Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: A pilot study

Author keywords

Implant stability; Maxilla; Resonance frequency analysis

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; BONE REGENERATION; DENTAL SURGERY; EDENTULOUSNESS; FEMALE; HUMAN; MALE; MAXILLA; MIDDLE AGED; OSTEOLYSIS; PILOT STUDY; RADIOGRAPHY; SEX DIFFERENCE; STATISTICAL MODEL; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TOOTH RADIOGRAPHY; TRANSDUCER; VIBRATION;

EID: 27544491195     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (93)

References (30)
  • 1
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 2
    • 0029439911 scopus 로고
    • Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants
    • Sunden S, Grondahl K, Grondahl HG. Accuracy and precision in the radiographic diagnosis of clinical instability in Brånemark dental implants. Clin Oral Implants Res 1995;6:220-226.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 220-226
    • Sunden, S.1    Grondahl, K.2    Grondahl, H.G.3
  • 3
    • 0035552535 scopus 로고    scopus 로고
    • Stability of implants and natural teeth as determined by the Periotest over 60 months of function
    • Winkler S, Morris HF, Spray JR. Stability of implants and natural teeth as determined by the Periotest over 60 months of function. J Oral Implantol 2001;27:198-203.
    • (2001) J Oral Implantol , vol.27 , pp. 198-203
    • Winkler, S.1    Morris, H.F.2    Spray, J.R.3
  • 4
    • 0031108095 scopus 로고    scopus 로고
    • The use of the Periotest value as the initial success criteria of an implant: 8-Year report
    • Aparicio C. The use of the Periotest value as the initial success criteria of an implant: 8-year report. Int J Periodontics Restorative Dent 1997;17:150-161.
    • (1997) Int J Periodontics Restorative Dent , vol.17 , pp. 150-161
    • Aparicio, C.1
  • 5
    • 0029314564 scopus 로고
    • Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures
    • Mericske-Stern R, Milani D, Mericske E, Olah A. Periotest measurements and osseointegration of mandibular ITI implants supporting overdentures. Clin Oral Implants Res 1995;6:73-82.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 73-82
    • Mericske-Stern, R.1    Milani, D.2    Mericske, E.3    Olah, A.4
  • 6
    • 0032458301 scopus 로고    scopus 로고
    • A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants
    • Meredith N. A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. Crit Rev Biomed Eng 1998;26:275-291.
    • (1998) Crit Rev Biomed Eng , vol.26 , pp. 275-291
    • Meredith, N.1
  • 7
    • 0032059195 scopus 로고    scopus 로고
    • Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability
    • Meredith N, Friberg B, Sennerby L, Aparicio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodont 1998;11:269-275.
    • (1998) Int J Prosthodont , vol.11 , pp. 269-275
    • Meredith, N.1    Friberg, B.2    Sennerby, L.3    Aparicio, C.4
  • 8
    • 0030224153 scopus 로고    scopus 로고
    • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis
    • Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-267.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 261-267
    • Meredith, N.1    Alleyne, D.2    Cawley, P.3
  • 9
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8:226-233.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 10
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study. Clin Implant Dent Relat Res 2002;4:128-132.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 11
    • 0031644610 scopus 로고    scopus 로고
    • Treatment of the atrophic edentulous maxilla with implant-supported overdentures: A review of the literature
    • Chan MF, Narhi TO, de Baat C, Kalk W. Treatment of the atrophic edentulous maxilla with implant-supported overdentures: A review of the literature. Int J Prosthodont 1998;11:7-15.
    • (1998) Int J Prosthodont , vol.11 , pp. 7-15
    • Chan, M.F.1    Narhi, T.O.2    De Baat, C.3    Kalk, W.4
  • 12
    • 0026167719 scopus 로고
    • Early failures in 4,641 consecutively placed Brånemark dental implants: A study from stage 1 surgery to the connection of completed prostheses
    • Friberg B, Jemt T, Lekholm U. Early failures in 4,641 consecutively placed Brånemark dental implants: A study from stage 1 surgery to the connection of completed prostheses. Int J Oral Maxillofac Implants 1991;6:142-146.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 142-146
    • Friberg, B.1    Jemt, T.2    Lekholm, U.3
  • 13
    • 0036719340 scopus 로고    scopus 로고
    • Clinical outcome of Brånemark System implants of various diameters: A retrospective study
    • Friberg B, Ekestubbe A, Sennerby L. Clinical outcome of Brånemark System implants of various diameters: A retrospective study. Int J Oral Maxillofac Implants 2002;17:671-677.
    • (2002) Int J Oral Maxillofac Implants , vol.17 , pp. 671-677
    • Friberg, B.1    Ekestubbe, A.2    Sennerby, L.3
  • 14
    • 0026246146 scopus 로고
    • The effects of preoperative resorption and jaw anatomy on implant success. A report of 303 cases
    • Bass SL, Triplett RG. The effects of preoperative resorption and jaw anatomy on implant success. A report of 303 cases. Clin Oral Implants Res 1991;2:193-198.
    • (1991) Clin Oral Implants Res , vol.2 , pp. 193-198
    • Bass, S.L.1    Triplett, R.G.2
  • 15
    • 0033172716 scopus 로고    scopus 로고
    • Long-term evaluation of 282 implants in maxillary and mandibular molar positions: A prospective study
    • Becker W, Becker BE, Alsuwyed A, Al-Mubarak S. Long-term evaluation of 282 implants in maxillary and mandibular molar positions: A prospective study. J Periodontol 1999;70:896-901.
    • (1999) J Periodontol , vol.70 , pp. 896-901
    • Becker, W.1    Becker, B.E.2    Alsuwyed, A.3    Al-Mubarak, S.4
