Volumn 60, Issue 1, 2010, Pages 109-116

Damping capacity assessment versus resonance frequency ananlysis in the determination of dental implant stability

Author keywords

Implant stability; Implant bone interface; Periotest; Resonance frequency analysis

Indexed keywords

ANALYTIC METHOD; ARTICLE; BONE DENSITY; DAMPING CAPACITY ASSESSMENT; DENTAL CARE; DENTAL HEALTH; DENTISTRY; HUMAN; INSTRUMENT VALIDATION; INTERMETHOD COMPARISON; MATERIALS TESTING; MOUTH EXAMINATION; NON INVASIVE MEASUREMENT; OSTEOLYSIS; PATIENT CARE; PRODUCT DEVELOPMENT; PROGNOSIS; PROSTHESIS FAILURE; QUANTITATIVE ANALYSIS; RESONANCE FREQUENCY ANALYSIS; RISK ASSESSMENT; TOOTH IMPLANTATION;

EID: 78349252027     PISSN: 15835251     EISSN: 1583526X     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (54)
  • 2
    • 33748309280 scopus 로고    scopus 로고
    • Validity and clinical signifcance of biomechanical testing of implant/bone interface
    • Aparicio C, Lang N P, Rangert B. Validity and clinical signifcance of biomechanical testing of implant/bone interface. Clin Oral Imp Res 2006;17(Suppl. 2):2-7.
    • (2006) Clin Oral Imp Res , vol.17 , Issue.SUPPL. 2 , pp. 2-7
    • Aparicio, C.1    Lang, N.P.2    Rangert, B.3
  • 3
    • 47249142397 scopus 로고    scopus 로고
    • Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial
    • Zix J, Hug S, Kessler-Liechtl G, et al. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants 2008;23:525-30.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 525-530
    • Zix, J.1    Hug, S.2    Kessler-Liechtl, G.3
  • 4
    • 33645051957 scopus 로고    scopus 로고
    • Resonance frequency analysis and dampening capacity assessment. Part 2: Peri-implant bone loss follow-up
    • Lachmann S, Jager B, Axmann D, et al. Resonance frequency analysis and dampening capacity assessment. Part 2: peri-implant bone loss follow-up. Clin Oral Implants Res 2006;17:80-84.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 80-84
    • Lachmann, S.1    Jager, B.2    Axmann, D.3
  • 5
    • 33645084797 scopus 로고    scopus 로고
    • Resonance frequency analysis and dampening capacity assessment. Part 1: An in vitro study on measurement reliability and a method of comparison in the determination of primary implant stability
    • Lachmann S, Jager B, Axmann D, et al. Resonance frequency analysis and dampening capacity assessment. Part 1: an in vitro study on measurement reliability and a method of comparison in the determination of primary implant stability. Clin Oral Implants Research 2006;17:75-79.
    • (2006) Clin Oral Implants Research , vol.17 , pp. 75-79
    • Lachmann, S.1    Jager, B.2    Axmann, D.3
  • 6
    • 33748334188 scopus 로고    scopus 로고
    • Push-out (pull-out), tensile, and reverse-torque tests of bone-implant interfaces
    • in press
    • Brunski J. Push-out (pull-out), tensile, and reverse-torque tests of bone-implant interfaces. Clin Oral Implants Research 2006;17:in press.
    • (2006) Clin Oral Implants Research , pp. 17
    • Brunski, J.1
  • 8
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal RM, Oates T W, Meredith N, et al. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral & Maxillofac Implants 2003;18:641-51.
    • (2003) Int J Oral & Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.M.1    Oates, T.W.2    Meredith, N.3
  • 10
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-7.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 11
    • 33847790159 scopus 로고    scopus 로고
    • Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial
    • Valderrama P, Oates T W, Jones AA, et al. Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. J Periodontol 2007;78:262-72.
