The size of soluble aerosol particles as a function of the humidity of the air. Application to the human respiratory tract. J. Aerosol Sci. 8:251-267.
    • (1977) J. Aerosol Sci , vol.8 , pp. 251-267
    • Ferron, G.A.1
  • 9
    • 12244300136 scopus 로고    scopus 로고
    • Next Generation Pharmaceutical Impactor: A new impactor for pharmaceutical inhaler testing. Part III. Extension of archival calibration to 15 L/min
    • Marple, V.A., B.A. Olson, K. Santhanakrishnan, D.L. Roberts, J.P. Mitchell, and B.L. Hudson-Curtis. 2004. Next Generation Pharmaceutical Impactor: a new impactor for pharmaceutical inhaler testing. Part III. Extension of archival calibration to 15 L/min. J. Aerosol Med. 17:335-343.
    • (2004) J. Aerosol Med , vol.17 , pp. 335-343
    • Marple, V.A.1    Olson, B.A.2    Santhanakrishnan, K.3    Roberts, D.L.4    Mitchell, J.P.5    Hudson-Curtis, B.L.6
  • 11
    • 0031836818 scopus 로고    scopus 로고
    • Variations in predicted regional lung deposition of salbutamol sulphae between 19 nebulizer types
    • Finlay, W.H., K.W. Stapleton, and P. Zuberbuhler, 1998. Variations in predicted regional lung deposition of salbutamol sulphae between 19 nebulizer types. J. Aerosol Med. 11:65-80.
    • (1998) J. Aerosol Med , vol.11 , pp. 65-80
    • Finlay, W.H.1    Stapleton, K.W.2    Zuberbuhler, P.3
  • 12
    • 1642515071 scopus 로고    scopus 로고
    • Cascade impactors for the size characterization of aerosols from medical inhalers: Their uses and limitations
    • Mitchell, J.M., and M.W. Nagel, 2003. Cascade impactors for the size characterization of aerosols from medical inhalers: their uses and limitations. J. Aerosol Med. 16:341-377.
    • (2003) J. Aerosol Med , vol.16 , pp. 341-377
    • Mitchell, J.M.1    Nagel, M.W.2
  • 13
    • 0014225653 scopus 로고
    • Operating characteristics of some compressed-air nebulizers
    • Mercer, T.T., M.I. Tillery, and H.Y. Chow. 1968. Operating characteristics of some compressed-air nebulizers. Am. Ind. Hyg. Assoc. J. 29:66-78.
    • (1968) Am. Ind. Hyg. Assoc. J , vol.29 , pp. 66-78
    • Mercer, T.T.1    Tillery, M.I.2    Chow, H.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.