메뉴 건너뛰기




Volumn 120, Issue 11, 2010, Pages 2277-2283

Anatomic verification of a novel method for precise intrascalar localization of cochlear implant electrodes in adult temporal bones using clinically available computed tomography

Author keywords

atlas based registration; Cochlear implants; computerized tomography; scala tympani; scala vestibuli

Indexed keywords

ALGORITHM; ANATOMICAL VARIATION; ARTICLE; AUDIOLOGY; BASILAR MEMBRANE; CADAVER; COCHLEA PROSTHESIS; COMPUTER ASSISTED TOMOGRAPHY; ELECTRODE; HUMAN; HUMAN TISSUE; MICRODISSECTION; OUTCOME ASSESSMENT; PRIORITY JOURNAL; PROCESS OPTIMIZATION; SCALA TYMPANI; SCALA VESTIBULI; STATISTICAL MODEL; TEMPORAL BONE; TISSUE MICROARRAY; VALIDATION PROCESS;

EID: 78349299387     PISSN: 0023852X     EISSN: None     Source Type: Journal    
DOI: 10.1002/lary.21104     Document Type: Article
Times cited : (67)

References (33)
  • 1
    • 0030224893 scopus 로고    scopus 로고
    • Factors affecting auditory performance of postlinguistically deaf adults using cochlear implants
    • Blamey P, Arndt P, Bergeron F, et al. Factors affecting auditory performance of postlinguistically deaf adults using cochlear implants. Audiol Neurotol 1996; 1: 293-306.
    • (1996) Audiol Neurotol , vol.1 , pp. 293-306
    • Blamey, P.1    Arndt, P.2    Bergeron, F.3
  • 2
    • 0033491520 scopus 로고    scopus 로고
    • Residual speech recognition and cochlear implant performance: Effects of implantation criteria
    • Rubinstein JT, Parkinson WS, Tyler RS, et al. Residual speech recognition and cochlear implant performance: effects of implantation criteria. Am J Otol 1999; 20: 445-452.
    • (1999) Am J Otol , vol.20 , pp. 445-452
    • Rubinstein, J.T.1    Parkinson, W.S.2    Tyler, R.S.3
  • 3
    • 0023682401 scopus 로고
    • Perceptual studies on cochlear implant patients with early onset of profound hearing impairment prior to normal development of auditory, speech, and language skills
    • Tong YC, Busby PA, Clark GM., Perceptual studies on cochlear implant patients with early onset of profound hearing impairment prior to normal development of auditory, speech, and language skills. J Acoust Soc Am 1988; 84: 951-962.
    • (1988) J Acoust Soc Am , vol.84 , pp. 951-962
    • Tong, Y.C.1    Busby, P.A.2    Clark, G.M.3
  • 4
    • 0034937032 scopus 로고    scopus 로고
    • Effects of electrode configuration and place of stimulation on speech perception with cochlear prostheses
    • Pfingst BE, Franck KH, Xu L, et al. Effects of electrode configuration and place of stimulation on speech perception with cochlear prostheses. J Assoc Res Otolaryngol 2001; 2: 87-103.
    • (2001) J Assoc Res Otolaryngol , vol.2 , pp. 87-103
    • Pfingst, B.E.1    Franck, K.H.2    Xu, L.3
  • 5
    • 0036279398 scopus 로고    scopus 로고
    • Speech recognition with the 24 SPEAK, ACE, and CIS speech coding strategies in newly implanted adults
    • Skinner MW, Holden LK, Whitford LA, et al. Speech recognition with the 24 SPEAK, ACE, and CIS speech coding strategies in newly implanted adults. Ear Hear 2002; 23: 207-223.
    • (2002) Ear Hear , vol.23 , pp. 207-223
    • Skinner, M.W.1    Holden, L.K.2    Whitford, L.A.3
  • 6
    • 0027503532 scopus 로고
    • Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
    • Shepherd RK, Hatsushika S, Clark GM., Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation. Hear Res 1993; 66: 108-120.
    • (1993) Hear Res , vol.66 , pp. 108-120
    • Shepherd, R.K.1    Hatsushika, S.2    Clark, G.M.3
  • 7
    • 0019482898 scopus 로고
    • Effect of site of stimulation on the guinea pigs electrically evoked brain stem response
    • Marsh RR, Yamane H, Potsic WP., Effect of site of stimulation on the guinea pigs electrically evoked brain stem response. Otolaryngol Head Neck Surg 1981; 89: 125-130.
    • (1981) Otolaryngol Head Neck Surg , vol.89 , pp. 125-130
    • Marsh, R.R.1    Yamane, H.2    Potsic, W.P.3
  • 8
    • 0026002712 scopus 로고
    • Cochlear implants: Histopathologic findings related to performance in 16 human temporal bones
