메뉴 건너뛰기




Volumn 1, Issue 1, 2010, Pages

Design and TEM simulation of a MEMS based microcantilever cardiac marker sensor

Author keywords

Acute myocardial infarction; Cardiac troponins; Microcantilever; Piezoresistive; Thermo electromechanical analysis

Indexed keywords

ACUTE MYOCARDIAL INFARCTION; CARDIAC TROPONINS; ELECTROMECHANICAL ANALYSIS; MICROCANTILEVER; PIEZO-RESISTIVE;

EID: 78649813623     PISSN: 19492944     EISSN: 19492952     Source Type: Journal    
DOI: 10.1115/1.3212821     Document Type: Article
Times cited : (5)

References (7)
  • 1
    • 0029951132 scopus 로고    scopus 로고
    • Comparison of Myoglobin, Creatine Kinase MB, and Cardiac Troponin I for Diagnosis of Acute Myocardial Infarction
    • Wu, A. H. B., Feng, Y. J., Contois, J. H., and Pervaiz, J., 1996, "Comparison of Myoglobin, Creatine Kinase MB, and Cardiac Troponin I for Diagnosis of Acute Myocardial Infarction," Ann. Clin. Lab Sci., 26, pp. 291-300.
    • (1996) Ann. Clin. Lab Sci , vol.26 , pp. 291-300
    • Wu, A.H.B.1    Feng, Y.J.2    Contois, J.H.3    Pervaiz, J.4
  • 3
    • 12444329382 scopus 로고    scopus 로고
    • A Flow-Through Amperometric Sensor for Micro-Analytical Systems
    • Pijanowska, D. G., Sprenkels, A. J., Olthuis, W., and Bergveld, P., 2003, "A Flow-Through Amperometric Sensor for Micro-Analytical Systems," Sens. Actuators B, 91 1-3, pp. 98-102.
    • (2003) Sens. Actuators B , vol.91 , Issue.1-3 , pp. 98-102
    • Pijanowska, D.G.1    Sprenkels, A.J.2    Olthuis, W.3    Bergveld, P.4
  • 4
    • 26844520789 scopus 로고    scopus 로고
    • Simulation and Design of Piezoelectric Microcantilever Chemical Sensors
    • Zhou, W., Khaliq, A., Tang, Y., Ji, H.-F., Selmic, R. R., 2005, "Simulation and Design of Piezoelectric Microcantilever Chemical Sensors," Sens. Actuators, A, 125 1, pp. 69-75
    • (2005) Sens. Actuators, A , vol.125 , Issue.1 , pp. 69-75
    • Zhou, W.1    Khaliq, A.2    Tang, Y.3    Ji, H.-F.4    Selmic, R.R.5
  • 5
    • 0346280065 scopus 로고    scopus 로고
    • 2 Microcantilever for Microsensor Application
    • Tang, Y., Fang, J., Yan, X., and Ji, H.-F., 2004, "Fabrication and Characteriza-tion of SiO2 Microcantilever for Microsensor Application," Sens. Actuators B, 971, pp. 109-113.
    • (2004) Sens. Actuators B , vol.97 , pp. 109-113
    • Tang, Y.1    Fang, J.2    Yan, X.3    Ji, H.-F.4
  • 7
    • 4644291473 scopus 로고    scopus 로고
    • Diagnostic Value of Heart Fatty Acid-Binding Protein and Myoglobin in Patients Admitted With Chest Pain
    • Alansari, S. E., and Croal, B. L., 2004, "Diagnostic Value of Heart Fatty Acid-Binding Protein and Myoglobin in Patients Admitted With Chest Pain," Ann. Clin. Biochem., 41, pp. 391-396.
    • (2004) Ann. Clin. Biochem , vol.41 , pp. 391-396
    • Alansari, S.E.1    Croal, B.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.