메뉴 건너뛰기




Volumn 34, Issue 1, 2005, Pages 45-51

Monitoring of implant stability in grafted bone using resonance frequency analysis A clinical study from implant placement to 6 months of loading

Author keywords

Autogenous bone graft; Edentulous atrophic maxilla; Implant stability; Resonance frequency analysis

Indexed keywords

ADULT; AGED; ARTICLE; BONE GRAFT; CLINICAL ARTICLE; CLINICAL STUDY; CONTROLLED STUDY; DEVICE; EDENTULOUSNESS; FEMALE; FREQUENCY ANALYSIS; HUMAN; IMPLANT; MALE; MAXILLA; MAXILLA OSTEOTOMY; MAXILLOFACIAL SURGERY; MOLECULAR STABILITY; PROSPECTIVE STUDY; RANK SUM TEST; SURGICAL TECHNIQUE; TIME; WILCOXON SIGNED RANKS TEST;

EID: 11844280921     PISSN: 09015027     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijom.2004.03.007     Document Type: Article
Times cited : (77)

References (40)
  • 1
    • 0025490055 scopus 로고
    • Reconstruction of severely edentolous maxillae using osseointegrated fixtures in immediate autogenous bone grafts
    • R. Adell Lekholm U. Gröndahl K. Reconstruction of severely edentolous maxillae using osseointegrated fixtures in immediate autogenous bone grafts Int. J. Oral Maxillofac. Implants 5 1990 233-246
    • (1990) Int. J. Oral Maxillofac. Implants , vol.5 , pp. 233-246
    • Adell, R.1    Lekholm, U.2    Gröndahl, K.3
  • 3
    • 0030740907 scopus 로고    scopus 로고
    • Sinus inlay bone augmentation: Comparison of implant positioning after one- or two-staged procedures
    • Blomqvist J.E. Alberius P. Isaksson S. Sinus inlay bone augmentation: comparison of implant positioning after one- or two-staged procedures J. Oral Maxillofac. Surg. 55 1997 804-810
    • (1997) J. Oral Maxillofac. Surg. , vol.55 , pp. 804-810
    • Blomqvist, J.E.1    Alberius, P.2    Isaksson, S.3
  • 4
    • 0018841874 scopus 로고
    • Reconstruction of alveolar jaw bone. An experimental and clinical study of immediate and preformed autologous bone grafts in combination with osseointegrated implants
    • U. Breine Brånemark P.-I. Reconstruction of alveolar jaw bone. An experimental and clinical study of immediate and preformed autologous bone grafts in combination with osseointegrated implants Scand J. Plast. Reconstr. Surg. 14 1980 23-48
    • (1980) Scand J. Plast. Reconstr. Surg. , vol.14 , pp. 23-48
    • Breine, U.1    Brånemark, P.-I.2
  • 7
    • 0032088918 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants. II. Etiopathogenesis
    • Esposito M. Hirsh J.-M. Lekholm U. Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. II. Etiopathogenesis Eur. J. Oral Sci. 106 1998 721-764
    • (1998) Eur. J. Oral Sci. , vol.106 , pp. 721-764
    • Esposito, M.1    Hirsh, J.-M.2    Lekholm, U.3    Thomsen, P.4
  • 8
    • 0033169238 scopus 로고    scopus 로고
    • Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency study
    • Friberg B. Sennerby L. Lindén B. Gröndahl K. Lekholm U. Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency study Int. J. Oral Maxillofac. Surg. 28 1999 266-272
    • (1999) Int. J. Oral Maxillofac. Surg. , vol.28 , pp. 266-272
    • Friberg, B.1    Sennerby, L.2    Lindén, B.3    Gröndahl, K.4    Lekholm, U.5
  • 9
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B. Sennerby L. Meredith N. Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study Int. J. Oral Maxillofac. Surg. 28 1999 297-303
    • (1999) Int. J. Oral Maxillofac. Surg. , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 10
    • 0348234956 scopus 로고    scopus 로고
    • On Bone Quality and Implant Stability Measurements
    • Thesis, University of Gothenburg, Sweden
    • Friberg B. On Bone Quality and Implant Stability Measurements. Thesis, University of Gothenburg, Sweden 1999
    • (1999)
    • Friberg, B.1
  • 12
    • 0027244789 scopus 로고
    • On cutting torque measurements during implant placement: A 3-year clinical prospective study
