메뉴 건너뛰기




Volumn 32, Issue 6, 2005, Pages 1571-1578

Characterization of a new MOSFET detector configuration for in vivo skin dosimetry

Author keywords

In vivo dosimetry; MOSFET; Skin dose; Total body irradiation

Indexed keywords

IRRADIATION; METALS; MOS DEVICES; MOSFET DEVICES; OXIDE SEMICONDUCTORS; RADIATION DECONTAMINATION; RADIOTHERAPY; STATIC RANDOM ACCESS STORAGE;

EID: 21144457223     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1924328     Document Type: Conference Paper
Times cited : (51)

References (14)
  • 3
    • 0031899494 scopus 로고    scopus 로고
    • Calibration of a MOSFET detection system for 6 MV in vivo dosimetry
    • P. Scalchi and P. Francescon, "Calibration of a MOSFET detection system for 6 MV in vivo dosimetry," Int. J. Radiat. Oncol., Biol., Phys. 40, 987-993 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.40 , pp. 987-993
    • Scalchi, P.1    Francescon, P.2
  • 4
  • 5
    • 0027172666 scopus 로고
    • X-ray surface dose measurements using TLD extrapolation
    • T. Kron, A. Elliot, T. Wong, G. Showell B. Clubb P. T. Metcalfe, T. Kron, A. Elliot, T. Wong, G. Showell, B. Clubb, and P. T. Metcalfe, "X-ray surface dose measurements using TLD extrapolation," Med. Phys. 20, 703-711 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 703-711
    • Kron, T.1    Elliot, A.2    Wong, T.3    Showell, G.4    Clubb, B.5    Metcalfe, P.T.6
  • 7
    • 0028213977 scopus 로고
    • Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter
    • M. Soubra, J. Cygler, and G. Mackay, "Evaluation of a dual bias dual metal oxide-silicon semiconductor field effect transistor detector as radiation dosimeter," Med. Phys. 21, 567-572 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 567-572
    • Soubra, M.1    Cygler, J.2    Mackay, G.3
  • 8
    • 0033853810 scopus 로고    scopus 로고
    • Measurement of radiotherapy x-ray skin dose on a chest wall phantom
    • K. Y. Quach, J. Morales, M. J. Butson, A. B. Rosenfeld, and P. E. Metcalfe, "Measurement of radiotherapy x-ray skin dose on a chest wall phantom," Med. Phys. 27, 1676-1680 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1676-1680
    • Quach, K.Y.1    Morales, J.2    Butson, M.J.3    Rosenfeld, A.B.4    Metcalfe, P.E.5
  • 9
    • 0029035150 scopus 로고
    • BEAM: A Monte Carlo code to simulate radiotherapy treatment unit
    • D. W. O. Rogers, B. A. Faddegon, J. X. Ding, C. Ma, and J. We, "BEAM: A Monte Carlo code to simulate radiotherapy treatment unit," Med. Phys. 22, 503-524 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 503-524
    • Rogers, D.W.O.1    Faddegon, B.A.2    Ding, J.X.3    Ma, C.4    We, J.5
  • 10
    • 0029877277 scopus 로고    scopus 로고
    • 3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC)
    • I. Kawrakow, M. Fippel, and K. Friedrich, "3D electron dose calculation using a voxel based Monte Carlo algorithm (VMC)," Med. Phys. 23, 445-457 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 445-457
    • Kawrakow, I.1    Fippel, M.2    Friedrich, K.3
  • 11
    • 0032860849 scopus 로고    scopus 로고
    • Dose measurements compared with Monte Carlo simulation of narrow 6 MV multileaf collimator shaped photon beam
    • K. De Vlamynck, H. Palmans, F. Verhaegen, C. De Wagter, W. De Neve, and H. Thierens, "Dose measurements compared with Monte Carlo simulation of narrow 6 MV multileaf collimator shaped photon beam," Med. Phys. 26, 1874-1882 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1874-1882
    • De Vlamynck, K.1    Palmans, H.2    Verhaegen, F.3    De Wagter, C.4    De Neve, W.5    Thierens, H.6
  • 12
    • 0037320058 scopus 로고    scopus 로고
    • Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code
    • P. Francescon, S. Cora, and P. Chiovati, "Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code," Med. Phys. 30, 144-157 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 144-157
    • Francescon, P.1    Cora, S.2    Chiovati, P.3
  • 13
    • 0025242385 scopus 로고
    • Determination of build-up region over-response corrections for a Markus-type chamber
    • D. E. Mellenberg, "Determination of build-up region over-response corrections for a Markus-type chamber," Med. Phys. 17, 1041-1044 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 1041-1044
    • Mellenberg, D.E.1
  • 14
    • 0029518433 scopus 로고
    • MOSFETs dosimeters: The role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fields
    • A. B. Rosenfeld, M. G. Carolan, G. J. Kaplan, B. J. Allen, and V. I. Khivrich, "MOSFETs dosimeters: the role of encapsulation on dosimetric characteristics in mixed gamma-neutron and megavoltage X-ray fields," IEEE Trans. Nucl. Sci. NS-42, N6, 1870-1877 (1995).
    • (1995) IEEE Trans. Nucl. Sci. , vol.NS-42 , Issue.N6 , pp. 1870-1877
    • Rosenfeld, A.B.1    Carolan, M.G.2    Kaplan, G.J.3    Allen, B.J.4    Khivrich, V.I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.