    • (2007) J Periodontol , vol.78 , pp. 262-272
    • Valderrama, P.1    Oates, T.W.2    Jones, A.A.3
  • 12
    • 0020768715 scopus 로고
    • Periotest - a new measurement process for periodontal function
    • 1233-6,1239-40
    • Schulte W, d'Hoedt B, Lukas D, et al. Periotest - a new measurement process for periodontal function. Zahnärztliche Mitteilungen 1983;73:1229-1230,1233-6,1239-40.
    • (1983) Zahnärztliche Mitteilungen , vol.73 , pp. 1229-1230
    • Schulte, W.1    D'hoedt, B.2    Lukas, D.3
  • 13
    • 0027434751 scopus 로고
    • Periotest to monitor osseointegration and to check the occlusion in oral implantology
    • Schulte W, Lukas D. Periotest to monitor osseointegration and to check the occlusion in oral implantology. J Oral Implant 1993;19:23-32.
    • (1993) J Oral Implant , vol.19 , pp. 23-32
    • Schulte, W.1    Lukas, D.2
  • 14
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, et al. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral and Maxillofac Surg 1999;28:297-303.
    • (1999) Int J Oral and Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3
  • 15
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, et al. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study. Clinic Implant Dent & Related Res 2002;4:128-132.
    • (2002) Clinic Implant Dent & Related Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3
  • 16
    • 7944232457 scopus 로고    scopus 로고
    • Implant stability measurement of delayed and immediately loaded implants during healing
    • Bischof M, Nedir R, Szmukler-Moncler S, et al. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 2004;15:529-539.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 529-539
    • Bischof, M.1    Nedir, R.2    Szmukler-Moncler, S.3
  • 17
    • 25444498330 scopus 로고    scopus 로고
    • A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants
    • Balshi SF, Allen FD, Wolfnger GJ, et al. A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral & Maxillofac Implants 2005;20:584-594.
    • (2005) Int J Oral & Maxillofac Implants , vol.20 , pp. 584-594
    • Balshi, S.F.1    Allen, F.D.2    Wolfnger, G.J.3
  • 18
    • 18744390029 scopus 로고    scopus 로고
    • Implant stability measurements for implants placed at the time of extraction: A cohort, prospective clinical trial
    • Becker W, Sennerby L, Bedrossian E, et al. Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial. J Perio 2005;76:391-397.
    • (2005) J Perio , vol.76 , pp. 391-397
    • Becker, W.1    Sennerby, L.2    Bedrossian, E.3
  • 19
    • 32644446492 scopus 로고    scopus 로고
    • Resonance frequency analysis measurements of implants at placement surgery
    • Östman PO, Hellman M, Wendelhag I, et al. Resonance frequency analysis measurements of implants at placement surgery. Int J Prosth 2006;19:77-83.
    • (2006) Int J Prosth , vol.19 , pp. 77-83
    • Östman, P.O.1    Hellman, M.2    Wendelhag, I.3
  • 20
    • 27544491195 scopus 로고    scopus 로고
    • Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: A pilot study
    • Zix J, Kessler-Liechti G, Mericske-Stern R. Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral & Maxillofac Implants 2005;20:747-752.
    • (2005) Int J Oral & Maxillofac Implants , vol.20 , pp. 747-752
    • Zix, J.1    Kessler-Liechti, G.2    Mericske-Stern, R.3
  • 21
    • 0041511713 scopus 로고    scopus 로고
    • Early loading of maxillary fxed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after 1 year of loading, case series
    • Olsson M, Urde G, Andersen JB, et al. Early loading of maxillary fxed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series. Clin Implant Dent & Related Res 2003;5(Suppl. 1):81-87.
    • (2003) Clin Implant Dent & Related Res , vol.5 , Issue.1 , pp. 81-87
    • Olsson, M.1    Urde, G.2    Andersen, J.B.3
  • 22
    • 7944234226 scopus 로고    scopus 로고
    • Predicting osseointegration by means of implant primary stability
    • Nedir R, Bischof M, Szmukler-Moncler S, et al. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 2004;15:520-8.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 520-528
    • Nedir, R.1    Bischof, M.2    Szmukler-Moncler, S.3
  • 23
    • 11844280921 scopus 로고    scopus 로고
    • Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading
    • Sjöström M, Lundgren S, Nilson H, et al. Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading. Int J Oral & Maxillofac Surg 2005;34:45-51.