    • S. Isaksson Ekfeldt A. Alberius P. Blomqvist J.-E. Early results from reconstruction of severely atrophic (class VI) maxillas by immediate endosseous implants in conjunction with bone grafting and Le Fort I osteotomy Int. J. Oral Maxillofac. Surg. 22 1993 144-148
    • (1993) Int. J. Oral Maxillofac. Surg. , vol.22 , pp. 144-148
    • Isaksson, S.1    Ekfeldt, A.2    Alberius, P.3    Blomqvist, J.-E.4
  • 13
    • 0141658628 scopus 로고    scopus 로고
    • On Surgical and Implant Related Factors Influencing Integration and Function of Titanium Implants
    • Thesis, University of Göteborg, Sweden
    • Ivanoff C-J. On Surgical and Implant Related Factors Influencing Integration and Function of Titanium Implants. Thesis, University of Göteborg, Sweden 1999
    • (1999)
    • Ivanoff, C.-J.1
  • 14
    • 0029303074 scopus 로고
    • Implant treatment in edentolous maxillae: A 5-year follow-up report on patients with different degrees of jaw resorption
    • Jemt T. Lekholm U. Implant treatment in edentolous maxillae: a 5-year follow-up report on patients with different degrees of jaw resorption Int. J. Oral Maxillofac. Implants 10 1995 303-310
    • (1995) Int. J. Oral Maxillofac. Implants , vol.10 , pp. 303-310
    • Jemt, T.1    Lekholm, U.2
  • 15
    • 0025986556 scopus 로고
    • Autogenous mandibular bone grafts and osseointegrated implants for reconstruction of the severely atrophied maxilla: A preliminary report
    • Jensen J. Sindet-Pedersen S. Autogenous mandibular bone grafts and osseointegrated implants for reconstruction of the severely atrophied maxilla: A preliminary report J. Oral Maxillofac. Surg. 49 1991 1277-1287
    • (1991) J. Oral Maxillofac. Surg. , vol.49 , pp. 1277-1287
    • Jensen, J.1    Sindet-Pedersen, S.2
  • 17
    • 0032112663 scopus 로고    scopus 로고
    • Histologic analysis of clinically retrieved titanium microimplants placed in conjunction with maxillary sinus floor augmentation
    • Jensen Ole T. Sennerby L. Histologic analysis of clinically retrieved titanium microimplants placed in conjunction with maxillary sinus floor augmentation Int. J. Oral Maxillofac. Implants 13 1998 513-521
    • (1998) Int. J. Oral Maxillofac. Implants , vol.13 , pp. 513-521
    • Jensen Ole, T.1    Sennerby, L.2
  • 18
    • 0024782189 scopus 로고
    • Combined use of bone grafts and Brånemark fixtures in the treatment of severely resorbed maxillae
    • Kahnberg K.-E. Nyström E. Bartholdsson L. Combined use of bone grafts and Brånemark fixtures in the treatment of severely resorbed maxillae Int. J. Oral Maxillofac. Implants 4 1989 297-304
    • (1989) Int. J. Oral Maxillofac. Implants , vol.4 , pp. 297-304
    • Kahnberg, K.-E.1    Nyström, E.2    Bartholdsson, L.3
  • 19
    • 0033160778 scopus 로고    scopus 로고
    • Le Fort I osteotomy with interpositional bone grafts and implants for rehabilitation of the severely resorbed maxilla: A 2-stage procedure
    • Kahnberg K.E. Nilsson P. Rasmusson L. Le Fort I osteotomy with interpositional bone grafts and implants for rehabilitation of the severely resorbed maxilla: A 2-stage procedure Int. J. Maxillofac. Implants 14 1999 571-578
    • (1999) Int. J. Maxillofac. Implants , vol.14 , pp. 571-578
    • Kahnberg, K.E.1    Nilsson, P.2    Rasmusson, L.3
  • 20
    • 0029401652 scopus 로고
    • A modified method of simultaneous bone grafting and placement of endosseous implants in the severely atrophic maxilla
    • Krekmanov L. A modified method of simultaneous bone grafting and placement of endosseous implants in the severely atrophic maxilla Int. J. Oral Maxillofac. Implants 10 1995 682-688
    • (1995) Int. J. Oral Maxillofac. Implants , vol.10 , pp. 682-688
    • Krekmanov, L.1
  • 22
    • 0033137313 scopus 로고    scopus 로고
    • Oral implants in combination with bone grafts. A 3-year retrospective multicenter study using the Brånemark implant system
    • Lekholm U. Wannfors K. Isaksson S. Adielsson B. Oral implants in combination with bone grafts. A 3-year retrospective multicenter study using the Brånemark implant system Int. J. Oral Maxillofac. Surg. 28 1999 181-187