  • 16
    • 0026084439 scopus 로고
    • The excessive loss of Brånemark fixtures in type IV bone: A 5-year analysis
    • Jaffin RA, Berman CL. The excessive loss of Brånemark fixtures in type IV bone: A 5-year analysis. J Periodontol 1991;62:2-4.
    • (1991) J Periodontol , vol.62 , pp. 2-4
    • Jaffin, R.A.1    Berman, C.L.2
  • 17
    • 0033197090 scopus 로고    scopus 로고
    • Long-term results after placement of dental implants: Longitudinal study of 1,964 implants over 16 years
    • Noack N, Willer J, Hoffmann J. Long-term results after placement of dental implants: Longitudinal study of 1,964 implants over 16 years. Int J Oral Maxillofac Implants 1999;14:748-755.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 748-755
    • Noack, N.1    Willer, J.2    Hoffmann, J.3
  • 18
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part 1:8-year life table analysis of a prospective multi-center study with 2,359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implants. Part 1:8-year life table analysis of a prospective multi-center study with 2,359 implants. Clin Oral Implants Res 1997:8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 21
    • 0032018553 scopus 로고    scopus 로고
    • A comparison of maxillary and mandibular bone mineral densities
    • Devlin H, Horner K, Ledgeron DJ. A comparison of maxillary and mandibular bone mineral densities. J Prosthet Dent 1998;79:323-327.
    • (1998) J Prosthet Dent , vol.79 , pp. 323-327
    • Devlin, H.1    Horner, K.2    Ledgeron, D.J.3
  • 22
    • 0032153155 scopus 로고    scopus 로고
    • The effects of age, jaw site and bone condition on oral implant outcomes
    • Bryant SR. The effects of age, jaw site and bone condition on oral implant outcomes. Int J Prosthodont 1998;11:470-490.
    • (1998) Int J Prosthodont , vol.11 , pp. 470-490
    • Bryant, S.R.1
  • 23
    • 0036547410 scopus 로고    scopus 로고
    • The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants
    • Cochran DL, Buser D, ten Bruggenkate CM, et al.The use of reduced healing times on ITI implants with a sandblasted and acid-etched (SLA) surface: Early results from clinical trials on ITI SLA implants. Clin Oral Implants Res 2002;13:144-153.
    • (2002) Clin Oral Implants Res , vol.13 , pp. 144-153
    • Cochran, D.L.1    Buser, D.2    Ten Bruggenkate, C.M.3
  • 24
    • 0142088695 scopus 로고    scopus 로고
    • Early loading of nonsubmerged titanium implants with a sandblasted and acid-etched (SLA) surface: 3-Year results of a prospective study in partially edentulous patients
    • Bornstein MM, Lussi A, Schmid B, Belser UC, Buser D. Early loading of nonsubmerged titanium implants with a sandblasted and acid-etched (SLA) surface: 3-year results of a prospective study in partially edentulous patients. Int J Oral Maxillofac Implants 2003;18:659-666.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 659-666
    • Bornstein, M.M.1    Lussi, A.2    Schmid, B.3    Belser, U.C.4    Buser, D.5
  • 25
    • 0042513564 scopus 로고    scopus 로고
    • Immediate occlusal loading of Brânemark TiUnite implants placed predominantly in soft bone: 1-Year results of a prospective clinical study
    • Glauser R, Ruhstaller P, Gottlow J, Sennerby L, Portmann M, Hämmerle CH. Immediate occlusal loading of Brânemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clin Implant Dent Relat Res 2003;5:47-56.
    • (2003) Clin Implant Dent Relat Res , vol.5 , pp. 47-56
    • Glauser, R.1    Ruhstaller, P.2    Gottlow, J.3    Sennerby, L.4    Portmann, M.5    Hämmerle, C.H.6
  • 26
    • 0036987398 scopus 로고    scopus 로고
    • Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study
    • Balleri P, Cozzolino A, Ghelli L, Momicchioli G, Varriale A. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: A pilot study. Clin Implant Dent Relat Res 2002;4:128-132.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 128-132
    • Balleri, P.1    Cozzolino, A.2    Ghelli, L.3    Momicchioli, G.4    Varriale, A.5
  • 27
    • 0041511713 scopus 로고    scopus 로고
    • Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after 1 year of loading, case series
    • Olsson M, Urde G, Andersen JB, Sennerby L. Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after 1 year of loading, case series. Clin Implant Dent Relat Res 2003;5(suppl 1):81-87.
    • (2003) Clin Implant Dent Relat Res , vol.5 , Issue.1 SUPPL. , pp. 81-87
    • Olsson, M.1    Urde, G.2    Andersen, J.B.3    Sennerby, L.4
  • 28
    • 0031152150 scopus 로고    scopus 로고
    • Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla
    • Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8:226-233.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 226-233
    • Meredith, N.1    Book, K.2    Friberg, B.3    Jemt, T.4    Sennerby, L.5
  • 29
    • 0142088696 scopus 로고    scopus 로고
    • Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    • Barewal RM, Oates TW, Meredith N, Cochran DL. Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac Implants 2003;18:641-651.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 641-651
    • Barewal, R.M.1    Oates, T.W.2    Meredith, N.3    Cochran, D.L.4
  • 30
    • 0034157357 scopus 로고    scopus 로고
    • Time dependent failure rate and marginal bone loss of implant supported prostheses: A 15-year follow-up study
    • Snauwaert K, Duyck J, van Steenberghe D, Quirynen M, Naert I. Time dependent failure rate and marginal bone loss of implant supported prostheses: A 15-year follow-up study. Clin Oral Investig 2000;4:13-20.
    • (2000) Clin Oral Investig , vol.4 , pp. 13-20
    • Snauwaert, K.1    Duyck, J.2    Van Steenberghe, D.3    Quirynen, M.4    Naert, I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.