메뉴 건너뛰기




Volumn 51, Issue 10, 2010, Pages 1163-1171

Retrospective respiratory triggering renal perfusion MRI

Author keywords

Contrast enhanced; Function; Kidney; Respiratory motion

Indexed keywords

AVERAGE VALUES; BLOOD FLOW; CLINICAL ROUTINE; CONTRAST-ENHANCED; DCE-MRI; DYNAMIC CONTRAST ENHANCED MRI; FUNCTION PARAMETERS; KIDNEY; MEAN VALUES; PERFUSION MEASUREMENTS; PERFUSION MRI; PLASMA VOLUME; REGIONS OF INTEREST; RENAL FUNCTIONS; RESPIRATORY MOTIONS; STANDARD DEVIATION; TEMPORAL RESOLUTION; TRANSIT TIME;

EID: 78349274576     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.3109/02841851.2010.519717     Document Type: Article
Times cited : (16)

References (22)
  • 3
    • 0041343239 scopus 로고    scopus 로고
    • MR renography using a dynamic gradient-echo sequence and low-dose gadopentetate dimeglumine as an alternative to radionuclide renography
    • Teh HS, Ang ES, Wong WC, Tan SB, Tan AG, Chng SM, et al. MR renography using a dynamic gradient-echo sequence and low-dose gadopentetate dimeglumine as an alternative to radionuclide renography. Am J Roentgenol 2003;181:441-50.
    • (2003) Am. J. Roentgenol. , vol.181 , pp. 441-450
    • Teh, H.S.1    Ang, E.S.2    Wong, W.C.3    Tan, S.B.4    Tan, A.G.5    Chng, S.M.6
  • 4
    • 0030860299 scopus 로고    scopus 로고
    • Magnetic resonance renography: Optimisation of pulse sequence parameters and Gd-DTPA dose, and comparison with radionuclide renography
    • Taylor J, Summers PE, Keevil SF, Saks AM, Diskin J, Hilton PJ, et al. Magnetic resonance renography: optimisation of pulse sequence parameters and Gd-DTPA dose, and comparison with radionuclide renography. Magn Reson Imaging 1997;15:637-49.
    • (1997) Magn. Reson. Imaging , vol.15 , pp. 637-649
    • Taylor, J.1    Summers, P.E.2    Keevil, S.F.3    Saks, A.M.4    Diskin, J.5    Hilton, P.J.6
  • 5
    • 14044270785 scopus 로고    scopus 로고
    • Comparison of the hepatic perfusion index measured with gadolinium-enhanced volumetric MRI in controls and in patients with colorectal cancer
    • Totman JJ, O'Gorman RL, Kane PA, Karani JB. Comparison of the hepatic perfusion index measured with gadolinium-enhanced volumetric MRI in controls and in patients with colorectal cancer. Br J Radiol 2005;78:105-9.
    • (2005) Br. J. Radiol. , vol.78 , pp. 105-109
    • Totman, J.J.1    O'Gorman, R.L.2    Kane, P.A.3    Karani, J.B.4
  • 6
    • 34250377543 scopus 로고    scopus 로고
    • Quantitative determination of Gd-DTPA concentration in T1-weighted MR renography studies
    • Bokacheva L, Rusinek H, Chen Q, Oesingmann N, Prince C, Kaur M, et al. Quantitative determination of Gd-DTPA concentration in T1-weighted MR renography studies. Magn Reson Med 2007;57:1012-18.
    • (2007) Magn Reson Med. , vol.57 , pp. 1012-1018
    • Bokacheva, L.1    Rusinek, H.2    Chen, Q.3    Oesingmann, N.4    Prince, C.5    Kaur, M.6
  • 7
    • 26844539882 scopus 로고    scopus 로고
    • Quantification of renal perfusion and function on a voxel-by-voxel basis: A feasibility study
    • Dujardin M, Sourbron S, Luypaert R, Verbeelen D, Stadnik T. Quantification of renal perfusion and function on a voxel-by-voxel basis: a feasibility study. Magn Reson Med 2005;54:841-9.
    • (2005) Magn Reson Med. , vol.54 , pp. 841-849
    • Dujardin, M.1    Sourbron, S.2    Luypaert, R.3    Verbeelen, D.4    Stadnik, T.5
  • 8
    • 33750442900 scopus 로고    scopus 로고
    • Measurement of single kidney function using dynamic contrast-enhanced MRI: Comparison of two models in human subjects
    • Buckley DL, Shurrab AE, Cheung CM, Jones A P, Mamtora H, Kalra PA. Measurement of single kidney function using dynamic contrast-enhanced MRI: comparison of two models in human subjects. J Magn Reson Imaging 2006;24:1117-23.
    • (2006) J. Magn. Reson. Imaging , vol.24 , pp. 1117-1123
    • Buckley, D.L.1    Shurrab, A.E.2    Cheung, C.M.3    Jones, A.P.4    Mamtora, H.5    Kalra, P.A.6
  • 9
    • 24744450987 scopus 로고    scopus 로고
    • Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA
    • Hackstein N, Kooijman H, Tomaselli S, Rau WS. Glomerular filtration rate measured using the Patlak plot technique and contrast-enhanced dynamic MRI with different amounts of gadolinium-DTPA. J Magn Reson Imaging 2005;22:406-14.
