메뉴 건너뛰기




Volumn 264, Issue 12, 2007, Pages 1405-1407

Intracochlear assessment of electrode position after cochlear implant surgery by means of multislice computer tomography

Author keywords

Cochlear implant; Computer tomography; Temporal bone

Indexed keywords

ARTICLE; CLINICAL ASSESSMENT; COCHLEA; COCHLEA PROSTHESIS; COMPUTER ASSISTED TOMOGRAPHY; ELECTRODE; HUMAN; PRIORITY JOURNAL; TEMPORAL BONE;

EID: 36148983046     PISSN: 09374477     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00405-007-0389-7     Document Type: Article
Times cited : (16)

References (18)
  • 3
    • 0027503532 scopus 로고
    • Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
    • Shepherd RK, Hatsushika S, Clark GM (1993) Electrical stimulation of the auditory nerve: the effect of electrode position on neural excitation. Hear Res 66:108-120
    • (1993) Hear Res , vol.66 , pp. 108-120
    • Shepherd, R.K.1    Hatsushika, S.2    Clark, G.M.3
  • 7
    • 3242718845 scopus 로고    scopus 로고
    • Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation
    • Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W (2004) Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Laryngoscope 114:237-241
    • (2004) Laryngoscope , vol.114 , pp. 237-241
    • Adunka, O.1    Kiefer, J.2    Unkelbach, M.H.3    Lehnert, T.4    Gstoettner, W.5
  • 8
    • 0033985953 scopus 로고    scopus 로고
    • Cochlear view: Postoperative radiography for cochlear implantation
    • Xu J, Xu SA, Cohen LT, Clark GM (2000) Cochlear view: postoperative radiography for cochlear implantation. Am J Otol 21:49-56
    • (2000) Am J Otol , vol.21 , pp. 49-56
    • Xu, J.1    Xu, S.A.2    Cohen, L.T.3    Clark, G.M.4
  • 11
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H (1999) Multi-slice helical CT: scan and reconstruction. Med Phys 26:5-18
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 16
    • 0035014013 scopus 로고    scopus 로고
    • Cochlear structures after implantation of a perimodiolar electrode array
    • Richter B, Jaekel K, Aschendorff A, Marangos N, Laszig R (2001) Cochlear structures after implantation of a perimodiolar electrode array. Laryngoscope 111:837-843
    • (2001) Laryngoscope , vol.111 , pp. 837-843
    • Richter, B.1    Jaekel, K.2    Aschendorff, A.3    Marangos, N.4    Laszig, R.5
  • 18
    • 23844552101 scopus 로고    scopus 로고
    • The human spiral ganglion: New insights into ultrastructure, survival rate and implications for cochlear implants
    • Glueckert R, Pfaller K, Kinnefors A, Rask-Andersen H, Schrott-Fischer A (2005) The human spiral ganglion: new insights into ultrastructure, survival rate and implications for cochlear implants. Audiol Neurootol 10:258-273
    • (2005) Audiol Neurootol , vol.10 , pp. 258-273
    • Glueckert, R.1    Pfaller, K.2    Kinnefors, A.3    Rask-Andersen, H.4    Schrott-Fischer, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.