-
1
-
-
0019858318
-
Idiopathic interstitial pneumonia following bone marrow transplantation: The relationship with total body irradiation
-
IOBPD3 0360-3016. 10.1016/0360-3016(81)90032-8
-
T. J. Keane, J. van Dyk, and W. D. Rider, " Idiopathic interstitial pneumonia following bone marrow transplantation: The relationship with total body irradiation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 7, 1365-1370 (1981). 10.1016/0360-3016(81)90032-8
-
(1981)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.7
, pp. 1365-1370
-
-
Keane, T.J.1
Van Dyk, J.2
Rider, W.D.3
-
2
-
-
0019431047
-
Radiation pneumonitis following large single dose irradiation: A re-evaluation based on absolute dose to the lung
-
IOBPD3 0360-3016. 10.1016/0360-3016(81)90131-0
-
J. Van Dyk, T. J. Keane, S. Kan, W. D. Rider, and C. J. H. Fryers " Radiation pneumonitis following large single dose irradiation: a re-evaluation based on absolute dose to the lung.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 7, 461-467 (1981). 10.1016/0360-3016(81)90131-0
-
(1981)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.7
, pp. 461-467
-
-
Van Dyk, J.1
Keane, T.J.2
Kan, S.3
Rider, W.D.4
Fryers, C.J.H.5
-
3
-
-
0021993762
-
Lung damage following bone marrow transplantation: I. the contribution of irradiation
-
IOBPD3 0360-3016. 10.1016/0360-3016(85)90112-9
-
B. L. Cardozo, H. Zoetelief, D. W. van Bekkum, C. Zurcher, and A. Hagenbeek, " Lung damage following bone marrow transplantation: I. The contribution of irradiation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 11, 907-914 (1985). 10.1016/0360-3016(85)90112-9
-
(1985)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.11
, pp. 907-914
-
-
Cardozo, B.L.1
Zoetelief, H.2
Van Bekkum, D.W.3
Zurcher, C.4
Hagenbeek, A.5
-
4
-
-
0036471962
-
Lethal pulmonary complications significantly correlate with individually assessed mean lung dose in patients with hematologic malignancies treated with total body irradiation
-
DOI 10.1016/S0360-3016(01)02589-5, PII S0360301601025895
-
A. Della Volpe, A. J. Ferreri, C. Annaloro, P. Mangili, A. Rosso, R. Calandrino, E. Villa, G. Lambertenghi-Delliliers, and C. Fiorino, " Lethal pulmonary complications significantly correlate with individually assessed mean lung dose in patients with hematologic malignancies treated with total body irradiation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 52, 483-488 (2002). 10.1016/S0360-3016(01)02589-5 (Pubitemid 34170853)
-
(2002)
International Journal of Radiation Oncology Biology Physics
, vol.52
, Issue.2
, pp. 483-488
-
-
Volpe, A.D.1
Ferreri, A.J.M.2
Annaloro, C.3
Mangili, P.4
Rosso, A.5
Calandrino, R.6
Villa, E.7
Lambertenghi-Deliliers, G.8
Fiorino, C.9
-
5
-
-
33750479495
-
Biologically effective dose in total-body irradiation and hematopoietic stem cell transplantation
-
DOI 10.1007/s00066-006-1528-6
-
H. B. Kal, L. van Kempen-Harteveld, M. H. Heijenbrok, and H. Struikmans, " Biologically effective dose in total body irradiation and hematopoietic stem cell transplantation.," Strahlenther. Onkol. STONE4 0179-7158 182, 672-679 (2006). 10.1007/s00066-006-1528-6 (Pubitemid 44657655)
-
(2006)
Strahlentherapie und Onkologie
, vol.182
, Issue.11