    • (2005) Int J Oral & Maxillofac Surg , vol.34 , pp. 45-51
    • Sjöström, M.1    Lundgren, S.2    Nilson, H.3
  • 24
    • 34547217298 scopus 로고    scopus 로고
    • Resonance Frequency Analysis (RFA) in relation to jaw bone characteristics during early healing
    • Huwiler M, Pjeturson BE, Bosshardt DD, et al. Resonance Frequency Analysis (RFA) in relation to jaw bone characteristics during early healing. Clinical Oral Implants Rese 2007;18:275-280.
    • (2007) Clinical Oral Implants Rese , vol.18 , pp. 275-280
    • Huwiler, M.1    Pjeturson, B.E.2    Bosshardt, D.D.3
  • 25
    • 33748314334 scopus 로고    scopus 로고
    • Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures. A one-year randomized prospective study comparing early and conventional loading protocols
    • Turkyilmaz I, Sennerby L, Tumer C, et al. Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures. A one-year randomized prospective study comparing early and conventional loading protocols. Clin Oral Implants Res 2006;17:501-5.
    • (2006) Clin Oral Implants Res , vol.17 , pp. 501-505
    • Turkyilmaz, I.1    Sennerby, L.2    Tumer, C.3
  • 26
    • 0026125001 scopus 로고
    • Periotest: An objective clinical diagnosis of bone apposition toward implants
    • Teerlinck J, Quirynen M, Darius P, et al. Periotest: an objective clinical diagnosis of bone apposition toward implants. Int J Oral & Maxillofac Implants 1991;6:55-61.
    • (1991) Int J Oral & Maxillofac Implants , vol.6 , pp. 55-61
    • Teerlinck, J.1    Quirynen, M.2    Darius, P.3
  • 27
    • 85081703526 scopus 로고
    • An evaluation of the Periotest system. Part I: Examiner reliability and repeatability of readings
    • Manz MC, Morris HF, Ochi S. An evaluation of the Periotest system. Part I: examiner reliability and repeatability of readings. Implant Dent 1992;1:142-146.
    • (1992) Implant Dent , vol.1 , pp. 142-146
    • Manz, M.C.1    Morris, H.F.2    Ochi, S.3
  • 28
    • 0026919676 scopus 로고
    • An evaluation of the Periotest system. Part II: Reliability and repeatability of instruments
    • Manz MC, Morris HF, Ochi S. An evaluation of the Periotest system. Part II: reliability and repeatability of instruments. Implant Dent 1992;1:221-226.
    • (1992) Implant Dent , vol.1 , pp. 221-226
    • Manz, M.C.1    Morris, H.F.2    Ochi, S.3
  • 29
    • 0027563234 scopus 로고
    • In vitro consistency of the Periotest instrument
    • Chai JY, Yamada J, Pang IC. In vitro consistency of the Periotest instrument. J Prosth 1993;2:9-12.
    • (1993) J Prosth , vol.2 , pp. 9-12
    • Chai, J.Y.1    Yamada, J.2    Pang, I.C.3
  • 30
    • 0029266570 scopus 로고
    • Assessment of the Periotest device in baseline mobility measurements of craniofacial implants
    • Derhami K, Wolfaardt JF, Faulkner G, et al. Assessment of the Periotest device in baseline mobility measurements of craniofacial implants. Int J Oral & Maxillofac Implants 1995;10:221-229.
    • (1995) Int J Oral & Maxillofac Implants , vol.10 , pp. 221-229
    • Derhami, K.1    Wolfaardt, J.F.2    Faulkner, G.3
  • 31
    • 0032458301 scopus 로고    scopus 로고
    • A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants
    • Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Critical Reviews in Biomedical Engineering 1998;26:275-291.