    • Fayad J, Linthicum FH Jr,., Otto SR, et al. Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann Otol Rhinol Laryngol 1991; 100: 807-811.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 807-811
    • Fayad, J.1    Linthicum, Jr.F.H.2    Otto, S.R.3
  • 11
    • 0028267135 scopus 로고
    • Otopathology in a case of multichannel cochlear implantation
    • Nadol JB Jr,., Ketten DR, Burgess BJ., Otopathology in a case of multichannel cochlear implantation. Laryngoscope 1994; 104 (3 Pt 1): 299-303.
    • (1994) Laryngoscope , vol.104 , Issue.3 PART 1 , pp. 299-303
    • Nadol, Jr.J.B.1    Ketten, D.R.2    Burgess, B.J.3
  • 12
    • 0023121862 scopus 로고
    • Multichannel intracochlear electrodes: Mechanism of insertional trauma
    • Kennedy DW., Multichannel intracochlear electrodes: mechanism of insertional trauma. Laryngoscope 1987; 97: 42-49.
    • (1987) Laryngoscope , vol.97 , pp. 42-49
    • Kennedy, D.W.1
  • 13
    • 12344252040 scopus 로고    scopus 로고
    • Quality control after cochlear implant surgery by means of rotational tomography
    • Aschendorff A, Kubalek R, Turowski B, et al. Quality control after cochlear implant surgery by means of rotational tomography. Otol Neurotol 2005; 26: 34-37.
    • (2005) Otol Neurotol , vol.26 , pp. 34-37
    • Aschendorff, A.1    Kubalek, R.2    Turowski, B.3
  • 14
    • 59849092327 scopus 로고    scopus 로고
    • Role of electrode placement as a contributor to variability in cochlear implant outcomes
    • Finley CC, Holden TA, Holden LK, et al. Role of electrode placement as a contributor to variability in cochlear implant outcomes. Otol Neurotol 2008; 29: 920-928.
    • (2008) Otol Neurotol , vol.29 , pp. 920-928
    • Finley, C.C.1    Holden, T.A.2    Holden, L.K.3
  • 15
    • 34447310854 scopus 로고    scopus 로고
    • In vivo estimates of the position of Advanced Bionics electrode arrays in the human cochlea
    • Skinner MW, Holden TA, Whiting BR, et al. In vivo estimates of the position of Advanced Bionics electrode arrays in the human cochlea. Ann Otol Rhinol Laryngol 2007; 116 (Suppl 197): 1-24.
    • (2007) Ann Otol Rhinol Laryngol , vol.116 , Issue.SUPPL. 197 , pp. 1-24
    • Skinner, M.W.1    Holden, T.A.2    Whiting, B.R.3
  • 16
    • 34247640719 scopus 로고    scopus 로고
    • Quality control after insertion of the Nucleus Contour and Contour Advance electrode in adults
    • Aschendorff A, Kromeier J, Klenzer T, et al. Quality control after insertion of the Nucleus Contour and Contour Advance electrode in adults. Ear Hearing 2007; 28: 75S-79S.
    • (2007) Ear Hearing , vol.28
    • Aschendorff, A.1    Kromeier, J.2    Klenzer, T.3
  • 17
    • 1842729360 scopus 로고    scopus 로고
    • Effects of insertion depth of cochlear implant electrodes upon speech perception
    • Yukawa K, Cohen L, Blamey P, et al. Effects of insertion depth of cochlear implant electrodes upon speech perception. Audiol Neurotol 2004; 9: 163-172.
    • (2004) Audiol Neurotol , vol.9 , pp. 163-172
    • Yukawa, K.1    Cohen, L.2    Blamey, P.3
  • 18
    • 0030980713 scopus 로고    scopus 로고
    • Cochlear implant deep electrode insertion: Extent of insertional trauma
    • Gstoettner W, Plenk H Jr,., Franz P, et al. Cochlear implant deep electrode insertion: extent of insertional trauma. Acta Otolaryngol 1997; 117: 274-277.
    • (1997) Acta Otolaryngol , vol.117 , pp. 274-277
    • Gstoettner, W.1    Plenk, Jr.H.2    Franz, P.3
  • 19
    • 78349240921 scopus 로고    scopus 로고
    • . Factors predictive of open-set word recognition in adults with cochlear implants [poster presentation]. 2007 Conference on Implantable Auditory Prostheses. Lake Tahoe, CA
    • Skinner M, Holden LK, Holden TA, et al. Factors predictive of open-set word recognition in adults with cochlear implants [poster presentation]. 2007 Conference on Implantable Auditory Prostheses. Lake Tahoe, CA; 2007.
    • (2007)
    • Skinner, M.1    Holden, L.K.2    Holden, T.A.3
  • 20
    • 33846805945 scopus 로고    scopus 로고
    • Implications of deep electrode insertion on cochlear implant fitting
    • Gani M, Valentini G, Sigrist A, et al. Implications of deep electrode insertion on cochlear implant fitting. J Assoc Res Otolaryngol 2007; 8: 69-83.