, pp. 672-679
-
-
Kal, H.B.1
Van Kempen-Harteveld, M.L.2
Heijenbrok-Kal, M.H.3
Struikmans, H.4
-
6
-
-
0035476292
-
Comparison of two total body irradiation fractionation regimens with respect to acute and late pulmonary toxicity
-
ZZZZZZ 0008-543X. 10.1002/1097-0142(20011001)92:7<1949::AID-CNCR17143. 0.CO;2-1
-
R. Gopal, C. S. Ha, S. L. Tucker, I. F. Khouri, S. A. Giralt, J. L. Gajewski, B. S. Andersson, J. D. Cox, and R. E. Champlin, " Comparison of two total body irradiation fractionation regimens with respect to acute and late pulmonary toxicity.," Cancer ZZZZZZ 0008-543X 92, 1949-1958 (2001). 10.1002/1097-0142(20011001)92:7<1949::AID-CNCR17143.0.CO;2-1
-
(2001)
Cancer
, vol.92
, pp. 1949-1958
-
-
Gopal, R.1
Ha, C.S.2
Tucker, S.L.3
Khouri, I.F.4
Giralt, S.A.5
Gajewski, J.L.6
Andersson, B.S.7
Cox, J.D.8
Champlin, R.E.9
-
7
-
-
0032850539
-
In-vivo dosimetry by diode semiconductors in combination with portal films during TBI: Reporting a 5-year clinical experience
-
DOI 10.1016/S0167-8140(99)00104-8, PII S0167814099001048
-
P. Mangili, C. Fiorino, A. Rosso, G. M. Cattaneo, R. Parisi, E. Villa, and R. Calandrino, " In-vivo dosimetry by diode semiconductors in combination with portal films during TBI: Reporting a 5-year clinical experience.," Radiother. Oncol. RAONDT 0167-8140 52, 269-276 (1999). 10.1016/S0167-8140(99)00104-8 (Pubitemid 29486648)
-
(1999)
Radiotherapy and Oncology
, vol.52
, Issue.3
, pp. 269-276
-
-
Mangili, P.1
Fiorino, C.2
Rosso, A.3
Mauro Cattaneo, G.4
Parisi, R.5
Villa, E.6
Calandrino, R.7
-
8
-
-
34748820553
-
20 Years of experience in static intensity-modulated total-body irradiation and lung toxicity: Results in 257 consecutive patients
-
DOI 10.1007/s00066-007-1656-7
-
R. A. Schneider, J. Schultze, J. M. Jensen, D. Hebbinghaus, and R. M. Galalae, " 20 years of experience in static intensity-modulated total-body irradiation and lung toxicity. Results in 257 consecutive patients.," Strahlenther. Onkol. STONE4 0179-7158 183, 545-551 (2007). 10.1007/s00066-007- 1656-7 (Pubitemid 47482154)
-
(2007)
Strahlentherapie und Onkologie
, vol.183
, Issue.10
, pp. 545-551
-
-
Schneider, R.A.1
Schultze, J.2
Jensen, J.M.3
Hebbinghaus, D.4
Galalae, R.5
Kimmig, B.N.6
-
9
-
-
0033556681
-
In vivo dosimetry during external photon beam radiotherapy
-
DOI 10.1016/S0360-3016(98)00341-1, PII S0360301698003411
-
M. Essers and B. Mijnheer, " In vivo dosimetry using external photon beam radiotherapy.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 43, 245-259 (1999). 10.1016/S0360-3016(98)00341-1 (Pubitemid 29091462)
-
(1999)
International Journal of Radiation Oncology Biology Physics
, vol.43
, Issue.2
, pp. 245-259
-
-
Essers, M.1
Mijnheer, B.J.2
-
10
-
-
0028909508
-
Verification of an on line in vivo semiconductor dosimetry system for TBI with two TLD procedures
-
RAONDT 0167-8140. 10.1016/0167-8140(94)01490-T
-
F. Sanchez-Doblado, J. A. Terron, B. Sanchez-Nieto, R. Arrans, L. Errazquin, D. Biggs, C. Lee, L. Nunez, A. Delgado, and J. L. Muniz, " Verification of an on line in vivo semiconductor dosimetry system for TBI with two TLD procedures.," Radiother. Oncol. RAONDT 0167-8140 34, 73-77 (1995). 10.1016/0167-8140(94)01490-T
-
(1995)
Radiother. Oncol.