    • (1999) Int. J. Oral Maxillofac. Surg. , vol.28 , pp. 181-187
    • Lekholm, U.1    Wannfors, K.2    Isaksson, S.3    Adielsson, B.4
  • 23
    • 0031308227 scopus 로고    scopus 로고
    • Bone grafting to the maxillary sinuses, nasal floor and anterior maxilla in the atrophic edentulous maxilla. A two-stage technique
    • Lundgren S. Nyström E. Nilson H. Gunne J. Lindhagen O. Bone grafting to the maxillary sinuses, nasal floor and anterior maxilla in the atrophic edentulous maxilla. A two-stage technique Int. J. Oral Maxillofac. Surg. 26 1997 428-434
    • (1997) Int. J. Oral Maxillofac. Surg. , vol.26 , pp. 428-434
    • Lundgren, S.1    Nyström, E.2    Nilson, H.3    Gunne, J.4    Lindhagen, O.5
  • 25
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N. Alleyne D. Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis Clin. Oral Implant Res. 7 1996 261-267
    • (1996) Clin. Oral Implant Res. , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 26
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentolous and partially dentate maxilla
    • Meredith N. Book K. Friberg B. Jemt T. Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentolous and partially dentate maxilla Clin. Oral Implant Res. 8 1997 226-233
    • (1997) Clin. Oral Implant Res. , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 27
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant Int. J. Prosthodont. 11 1998 491-501
    • (1998) Int. J. Prosthodont. , vol.11 , pp. 491-501
    • Meredith, N.1
  • 28
    • 0030988001 scopus 로고    scopus 로고
    • Osseointegration of dental implants in rabbit bone with low mineral density
    • Mori H. Manabe M. Kurachi Y. Nagumo M. Osseointegration of dental implants in rabbit bone with low mineral density J. Oral Maxillofac. Surg. 55 1997 351-361
    • (1997) J. Oral Maxillofac. Surg. , vol.55 , pp. 351-361
    • Mori, H.1    Manabe, M.2    Kurachi, Y.3    Nagumo, M.4
  • 29
    • 0033197090 scopus 로고    scopus 로고
    • Long-term results after placement of dental implants: Longitudinal study of 1,964 implants over 16 years
    • Noack N. Willer J. Hoffman J. Long-term results after placement of dental implants: Longitudinal study of 1,964 implants over 16 years Int. J. Oral Maxillofac. Implants 14 1999 748-755
    • (1999) Int. J. Oral Maxillofac. Implants , vol.14 , pp. 748-755
    • Noack, N.1    Willer, J.2    Hoffman, J.3
  • 30
    • 0027350919 scopus 로고
    • Bone grafts and Brånemark implants in the treatment of the severely resorbed maxilla: A 2-year longitudinal study
    • Nyström E. Kahnberg K.E. Gunne J. Bone grafts and Brånemark implants in the treatment of the severely resorbed maxilla: a 2-year longitudinal study Int. J. Oral Maxillofac. Implants 8 1993 45-53
    • (1993) Int. J. Oral Maxillofac. Implants , vol.8 , pp. 45-53
    • Nyström, E.1    Kahnberg, K.E.2    Gunne, J.3
  • 31
    • 0031300167 scopus 로고    scopus 로고
    • Interpositional bone grafting and Le Fort I osteotomy for reconstruction of the atrophic edentolous maxilla. A two-stage technique
    • Nyström E. Lundgren S. Gunne J. Nilson H. Interpositional bone grafting and Le Fort I osteotomy for reconstruction of the atrophic edentolous maxilla. A two-stage technique Int. J. Oral Maxillofac. Surg. 26 1997 423-427
    • (1997) Int. J. Oral Maxillofac. Surg. , vol.26 , pp. 423-427
    • Nyström, E.1    Lundgren, S.2    Gunne, J.3    Nilson, H.4
  • 32
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: A human cadaver study
    • O'Sullivan D. Sennerby L. Meredith N. Measurements comparing the initial stability of five designs of dental implants: A human cadaver study Clin. Implant Dent. Relat. Res. 2 2000 85-92
    • (2000) Clin. Implant Dent. Relat. Res. , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 33
    • 0033145562 scopus 로고    scopus 로고
