메뉴 건너뛰기




Volumn 117, Issue 2, 1997, Pages 274-277

Cochlear implant deep electrode insertion: Extent of insertional trauma

Author keywords

auditory; Combi 40; electrostimulation; hearing nerve; human temporal bones

Indexed keywords

CADAVER; COCHLEA PROSTHESIS; CONFERENCE PAPER; ELECTRODE; HUMAN; HUMAN TISSUE; MICROSCOPY; PRIORITY JOURNAL; TEMPORAL BONE;

EID: 0030980713     PISSN: 00016489     EISSN: None     Source Type: Journal    
DOI: 10.3109/00016489709117786     Document Type: Conference Paper
Times cited : (92)

References (14)
  • 1
    • 0023121862 scopus 로고
    • Multichannel intrachochlear electrodes: Mechanism of insertion trauma
    • Kennedy DW. Multichannel intrachochlear electrodes: mechanism of insertion trauma, Laryngoscope 1987; 97: 42-9.
    • (1987) Laryngoscope , vol.97 , pp. 42-49
    • Kennedy, D.W.1
  • 2
    • 0027172357 scopus 로고
    • Insertional trauma of multichannel cochlear implants
    • Welling DB, Hinojosa R, Gantz BJ, Lee J. Insertional trauma of multichannel cochlear implants. Laryngoscope 1993; 103: 995-1001.
    • (1993) Laryngoscope , vol.103 , pp. 995-1001
    • Welling, D.B.1    Hinojosa, R.2    Gantz, B.J.3    Lee, J.4
  • 3
    • 0025056743 scopus 로고
    • Anatomical perspective, approach, and experience with multichannel intracochlear implantation
    • Goycoolea MV, Muchow DC, Schirber CM, Goycoolea HG, Schellhas K. Anatomical perspective, approach, and experience with multichannel intracochlear implantation. Laryngoscope 1990; 100: 1-18.
    • (1990) Laryngoscope , vol.100 , pp. 1-18
    • Goycoolea, M.V.1    Muchow, D.C.2    Schirber, C.M.3    Goycoolea, H.G.4    Schellhas, K.5
  • 6
    • 0028267135 scopus 로고
    • Otopathology in a case of multichannel cochlear implantation
    • Nadol JB, Ketten DR, Burgess BJ. Otopathology in a case of multichannel cochlear implantation. Laryngoscope 1994; 104: 299-303.
    • (1994) Laryngoscope , vol.104 , pp. 299-303
    • Nadol, J.B.1    Ketten, D.R.2    Burgess, B.J.3
  • 9
    • 0026002712 scopus 로고
    • Cochlear implants: Histopathologic findings related to performance in 16 human temporal bones
    • Fayad J, Linthicum FH, Otto SR, Galey FR, House WF. Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann Otol Rhinol Laryngol 1991; 100: 807-11.
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 807-811
    • Fayad, J.1    Linthicum, F.H.2    Otto, S.R.3    Galey, F.R.4    House, W.F.5
  • 10
    • 0026481346 scopus 로고
    • Temporal bone histopathology of a patient with a Nucleus 22-channel cochlear implant
    • Marsh MA, Coker NJ, Jenkins HA. Temporal bone histopathology of a patient with a Nucleus 22-channel cochlear implant. Am J Otol 1992; 13: 241-8.
    • (1992) Am J Otol , vol.13 , pp. 241-248
    • Marsh, M.A.1    Coker, N.J.2    Jenkins, H.A.3
  • 11
    • 0028961694 scopus 로고
    • Cochlear pathology following reimplantation of multichannel scala tympani electrode array in the macaque
    • Shepherd RK, Clark GM, Xu S, Pyman BC. Cochlear pathology following reimplantation of multichannel scala tympani electrode array in the macaque. Am J Otol 1995; 16: 186-99.
    • (1995) Am J Otol , vol.16 , pp. 186-199
    • Shepherd, R.K.1    Clark, G.M.2    Xu, S.3    Pyman, B.C.4
  • 12
    • 0002291192 scopus 로고
    • The microscopic evaluation of hard tissue implants
    • Williams DF, ed. Boca Raton, FL: CRC-Press
    • Plenk H. The microscopic evaluation of hard tissue implants. In: Williams DF, ed. Techniques of biocompatibility Testing. Vol. 1. Boca Raton, FL: CRC-Press, 1986: 35-81.
    • (1986) Techniques of Biocompatibility Testing , vol.1 , pp. 35-81
    • Plenk, H.1
  • 13
    • 0027712559 scopus 로고
    • Intracochlear electrode placement facilitated by Healon
    • Fraysse B, Deguine O, eds. Basel, Karger
    • Lenhardt E. Intracochlear electrode placement facilitated by Healon. In: Fraysse B, Deguine O, eds. Cochlear implants: new perspectives. Vol. 48. Basel, Karger, 1993: 62-4.
    • (1993) Cochlear Implants: New Perspectives , vol.48 , pp. 62-64
    • Lenhardt, E.1
  • 14
    • 0028951849 scopus 로고
    • Is deep insertion of the cochlear implant electrode array necessary and possible?
    • Donnely MJ, Cohen LT, Clark GM. Is deep insertion of the cochlear implant electrode array necessary and possible? Aust J Otolaryngol 1995; 1: 79-81.
    • (1995) Aust J Otolaryngol , vol.1 , pp. 79-81
    • Donnely, M.J.1    Cohen, L.T.2    Clark, G.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.