, vol.34
, pp. 73-77
-
-
Sanchez-Doblado, F.1
Terron, J.A.2
Sanchez-Nieto, B.3
Arrans, R.4
Errazquin, L.5
Biggs, D.6
Lee, C.7
Nunez, L.8
Delgado, A.9
Muniz, J.L.10
-
11
-
-
35448961719
-
Total body irradiation, toward optimal individual delivery: Dose evaluation with metal oxide field effect transducers, thermoluminescence detectors, and a treatment planning system
-
IOBPD3 0360-3016. 10.1016/j.ijrob2007.07.2334
-
E. J. Bloemen-Van Gurp, B. J. Mijnheer, T. A. Verschueren, and P. Lambin, " Total body irradiation, toward optimal individual delivery: Dose evaluation with metal oxide field effect transducers, thermoluminescence detectors, and a treatment planning system.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 69, 1297-1304 (2007). 10.1016/j.ijrobp.2007.07. 2334
-
(2007)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.69
, pp. 1297-1304
-
-
Bloemen-Van Gurp, E.J.1
Mijnheer, B.J.2
Verschueren, T.A.3
Lambin, P.4
-
12
-
-
21144457223
-
Characterization of a new MOSFET detector configuration for in vivo skin dosimetry
-
DOI 10.1118/1.1924328
-
P. Scalchi, P. Francescon, and P. Rajaguru, " Characterization of a new MOSFET detector configuration for in vivo skin dosimetry.," Med. Phys. MPHYA6 0094-2405 32, 1571-1578 (2005). 10.1118/1.1924328 (Pubitemid 40880551)
-
(2005)
Medical Physics
, vol.32
, Issue.6
, pp. 1571-1578
-
-
Scalchi, P.1
Francescon, P.2
Rajaguru, P.3
-
13
-
-
0023884588
-
Verification of total body photon irradiation dosimetry techniques
-
MPHYA6 0094-2405. 10.1118/1.596232
-
T. H. Kirby, W. F. Hanson, and D. A. Cates, " Verification of total body photon irradiation dosimetry techniques.," Med. Phys. MPHYA6 0094-2405 15, 364-369 (1988). 10.1118/1.596232
-
(1988)
Med. Phys.
, vol.15
, pp. 364-369
-
-
Kirby, T.H.1
Hanson, W.F.2
Cates, D.A.3
-
14
-
-
0032413065
-
Midplane dose determination during total body irradiation using in vivo dosimetry
-
DOI 10.1016/S0167-8140(98)00094-2, PII S0167814098000942
-
M. Ribas, N. Jornet, T. Eudaldo, D. Carabante, M. A. Duch, M. Ginjaume, G. Gomez de Segura, and F. Sanchez-Doblado, " Midplane dose determination during total body irradiation using in vivo dosimetry.," Radiother. Oncol. RAONDT 0167-8140 49, 91-98 (1998). 10.1016/S0167-8140(98)00094-2 (Pubitemid 29005209)
-
(1998)
Radiotherapy and Oncology
, vol.49
, Issue.1
, pp. 91-98
-
-
Ribas, M.1
Jornet, N.2
Eudaldo, T.3
Carabante, D.4
Duch, M.A.5
Ginjaume, M.6
Gomez De Segura, G.7
Sanchez-Doblado, F.8
-
15
-
-
0031744990
-
Thermoluminescence dosimetry applied to in vivo dose measurements for total body irradiation techniques
-
DOI 10.1016/S0167-8140(98)00013-9, PII S0167814098000139
-
M. A. Duch, M. Ginjaume, H. Chakkor, X. Ortega, N. Jornet, and M. Ribas, " Thermoluminescent dosimetry applied to in vivo dose measurements for total body irradiation techniques.," Radiother. Oncol. RAONDT 0167-8140 47, 319-324 (1998). 10.1016/S0167-8140(98)00013-9 (Pubitemid 28293655)
-
(1998)
Radiotherapy and Oncology
, vol.47
, Issue.3
, pp. 319-324
-
-
Duch, M.A.1
Ginjaume, M.2
Chakkor, H.3
Ortega, X.4
Jornet, N.5
Ribas, M.6
-
16
-
-
0035194718
-
Total body irradiation using a modified standing technique: A single institution 7 year experience
-
S. V. Harden, D. S. Routsis, A. R. Geater, S. J. Thomas, P. J. Taylor, R. E. Marcus, and M. V. Williams, " Total body irradiation using a modified standing technique: a single institution 7 year experience.," Br. J. of Radiol. 74, 1041-1047 (2001).
-
(2001)
Br. J. of Radiol.
, vol.74
, pp. 1041-1047
-
-
Harden, S.V.1
Routsis, D.S.2
Geater, A.R.3
Thomas, S.J.4
Taylor, P.J.5
Marcus, R.E.6
Williams, M.V.7
-
17
-
-
0035194718
-
Total body irradiation using a modified standing technique: A single institution 7 year experience
-
BJRAAP 0007-1285.