    • (1998) Critical Reviews In Biomedical Engineering , vol.26 , pp. 275-291
    • Meredith, N.1
  • 32
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosth 1998;11:491-501.
    • (1998) Int J Prosth , vol.11 , pp. 491-501
    • Meredith, N.1
  • 33
    • 0032059195 scopus 로고    scopus 로고
    • Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability
    • Meredith N, Friberg B, Sennerby L, et al. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosth 1998;11:269-75.
    • (1998) Int J Prosth , vol.11 , pp. 269-275
    • Meredith, N.1    Friberg, B.2    Sennerby, L.3
  • 34
    • 0032617540 scopus 로고    scopus 로고
    • Experimental study of the damping behaviour of IMZ implants
    • Haas R, Bernhart T, Dortbudak O, et al. Experimental study of the damping behaviour of IMZ implants. J Oral Rehabilit 1999;26:19-24.
    • (1999) J Oral Rehabilit , vol.26 , pp. 19-24
    • Haas, R.1    Bernhart, T.2    Dortbudak, O.3
  • 36
    • 0025654203 scopus 로고
    • Periotest method as a measure of osseointegrated oral implant stability
    • Olivé J, Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral & Maxillofac Implants 1990;5:390-400.
    • (1990) Int J Oral & Maxillofac Implants , vol.5 , pp. 390-400
    • Olivé, J.1    Aparicio, C.2
  • 37
    • 0029174071 scopus 로고
    • Mechanical state assessment of the implant-bone continuum: A better understanding of the Periotest method
    • Tricio J, Laohapand P, van Steenberghe D, et al. Mechanical state assessment of the implant-bone continuum: a better understanding of the Periotest method. Int J Oral & Maxillofac Implants 1995;10:43-49.
    • (1995) Int J Oral & Maxillofac Implants , vol.10 , pp. 43-49
    • Tricio, J.1    Laohapand, P.2    van Steenberghe, D.3
  • 38
    • 0029446141 scopus 로고
    • Implant stability related to insertion torque force and bone density: An in vitro study
    • Tricio J, van Steenberghe D, Rosenberg D, et al. Implant stability related to insertion torque force and bone density: an in vitro study. J Prost Dent 1995;74:608-612.
    • (1995) J Prost Dent , vol.74 , pp. 608-612
    • Tricio, J.1    van Steenberghe, D.2    Rosenberg, D.3
  • 39
    • 0025622922 scopus 로고
    • Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants
    • Buser D, Weber HP, Lang NP. Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. Clin Oral Implants Res 1990;1:33-40.
    • (1990) Clin Oral Implants Res , vol.1 , pp. 33-40
    • Buser, D.1    Weber, H.P.2    Lang, N.P.3
  • 40
    • 0029264675 scopus 로고
    • Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device
    • van Steenberghe D, Tricio J, Naert I, et al. Damping characteristics of bone-to-implant interfaces. A clinical study with the Periotest device. Clin Oral Implants Res 1995;6:31-39.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 31-39
    • van Steenberghe, D.1    Tricio, J.2    Naert, I.3
  • 42
    • 0030734057 scopus 로고    scopus 로고
    • The infuence of bone quality on Periotest values of endosseous dental implants at stage II surgery
    • Truhlar RS, Lauciello F, Morris HF, et al. The infuence of bone quality on Periotest values of endosseous dental implants at stage II surgery. Journal of Oral and Maxillofacial Surgery 1997;55(Suppl. 5):55-61.
    • (1997) Journal of Oral and Maxillofacial Surgery , vol.55 , Issue.5 , pp. 55-61
    • Truhlar, R.S.1    Lauciello, F.2    Morris, H.F.3
  • 43
    • 0034584296 scopus 로고    scopus 로고
    • Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the Periotest device on endosseous dental implants
    • Truhlar RS, Morris HF, Ochi S. Stability of the bone-implant complex. Results of longitudinal testing to 60 months with the Periotest device on endosseous dental implants. Annals/Journal of Periodontology 2000;5:42-55.