    • (2005) J. Magn. Reson. Imaging , vol.22 , pp. 406-414
    • Hackstein, N.1    Kooijman, H.2    Tomaselli, S.3    Rau, W.S.4
  • 10
    • 0033653372 scopus 로고    scopus 로고
    • Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA
    • Vallee J P, Lazeyras F, Khan HG, Terrier F. Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA. Eur Radiol 2000;10:1245-52.
    • (2000) Eur. Radiol. , vol.10 , pp. 1245-1252
    • Vallee, J.P.1    Lazeyras, F.2    Khan, H.G.3    Terrier, F.4
  • 11
    • 33947125066 scopus 로고    scopus 로고
    • Dynamic magnetic resonance nephrography: Is saturation recovery TrueFISP advantageous over saturation recovery TurboFLASH?
    • Boss A, Martirosian P, Schaefer J F, Gehrmann M, Artimc F, Risler T, et al. Dynamic magnetic resonance nephrography: is saturation recovery TrueFISP advantageous over saturation recovery TurboFLASH? Invest Radiol 2007;42:256-62.
    • (2007) Invest. Radiol. , vol.42 , pp. 256-262
    • Boss, A.1    Martirosian, P.2    Schaefer, J.F.3    Gehrmann, M.4    Artimc, F.5    Risler, T.6
  • 14
    • 43449138208 scopus 로고    scopus 로고
    • Automatic alignment of renal DCE-MRI image series for improvement of quantitative tracer kinetic studies
    • San Diego, CA
    • Zikic D, Sourbron S P, Feng X, Michaely HJ, Khamene A, Navab N. Automatic alignment of renal DCE-MRI image series for improvement of quantitative tracer kinetic studies. In: SPIE Medical Imaging. San Diego, CA, 2008;91432.
    • (2008) SPIE Medical Imaging , pp. 91432
    • Zikic, D.1    Sourbron, S.P.2    Feng, X.3    Michaely, H.J.4    Khamene, A.5    Navab, N.6
  • 15
    • 31144435889 scopus 로고    scopus 로고
    • Renal artery stenosis: Functional assessment with dynamic MR perfusion measurements - Feasibility study
    • Michaely HJ, Schoenberg SO, Oesingmann N, Ittrich C, Buhlig C, Friedrich D, et al. Renal artery stenosis: functional assessment with dynamic MR perfusion measurements - feasibility study. Radiology 2006;238:586-96.
    • (2006) Radiology , vol.238 , pp. 586-596
    • Michaely, H.J.1    Schoenberg, S.O.2    Oesingmann, N.3    Ittrich, C.4    Buhlig, C.5    Friedrich, D.6
  • 16
    • 33847213864 scopus 로고    scopus 로고
    • Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements: A phase I trial
    • Boss A, Martirosian P, Gehrmann M, Artunc F, Risler T, Oesingmann N, et al. Quantitative assessment of glomerular filtration rate with MR gadolinium slope clearance measurements: a phase I trial. Radiology 2007;242:783-90.
    • (2007) Radiology , vol.242 , pp. 783-790
    • Boss, A.1    Martirosian, P.2    Gehrmann, M.3    Artunc, F.4    Risler, T.5    Oesingmann, N.6
  • 17
    • 37549034234 scopus 로고    scopus 로고
    • MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model
    • Sourbron S P, Michaely HJ, Reiser MF, Schoenberg SO. MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model. Invest Radiol 2008;43:40-8.
    • (2008) Invest. Radiol. , vol.43 , pp. 40-48
    • Sourbron, S.P.1    Michaely, H.J.2    Reiser, M.F.3    Schoenberg, S.O.4
  • 18
    • 20344388098 scopus 로고    scopus 로고
    • Contrast-invariant registration of cardiac and renal MR perfusion images
    • Medical Image Computing and Computer-Assisted Intervention, MICCAI 2004 - 7th International Conference, Proceedings
    • Sun Y, Jolly M-P, Moura JM. Contrast-invariant registration of cardiac and renal MR perfusion images. In: Proceedings of 7th Medical Image Computing and Computer Assisted Intervention, France; 2004. p. 903-10. (Pubitemid 40787466)
    • (2004) Lecture Notes in Computer Science , vol.3216 , Issue.PART 1 , pp. 903-910
    • Sun, Y.1    Jolly, M.-P.2    Moura, J.M.F.3
  • 22
    • 40949099048 scopus 로고    scopus 로고
    • Advanced liver fibrosis: Diagnosis with 3D whole-liver perfusion MR imaging - Initial experience
    • Hagiwara M, Rusinek H, Lee VS, Losada M, Bannan MA, Krinsky GA, et al. Advanced liver fibrosis: diagnosis with 3D whole-liver perfusion MR imaging - initial experience. Radiology 2008;246:926-34.
    • (2008) Radiology , vol.246 , pp. 926-934
    • Hagiwara, M.1    Rusinek, H.2    Lee, V.S.3    Losada, M.4    Bannan, M.A.5    Krinsky, G.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.