-
S. Harden, D. Routsis, A. Geater, S. J. Thomas, P. J. Taylor, R. E. Marcus, and M. V. Williams, " Total body irradiation using a modified standing technique: A single institution 7 year experience.," Br. J. Radiol. BJRAAP 0007-1285 74, 1041-1047 (2001).
-
(2001)
Br. J. Radiol.
, vol.74
, pp. 1041-1047
-
-
Harden, S.1
Routsis, D.2
Geater, A.3
Thomas, S.J.4
Taylor, P.J.5
Marcus, R.E.6
Williams, M.V.7
-
18
-
-
0003511488
-
-
Task Grou29, Radiation Therapy Committee, American Association of Physicists in Medicine Report No. 17.
-
J. Van Dyk, J. M. Galvin, G. P. Glasgow, and E. B. Podgorsak, " The physical aspects of total and half body photon irradiation.," Task Group 29, Radiation Therapy Committee, American Association of Physicists in Medicine Report No. 17, 1986.
-
(1986)
The Physical Aspects of Total and Half Body Photon Irradiation
-
-
Van Dyk, J.1
Galvin, J.M.2
Glasgow, G.P.3
Podgorsak, E.B.4
-
19
-
-
14844290219
-
Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system
-
DOI 10.1016/j.apradiso.2004.10.009, PII S0969804304005512
-
M. Anton, " Development of a secondary standard for the absorbed dose to water based on the alanine EPR dosimetry system.," Appl. Radiat. Isot. ARISEF 0969-8043 62, 779-795 (2005). 10.1016/j.apradiso.2004.10.009 (Pubitemid 40342988)
-
(2005)
Applied Radiation and Isotopes
, vol.62
, Issue.5
, pp. 779-795
-
-
Anton, M.1
-
20
-
-
0030293959
-
Progress towards an alanine/ESR therapy level reference dosimetry service at NPL
-
DOI 10.1016/S0969-8043(96)00174-1, PII S0969804396001741
-
P. H. G. Sharpe, K. Rajendran, and J. P. Sephton, " Progress towards an alanine/ESR therapy level reference dosimetry service at NPL.," Appl. Radiat. Isot. ARISEF 0969-8043 47, 1171-1175 (1996). 10.1016/S0969-8043(96) 00174-1 (Pubitemid 27057815)
-
(1996)
Applied Radiation and Isotopes
, vol.47
, Issue.11-12
, pp. 1171-1175
-
-
Sharpe, P.H.G.1
Rajendran, K.2
Sephton, J.P.3
-
22
-
-
33751166576
-
Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt
-
DOI 10.1088/0031-9155/51/21/003, PII S0031915506285956, 003
-
M. Anton, " Uncertainties in alanine/ESR dosimetry at the Physikalisch-Technische Bundesanstalt.," Phys. Med. Biol. PHMBA7 0031-9155 51, 5419-5440 (2006). 10.1088/0031-9155/51/21/003 (Pubitemid 44773323)
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.21
, pp. 5419-5440
-
-
Anton, M.1
-
23
-
-
47149098402
-
Response of the alanine/ESR dosimetry system to MV x-rays relative to C 60 o radiation
-
PHMBA7 0031-9155. 10.1088/0031-9155/53/10/020
-
M. Anton, R. P. Kapsch, M. Krystek, and F. Renner, " Response of the alanine/ESR dosimetry system to MV x-rays relative to C 60 o radiation.," Phys. Med. Biol. PHMBA7 0031-9155 53, 2753-2770 (2008). 10.1088/0031-9155/53/10/ 020
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 2753-2770
-
-
Anton, M.1
Kapsch, R.P.2
Krystek, M.3
Renner, F.4
-
24
-
-
45849141262
-
In vivo alanine/electron spin resonance (ESR) dosimetry in radiotherapy of prostate cancer: A feasibility study
-
RAONDT 0167-8140. 10.1016/j.radonc.2008.03.017
-
D. Wagner, M. Anton, H. Vorwerk, T. Gsanger, H. Christiansen, B. Poppe, C. F. Hess, and R. M. Hermann, " In vivo alanine/electron spin resonance (ESR) dosimetry in radiotherapy of prostate cancer: A feasibility study.," Radiother. Oncol. RAONDT 0167-8140 88, 140-147 (2008). 10.1016/j.radonc.2008.03. 017
-
(2008)
Radiother. Oncol.