    • The influence of simultaneous vs. delayed placement on the stability of titanium implants in onlay bone grafts. A histologic and biomechanic study in the rabbit
    • Rasmusson L. Meredith N. Cho I.H. Sennerby L. The influence of simultaneous vs. delayed placement on the stability of titanium implants in onlay bone grafts. A histologic and biomechanic study in the rabbit Int. J. Oral Maxillofac. Surg. 28 1999 224-231
    • (1999) Int. J. Oral Maxillofac. Surg. , vol.28 , pp. 224-231
    • Rasmusson, L.1    Meredith, N.2    Cho, I.H.3    Sennerby, L.4
  • 34
    • 0033302106 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis in the grafted maxilla: A cross-sectional pilot study
    • Rasmusson L. Stegersjö G. Sennerby L. Implant stability measurements using resonance frequency analysis in the grafted maxilla: A cross-sectional pilot study Clin. Implant Dent. Relat. Res. 2 1999 70-74
    • (1999) Clin. Implant Dent. Relat. Res. , vol.2 , pp. 70-74
    • Rasmusson, L.1    Stegersjö, G.2    Sennerby, L.3
  • 35
    • 0030694836 scopus 로고    scopus 로고
    • Survival analysis of endosseous implants in bone grafts used for the treatment of severe alveolar ridge atrophy
    • Schliephake H. Neukam F.W. Wichmann M. Survival analysis of endosseous implants in bone grafts used for the treatment of severe alveolar ridge atrophy J. Oral Maxillofac. Surg. 55 1997 1227-1233
    • (1997) J. Oral Maxillofac. Surg. , vol.55 , pp. 1227-1233
    • Schliephake, H.1    Neukam, F.W.2    Wichmann, M.3
  • 36
    • 0033169237 scopus 로고    scopus 로고
    • Long-term results of endosteal implants used for restoration of oral function after oncologic surgery
    • Schliephake H. Neukam R. Schmelzeisen R. Wichmann M. Long-term results of endosteal implants used for restoration of oral function after oncologic surgery Int. J. Oral Maxillofac. Surg. 28 1999 260-265
    • (1999) Int. J. Oral Maxillofac. Surg. , vol.28 , pp. 260-265
    • Schliephake, H.1    Neukam, R.2    Schmelzeisen, R.3    Wichmann, M.4
  • 37
    • 0012377689 scopus 로고    scopus 로고
    • A comparison of implant stability in mandibular and maxillary bone using RFA
    • Meredith N, Sennerby L, eds: Proceedings of European Commission Demonstration Project: Resonance Frequency Analysis Symposium, Gothenburg, Sweden
    • Sennerby L, Friberg B, Lindén B, Jemt T, Meredith N. A comparison of implant stability in mandibular and maxillary bone using RFA. In: Meredith N, Sennerby L, eds: Proceedings of European Commission Demonstration Project: Resonance Frequency Analysis Symposium, Gothenburg, Sweden 2000
    • (2000)
    • Sennerby, L.1    Friberg, B.2    Lindén, B.3    Jemt, T.4    Meredith, N.5
  • 38
    • 0029303073 scopus 로고
    • Reconstructive procedures with endosseous implants in grafted bone: A review of the literature
    • Tolman Dan E. Reconstructive procedures with endosseous implants in grafted bone: A review of the literature Int. J. Oral Maxillofac. Implants 10 1995 275-294
    • (1995) Int. J. Oral Maxillofac. Implants , vol.10 , pp. 275-294
    • Tolman, D.E.1
  • 39
    • 0030184550 scopus 로고    scopus 로고
    • Rehabilitation of the resorbed maxilla and mandible using autogenous bone grafts and osseointegrated implants
    • Williamson R.A. Rehabilitation of the resorbed maxilla and mandible using autogenous bone grafts and osseointegrated implants Int. J. Oral Maxillofac. Implants 11 1996 476-488
    • (1996) Int. J. Oral Maxillofac. Implants , vol.11 , pp. 476-488
    • Williamson, R.A.1
  • 40
    • 0030073280 scopus 로고    scopus 로고
    • Titanium implants and onlay bone graft to the atrophic edentulous maxilla. A 3-year longitudinal study
    • Åstrand P. Nord P.G. Brånemark P.-I. Titanium implants and onlay bone graft to the atrophic edentulous maxilla. A 3-year longitudinal study Int. J. Oral Maxillofac. Surg. 25 1996 25-29
    • (1996) Int. J. Oral Maxillofac. Surg. , vol.25 , pp. 25-29
    • Åstrand, P.1    Nord, P.G.2    Brånemark, P.-I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.