    • (2007) J Assoc Res Otolaryngol , vol.8 , pp. 69-83
    • Gani, M.1    Valentini, G.2    Sigrist, A.3
  • 21
    • 0034093831 scopus 로고    scopus 로고
    • Electrode to modiolus proximity: A fluoroscopic and histologic analysis
    • Roland JT Jr,., Fishman AJ, Alexiades G, et al. Electrode to modiolus proximity: a fluoroscopic and histologic analysis. Am J Otol 2000; 21: 218-225.
    • (2000) Am J Otol , vol.21 , pp. 218-225
    • Roland, Jr.J.T.1    Fishman, A.J.2    Alexiades, G.3
  • 22
    • 23344447785 scopus 로고    scopus 로고
    • A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique
    • Roland JT Jr,. A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique. Laryngoscope 2005; 115: 1325-1339.
    • (2005) Laryngoscope , vol.115 , pp. 1325-1339
    • Roland, Jr.J.T.1
  • 23
    • 31344461075 scopus 로고    scopus 로고
    • Temporal bone microdissection for anatomic study of cochlear implant electrodes
    • Wright CG, Roland PS., Temporal bone microdissection for anatomic study of cochlear implant electrodes. Coch Imp Int 2005; 6: 159-168.
    • (2005) Coch Imp Int , vol.6 , pp. 159-168
    • Wright, C.G.1    Roland, P.S.2
  • 24
    • 33646512447 scopus 로고    scopus 로고
    • High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes
    • Postnov A, Zarowski A, De, Clerck N, et al. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes. Acta Otolaryngol 2006; 126: 467-474.
    • (2006) Acta Otolaryngol , vol.126 , pp. 467-474
    • Postnov, A.1    Zarowski, A.2    Clerck, N.3
  • 25
    • 36148983046 scopus 로고    scopus 로고
    • Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography
    • van, Wermeskerken GJ, Prokop M, van, Olphen AF, et al. Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography. Eur Arch Otorhinolaryngol 2007; 264: 1405-1407.
    • (2007) Eur Arch Otorhinolaryngol , vol.264 , pp. 1405-1407
    • Van1    Wermeskerken, G.J.2    Prokop, M.3    Van4    Olphen, A.F.5
  • 26
    • 30444456222 scopus 로고    scopus 로고
    • Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients
    • Verbist BM, Frijns JHM, Geleijns J, et al. Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients. Am J Neuroradiol 2005; 26: 424-429.
    • (2005) Am J Neuroradiol , vol.26 , pp. 424-429
    • Verbist, B.M.1    Frijns, J.H.M.2    Geleijns, J.3
  • 27
    • 2942703955 scopus 로고    scopus 로고
    • Imaging procedures in cochlear implant patients-evaluation of different radiological techniques
    • Aschendorff A, Kubalek R, Hochmuth A, et al. Imaging procedures in cochlear implant patients-evaluation of different radiological techniques. Acta Otolaryngol 2004; 552 (Suppl): 46-49.
    • (2004) Acta Otolaryngol , vol.552 , Issue.SUPPL. , pp. 46-49
    • Aschendorff, A.1    Kubalek, R.2    Hochmuth, A.3
  • 28
    • 56749151437 scopus 로고    scopus 로고
    • Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values
    • Noble JH, Warren FM, Labadie RF, et al. Automatic segmentation of the facial nerve and chorda tympani in CT images using spatially dependent feature values. Med Phys 2008; 35: 5375-5384.
    • (2008) Med Phys , vol.35 , pp. 5375-5384
    • Noble, J.H.1    Warren, F.M.2    Labadie, R.F.3
  • 30
    • 68249126001 scopus 로고    scopus 로고
    • Automatic identification and 3D rendering of temporal bone anatomy
    • Noble JH, Dawant BM, Warren FM, et al. Automatic identification and 3D rendering of temporal bone anatomy. Otol Neurotol 2009; 30: 436-442.
    • (2009) Otol Neurotol , vol.30 , pp. 436-442
    • Noble, J.H.1    Dawant, B.M.2    Warren, F.M.3
  • 31
    • 78349283812 scopus 로고    scopus 로고
    • Xoran Technologies website. Available at www.xorantech. com. Accessed April 11, 2010
    • Xoran Technologies website. Available at www.xorantech. com. Accessed April 11, 2010.
  • 32
    • 18144382323 scopus 로고    scopus 로고
    • Flux driven automatic centerline extraction
    • Bouix S, Siddiqi K, Tannenbaum A., Flux driven automatic centerline extraction. Med Image Anal 2009; 9: 209-221.
    • (2009) Med Image Anal , vol.9 , pp. 209-221
    • Bouix, S.1    Siddiqi, K.2    Tannenbaum, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.