, vol.88
, pp. 140-147
-
-
Wagner, D.1
Anton, M.2
Vorwerk, H.3
Gsanger, T.4
Christiansen, H.5
Poppe, B.6
Hess, C.F.7
Hermann, R.M.8
-
25
-
-
79551668872
-
Code of practice for the absolute dose determination in high energy photon and electron beams
-
NCS
-
NCS, " Code of practice for the absolute dose determination in high energy photon and electron beams.," Netherlands Commission of Radiation Dosimetry Report No. 18, 2008.
-
(2008)
Netherlands Commission of Radiation Dosimetry Report No. 18
-
-
-
26
-
-
0024396377
-
A simple method for calculation of prescribed dose for total-body photon irradiation
-
IOBPD3 0360-3016, Suppl. 1. 10.1016/0360-3016(89)90392-1
-
W. Curran, J. M. Galvin, and G. J. D'Angio, " A simple method for calculation of prescribed dose for total-body photon irradiation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 12, Suppl. 1 (1986). 10.1016/0360-3016(89)90392-1
-
(1986)
Int. J. Radiat. Oncol., Biol., Phys.
, vol.12
-
-
Curran, W.1
Galvin, J.M.2
D'Angio, G.J.3
-
28
-
-
0020331280
-
Dosimetry by ESR spectroscopy of alanine
-
IJARAY 0020-708X. 10.1016/0020-708X(82)90238-1
-
D. F. Regulla and U. Deffner, " Dosimetry by ESR spectroscopy of alanine.," Int. J. Appl. Radiat. Isot. IJARAY 0020-708X 33, 1101-1114 (1982). 10.1016/0020-708X(82)90238-1
-
(1982)
Int. J. Appl. Radiat. Isot.
, vol.33
, pp. 1101-1114
-
-
Regulla, D.F.1
Deffner, U.2
-
29
-
-
0027607989
-
The application of EPR dosimetry for radiotherapy and radiation protection
-
IJARAY 0020-708X. 10.1016/0969-8043(93)90042-9
-
R. Kudynski, J. Kudinska, and H. A. Buckmaster, " The application of EPR dosimetry for radiotherapy and radiation protection.," Int. J. Appl. Radiat. Isot. IJARAY 0020-708X 44, 903-906 (1993). 10.1016/0969-8043(93)90042-9
-
(1993)
Int. J. Appl. Radiat. Isot.
, vol.44
, pp. 903-906
-
-
Kudynski, R.1
Kudinska, J.2
Buckmaster, H.A.3
-
30
-
-
0030293066
-
One year of experience with alanine dosimetry in radiotherapy
-
DOI 10.1016/S0969-8043(96)00040-1, PII S0969804396000401
-
B. Schaeken and P. Scalliet, " One year of experience with alanine dosimetry in radiotherapy.," Appl. Radiat. Isot. ARISEF 0969-8043 47, 1177-1182 (1996). 10.1016/S0969-8043(96)00040-1 (Pubitemid 27057816)
-
(1996)
Applied Radiation and Isotopes
, vol.47
, Issue.11-12
, pp. 1177-1182
-
-
Schaeken, B.1
Scalliet, P.2
-
31
-
-
0034140424
-
Assessment of an alanine EPR dosimetry technique with enhanced precision and accuracy
-
NIMRD9 0167-5087.
-
R. B. Hayes, E. H. Haskel, A. Wieser, A. A. Romanyukha, B. L. Hardy, and J. K. Barrus, " Assessment of an alanine EPR dosimetry technique with enhanced precision and accuracy.," Nucl. Instrum. Methods Phys. Res. NIMRD9 0167-5087 A440, 453-461 (2000).
-
(2000)
Nucl. Instrum. Methods Phys. Res.