    • (2000) Annals/Journal of Periodontology , vol.5 , pp. 42-55
    • Truhlar, R.S.1    Morris, H.F.2    Ochi, S.3
  • 44
    • 0029314564 scopus 로고
    • Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study
    • Mericske-Stern R, Milani D, Mericske E, et al. Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. A one-year longitudinal study. Clinical Oral Implants Research 1995;6:73-82.
    • (1995) Clinical Oral Implants Research , vol.6 , pp. 73-82
    • Mericske-Stern, R.1    Milani, D.2    Mericske, E.3
  • 46
    • 0031132982 scopus 로고    scopus 로고
    • The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: An experimental animal study
    • Caulier H, Naert I, Kalk W, et al. The relationship of some histologic parameters, radiographic evaluations, and Periotest measurements of oral implants: an experimental animal study. International Journal of Oral & Maxillofacial Implants 1997;12:380-386.
    • (1997) International Journal of Oral & Maxillofacial Implants , vol.12 , pp. 380-386
    • Caulier, H.1    Naert, I.2    Kalk, W.3
  • 47
    • 0032060817 scopus 로고    scopus 로고
    • Mobility assessment with the Periotest system in relation to histologic fndings of oral implants
    • Isidor F. Mobility assessment with the Periotest system in relation to histologic fndings of oral implants. International Journal of Oral & Maxillofacial Implants 1998;13:377-383.
    • (1998) International Journal of Oral & Maxillofacial Implants , vol.13 , pp. 377-383
    • Isidor, F.1
  • 49
    • 7244260317 scopus 로고    scopus 로고
    • A 10-year randomized clinical trial on the infuence of splinted and unsplinted oral implants retaining mandibular overdentures: Peri-implant outcome
    • Naert I, Alsaadi G, van Steenberghe D, et al. A 10-year randomized clinical trial on the infuence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome. International Journal of Oral & Maxillofacial Implants 2004;19:695-702.
    • (2004) International Journal of Oral & Maxillofacial Implants , vol.19 , pp. 695-702
    • Naert, I.1    Alsaadi, G.2    van Steenberghe, D.3
  • 50
    • 0035749825 scopus 로고    scopus 로고
    • One-stage operative procedure using two different implant systems: A prospective study on implant overdentures in the edentulous mandible
    • Tawse-Smith A, Perio C, Payne AG, et al. One-stage operative procedure using two different implant systems: a prospective study on implant overdentures in the edentulous mandible. Clinical Implant Dentistry & Related Research 2001;3:185-193.
    • (2001) Clinical Implant Dentistry & Related Research , vol.3 , pp. 185-193
    • Tawse-Smith, A.1    Perio, C.2    Payne, A.G.3
  • 51
    • 4644241352 scopus 로고    scopus 로고
    • Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog
    • Abrahamsson I, Berglundh T, Linder E, et al. Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clinical Oral Implants Research 2004;15:381-392.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 381-392
    • Abrahamsson, I.1    Berglundh, T.2    Linder, E.3
  • 53
    • 0034185829 scopus 로고    scopus 로고
    • A prospective study to assess osseointegration of dental endosseous implants with the Periotest instrument
    • Drago CJ. A prospective study to assess osseointegration of dental endosseous implants with the Periotest instrument. International Journal of Oral & Maxillofacial Implants 2000;15:389-395.
    • (2000) International Journal of Oral & Maxillofacial Implants , vol.15 , pp. 389-395
    • Drago, C.J.1
  • 54
    • 0034154772 scopus 로고    scopus 로고
    • Reliability of some clinical parameters of evaluation in implant dentistry
    • Verhoeven J W, Cune MS, de Putter C. Reliability of some clinical parameters of evaluation in implant dentistry. Journal of Oral Rehabilitation 2000;27:211-216.
    • (2000) Journal of Oral Rehabilitation , vol.27 , pp. 211-216
    • Verhoeven, J.W.1    Cune, M.S.2    de Putter, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.