, vol.440
, pp. 453-461
-
-
Hayes, R.B.1
Haskel, E.H.2
Wieser, A.3
Romanyukha, A.A.4
Hardy, B.L.5
Barrus, J.K.6
-
32
-
-
33744804084
-
Comparison of the standards for absorbed dose to water of the PTB, Germany and the BIPM for 60Co y-rays
-
MTRGAU 0026-1394, Tech. Suppl.. 10.1088/0026-1394/43/1A/06005
-
C. Kessler, P. J. Allisy, D. T. Burns, A. Krauss, and R. P. Kapsch, " Comparison of the standards for absorbed dose to water of the PTB, Germany and the BIPM for 60Co y-rays.," Metrologia MTRGAU 0026-1394 43, Tech. Suppl. 06005 (2006). 10.1088/0026-1394/43/1A/06005
-
(2006)
Metrologia
, vol.43
, pp. 06005
-
-
Kessler, C.1
Allisy, P.J.2
Burns, D.T.3
Krauss, A.4
Kapsch, R.P.5
-
33
-
-
0030805692
-
The influence of x-ray energy on lung dose uniformity in total-body irradiation
-
DOI 10.1016/S0360-3016(97)00286-1, PII S0360301697002861
-
K. Ekstrand, K. Greven, and Q. Wu, " The influence of x-ray energy on lung dose uniformity in total body irradiation.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 38, 1131-1136 (1997). 10.1016/S0360- 3016(97)00286-1 (Pubitemid 27353695)
-
(1997)
International Journal of Radiation Oncology Biology Physics
, vol.38
, Issue.5
, pp. 1131-1136
-
-
Ekstrand, K.1
Greven, K.2
Wu, Q.3
-
34
-
-
4644266572
-
Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations
-
DOI 10.1016/j.radonc.2004.06.007, PII S0167814004003202
-
A. Nisbet, I. Beange, H. S. Vollmar, C. Irvine, A. Morgan, and D. I. Thwaites, " Dosimetric verification of a commercial collapsed cone algorithm in simulated clinical situations.," Radiother. Oncol. RAONDT 0167-8140 73, 79-88 (2004). 10.1016/j.radonc.2004.06.007 (Pubitemid 39304129)
-
(2004)
Radiotherapy and Oncology
, vol.73
, Issue.1
, pp. 79-88
-
-
Nisbet, A.1
Beange, I.2
Vollmar, H.-S.3
Irvine, C.4
Morgan, A.5
Thwaites, D.I.6
-
35
-
-
65649096221
-
The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumor coverage
-
RAONDT 0167-8140. 10.1016/j.radonc.2009.01.008
-
L. R. Aarup, A. E. Nahum, C. Zacharatou, T. J. Nøttrup, T. Knöös, H. Nyström, L. Specht, E. Wieslander, and S. S. Korreman, " The effect of different lung densities on the accuracy of various radiotherapy dose calculation methods: Implications for tumor coverage.," Radiother. Oncol. RAONDT 0167-8140 91, 405-414 (2009). 10.1016/j.radonc.2009.01. 008
-
(2009)
Radiother. Oncol.
, vol.91
, pp. 405-414
-
-
Aarup, L.R.1
Nahum, A.E.2
Zacharatou, C.3
Nøttrup, T.J.4
Knöös, T.5
Nyström, H.6
Specht, L.7
Wieslander, E.8
Korreman, S.S.9
-
36
-
-
0037605852
-
In vivo alanine/EPR dosimetry in daily clinical practice: A feasibility study
-
DOI 10.1016/S0360-3016(03)00196-2
-
B. Ciesielski, K. Schultka, A. Kobierska, R. Nowak, and Z. Peimel-Stuglik, " In vivo alanine/EPR dosimetry in daily clinical practice: A feasibility study.," Int. J. Radiat. Oncol., Biol., Phys. IOBPD3 0360-3016 56, 899-905 (2003). 10.1016/S0360-3016(03)00196-2 (Pubitemid 36677387)
-
(2003)
International Journal of Radiation Oncology Biology Physics
, vol.56
, Issue.3
, pp. 899-905
-
-
Ciesielski, B.1
Schultka, K.2
Kobierska, A.3
Nowak, R.4
Peimel-Stuglik, Z.5
-
37
-
-
4344649765
-
Total body irradiation prior to bone marrow transplantation: Some aspects of fifty year experience
-
1107-0625
-
L. Gocheva, " Total body irradiation prior to bone marrow transplantation: some aspects of fifty year experience.," J. Buon. 9, 147-160 (2004). 1107-0625
-
(2004)
J. Buon.
, vol.9
, pp. 147-160
-
-
Gocheva, L.1
-
38
-
-
42649130651
-
Postirradiation effects in alanine dosimeter probes of two different suppliers
-
DOI 10.1088/0031-9155/53/5/006, PII S003191550863403X
-
M. Anton, " Postirradiation effects in alanine dosimeter probes of two different suppliers.," Phys. Med. Biol. PHMBA7 0031-9155 53, 1241-1258 (2008). 10.1088/0031-9155/53/5/006 (Pubitemid 351594424)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.5
, pp. 1241-1258
-
-
Anton, M.1
|